Loading...
HomeMy WebLinkAboutE000 ELECTRICAL COVERSHEETELECTRICAL SYMBOL LIST SYMBOL: TAG: SPEC E TI N: DESCRIPTION: GB GB 260526 GROUND BUS IBT IBT 260526 INTERSYSTEM BONDING TERMINATION E E ECONN 260533 ELECTRICAL CONNECTION J JB 260533 JUNCTION BOX ® FB-1 262726 FLOOR BOX- DUPLEX RECEPTACLE so FB-2 262726 FLOOR BOX- DUAL COMPARTMENT NMI FB-3 262726 FLOOR BOX - MULTISERVICE ®BV FB4 262726 FLOOR -SERVICE FITTING ®RI RI -TECH 260533 TECHNOLOGY ROUGH -IN RI v RI-TECH-W 260533 TECHNOLOGY ROUGH -IN, MOUNTED+54"AFF WM-# 260535 MULTI OUTLET SYSTEM ® WW-# 260535 ELECTRICAL WIREWAY wI DEVICES SHOWN PB PB 260916 MOMENTARY PUSHBUTTON OPERATOR a PANEL'###' 262416 PANELBOARD- RECESS MOUNT 0 PANEL'###' 262416 PANELBOARD- SURFACE MOUNT 01 MX4NMS-#/FCS-# 262419 MANUAL SWITCH/STARTER/COMBINATION STARTER ® TR-# 262200 TRANSFORMER 01 BCS-# 262500 BUSS PLUG- COMBINATION STARTER 0 BP-# 262500 BUSS PLUG -CIRCUIT BREAKER �I BFP-# 262500 BUSS PLUG- FUSIBLE DISCONNECT RECREC=DUP 262726 DUPLEX RECEPTACLE, 125V REC-DUP-GFI 262726 DUPLEX GFI RECEPTACLE, 125V REC-DUP-PED 260533 RECEPTACLE -PEDESTAL STYLE Wag REC-DUP-WP 262726 DUPLEX GFI WEATHERPROOF RECEPTACLE 125V U� REC-USB 262726 DUPLEX RECEPTACLE, USB CHARGING Q RECSIM-52OR 262726 SIMPLEX RECEPTACLE, 12W ♦ RECSIM-53OR 262726 RECEPTACLE, 125V RECSIM-62OR 262726 RECEPTACLE, 6-20R, 25W RECSIM-63OR 262726 RECEPTACLE, 6-30R, 25W im RECSIM-65OR 262726 RECEPTACLE, 6-50R, 25W RECSIM-72OR 262726 RECEPTACLE, 7-20R, 277V RECSIM-73OR 262726 RECEPTACLE, 7-30R, 277V so RECSIM-75OR 262726 RECEPTACLE, 7-50R, 277V REC-SIM-142OR 262726 RECEPTACLE, 14-20R, 1251250V REC-SIM-143OR 262726 RECEPTACLE, 14-30R, 125/25W REC-SIM-145OR 3111, 262726 RECEPTACLE, 14-50R, 125/25W REC-SIM-146OR =40 262726 RECEPTACLE, 14-60R, 125/25W REC-SIM-152OR -18 262726 RECEPTACLE, 15-20R, 2501 3PH REC-SIM-153OR =@ 262726 RECEPTACLE, 15-30R, 2501 3PH REC-SIM-155OR am 262726 RECEPTACLE, 15-50R, 25OV, 3PH REC-SIM-156OR -0I 262726 RECEPTACLE, 15-60R, 25OV, 3PH 61 REC-SIM-L52OR 262726 RECEPTACLE, LOCKING TYPE, LS-20R, 125V _16)I REC-SIM-L53OR 262726 RECEPTACLE, LOCKING TYPE, LS-30R, 125V -Ell REC-SIM-L62OR 262726 RECEPTACLE, LOCKING L6-20R, 250V _ffiI REC-SIM-L63OR 262726 RECEPTACLE, LOCKING L6-30R, 250V -9I REC-SIM-L72OR 262726 RECEPTACLE, LOCKING L7-20R, 277V ♦1 REC-SIM-L73OR 262726 RECEPTACLE, LOCKING L7-30R, 277V 61 RECSI 262726 RECEPTACLE, LOCKING L14-20R, 1251250V REC-SIM-L143OR �I 262726 RECEPTACLE, LOCKING L14-30R, 125/250V RECREC-SI� �I 262726 RECEPTACLE, LOCKING L15-20R, 25OV, 3PH RECREC-SI� 262726 RECEPTACLE, LOCKING L15-30R, 250V, 3PH RECSI 9*I 262726 RECEPTACLE, L16-30R, 48OV, 3PH RECSI -DI 262726 RECEPTACLE, LOCKING L21-20R, 120/208V, 3PH RECSIM-L213OR �I 262726 RECEPTACLE, LOCKING L21-30R, 120/208V, 3PH REC-QUAD 262726 QUAD RECEPTACLE, 12W ap REC-QUAD-GFI 262726 QUAD GFI RECEPTACLE, 125V REC-QUAD-USB 26 27 26 QUAD RECEPTACLE, USB 125V U* WaN REC-0UAD-WP 262726 QUAD GFIWEATHERPROOF RECEPTACLE, 125V REC-PEDQUAD 260533 RECEPTACLE - PEDESTALSTYLE REC-FB-# ® 262726 FLOOR BOX - POKE THRU, 125V # REC-PP# 262723 POWER POLE ELECTRICAL EQUIPMENT TAGS TAG: DESCRIPTION: RELATED SPECIFICATION BCS-# BUS PLUG COMBINATION STARTER 262500 BFP-# BUS PLUG FUSIBLE DISCONNECT 262500 BP-# BUS PLUG CIRCUIT BREAKER 262500 C=# GENERAL PURPOSE CONTACTOR 262821 CB-# CIRCUIT BREAKER, REFER TO DISCONNECT AND STARTER SCHEDULE 261419 CT-# CABLE TRAY 26 05 36 DP-# DISTRIBUTION PANEL 262416 DS-# DISCONNECT SWITCH, REFER TO DISCONNECT AND 262816 STARTER SCHEDULE DTR-# TRANSFORMER- DISTRIBUTION TYPE 261219 261213 261221 F# LUMINAIRE TYPE 265100 FAA-# FIRE ALARM - ANNUNCIATOR 283100 FAP# FIRE ALARM -CONTROL PANEL 283100 FB-# FLOOR BOX 262726 FDS-# FUSIBLE DISCONNECT SWITCH, REFER TO DISCONNECT AND 262816 STARTER SCHEDULE LC# LIGHTING CONTACTOR, REFER TO CONTACTOR SCHEDULE 262831 MS# MANUAL STARTER, REFER TO DISCONNECT AND STARTER SCHEDULE 262419 MX-# MANUAL SWITCH, REFER TO DISCONNECTAND STARTER SCHEDULE 262419 NEP-# FIRE ALARM -EXTENDER PANEL 283100 PP# POWER POLE 262723 R# RELAY 260939 REC-# RECEPTACLE -SPECIAL USE 262726 TC# TIME SWITCH 260933 TRITE! TRANSFORMER - DRYTYPE, REFER TO TRANSFORMER SCHEDULE 262200 UPS-# UNINTERRUPTIBLE POWER SUPPLY 263353 VFD-# VARIABLE FREQUENCY DRIVE- REFER TO VFD SCHEDULE 262923 WW-# WIREWAY 260535 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Carmel ELECTRICAL SYMBOL LIST SYMBOL: TAG: SPEC DESCRIPTION: SECTION: S SW-iP 260933 SWITCH -SINGLE POLE ST SW-IP-ADJ 260933 SWITCH - LOCALTIMER- USERADJUSTABLE SM SW-1P-M 260933 SWITCH- MOMENTARY CONTACT S2 SW-2P 260933 SWITCH - TWO POLE S3 SWSW3W 260933 SWITCH -THREE WAY S4 SW4W 260933 SWITCH - FOUR WAY O SW-D-LED 260933 DIMMER -LED D3 SW-D3-LED 260933 DIMMER - LED -3-WAV DO SWSWOD 260933 DIMMER- WALL DIMMER OCCUPANCY SENSOR LS SW-LS 260933 DAYLIGHT LEVEL SENSOR LS SW-LS-3Z 260933 DAYLIGHT LEVEL SENSOR-3 ZONE 3 LS SW-LS-D 260933 DAYLIGHT LEVEL SENSOR-1 ZONE DIMMING 0 LS SW-LS-D-3Z 260933 DAYLIGHT LEVEL SENSOR-3 ZONE DIMMING 30 QD SW-OC-D 260933 OCCUPANCY SENSOR - DUAL TECHNOLOGY OC SW-OC-D-W 260933 OCCUPANCY SENSOR - DUAL D TECHNOLOGY -WALL MOUNTED SO SW-OC-P-O 260933 SWITCH- OCCUPANCY SENSOR WALL SWITCH S02 SW-OC-P-02 260933 SWITCH- OCCUPANCY SENSOR AND DUAL SWITCH SW SW 260933 WALL CONTROL STATION #B SW-DCS 260933 DIMMER CONTROL STATION LCS SW-LCS 260933 DIMMER CONTROL STATION WITH FADERS O CB-# 262816 CIRCUIT BREAKER - SURFACE MOUNTED II CB-# 262816 CIRCUIT BREAKER - FLUSH MOUNTED DS-# F# 262816 265100 DISCONNECT LINEAR LUMINAIRES 0 F# 265100 TROFFER F# 265100 WALL SCONCE LUMINAIRE O F# 265100 DOWNLIGHTLUMINAIRE <O F# 2651 00 AIMABLE OR WALL WASH LUMINAIRE F# 265100 INDUSTRIAL LUMINAIRE 11 F# 265100 WALL BRACKET LUMINAIRE ® X# 265100 SINGLE FACE EXIT SIGN ® X# 265100 DOUBLE FACE EXIT SIGN ELECTRICAL SYMBOL LIST SYMBOL: TAG: SPEC DESCRIPTION: p FAFA100 283100 FIRE ALARM CONTROL PANEL SD FA120 283100 FIRE ALARM SMOKE DETECTOR - CEILING MOUNTED SD FA122 283100 FIRE ALARM DUCT SMOKE DETECTOR 0 FA l30 2831 00 FIRE ALARM MANUAL PULL STATION OFA140 2831 00 FIRE ALARM HEAT DETECTOR MM FA160 283100 FIRE ALARM ADDRESSABLE MONITOR MODULE AR FA161 283100 FIRE ALARM ADDRESSABLE RELAY Vi V3 VS al FA200 283100 FIRE ALARM VISUAL NOTIFICATION V7 VH DEVICE - WALL MOUNTED V3, WeVi V7 VH FA=201 283100 FIRE ALARM VISUAL NOTIFICATION DEVICE - CEILING MOUNTED AQ FA=210 283100 FIRE ALARM AUDIO NOTIFICATION DEVICE - WALL MOUNTED Al A3 FA211 283100 FIRE ALARM AUDIO/VISUAL NOTIFICATION A7 AH DEVICE - WALL MOUNTED AS AO FA230 283100 FIRE ALARM AUDIO NOTIFICATION DEVICE - CEILING MOUNTED Ai A3 FA231 283100 FIRE ALARM AUDIO/VISUAL NOTIFICATION mAS AT AH DEVICE - CEILING MOUNTED RI FA241 283100 FIRE ALARM REMOTE INDICATOR FS FAFA=260 2831 00 FIRE ALARM FLOW SWITCH TO MONITOR FIRE PROTECTION SYSTEM es FAFA261 283100 FIRE ALARM MONITOR SWITCH TO MONITOR FIRE PROTECTION SYSTEM DH FA270 283100 FIRE ALARM ELECTROMAGNETIC DOOR HOLD DEVICE HD HD ARCH HAND DRYER pp PP ARCH PUSH PAD THESE NOTES APPLY TO ALL ELECTRICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED TO, LIGHTING, POWER, AND SYSTEMS. 1. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD SURVEYS, EXISTING BUILDING DOCUMENTS, AND STAFF. VERIFY EXISTING CONDITIONS AND REPORT ANY CONFLICTS BEFORE PROCEEDING. 2. NOT ALL EXISTING EQUIPMENT LUMINAIRES AND CONDUITARE SHOWN. VERIFY EXISTING CONDITIONS AND REPORT ANY CONFLICTS WITH NEW WORK BEFORE STARTING WORK. 3. FIELD VERIFY THE AVAILABLE CLEARANCES FOR CABLE TRAY, BUSWAYAND CONDUITS BEFORE FABRICATION. RISES AND DROPS MAY BE NECESSARY BECAUSE OF EXISTING FIELD CONDITIONS. 4. EACH CONTRACTOR SHALL FIELD VERIFY ACCESSIBILITY TO THE AREA OF HISHER WORK AND SHALL NOTIFY THE GENERAL CONTRACTOR PRIOR TO BIDDING IF OTHER UTILITIES ARE REQUIRED TO BE REMOVED OR RELOCATED TO ALLOW ACCESS TO HISIHER AREA OF WORK. 5. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CUTTING, REMOVAL AND PATCHING OF ROOFS, WALLS, AND FLOORS ASSOCIATED WITH WORK BY ALL CONTRACTORS. CONTRACTORS SHALL NOTIFY THE GC OF AFFECTED AREAS PRIOR TO BIDDING. 6. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF CEILINGS, CEILING TILES, AND CEILING GRIDS ASSOCIATED WITH AREAS OF WORK BY ALL CONTRACTORS. NOTIFY THE GENERAL CONTRACTOR OF AFFECTED AREAS PRIOR TO BIDDING. 7. WHERE EXISTING ELECTRICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT W ITH NEW EQUIPMENT, PIPING, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTOR SHALL EITHER ARRANGE NEW EQUIPMENT, CONDUIT, OR DUCTWORK IN SUCH A FASHION THAT IT DOES NOT CONFLICT W ITH EXISTING SYSTEMS, OR REWORK EXISTING ELECTRICAL SYSTEMS TO ALLOW FOR INSTALLATION OF NEW EQUIPMENT, PIPING, OR DUCTWORK. ELECTRICAL ABBREVIATION KEY ABBR: DESCRIPTION: AFF ABOVE FINISHED FLOOR C CONDUIT GFI GROUND FAULT INTERRUPTER N.C. NORMALLYCLOSED NIC NOT IN CONTRACT N.O. NORMALLY OPEN SV SOLENOID VALVE TYP TYPICAL UNO UNLESS NOTED OTHERWISE LUMINAIRE SYMBOL KEY SYMBOL: DESCRIPTION: 0 NORMAL BRANCH LUMINAIRE ® ® EMERGENCY LIFE SAFETY BRANCH LUMINAIRE UNSW ITCHED FOR NIGHT LIGHT, UNLESS NOTED'SE' VIEW KEY NAME LEVEL NAME C VINDICATES NOTE USED TO DESCRIBE V 10'-0"HEIGHT ABOVE ADDITIONAL INFORMATION ABOUT PROJECTO'-O" WORK REQUIRED, SPECIFICTOTHE SHEET AND/OR DETAIL INDICATES DIRECTION OF TRUE NORTH PLAN OR DETAIL NUMBER PLAN OR DETAIL NAME " VI W NAME PLAN OR DETAIL SCALE NORS� INDICATES SIMILAR DETAIL SIM REFERENCED IN MULTIPLE LOCATIONS DETAIL REFERRED TO BY SECTION CUT 1 M101 SHEET DETAIL IS LOCATED ON INDICATES SIMILAR DETAIL Sim REFERENCED IN MULTIPLE LOCATIONS DETAIL REFERRED TO BY ELEVATION 4 S Tloi� SHEET DETAIL IS LOCATED ON LINE TYPE KEY: NEW WORK BY THIS CONTRACTOR (DARK SOLID LINE) — — — NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR (DARK LONG DASHED LINE) NEW WORK BY OTHERS AND/OR EXISTING TO REMAIN (LIGHT SOLID LINE) — — — — — — — EXISTING TO BE REMOVED BY THIS CONTRACTOR (DARK SHORT DASHED LINE) ELECTRICAL GENERAL NOTES: 1. ###W# INDICATES ELECTRICAL EQUIPMENT DEFINED IN ELECTRICAL SCHEDULES OR SPECIFICATION. REFER TO DRAWINGS CONTAINING ELECTRICAL SCHEDULES. PERMANENT NAMEPLATE SHALL MATCH FINAL EQUIPMENT NOMENCLATURE, NOT ELECTRICAL EQUIPMENT TAG NAME, REFER TO SPECIFICATIONS. 2. "NL" INDICATES LUMINAIRE IS UNSW ITCHED FOR NIGHT LIGHT. 3. "SE" INDICATES LUMINAIRE IS SWITCHED/CONTROLLED DURING NORMAL OPERATION AND OPERATES FROM EMERGENCY CIRCUIT UPON LOSS OF POWER. 4. SHADED LUMINAIRE OR DEVICE INDICATES LUMINAIRE OR DEVICE IS CONNECTED TO AN EMERGENCY CIRCUIT. LUMINAIRE KEY: F1 = FIXTURE TAG 1 -CIRCUIT NUMBER LUMINAIRE a= SWITCH DESIGNATION NL= SUBSCRIPT (IF APPLICABLE) 'IF LABEL IS ORIENTED HORIZONTALLYA SLASH WILL SEPARATE THIS INFORMATION. EX: F1 111 a I NL DEVICE KEY: DEVICE1r A= MOUNTING (IF APPLICABLE) 1 = CIRCUIT NUMBER 'IF LABEL IS ORIENTED HORIZONTALLYA SLASH WILL SEPARATE THIS INFORMATION. EX: A / 1 ELECTRICAL MOUNTING SUBSCRIPT KEY A MOUNT AT+6" TO CENTERLINE ABOVE COUNTER OR BACKSPLASH C MOUNTATCEILING H MOUNT ORIENTED HORIZONTALLY L MOUNT IN CASEWORK M MOUNT IN MODULAR FURNITURE R MOUNT IN SURFACE RACEWAY 4RXet1014 101il&tf_l4W_AiMilIil101*3 1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDS FOR ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES FOR ALL CONFIGURATION DETAILS ON THIS PAGE FOR ADDITIONAL INFORMATION. 2. CIRCUIT NUMBERS ARE SHOWN FOR CIRCUIT IDENTIFICATION. CIRCUITING SHALL AGREE WITH NUMBERING ON THE PANEL PROVIDED. COMMON NEUTRALS MAY NOT BE USED FOR BRANCH CIRCUITS. BALANCE THE LOAD ON PANELAS EVENLY AS POSSIBLE BETWEEN EACH PHASE. 3. CIRCUITS SERVING EMERGENCYAND EXIT LUMINAIRES WILL BE RUN IN A SEPARATE RACEWAY FROM ALL OTHER CIRCUITS. 4. FLUSH MOUNTALL LIGHTING CONTROL DEVICES AT+46" FROM FLOOR(CENTERLINE DIMENSION), EXCEPT WHERE OTHERWISE NOTED. DEVICES MAY BE SURFACE MOUNTED WHEN CONDUIT IS SPECIFIED EXPOSED. 5. FLUSH MOUNTALL DUPLEX RECEPTACLES AND TECHNOLOGY OUTLETS AT+18" FROM FLOOR(CENTERUNE DIMENSION), EXCEPT WHERE OTHERWISE NOTED. RECEPTACLES AND OUTLETS MAY BE SURFACE MOUNTED WHEN CONDUIT IS SPECIFIED EXPOSED. 6. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS SHALL BE TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF THROUGH -PENETRATION FIRESTOPS. 7. CONNECTION FOR ELECTRIC WATER COOLERS (EWC) SHALL BE A JUNCTION BOX CONCEALED BEHIND WATER COOLERACCESS PLATE OR BE A GFI RECEPTACLE LOCATED DIRECTLY BELOW AND CENTERED ON EWC. CONTRACTOR SHALL VERIFY TYPE OF EWC TO BE INSTALLED. 8. MOUNT ALL FIRE ALARM PULL STATIONS AT+42" FROM FLOOR(CENTERLINE DIMENSION) EXCEPT WHERE OTHERWISE NOTED. 9. INSTALL ALL WALL MOUNTED FIRE ALARM NOTIFICATION DEVICES AT 90" ABOVE FINISHED FLOOR OR 6" BELOW THE CEILING, WHICHEVER IS LOWER, EXCEPT WHERE OTHERWISE NOTED. HEIGHT SHALL BE MEASURED TO THE TOP OF THE DEVICE. 10. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILING MOUNTED DEVICES AND EQUIPMENT W ITH LUMINAIRES, SPRINKLER, AND CEILING DIFFUSERS. CENTER ALL DEVICES IN CEILING TILE PATTERN. SMOKE DETECTORS AND OCCUPANCYNACANCY SENSORS SHALL BE LOCATED NO CLOSER THAN 3 FEET TO AN AIR SUPPLY DIFFUSER OR RETURN GRILLE. 11. CONTRACTOR SHALL VERIFY ALL FURNITURE, MODULAR FURNITURE, AND EQUIPMENT LOCATIONS WITH ARCHITECTURAL PLANS, ELEVATIONS, AND REVIEWED SHOP DRAWINGS. PRIOR TO MAKING THE ACTUAL ELECTRICAL INSTALLATION, THIS CONTRACTOR SHALL ADJUST RECEPTACLES, OUTLETS, OR CONNECTION LOCATIONS TO ACCOMMODATE FURNITURE AND/OR EQUIPMENT. 12. ELECTRICAL AND TECHNOLOGY EQUIPMENT SHALL BE MOUNTED TO AVOID IMPEDANCE OF, OPERATION OF, AND/OR ACCESS TO ELECTRICAL AND MECHANICAL EQUIPMENT. ALL MOUNTING OF ELECTRICAL AND TELECOMMUNICATIONS EQUIPMENT, ON EQUIPMENT SUPPLIED BY ANOTHER CONTRACTOR, SHALL BE APPROVED IN ADVANCE BY THE OTHER CONTRACTOR. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR SEALED INTO OPENINGS. 14. ALL W ELDING SHALL BE ACCORDING TO AMERICAN WELDING SOCIETY STANDARDS. CONTRACTOR SHALL FURNISH TO THE ARCHITECT/ENGINEER CERTIFICATES QUALIFYING EACH WELDER, PRIOR TO START OF WORK. THE ARCHITECT/ENGINEER RESERVES THE RIGHT TO REQUIRE QUALIFYING DEMONSTRATION, AT THE CONTRACTOR'S EXPENSE, OF ANY WELDERS ASSIGNED TO THE JOB. 15. CONTRACTOR SHALL REMOVE AND REINSTALL ALL CEILING TILES AS REQUIRED FOR THE EXECUTION OF ELECTRICAL WORK. CONTRACTOR SHALL REPLACE CEILING TILES WITH IDENTICAL MATERIAL WHERE DAMAGED BY THIS CONTRACTOR. 16. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY AUDIONISUAL, AND OTHER ELECTRICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING MOUNTED DEVICES, OTHER THAN SPRINKLERS. NMEGMEG CORIP RESERVES FROPMEETARY TER DRAWINGAND THE DATA SHMN RE THE EAC-USIVE PROPERT`( OF NEED REPRODUCED MR ANYOTHER PROJECT �=��:� UDING DRAWING ANIALL NOT BE THE EAPRESS �°COMP n OAMERICAN M■ STRUCTUREPOINT INC 7260 smeelane Srman I Imlanapom, Indiana M236 TEL 317.M7.MM I RUX317.343.0270 wxw.WumnspoimspFl *IMEG 8900 KEYSTONE XING PH: 317.848.5045 SUITE 210 FAX 317.844.2201 INDIANAPOLIS, IN www.imegeorp.com 46240 GEICO CORPORATE FIRST FLOOR RENOVATION PHASE 3 101 W. 103RD ST. INDIANAPOLIS, IN 46290 4 No. ° 11400159 STATE OF nnm�ooc(o//o066/ 114/n/ 19 6l Alin 1 ISSUANCE INDEX DATE: 06114119 PROJECT PHASE: CONSTRUCTION DOCUMENTS PHASE 3 REVISION SCHEDULE NO. DESCRIPTION DATE Project Number 18002480.01 ELECTRICAL COVERSHEET DATE: 09/24/19 E000