HomeMy WebLinkAboutM800 DETAILS—CORNER FILLER PIECE OR USE GASKET(TYP.) STRAIGHT TAP CLINCH LOCK BUTT FLANGE FLANGE FOR HT BRANCH WITH BUTT FLANGE FOR BRANCH AND TEE CONNECTIONIN RECTANGULAR DUCTS UNDER 1" PRESSURE CLASS ONLY. 45 DEGREE ENTRY a 45" (L = 4" OR W/4; WHICHEVER IS LARGER) 45 DEGREE ENTRY O 4Y 2 CONICAL FDUCTINER LINED DUCT CONNECTION (NO EXPOSED LINER EDGES) o� D1>D2 45 DEGREE LEAD IN FLANGED DOVETAIL JOINT NOTES: 1. DO NOT USE CONNECTIONS WITH SCOOPS. 2. FIT ALL CONNECTIONS TO AVOID VISIBLE OPENINGS AND SECURE THEM SUITABLY FOR THE PRESSURE CLASS. 3. ADDITIONAL MECHANICAL FASTENERS ARE REQUIRED FOR 4"W.G. AND OVER. 4. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. BRANCH CONNECTIONS NO SCALE y T-BAR CEILING SUPPORTS EGGCRATE RETURN - GRILLE. WW� OVALIROUND RADIUS ELBOW SMOOTH OR 5 GORE (MINIMUM) RAN = 1.5 (MINIMUM) RECTANGULAR MITERED ELBOW TYPE RISE USE ONLY AS PART OF OFFSETS AND TRANSITIONS PER FIGURE 4-7 TYPE 2 OR AS SHOWN ON DRAWINGS. OFFSETS ABOVE 300 SHALL BE TYPE RE1. r r r C Pe7 rc rc tt RECTANGULAR RECTANGULAR RADIUS ELBOW RADIUS ELBOW WITH VANES TYPE RE1 TYPE RE3 FLW = 1.0 (MINIMUM) RAN < 1.0 SHALL BE TYPE REFER TO SMACNA HVAC SYSTEMS DUCT DESIGN MANUAL, RE3 FOURTH EDITION, SECTION 5.14 "SPLITTER VANES" AND SMACNA HVAC DUCT CONSTRUCTION STANDARDS, THIRD EDITION, FIGURES 4-2 AND 4-9 AND CHARTS 4-1 AND 4-1 M. ELBOW SHALL HAVE THREE SPUTTER VANES AND nW = 0.10 (RAN = 0.60) UNLESS NOTED OTHERWISE. WW� RECTANGULAR RECTANGULAR IOVALIROUND MITERED ELBOW MITERED ELBOW WITH VANES WITHOUT VANES TYPE RE2 TYPE RE4 NOT ALLOWED 1161 1. BEAD, CROSSBREAK, AND REINFORCE FLAT SURFACES AS IN STRAIGHT DUCT. 2. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. 3. DEFAULT ELBOW SHALL BE TYPE "REV. 4. ELBOW TYPES SHALL BE INSTALLED AS SHOWN AND NOT BE SUBSTITUTED WITHOUT PERMISSION. EXCEPTION: REi OR RE3 MAY BE SUBSTITUTED FOR RE2. ELBOW CONSTRUCTION 2 NO SCALE g0 RECTANGULAR RADIUS ELBOW WITH SOUARETHROAT NOTALLOWED FLEXIBLE DUCT — MAX. LENGTH 6'-0" :ralNg4aLa71 PROVIDE DURABLE - ELBOW SUPPORT TRIM STRAPS AFTER TIGHTENING STRUCTURE SUSPEND ELBOW WITH TIE DRAW BANDS SNUG, WITHOUT CRUSHING FLEXIBLE DUCT MINIMUM STRAIGHT DUCT NOTES: 1. TO ATTACH FLEX DUCT TO THE HARD DUCT, TAPE THE INNER LINER TO THE HARD DUCT THEN ATTACH WITH TWO NYLON TIE WRAPS; ONE FOR THE INNER LINER AND ONE FOR THE OUTER SHELL. FOLD THE OUTER SHELL INSIDE ITSELF SO IT HAS NEAT EDGES PRIOR TO TIE WRAPPING. 2."SMARTFLOW"ELBOW(WWW.HARTANDCOOLEY.COM), THERMAFLEX"FLEXFLOW" (W W W.THERMAFLEX.NET/FLEXFLOW_ELBOW.PHP7AUD) AND "FLEXRIGHT" (W W W.TITUS-HVAC.COM) ARE ACCEPTABLE PRODUCTS FOR DURABLE ELBOW SUPPORT. DIFFUSER CONNECTION DETAIL NO SCALE / RADIUS FORMING E CUT HELIX AND INNER FABRIC HERE. SECURE WITH NYLON TIE. OVERLAP FLEX DUCT MINIMUM OF 2" ONTO RIGID DUCT. INSULATED INSULATED TRANSITION PROVIDE DUCT SEALER AT CONNECTION FLEX DUCT RECTANGULAR INSULATED DUCT BETWEEN FLEX DUCT AND RIGID DUCT. INSULATED GALVANIZED DUCT Y MAX. FASTEN WITH SELF -TAPPING SHEETMETAL SCREWS (MIN. 4) CUT DUCT OPENING TO MATCH LARGER TAKEOFF DIAMETER o TERMINALAIR BOX AIR FLOW�� PRE -MANUFACTURED CONICAL TAKE -OFF WITH SELF-ADHESIVE NEOPRENE GASKET (EQUAL TO SHEET METAL CONNECTORS CONICAL E-Z TAP) 6"MIN. ¢ az ¢Q¢ ELBOW WITH I"LINER, NO VANES. mp �5wo ATTACH TO NECK OF RETURN I O z O D m I REHEAT COIL (IF SCHEDULED), GRILLE. SEE DRAWINGS FOR SIZE. j o z r INSULATE PER SPECIFICATIONS. SUPPORT DUCTWORK `P m 3 w FROM STRUCTURE ABOVE, NOT FROM CEILING. NYLON TIE WRAP, TWO REQUIRED FOR 11 c Z i EACH END FLEXIBLE DUCT (TOTAL +y < a O ¢ FLOOR ABOVE INSTALL ONEE TIE WRAP TO SECURE THEE - L 24". L INNER LINER AND ONE TO SECURE THE WIDTH OF EQUIPMENT MAINTAIN MINIMUM WORKING 12 x 227 OUTER SHELL. (TYP.) CLEARANCE TO ELECTRICAL 6" OR 30"MIN. (ATONAL EILECTRIC CSAS ODE) REUIRED BV NFPA ]0 CEILING RETURN GRILLE NO SCALE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Cannel DATE: 09/24/19 DUCT LINER (REFER TO LAY -IN CEILING TILE SPECIFICATIONS) NO SCALE X DRAWING FOR SIZE FER DUCT DETAIL (ENDS UP NOTES: 1. THIS DETAIL APPLIES ONLY TO TAPS OFF WRAPPED DUCTS. 2. THIS DETAIL APPLIES TO TERMINAL AIR BOXES WITH ROUND INLETS AND RECTANGULAR OUTLETS. 3. DUCT LEADING TO TAB INLET MUST BE STRAIGHT FOR 1.5 DIAMETER UPSTREAM. 4. MAINTAIN VAPOR BARRIER FROM MAIN TO BRANCH DUCT. TERMINAL AIR BOX DETAIL (WRAPPED MAIN NO SCALE *IMEG oNWeuau,,a MEG GVRP RESERVES RTGPMETARY VKONG PARTCPATI)NI CF IMEG COM' 0ID181MEG1001M REFERENCESCVE IN INCHES GEICO O Eelc6n ®■ STRUCTUREPOINT 7260 SM1adeland Sumon I Indianapolis, Indiana M256 TEL 31].54].5560 I FU31].503.02]0 www.m eturepoim.00m *IMEG 8900 KEYSTONE XING PH: 317.848.5045 SUITE 210 FAX 317.844.2201 INDIANAPOLIS, IN www.imegeorp.com 46240 GEICO CORPORATE FIRST FLOOR RENOVATION PHASE 3 101 W. 103RD ST. INDIANAPOLIS, IN 46290 14:err'r No. hN= PE10505421 STATE C4 _ I rs \ IwNF"/oocco ONAL A puu A noo\0614/19 ��� nnn CERTIFIED BY ISSUANCE INDEX DATE: 06114119 PROJECT PHASE: CONSTRUCTION DOCUMENTS PHASE 3 REVISION SCHEDULE NO. I DESCRIPTION DATE Project Number 18002480.01 DETAILS M800