HomeMy WebLinkAboutE800 DETAILST-0" MAXIMUM FROM BOX TO HANGER (TYPICAL) 9132" DIA. STEEL ROD SUSPENSION FROM BUILDING CONDUIT CLAMP (TYPICAL) STRUCTURE WITHIN OUTLET BOX (T"OF (TYPICAL). 8'-0" MAXIMUM SPACING BETWEEN HANGERS (TYPICAL). STEEL OUTLET BOX, SIZED PER N.E.C. AND SUPPORTED RIGIDLY FROM STRUCTURE (TYPICAL). INSTALL NO CLOSER THAN 1'-0" FROM ANY FIXTURE. CONDUIT (TYPICAL) NOTES: 1. DO NOT SUPPORT CONDUIT OR BOXES FROM CEILING GRID HANGERS. NO SCALE PLASTER RING TO CO WITHIN 1/8"OF FINAL; SEE ARCHITECTURAL PLANS FOR WALL COP NOTES: 1. THE INTENT OF THE DETAIL IS TO ENSURE DEVICE ROUGH -INS ARE ALIGNED, SOLIDLY MOUNTED AND THE SURFACE OF THE TRIM IS EITHER FLUSH WITH THE WALL SURFACE OR WITHIN 1/8" OF THE WALL SURFACE. JUNCTION BOXES LARGER THAN 4" SQUARE SHALL BE MOUNTED IN A MANNER THAT IS SIMILAR TO THE SYSTEM NOTED ABOVE OR ACHIEVES THE SAME RESULTS. 2. PLASTER RINGS DEPTH SHALL BE 1/8" DEEPER THAN THE GYP BOARD APPLIED TO THE WALL. PLASTER RING SHALL BE 314" FOR USE WITH 5/8" GYP BOARD. 3. MOUNTING BRACKET FOR 2 1/2" OR 3 1/2" STUDS SHALL BE CADDY #H23, OR B-LINE 313423. MOUNTING BRACKET FOR FOR 4" OR 6" STUDS SHALL BE CADDY #H46TC OR B-LINE BB4-# . FOR MULTIPLE BOXES BETWEEN STUDS, BRACKET SHALL BE CADDY #RBS16/#RBS24 OR B- LINE BB6# OR BBF# FLOOR MOUNT SUPPORT WITH BBFC. 4. WHERE RECEPTACLE AND TECHNOLOGY DEVICES ARE SHOWN SERVING A COMMON COMPUTER OR EQUIPMENT, OR SHOWN IN SIMILAR LOCATIONS ON THE DRAWINGS THE DEVICES SHALL BE INSTALLED ON OPPOSITE SIDES OF A COMMON STUD OR IN ADJACENT OPENINGS WITH MOUNTING BRACKETS. BACKBOX MOUNTING DETAIL 4 NO SCALE RELEASED FOR CONSTRUCTION 4'-0" MIN., F-0" MAX. LENGTH 318" FLEX CONDUIT WITH 3#18 CONDUCTORS; FACTORY WIRE INTO FIXTURE (TYPICAL). SAFETY CHAIN (OR WIRE) TO STRUCTURE INSTALLED WITH ONE LINK MORE THAN TAUT LENGTH. LUMINAIRE RECESSED (TYPICAL). T-BAR LAY -IN CEILING SUSPENSION SYSTEM (TYPICAL). STEEL OUTLET BOX, SIZE PER N.E.C. AND SUPPORT RIGIDLY FROM STRUCTURE THREADED BALL SWIVEL HANGER STEM, INSTALL FIXTURE WIRING IN STEM (3#18 CONDUCTORS) MOUNTED LUMINAIRE NOTES 1. SELECT STEM LENGTH TO PROVIDE MOUNTING HEIGHT AS REQUIRED ON DRAWINGS. 2. PROVIDE TWO STEMS ON SINGLE LUMINAIRE AND ONE STEM PER LUMINAIRE WHEN JOINED IN CONTINUOUS ROW. 3. LUMINAIRE TO BE MOUNTED LEVEL. PENDANT MOUNTING DETAIL �' NO SCALE ADDITIONAL BOX RATED WALLS: MOLDABLE FIRE STOP PAD, FIVE SIDES OF BOX. 3M TAPE MPPI UL R9700. THREADED ROD SUPPORT PER LUMINAIRE 4" BOX CEILING T'S J FIXTURE � SUPPORT BOX AND CONDUIT FROM STRUCTURE CEILING TIE WIRE FLEX CONDUIT LENGTH: 4'-0" MIN. 6'-0" MAX. ADJUSTABLE SUPPORT BRACKET, 2 PER LUMINAIRE. (ATTACH TO CEILING GRID CHANNELS) LAY -IN CEILING i1 EXIT SIGN MOUNTING DETAIL J NO SCALE 120 VOLT CIRCUIT, SEE PLANS 1/2"CONDUIT TO SECURITY DOOR ACCESS CONTROLLER AND POWER SUPPLY BY MANAGEMENTSYSTEM nnnc el mot lco i;� FIRE ALARM DOOR RELEASE SW CONDUIT 6"x6"x4" JUNCTION BOX WITH LOW VOLTAGE DIVIDER t I' IJI PLASTER RING TO COME IIIq WITHIN I/8"OF FINAL SURFACE. STUD ADDITIONAL BOX SUPPORT F SEE ARCHITECTURAL PLANS FOR WALL CONSTRUCTION. PLAN VIEW NOTES: NOTES: 1. HORIZONTAL CONDUIT CONNECTION BETWEEN BOXES LESS THAN 2'-0" NOT PERMITTED. SEE SPECIFICATIONS AND DRAWING NOTES FOR ADDITIONAL SPACE REQUIREMENTS BETWEEN DEVICES, SIDE BY SIDE DEVICE OPENINGS 1 /2" CONDUIT a DM DOOR MONITOR SENSOR 4"x2 1/2"xi 7/8" DEEP DEVICE BOX IN FRAME. CRi ACCESSIBLE CEILING WHERE APPLICABLE � 314" CONDUIT CARD READER CONTROL STATION. BACK BOX AT+48" A.F.F. 4" x 4" BOX MINIMUM, VERIFY WITH EQUIPMENT SUPPLIER PRIOR TO ROUGH -IN. 1. ALL CONDUIT SHALL BE CONCEALED IN WALLS OR DOOR FRAME, TO ABOVE ACCESSIBLE CEILING. 2. ALL JUNCTION BOXES, CONDUIT AND 120 VOLT CONDUCTORS SHALL BE By CONTRACTOR, UNLESS SHOWN OTHERWISE. 3. ALL CONNECTIONS BY DOOR SUPPLIER CONTRACTOR. 4. VERIFY REQUIREMENTS WITH EQUIPMENT SUPPLIERAND OWNERS REPRESENTATIVE PRIOR TO ROUGH IN. DOOR SECURITY DETAIL 6 NO SCALE +IMEGo��W��o,,o MEG GORP RESERVES FRORRETARY RMMS. INCLUDING COPYRIGHTS. TO THIS n OAMERICAN M■ STRUCTUREPOINT INC 72605MpManE Suman I IMianapolle, Indiana M256 TEL 317.547.5560 1 RUX317.593.0270 wxw.mu ummoim.oan *IMEG 8900 KEYSTONE XING PH: 317.848.5045 SUITE 210 FAX 317.844.2201 INDIANAPOLIS, IN www.imegeorp.com 46240 GEICO CORPORATE FIRST FLOOR RENOVATION PHASE 3 101 W. 103RD ST. INDIANAPOLIS, IN 46290 N0. 11400159 STATE OF t415 V S/jNA �1111E��o(`°+O/n6/ 1L/4/n/ 19 �l :RTIFIED BY ISSUANCE INDEX DATE: 06114119 PROJECT PHASE: CONSTRUCTION DOCUMENTS PHASE 3 REVISION SCHEDULE NO. DESCRIPTION DATE Project Number 18002480.01 DETAILS Subject to compliance with all regulations of State and Local Codes City of Cannel (� AV1:\GL on,V.:T,DA�L DATE: 09/24/19 VPLPHD PARTCPATION OF IMEG CORP. *ARIMES CORP. REFERENCESGIFININCNES n a E800