HomeMy WebLinkAboutP300.A UNDERFLOOR PLUMBING PLAN -AREA AI
NEWMENS
105A
IX.EL. I
E2
is 11 t° I:
IX. EL. LOBBY
E1 117A _ _ Ow7117 Y _
-fI-' — — — — — — -iP1—
IX. $6iAP1 591�11 00 011 0 0 0 '1 0 40 0 I,Ii
I
-
------------
do do
SECURED LOBBY
-. - - . ..
__..
�
1
10"STD
;... _. .: ................
t
Id
ood
r_,.
_
do
VESTIBULE
V1
do
Prr-::.
I
I
I
I
Y
I
I
I
I
I
YE%4
yJ
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Carried
Floor
102A
WRROOR
C13
do
do
V Healer e
— —
J' .> 4
DISH Dots
IzzA
I
OPEN BEATING
125B
MERCH. STJR.
dim
FCO
4"SAN,J 11M
45AN 8
I: I
CAEBTIRpTE
111A
r....... T ----- ..
b
do
— do
r c -do
'- —
Nv„ 3
2
4
* y
a -
Floor ---
I
u
KEYNOTES:
1. 4" WASTE UP.
2. 4" GSAN UP.
3. 2" WASTE UP.
4. 3" GSAN UP
5. 2" GSAN UP.
6. 2 1/2" VENT UP.
7. REFER TO CIVIL PLANS FOR LOCATION OF GI-1
AND CONNECT.
8. 2" VENT UP.
e0
FUTURE
93
ds
GENERAL NOTES:
A. ALL EQUIPMENT AND PIPING SHOWN WITH THIN/LIGHT SOLID LINES IS EXISTING TO
REMAIN.
B. ALL EQUIPMENT AND PIPING SHOWN WITH THICK/DARK SOLID LINES IS NEW OR
RELOCATED,
C. RELEVANT EQUIPMENT AND PIPING SHOWN IS BASED ON EXISTING DRAWINGS AND
FIELD SURVEY, NOT ALL EXISTING EQUIPMENT AND PIPING IS SHOWN, CONTRACTOR
SHALL FIELD VERIFY ALL CONDITIONS AFFECTED BY THIS RENOVATION AND NOTIFY THE
ENGINEER IF CONDITIONS ARE NOT AS INDICATED.
D. DOMESTIC WATER BRANCH PIPING RUN OUTS TO PLUMBING FIXTURES SHALL BE 3/1
DIAMETER, UNLESS OTHERWISE NOTED.
E. REMOVE AND RE -INSTALL EXISTING LAY -IN CEILING AS REQUIRED TO COMPLETE
WORK. REPLACE DAMAGED CEILING MATERIALS TO MATCH EXISTING CEILING.
F. REMOVE EXISTING DRYWALL CEILINGS AS REQUIRED TO COMPLETE WORK. PATCH
AND PAINT CEILINGS TO MATCH EXISTING CONDITIONS.
G. REMOVE EXISTING DRYWALUMASONRY WALLS AS REQUIRED TO COMPLETE WORK.
PATCH AND PAINT WALLS TO MATCH EXISTING CONDITIONS.
H. THE FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR THE DESIGN,
COORDINATION, AND INSTALLATION OF THE FIRE PROTECTION SYSTEM, INCLUDING
REMOVING AND INSTALLING NEW PIPING AS REQUIRED FOR A COORDINATED
INSTALLATION. THE FIRE PROTECTION SYSTEM IS TO BE DESIGNED AND INSTALLED IN
COMPLIANCE WITH NFPA AND ALL OTHER STATE AND LOCAL CODES.
OFFICE
— } — — �u...1 — —
x i..
IX. ELEGI
4 or 3
—a - - — — — — — — —I .... -.I :_
1 3• I111 �LL LE-_1 lo-or
i F;
- _$Ink- - e3
-- OPEN EFATNG
— U
j� T — — ® _ _ _ — — T
—t�..44
kk
'
. C.....�oodood-d Y_N_.1
�1osT� 'I
or
— — — — — — — — — I— — — r —
N
I
-' — -
- — — — — — — — — — — — — — ------ _
!lo : vcrtd I I I I I I
1
1..............................r: :3APT
I'd do d
1
- Itii::G: T.L::L;ai ;ai
/Irk UNDERFLOOR PLUMBING PLAN -AREA A
'IT
\�
ADB1
And KEYSTONE XING, SUITE 210
MEG CORP RESERVES PROPRIETARY RISKS. INCLUDING COPYRIGHTS. TOTHIS
n RAW INGANO THE DATA SHOWN THEREGN. SAIDORAW ING SIMMONS MTAARE
THE IXCLUSNE PROPERTY OF MEG Codad SHAPE NOT BE USEDOR
REPRODUCED FOR ANYOTHER PROJECT WITHOUT THE EMPRESS WRITTEN
APPR'VALANDPARTCRATION OF IMEG CORP. CASIMES CORP.
REE9lENCESGIE IN INCHES
co
OAMERICAN
M■
STRUCTUREPOINT
INC
7260 SMpnlana Suman I IIMMnapMh, Indiana M256
TEL 317.M7.R60 I f+1I317.393.0270
www.Mrepmrepp flaxam
*IMEG
8900 KEYSTONE XING PH: 317.848.5045
SUITE 210 FAX 317.844.2201
INDIANAPOLIS, IN www.imegcorp.com
46240
GEICO CORPORATE
FIRST FLOOR
RENOVATION PHASE 3
101 W. 103RD ST.
INDIANAPOLIS, IN 46290
dod No.
PE10505421
";nrbo"YHlL n0000•` 06/14/19
OCERTIFIED BY
ISSUANCEINDEX
DATE:
06/14/19
PROJECT PHASE:
CONSTRUCTION DOCUMENTS
PHASE 3
REVISION SCHEDULE
NO.
DESCRIPTION
DATE
1
ADDENDUM 1
07-12-2019
2
PR-1
09-06-2019
Project Number 18002480.01
UNDERFLOOR
PLUMBING PLAN -
AREA A
DATE: 09/24/19
P300.A