HomeMy WebLinkAboutP201.A FIRST FLOOR PLUMBING DEMOLITION PLAN -AREA AKEYNOTES: CD
1. 4" VTR TO REMAIN.
2. DISCONNECT AND REMOVE WATER HEATER.
R TO T P 7Fp$ N20V'INATP
ATE CAT T �!
3. EXTERIOR WALL HYDRANT TO REMAIN.
4. PIPING WITHIN KITCHEN, DISHWASHING AND
SERVERY IS SHOWN BASED ON EXTENT OF
INFORMATION AVAILABLE. WHERE EXISTING
FIXTURES ARE REMOVED, REMOVE
ASSOCIATED BRANCH LINES BACK TO MAIN.
eH I
I I
eL I
eN I T
I I I
ITION PLAN -AREA A
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Carmel
DATE: 09/24/19
—
0
DEMOLITION NOTES:
A. ALL EQUIPMENT AND PIPING SHOWN WITH
THIN/LIGHT SOLID LINES IS EXISTING TO
REMAIN.
B. ALL EQUIPMENT AND PIPING SHOWN WITH
THICK/DARK DASHED LINES IS EXISTING TO BE
REMOVED OR RELOCATED.
C. RELEVANT EQUIPMENTAND PIPING SHOWN IS
BASED ON EXISTING DRAWINGS AND FIELD
SURVEY. NOT ALL EXISTING EQUIPMENT AND
PIPING IS SHOWN. CONTRACTOR SHALL FIELD
VERIFY ALL CONDITIONS AFFECTED BY THIS
RENOVATION AND NOTIFY THE ENGINEER IF
CONDITIONS ARE NOT AS INDICATED.
D. OWNER SHALL HAVE FIRST RIGHT OF REFUSAL
UPON REMOVAL OF ALL SALVAGED ITEMS.
OTHERWISE, REMOVE ALL DEMOLISHED ITEMS
FROM THE SITE.
E. REFER TO"NEW WORK" PLANS FOR PIPING
CONTINUATIONS AND/OR REPLACEMENTS.
F. AFTER PIPING REMOVAL, PATCH HOLES
THROUGH WALLS AND FLOORS TO MATCH
SURROUNDING CONDITIONS.
G. REMOVE AND RE -INSTALL EXISTING LAY -IN
CEILING AS REQUIRED TO COMPLETE WORK.
REPLACE DAMAGED CEILING MATERIALS TO
MATCH EXISTING CEILING.
H. REMOVE EXISTING DRYWALL CEILINGS AS
REQUIRED TO COMPLETE WORK. PATCH AND
PAINT CEILINGS TO MATCH EXISTING
CONDITIONS.
I. REMOVE EXISTING DRYWALLMIASONRY WALLS
AS REQUIRED TO COMPLETE WORK. PATCH
AND PAINT WALLS TO MATCH EXISTING
CONDITIONS.
®IMEG ow,�°ACX�T LM94,,D
PIEG CORR RESERVES PROPRIETARY RGH S.INCW OING CWYRIGHTS. TO THIS
DRAWING AND THE DATA SHOWN THEREON. SAID DRAW ING AHMOR DATAARE
THEMMUSNEPRWEH OFMEGC PONDSHNLNOTMUSEDOR
REPRODUCED WRONYOTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVALAND PARTCRATION OF IMEG CORP. OA181MEG COV.
REFEIENCESGAIEININCNg
0
GEICO
so
O AMER ICAN
WE STRUCTUREPOINT
7260 SM1adeland Smon I Indianapolis, Indiana M256
TEL 31].54].5580 1 M)(31].543.02]0
waw.smlaurepwaNcom
*IMEG
8900 KEYSTONE XING PH: 317.848.5045
SUITE 210 FAX 317.844.2201
INDIANAPOLIS, IN www.imegeorp.com
46240
GEICO CORPORATE
FIRST FLOOR
RENOVATION PHASE 3
101 W. 103RD ST.
INDIANAPOLIS, IN 46290
No. ',`u3'=
* t PE10505421\
STATEOF
DIX
�PV n41V
�OjNI1tll pL nouooca 06 14 19
CERTIFIED BY
ISSUANCEINDEX
DATE:
06/14/19
PROJECT PHASE:
CONSTRUCTION DOCUMENTS
PHASE 3
REVISION SCHEDULE
NO. I DESCRIPTION I DATE
Project Number 18002480.01
FIRST FLOOR
PLUMBING
DEMOLITION PLAN -
AREA A
P201.A