HomeMy WebLinkAboutP900 SCHEDULESGEICO PLUMBING FIXTURE SCHEDULE TAG NAME DESCRIPTION MANF. B MODEL CP-1 CIRCULATING PUMP - LEAD FREE BRONZE PUMP - B&G(PL SERIES), TACO(00 SERIES), CONSTRUCTION, PERMANENTLY LUBRICATED SEALED GRUNDFOS(UP SERIES) BEARINGS, MECHANICAL SEAL, OIL LUBRICATED, OPEN DRIP -PROOF NON OVERLOADING MOTOR WITH THERMAL AQUASTAT- HONEYWELL, WHITE-RODGERS, JOHNSON OVERLOAD PROTECTION, FLANGED CONNECTIONS, CONTROLS, SAME AS PUMP MANUFACTURER RATED FOR 125 PSIG AT 225°F, UL LISTED. 5 GPM@ 10 FEET OF HEAD. MOTOR SHALL BE 1/12 HP OPERATING AT 2650 RPM. AQUASTAT - LINE VOLTAGE, ADJUSTABLE SETTING OF 90-18WF WITH STRAP -ON REMOTE SENSOR BULB, UL LISTED. PROVIDE WITH TRANSFORMER IF REQUIRED. INSTALL PER MANUFACTURERS INSTRUCTIONS. ELECTRICAL REQUIREMENTS -120V-1 PHASE (HARD -WIRE) CP-2 CIRCULATING PUMP - LEAD FREE BRONZE PUMP - S&G(PL SERIES), TACO(00 SERIES), CONSTRUCTION, PERMANENTLY LUBRICATED SEALED GRUNDFOS(UP SERIES) BEARINGS, MECHANICAL SEAL, OIL LUBRICATED, OPEN DRIP -PROOF NON OVERLOADING MOTOR WITH THERMAL AQUASTAT- HONEYWELL, WHITE-RODGERS, JOHNSON OVERLOAD PROTECTION, FLANGED CONNECTIONS, CONTROLS, SAME AS PUMP MANUFACTURER RATED FOR 125 PSIG AT 225-F, UL LISTED. 5 GPM@ 10 FEET OF HEAD. MOTOR SHALL BE 1/12 HP OPERATING AT 2650 RPM. AQUASTAT - LINE VOLTAGE, ADJUSTABLE SETTING OF 90-180-F WITH STRAP -ON REMOTE SENSOR BULB, UL LISTED. PROVIDE WITH TRANSFORMER IF REQUIRED. INSTALL PER MANUFACTURERS INSTRUCTIONS. ELECTRICAL REQUIREMENTS -120V-1 PHASE (HARD -WIRE) ET-1 EXPANSION TANK -WELDED BLACK STEEL AMTROL(THERM-X-TROL), B&G(PT), ELBI LOT), CONSTRUCTION, GUARANTEED AIRTIGHT AND FLEXTRON(FLEXTROL), TACO (PAX SERIES), WATTS LEAKPROOF, STAINLESS STEEL SYSTEM CONNECTION, (DETA), WESSELS (TX) HEAVY DUTY BUTYL DIAPHRAGM AND RIGID POLYPROPYLENE LINER MECHANICALLY BONDED TO TANK TO PROVIDE A 100% NON -CORROSIVE WATER RESERVOIR, DIAPHRAGM AND LINER SHALL BE APPROVED FOR USE IN POTABLE WATER SYSTEMS, ALL WETTED COMPONENTS OF FDA APPROVED MATERIALS. PROVIDE STANDARD SCHRADER AIR VALVE FOR FIELD CHARGING. TANK SHALL COMPLY WITH FEDERAL ACT S.3874. MIN IMUM TANK VOLUME TO BE 2 GALLONS MINIMUM ACCEPTING VOLUME TO BE 0.9 GALLONS TANK SHALL HAVE A WORKING TEMPERATURE OF 2006F AND A WORKING PRESSURE OF 125 PSIG. FACTORY PRE -CHARGED FOR SHIPPING. FIELD CHARGE TANK TO 55 PSIG. FCO-1 FLOOR CLEANOUT-ADJUSTABLE, CAST IRON HOUSING, ZURN (Z1400), JOSAM (55000), MIFAB (C1100), SMITH ANCHOR FLANGE, TAPERED THREAD PLUG, SECURED (4000). WADE (6000), WATTS (CO-200) NICKEL BRONZE TOP. TOP STYLE SHALL MATCH FLOOR FINISH AS FOLLOWS: UNFINISHED FLOOR - ROUND SOLID SCORIATED TOP TILE OR TERRAZZO - ROUND RECESSED TOP CARPET- ROUND TOP WITH CARPET MARKER. FD-1 FLOOR DRAIN - CAST IRON BODY, NICKEL BRONZE FLOOR DRAIN -ZURN (Z415), SMITH (2005), WADE ADJUSTABLE TOP, 6" ROUND, 4" BOTTOM OUTLET, It 100), JOSAM (30000), WATTS (FD-100), MIFAB (F1100), FLASHING COLLAR, DEEP SEAL TRAP. SUN (FD1000) TRAP SEAL-W, PLASTIC HOUSING WITH FLEXIBLE TRAP SEAL - SURE SEAL (SS), PROVENT (TRAP GUARD), DIAPHRAGM, SEALING GASKETS, RECLUSES AND SEALS SMITH (QUAD CLOSE), LIQUID BREAKER (GREEN WHEN DISCHARGE IS COMPLETED, ASSE 1072. DRAIN) FS-1 FLOOR SINK -CAST IRON BODY, NICKEL BRONZE RIM AND ZURN (Z1901), SMITH (3151), WADE (9140), JOSAM GRATE, 12" SQUARE, 4" BOTTOM OUTLET, 6" DEEP (49340A), WATTS (FS-740), SIOUX CHIEF (861-2xXFNWC), RECEPTOR WITH STAINLESS STEEL MESH SEDIMENT SUN (FS2000) BUCKET, ACID RESISTANT COATED INTERIOR, SEEPAGE FLANGE WITH CLAMP, DEEP SEAL TRAP. CIA GREASE INTERCEPTOR- UNDERGROUND INSTALLATION, SCHIER(GREAT BASIN GB-250), MIFAB POLYETHYLENE, HDPE, OR FIBERGLASS REINFORCED (XL-MI-G-PL-1150), ZURN GREEN TURTLE(PROCEPTOR POLYESTER CONSTRUCTION, REMOVABLE OR GMC300-PDI) CLEANABLE INTAKE AND DISCHARGE BAFFLES, INTERNAL FLOW CONTROL FITTING IF NECESSARY FOR OPERATION, GASKETED H-20 RATED COVER, PDI G101 COMPLIANT, PDI APPROVED AND LISTED FOR USE, 30 YEAR WARRANTY. PROVIDE RISERS FOR EXTENDING COVER TO GRADE. PROVIDE TWO-WAY CLEANOUTS UPSTREAM AND DOWNSTREAM OF GREASE INTERCEPTOR. PROVIDE TANK HOLD DOWN SYSTEM AS REQUIRED BY MANUFACTURER FOR THE SOIL TYPE AND WATER TABLE. BASIS OF DESIGN SCH IER UNIT DOES NOT REQUIRE TANK OR FLOW CONTROL VENT PIPING. OTHER GREASE INTERCEPTOR MANUFACUTURES MAY REQUIRE TAN KANC FLOW CONTROL FITTING VENT SYSTEMS. THESE ADDITIONAL SYSTEMS SHALL BE INSTALLED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE PROJECT IF THESE ALTERNATIVE PRODUCTS ARE SUBMITTED AND INSTALLED. 100 GPM FLOW, 1,076 LB. GREASE CAPACITY, 275 GALLONS HOLDING CAPACITY, 4" PIPE IN LET AND OUTLET. MB-1 MOP BASIN -PROVIDED BY OTHER AS PART OF KITCHEN MOP BASIN -FIAT (TSB), ACORN(TSH), CREATIVE EQUIPMENT PACKAGE. INDUSTRIES (MC), WILLIAMS (SB) TRIM- EXPOSED TWO HANDLE MIXING FAUCET, BRASS TRIM- DELTA(28C2383), AMERICAN STANDARD CONSTRUCTION, CHROME -PLATED FINISH, SINGLE WING (8344.012), CHICAGO FAUCETS (897CP), MOEN (8124), HANDLES, 114 TURN CERAMIC DISC CARTRIDGE, 3/4" HOSE SPEAKMAN (SC-5812), SYMMONS (S-2490), ZURN THREAD SPOUT WITH ABBE 1053 RATED INTEGRAL (Z8411.1141L) VACUUM BREAKER, WALL BRACE, PAIL HOOK, CHECK STOPS OR INLINE CHECK VALVES TO PREVENT THERMAL VACUUM BREAKER -WATTS (SA), OR APPROVED EQUAL CROSSOVER. FAUCET SHALL COMPLY WITH FEDERAL ACT S.3874. ACCESSORIES - MOP HANGER, HOSE AND HOSE BRACKET, DEEP SEAL TRAP MV-1 MIXING VALVE -HI/LO MASTER THERMOSTATIC MIXING LEONARD (TM-LF SERIES), ACORN CONTROLS (SFMV VALVE ARRANGEMENT FOR TEMPERED WATER CONTROL, SERIES), APOLLO (34HL), BRADLEY (HL SERIES), ALL BRONZEMRASS CONSTRUCTION, ROUGH BRASS LAWLER(800 SERIES), POWERS(LFSH14301LFMM430 FINISH, UNION INLETS WITH STRAINERS, COMBINATION SERIES), SYMMONS (TEMPCONTROL SERIES 7) CHECK STOPS OR SEPARATE SUPPLY CHECK VALVES AN SHUT OFF VALVES, DIAL THERMOMETER ON OUTLET AND INLETS. RATED FOR 10 GPM OUTPUT MAXIMUM AT 20 PSI DIFFERENTIAL AND 5 GPM OUTPUT MINIMUM BASED UPON CONTINUOUS RECIRCULATION. UNIT TO MIX 140 DEGREE F HOT WATER SUPPLY AND 40 DEGREE F COLD WATER SUPPLY FOR 120 DEGREE F OUTLET. PROVIDE FIELD ADJUSTMENT BY FACTORY AUTHORIZED REPRESENTATIVE. UNIT SHALL SHALL BE ABBE 1017 ISTE DAPP ED. MBL ALLC LVW 387 RO-1 REVERSE OSMOSIS SYSTEM -MINERAL REDUCTION FOR EVERPUREMRS-600HE-II FOOD SERVICE APPLICATIONS. 600 GPD PRODUCTION RATE. 120 V. BLADDER TANK- HIGH DENSITY POLYETHYLENE( HDPE) ROMATE 80 INN ER LINER, FIBERGLASS -WOUND AND EPDXY RESIN -SCALED OUTER SHELL, 86.7 GALLON CAPACITY. FILTER HOUSING- POLYPROPYLENE HOUSING WITH PENTAIRE PENTEK 158008 REINFORCED POLYPROPYLENE CAP. 10" LONG SLIME LINE CONFIGURATION. CIRCULATION PUMP - 10 GPM AT 25 FEET OF HEAD. MOTOR SHALL BE 3/4 HP. ELECTRICAL REQUIREMENTS 120 V 1 PHASE. RELEASED FOR CONSTRUCTION Subject to compliance with all milulatims of State and Local Codes City of Cannot PLUMBING FIXTURE SCHEDULE TAG NAME DESCRIPTION MANF. & MODEL SK-1 SINK- PROVIDED BY OTHER AS PART OF KITCHEN INSULATION KIT- MCGUIRE(PROWRAP), JUST(J-ADA), EQUIPMENT PACKAGE. PLUMBEREX (PRO -EXTREME), TRUEBRO (LAV-GUARD2) SINK TRIM - PROVIDED BY OTHER AS PART OF KITCHEN EQUIPMENT PACKAGE. ACCESSORIES -1-1/2" 17 GAUGE CHROME -PLATED BRASS TAILPIECE AND P-TRAP, QUARTER -TURN BALL VALVE TYPE 3/8" CHROME -PLATED BRASS ANGLE SUPPLIES WITH LOOSE KEY STOPS, CHROME -PLATED SOFT COPPER SUPPLY LINES. INSULATION KIT - PRE -MANUFACTURED FOR P-TRAP, STOP VALVES, AND SUPPLY LINES. SK-2 SINK- PROVIDED BY OTHER AS PART OF KITCHEN INSULATION KIT- MCGUIRE(PROWRAP), JUST(J-ADA), EQUIPMENT PACKAGE. PLUMBEREX (PRO -EXTREME), TRUEBRO (LAV-GUARD2) SINK TRIM - PROVIDED BY OTHER AS PART OF KITCHEN EQUIPMENT PACKAGE. ACCESSORIES -1-1/2" 17 GAUGE CHROME -PLATED BRASS TAILPIECE AND P-TRAP, QUARTER -TURN BALL VALVE TYPE 3/8" CHROME -PLATED BRASS ANGLE SUPPLIES WITH LOOSE KEY STOPS, CHROME -PLATED SOFT COPPER SUPPLY LINES. INSULATION KIT - PRE -MANUFACTURED FOR P-TRAP, STOP VALVES, AND SUPPLY LINES. TD-1 TRENCH DRAIN- PROVIDED BY OTHER AS PART OF KITCHEN EQUIPMENT PACKAGE. UB-1 UTILITY BOX -GALVANIZED STEEL ENCLOSURE, ANGLE GUY GRAY (BIM875AB), OATEY (39140) VALVE WITH 11W COMPRESSION OUTLET, INTREGAL WATER HAMMER ARRESTOR. UB-2 UTILITY BOX (NATURAL GAS)- WHITE POWDER COATED TRACPIPE(FGP-WBTM-750) STEEL CONSTRUCTION, 5"W BY5"H BY 3-1/8"D BOX DIMENSIONS, 3/4" PIPE SIZE, BRASS ANGLE SHUT OFF VALVE LOW LEAD 1/4 TURN SHUT OFF VALVE WITH INTEGRAL WATER HAMMER ARRESTOR, 6 FOOT STAINLESS STEEL FLEXIBLE HOSE FOR CONNECTION TO EQUIPMENT. WHA WATER HEATER- OWNER FURNISHED, CONTRACTOR A.O. SMITH(DRE-120) INSTALLED. ELECTRIC, VERTICAL, METAL CABINET, BAKED ENAMEL FINISH, GLASS -LINED ASME STAMPED WELDED STEEL TANK, 150 PSI WORKING PRESSURE, FIBERGLASS OR FOAM INSULATION, BRASS WATER CONNECTIONS AND DRAIN VALVE, ASME APPROVED T&P RELIEF VALVE, MAGNESIUM ANODE ROD, INDIVIDUAL FLANGE -MOUNTED IMMERSION HEATING ELEMENTS SHEATHED WITH CORROSION -RESISTANT METAL ALLOY, EXTERNALLY ADJUSTABLE AUTOMATIC IMMERSION WATER THERMOSTAT, MANUAL RESET HIGH TEMPERATURE CUTOFF SWITCH, ENCLOSED CONTROLS, VENTILATED CONTROL CABINET, PILOT LIGHTS INDICATING MAIN POWER AND HEATING STEPS, CONTROL CIRCUIT TOGGLE SWITCH, SEQUENCING STEP CONTROLLER, CONTROL TRANSFORMER, POWER CIRCUIT FUSES, MAGNETIC CONTACTORS, CERAMIC TERMINAL BLOCK, FACTORY ASSEMBLED AND WIRED, 3-YEAR WARRANTY, UL LISTED, NEC COMPLIANT ELECTRICAL COMPONENTS, COMPLIANT TO NAECA, ASHRAE 90.1 AND ASHRAE 90A. 119 GALLON CAPACITY, 18 KW ELEMENT(S), 148 GPH RECOVERY RATE AT 50-F TEMPERATURE RISE. HEATING ELEMENTS RATED FOR LESS THAN 75 WATTS PER SQUARE INCH. ELECTRICAL REQUIREMENTS -480 VJ PHASE HEATING CIRCUIT, 120V CONTROL CIRCUIT. ®IMEG o� O �ewau,,a ■■ QAPAMCAN ®■ STRUCTUREPOINT 7260 SM1adeland Somon I Indianapolis, Indiana M256 TEL 317.M7.55M I FAx31].503.02]0 www.aminurepoim.00m *IMEG 8900 KEYSTONE XING PH: 317.848.5045 SUITE 210 FAX 317.844.2201 INDIANAPOLIS, IN www.imegeorp.com 46240 GEICO CORPORATE FIRST FLOOR RENOVATION PHASE 3 101 W. 103RD ST. INDIANAPOLIS, IN 46290 No. "`,`* * / PE105050 ' \ STATEOF�; ND I.A ... CERTIFIED BY ISSUANCEINDEX DATE: 06/14/19 PROJECT PHASE: CONSTRUCTION DOCUMENTS PHASE 3 REVISION SCHEDULE NO. I DESCRIPTION I DATE Project Number 18002480.01 SCHEDULES DATE: 09/24/19 MEG GVRP RESERVES FROPRAII VPLPNG PARTLPATICN OF II LONP. 0A1811AEGCGRP. REFERENCESGVE IN INI a 1 P900