Loading...
HomeMy WebLinkAboutP800 DETAILSVACUUM BREAKER �W/ANGLE FLANGES `MIXING FAUCET \ WITH INTEGRAL CHECK VALVES Fes, SUPPLY STOP VALVE ' FLOW CONTROL VALVE ',SOLENOID VALVE 1/2' cW 3+4" CW BODY WATER INLET @ SINK APPLICATIONS SAN �1/2"HIM IMe! : 1. ' DENOTES COMPONENT FURNISHED BY OTHERS AND INSTALLED BY P.C. 2. INSTALL VACUUM BREAKER ON STAINLESS STEEL COUNTERTOP BACKSPLASH IF AVAILABLE OR ON WALL MINIMUM 12" ABOVE FLOOD RIM OF SINK. 3. ALL EXPOSED PIPING TO BE CHROME PLATED. NO SCALE RELEASED FOR CONSTRUCTION Subject to compliance with all regulatims of State and meal Codes City of Carmel DATE: 09/24/19 � UNION PRESSURE GAUGE UTILITY BOX UB-_ - WITH SHUT OFF AND WHA WATER FILTER WF- INDIRECT WASTE TO DRAIN, SIZE PER ICE MACHINE MANUFACTURER'S INSTRUCTION ICE MACHINE BY OTHERS n FS' 2°SAN ICE MACHINE DETAIL 4 NO SCALE il� 140°F BALANCING VALVE IF REQUIRED BY MIXING VALVE MANUFACTURER'S PIPING METHOD. FAUCETS BY OTHERS [BY — P.C.] THREE COMPARTMENT SINK BY OTHERS [BY P.C.] LEVER HANDLE DRAINS AND INDIRECT PIPING BY P.C. 2" AIR GAP EQUAL TO TWICE THE INDIRECT DRAIN PIPE DIAMETER FLOOR SINK WITH DOME STRAINER AND HALF GRATE OR AS INDICATED ON PLUMBING MATERIAL LIST NO SCALE 2"GV 4"GSAN ti CIRCULATING j ������ PUMP CP -'. t 140°F HWC��� ��� ������///���---���a�� I (T: is 115°F HWC� CIRCULATING PUMP CP' U VACUUM RELIEF VALVE. � WATTS N36 OR SIZE AND ROUTE BYPASS EQUIVALENT i PER MIXING VALVE MANUFACTURER'S REQUIRED PIPING METHOD. EXTEND MEMBRANE UP QT SODA LINES BY OTHERS. SIDES OF CHASE AND SEAL. EXPANSION TANK ET' - _ 115°F HW FIRE SEAL AND WATERPROOF z SEAL ALL OPENINGS. 3/4' TEST VALVE FINISHED FLOOR WH ' SET AT 140°F VACUUM BREAKER. WATERPROOF WATTS MODEL BA OR EQUAL MEMBRANE WITH HOSE THREAD AND CAP. CONCRETE SLAB FLOOR THERMOMETER IN WELL (0-200° F) EXTRA LONG SWEEP ELBOW MIXING VALVE MV-' LOCATE BELOW TOP PVC CHASE, ALL OF WATER HEATER PROVIDE HEAT JOINTS SEALED SEE AS TRAP WITH DEPTH AS REQUIRED BY DRAWING FOR SIZE. MIXING VALVE MANUFACTURER. VERIFY EXACT PIPING AND BALANCING REQUIREMENTS WITH MANUFACTURER. moo NErsroNExNG,smTE z+a � I M ap, EG v1R�C45 m mai SCAIF SODA LINE CHASE DETAIL 8 NO SCAIF MEG CORP RESERVES PROPRIETARY RIGHTS. INCLUDING COPYRIGHTS. TO THIS DRAWING AND THE DATA SHOWN THEREON. SLID DRAWING PNDIOR DATA ME THE FALL IVE PRWERHY GF MEG OCRPPND III NOT BE USED OR REPRODUCED FOR MY 01 PROTECT WITHOUT THE EX FFESS WRITTEN FPPROVFLFND PA0.71CPATICN OF II CORP. 0201811HEG COY. REFERENCE Scale IN INI a GEICO •. o ERICAN ®■ STRUCTUREPOINT 7260 SM1adeland 5m+ion I Intianapolis, Indiana M256 TEL 31].54].5560 I FU31].543.02]0 www.anumumpnim.00m 8900 KEYSTONE XING PH: 317.848.5045 SUITE 210 FAX 317.844.2201 INDIANAPOLIS, IN www.imegeorp.com 46240 GEICO CORPORATE FIRST FLOOR RENOVATION PHASE 3 101 W. 103RD ST. INDIANAPOLIS, IN 46290 No. V PE10505421 "Op�1�YAll n000m. 06/14/19 CERTIFIED BY ISSUANCE INDEX DATE: 06/14/19 PROJECT PHASE: CONSTRUCTION DOCUMENTS PHASE 3 REVISION SCHEDULE INO.1 DESCRIPTION I DATE Project Number 18002480.01 DETAILS ':11