HomeMy WebLinkAboutG101 FIRST FLOOR LIFE SAFETY PLANC
0
LAN
y
1,524 SF
El M
TRAINING'
(16)
Um
612 SF
(31)
EP
— —
— — — — — — —
— — — — —
— 1
(36)
(36)
(32)
TOR.
81 S
(1) E
TRAINING
TRAINING
TRAINING
720 SF
720 SF
638 SF
in
]
TOR.
TRAINING
TRAINING
] TRAINING
8� S
720 SF
718 SF
635 SIF
\
(36)
(36)
\
(32)
0
(2)
TALENT
MANAGEMENTI
wy
4w
OOR
DROP -IN
Cu
or
EX.
SPRINKLER
1,511 SF
K
K y
758 SF
(16)
w
w
(2)
(3)
_
FACILITIES
FEC
FACILITIES
OFFICE
1,9355E
r
196 SF
EX. LOADING
1,086 SIP
(2)
(4)
0101TRAINING
(19)
STAIR
G101
2,582 SF
BREAKOUT
5515F
1,8895E
why
�Ld(173)
(126)
om
111114n
3a'r(2)
■
_J"71 A
0
]' N
�;N
STOR NE NS EX. MENS
97 SIP 172 SF 229 SF
97 SF %. EL
LQ.
97S
OBBY\ 605ENEW8155E \*OMENS _ EX. WOMENS, EX. EX. MEP . 176 SF[200/240] (1) ms e'.SSF) -FEC- — — — — — -2011 MAX.
(47)
IT TRAINING
935 SF
o ❑
(43)
ITTRAINING
OL
848 SF
GE
O'
IT TRAINING
885 SF
o ❑
(45)
p
k
O
(30)
(36)
(32)
CAFE
722 SF
(49)
TRAINING
TRAINING
TRAINING639S
589 SF
7195E
639 SF\
W
[34014801
S91"I
(1) CORRIDOR
U µ4 SF
VLLU
W
MAIL/STOCK
(3) 823 SF
CORRIDOR
1,586 SF
(38) (38)
FITNESS
1,237 SF
(25)
RECREATION
ROOM
698 SF
(47)
FUTURE
141 SF (2)
FUTURE
54 SF
(2)
U
FUTURE
2,309 SF
(23)
1 0 SF TSO
R (3)
EXIST. MEP
TRAINING CONFERENCE CONFERENCE CONFERENCE
89
TRAINING TRAINING 723 SF
5AI IN 7AI IN 665 SF 647 SF 566 SF 565 SF
9
IP
�9
15 in I
NEW wTL®® HOWER ALCOVE ADA HALL 2 T
(30) 35
71SFS d SF
CORRIDOR L — rc 66 SF S40(Wi9E)R FEC — — — — — — — 2481 MAXOw151 SF�
Ow
l rcN MOTHER zw
FILE (1) LAN OFFICE OFFICE OFFICE I O� LOUNGEKw+ 2
t STORAGE 120 SF 128 SF 128 SF 128 SF (32) (34) U 206 SF
197 SF
(2) (2) (2) (2) I NNS 345 SFS ALCOVE HGWE HALL u`
(1) pyq®® 41SF 62 SF 46 SF 9SF MERCH.
TRAINING TRAINING I JAN. CORRIDOR (1) STOR.
U PRINT 622 SF ® 674 SF 31 SFEl 395 SF 243 SF
INT. 0) INT. 134 SF (2) _, (1) C (2) (2) I WATER
HIRING 83 SF 84SF Ow I (1)209 SF
RECRUITING moo) EXIST. FILE 7 SIF VN OFFICE 11 G
3,458 SF 8INT.4SF 1 z M NS 2)7 SF �m 127 SIF ��t1 I
(3$) INT. ( ) re
Bw All) wincF ® ce'dOr1 /rib (i) (i):- O +`y I EXIS750NF. r EXIST SONF. CONFERENCE CAFE
STORAGE (4)
O MANAGE OFFICE
84SF (1) O� INT. 1) Gw 116 SF 127SF HR I 6315E
INT. U 84SF 1 IS .MEN X. EL EC �"1 _xC (2) (2) RECEPTION (49) (51) (53)
84SF (1) 169 SF a2^ w 589 SF
FFIC
(1) ® OFFICE OFFICE OFFICE (40) I 54 SF
do o WT. INT. EXIST. 120SF 1215F m 128SIF o m I FEC
85 SIF (1) 86 SF BREAKROOM (2) /FEC CORRIDOR
250SF (2) (2) I2,026
LU
INT. INT. INT. r LL (17) HUMAN FEC (1) T 135 R
84SF 85 SF 105 SF ' RESOURCES _ I
11)� _ (1) - (2) �j� 1,972SF (21) o w�, I (1) (2) //
CORRIDOR HR LOBBY (20) (20) why Km
141 SF � 783 SF Jw w ILOBBV FIRE o KITCHEN ��-
TESTING HR we wy I727SF 579SF SERVERV
1 �� 1 (54) 384 SF CONFERENCE) Ke• (49) DINING (3) /+ 2.0705E /
( )INT. ( )INT. 313 SF w I (15)��9 SBY
F i EC (11) /
u 83 SF ed SF 0 O O EX. STAIR 1 I r — DISH ROM ❑
[20012401 820 SF IS(2) COFFEE B /
Ogl
um I
/
SHOP
1 BE
06S
/
/
/
/
IVESTIBULEI — — — — — — — — 205'6- MAX - — — — — — — J
215 SIF I 2
OMEN
SEATING
[690/960] 4,638 Be
(310)
0
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
at State and Local Codes N
City ofCah.nel 1 FIRST FLOOR LIFE SAFETY PLAN
1/16" - l'-0"
CODE LEGEND LIFE SAFETY I BUILDING CODE SUMMARY
------- 2 HR RATED FIRE BARRIERTOREMAN APPLICABLE 2014 Indiana Building Code( IBC)'
BUILDING CODES General Administrdtive Rues, 2nd Edition (GAR)
• 1HR RATED FIRE BARRIER TO REMAIN 2014 Indiana Fire Code
20D9Indiana Electrical Coble
MAX. TRAVEL DISTANCE 2014 Indiana Mechanical Code
2012 Indiana Plumbing Code
(qq) (OCCUPANT LOAD) 2010 Indiana Energy Conservation Code
'Code referenced unless otherwise noted
Id lggl [ACTUAL EGRESS LOAD I ALLOWABLE EGRESS LOAD] SCOPEOF The project involves a partial renovation of the l st floor of an existiig
PROJECT 3-moryoffice Wilding.
EXIT APPUCABIUTY OF Alterations are pemoted to an existing building wtttautrequiring the
CODES TO THE enne existing bulling or partners of the existing building unaffected
PROJECT by he proposed scope of renovation to be brought into compliance
wthcurremccdee [Rule 4, Section 12, GAR]
FUTUREIPAST PHASE OF WORK The requirements in this code summary apply only to new constmctbn.
OCCUPANCY Offices and rooms or spaces used for assembly purposes that are less
CLASSIFICATIONS Nan750 square feet in area or have a calculated occupant load less
FEC
SEMI RECESSED FIRE EXTINGUISHER CABINET WI FIRE Nan 49'
,
EXTINGUISHER. VERIFY LOCATIONS AND Q 1, 303.1.2, exc 1&21
SHAT. QUANTITIES Training and meeting rooms or -B Occupancy (304spaces used for assembly purposN es at
APPLICABLE CODES, OWNER AND FIRE MARSHAL. are 750 square feet a more in area or have a calculated occupant bad
of 50 or mare -less Nan 10%accessory occupancy and less Nan
tabular area of 15,500 square feet for Type IIA Construction
NOTES: -A-3Occupancy [303.4]
FIRE
ONS
A. ONLY. LOCATIONS
OF FIRE EXTINGUISHERS
GUISH WE
AND CABINETS SHATIONS
ONLY COMPLY WITH
Of4SOF. CONTRACTOR TOO VERIFY
QUANTITY AND
CONSTRUCTION Type IlA Cerslmntbn existing
COCATIMS HN AUA . CONTRACTORTOSDICTI NPRI TYAND EXACT TYPE
LOCATIIX4S WITH AUIHgiIIY HATING JURISDICTION PRlgi TO
INSTALLATION. BUILDING Building elements, including strucMal forme, bearing walls, floors,
G WHERE FIRE -RESISTANCE -RATED OR SMOKE -RESISTANCE -RATED WALLS ELEMENTS FIRE and reefs must be a minimum of rancanbustible, 1-hour rated
EXTEND ABOVE A CEILING, SUCH WALLS SHALL BE PERMANENRY AND RESISTIVE construction. [Table6O1l
APPROPRIATELY IDENTIFIED IN ACCORDANCE WITH THE REQUIREMENTS REQUIREMENTS
SET FORTH IN THE BUILDING CODE.
C. VARIANCE IS BEING PURSUED TO ALLOW EGRESS CALCULATION NOT TO OCCUPANCY None required. Occupancy separators not required for accessory uses
BE APPLIED TO TURNSTILES PER IBC SECTION 10083 DUE TO TURNSTILES SEPARATIONS Nat do not occupy more Nan 10% of the building area.
BEING CONNECTED TO ALARM SYSTEM AND FULLY OPENABLE DURING[508.2.1, 5082.41
EMERGENCY.
INCIDENTAL USE None applbableto this project [Table 509]
SEPARATIONS
OCCUPANCYLOAD Business: 100 sq. fi.bcc.
FACTORS Unconcenhated assembly use: 15 sq. 0.locc.
Classrooms: 20 111
Storage Areas: 300 sq. fi.locc. [Table 1004.1.21
CORRIDORS Condors must be a minimumµ inches in dear and urhobstructed
width, a minimum of 36 inches is permitted where serving an
occupant bad less Nan 50 [Table 10182]
Conidomarepermi0edtob mwaledcun mdion. [Table1018.1]
Dead-end corridors must not exceed W feet where serving B
Occupancies and 20 feet where serving A Occupancies.
[1018.4, exc. 2]
DOORS Door width must be a minimum of 32 inches dear and 48 inches
maximum. [1008.1.11
Egress doors must swing in the direction of egress whon serving 50 a
more occupants. Egress doors are required to be side -hinged swtrging
type, except for office and storage area with an occupant Icad of less
than 10. Manually operated horizontal sliding doors pe6nNed here
rooms with an document load that does net exceed l 0 [1008.12]
FUTURE FUTURE FUTURE
146SF 738 SF 140 SF
\ DOOR HARDWARE Panic hardware is required for doors that atch serving A Occupancies
\I where the ronm or area has an occupant bad of 5D or more
\ (2) (2) (2) [1DOB .1.10]
LFREEXIT ACCESS Two exitaccess dons are required Dan rooms a areas wherethe
DOORWAYS occupant bad exceeds 49amaeorwherethecommon pathoftravel
u9
(2) is exceeded. [Table 1RSAI
EXI\ uR (1)
DISTANCE
TRAVEL Common et for trauma must not exceed 75 feet fa t Occupancies
DISTANCE and 1 DO maximtforBOccupanci to [Table 1014.3]
FUTURE The maximum travel and
250distance
for A-3 Occan upancies.
is 300feet for 6
2,602 SF � (2) FUTURE Occupancies and 250 feetfa A-30ccupandes. [Table 1016.21
3,064 SF
(26) FUTURE NUMBER OF EXITS 2 exits required par roar for an occupant bad of 1-500
X.ELE EX. MENS 1 177 SF (31) 3"ts required per floor for an occupant bad of 501-1,000
JHALLW
88SF 168 F I 4 exits required per floor for an occupant bad greaterthan 1,000
[1D21.2]
UTURE IU
l 98 SIF An exit capactyof 0,15inloccupart must be provided fa horizontal
travel such as doers, ramps, etc. and 0.2 inbccupancymusl be
X. JAN. EX. *OMENS UTU prwitletl far stairs. [1005.52]
98 SF 59 SF (1)EMERGENCYAND Exit signs required to indicate the tlieclbn of egress traval fa roans
CORRIDOR EGRESS LIGHTING and areas Nat aware more Nan one exit access. [1011d]
L — +,58111 4 FUTURE Illumination must be provided for required means of egress as wall as
! ( ) FUTURE 384 SF the exit discharge that leads to a public way at all times the building
(3) I W /-�- space served by the means of egress is occupied. [1006,11
FUTURE I LL AUTOMATIC Theisti existing building is spri ddered throughout
294 SIF l SPRINKLERS
T (6) l BRE3" S OM FIRE ALARM Theisti existing building has a fire alarm system
FUTURE l (90) SYSTEM
437 SF
2 Q. 422 SF I m o
O
2 � Ql4O�Q f
G FUTURE c
5375E FUTURE
FUTURE (6) 794 SF N
3,948 SF (8)
(40)
T m FUTURE er
•(L`1L'�I• GFCU
1,070 SF
ILL (11)
FUTURE
2,781 SF
FUTURE (23) l (2) (2) (2)
2" SF FUTUR
(3)
119 SF FUTURE FUTURE
l 133 SF 138 SF
FEC
JAN EX. WOMENS
IE
T.
(1) 7 S PEN LOBBY 7983E 170S IF [690/9601
F ELEV
FFIC G (1) 353 SF ELEV
120SF O X,ELEC EX. MENS
(2) K 88SF ELEV
563E
\ UTURE OPEN O (1) - EX STAIR 4
112 SF OFFICE ww
SF
(2) 1,203 SF wwmo,
(12) K°D VEST.
2 [400/480 ]
(2)
(2)
FUTURE
FUTURE
FUTUR
216 SF
153 SF
148 SF
dI
CIP
OAMERICAN
M■
STRUCTUREPOINT
INC
■
7260 Slua.land Suman I tMfanapolm, Indiana M256
TEL 317.317.MM I FM317.M3D270
www.momrmpoirl
GEICO CORPORATE
FIRST FLOOR
RENOVATION PHASE 3
101 W. 103RD ST.
INDIANAPOLIS, IN 46290
CERTIFIED BY
ISSUANCEINDEX
DATE:
05/31/19
PROJECT PHASE:
CONSTRUCTION DOCUMENTS
PHASE 3
REVISION SCHEDULE
NO. DESCRIPTION DATE
Project Number 2017.01381
FIRST FLOOR LIFE
SAFETY PLAN
DATE: 09/24/19
G 10 1