HomeMy WebLinkAboutP900 SCHEDULESGEICO
PLUMBING FIXTURE SCHEDULE
TAG NAME
DESCRIPTION
MANF. B MODEL
CP-1
CIRCULATING PUMP - LEAD FREE BRONZE
PUMP - B&G(PL SERIES), TACO(00 SERIES),
CONSTRUCTION, PERMANENTLY LUBRICATED SEALED
GRUNDFOS(UP SERIES)
BEARINGS, MECHANICAL SEAL, OIL LUBRICATED, OPEN
DRIP -PROOF NON OVERLOADING MOTOR WITH THERMAL
AQUASTAT- HONEYWELL, WHITE-RODGERS, JOHNSON
OVERLOAD PROTECTION, FLANGED CONNECTIONS,
CONTROLS, SAME AS PUMP MANUFACTURER
RATED FOR 125 PSIG AT 225°F, UL LISTED.
5 GPM@ 10 FEET OF HEAD. MOTOR SHALL BE 1/12 HP
OPERATING AT 2650 RPM.
AQUASTAT - LINE VOLTAGE, ADJUSTABLE SETTING OF
90-18WF WITH STRAP -ON REMOTE SENSOR BULB, UL
LISTED. PROVIDE WITH TRANSFORMER IF REQUIRED.
INSTALL PER MANUFACTURERS INSTRUCTIONS.
ELECTRICAL REQUIREMENTS -120V-1 PHASE
(HARD -WIRE)
CP-2
CIRCULATING PUMP - LEAD FREE BRONZE
PUMP - S&G(PL SERIES), TACO(00 SERIES),
CONSTRUCTION, PERMANENTLY LUBRICATED SEALED
GRUNDFOS(UP SERIES)
BEARINGS, MECHANICAL SEAL, OIL LUBRICATED, OPEN
DRIP -PROOF NON OVERLOADING MOTOR WITH THERMAL
AQUASTAT- HONEYWELL, WHITE-RODGERS, JOHNSON
OVERLOAD PROTECTION, FLANGED CONNECTIONS,
CONTROLS, SAME AS PUMP MANUFACTURER
RATED FOR 125 PSIG AT 225-F, UL LISTED.
5 GPM@ 10 FEET OF HEAD. MOTOR SHALL BE 1/12 HP
OPERATING AT 2650 RPM.
AQUASTAT - LINE VOLTAGE, ADJUSTABLE SETTING OF
90-180-F WITH STRAP -ON REMOTE SENSOR BULB, UL
LISTED. PROVIDE WITH TRANSFORMER IF REQUIRED.
INSTALL PER MANUFACTURERS INSTRUCTIONS.
ELECTRICAL REQUIREMENTS -120V-1 PHASE
(HARD -WIRE)
ET-1
EXPANSION TANK -WELDED BLACK STEEL
AMTROL(THERM-X-TROL), B&G(PT), ELBI LOT),
CONSTRUCTION, GUARANTEED AIRTIGHT AND
FLEXTRON(FLEXTROL), TACO (PAX SERIES), WATTS
LEAKPROOF, STAINLESS STEEL SYSTEM CONNECTION,
(DETA), WESSELS (TX)
HEAVY DUTY BUTYL DIAPHRAGM AND RIGID
POLYPROPYLENE LINER MECHANICALLY BONDED TO
TANK TO PROVIDE A 100% NON -CORROSIVE WATER
RESERVOIR, DIAPHRAGM AND LINER SHALL BE
APPROVED FOR USE IN POTABLE WATER SYSTEMS, ALL
WETTED COMPONENTS OF FDA APPROVED MATERIALS.
PROVIDE STANDARD SCHRADER AIR VALVE FOR FIELD
CHARGING. TANK SHALL COMPLY WITH FEDERAL ACT
S.3874.
MIN IMUM TANK VOLUME TO BE 2 GALLONS
MINIMUM ACCEPTING VOLUME TO BE 0.9 GALLONS
TANK SHALL HAVE A WORKING TEMPERATURE OF 2006F
AND A WORKING PRESSURE OF 125 PSIG. FACTORY
PRE -CHARGED FOR SHIPPING. FIELD CHARGE TANK TO
55 PSIG.
FCO-1
FLOOR CLEANOUT-ADJUSTABLE, CAST IRON HOUSING,
ZURN (Z1400), JOSAM (55000), MIFAB (C1100), SMITH
ANCHOR FLANGE, TAPERED THREAD PLUG, SECURED
(4000). WADE (6000), WATTS (CO-200)
NICKEL BRONZE TOP. TOP STYLE SHALL MATCH FLOOR
FINISH AS FOLLOWS:
UNFINISHED FLOOR - ROUND SOLID SCORIATED TOP
TILE OR TERRAZZO - ROUND RECESSED TOP
CARPET- ROUND TOP WITH CARPET MARKER.
FD-1
FLOOR DRAIN - CAST IRON BODY, NICKEL BRONZE
FLOOR DRAIN -ZURN (Z415), SMITH (2005), WADE
ADJUSTABLE TOP, 6" ROUND, 4" BOTTOM OUTLET,
It 100), JOSAM (30000), WATTS (FD-100), MIFAB (F1100),
FLASHING COLLAR, DEEP SEAL TRAP.
SUN (FD1000)
TRAP SEAL-W, PLASTIC HOUSING WITH FLEXIBLE
TRAP SEAL - SURE SEAL (SS), PROVENT (TRAP GUARD),
DIAPHRAGM, SEALING GASKETS, RECLUSES AND SEALS
SMITH (QUAD CLOSE), LIQUID BREAKER (GREEN
WHEN DISCHARGE IS COMPLETED, ASSE 1072.
DRAIN)
FS-1
FLOOR SINK -CAST IRON BODY, NICKEL BRONZE RIM AND
ZURN (Z1901), SMITH (3151), WADE (9140), JOSAM
GRATE, 12" SQUARE, 4" BOTTOM OUTLET, 6" DEEP
(49340A), WATTS (FS-740), SIOUX CHIEF (861-2xXFNWC),
RECEPTOR WITH STAINLESS STEEL MESH SEDIMENT
SUN (FS2000)
BUCKET, ACID RESISTANT COATED INTERIOR, SEEPAGE
FLANGE WITH CLAMP, DEEP SEAL TRAP.
CIA
GREASE INTERCEPTOR- UNDERGROUND INSTALLATION,
SCHIER(GREAT BASIN GB-250), MIFAB
POLYETHYLENE, HDPE, OR FIBERGLASS REINFORCED
(XL-MI-G-PL-1150), ZURN GREEN TURTLE(PROCEPTOR
POLYESTER CONSTRUCTION, REMOVABLE OR
GMC300-PDI)
CLEANABLE INTAKE AND DISCHARGE BAFFLES, INTERNAL
FLOW CONTROL FITTING IF NECESSARY FOR OPERATION,
GASKETED H-20 RATED COVER, PDI G101 COMPLIANT, PDI
APPROVED AND LISTED FOR USE, 30 YEAR WARRANTY.
PROVIDE RISERS FOR EXTENDING COVER TO GRADE.
PROVIDE TWO-WAY CLEANOUTS UPSTREAM AND
DOWNSTREAM OF GREASE INTERCEPTOR. PROVIDE
TANK HOLD DOWN SYSTEM AS REQUIRED BY
MANUFACTURER FOR THE SOIL TYPE AND WATER TABLE.
BASIS OF DESIGN SCH IER UNIT DOES NOT REQUIRE TANK
OR FLOW CONTROL VENT PIPING. OTHER GREASE
INTERCEPTOR MANUFACUTURES MAY REQUIRE TAN KANC
FLOW CONTROL FITTING VENT SYSTEMS. THESE
ADDITIONAL SYSTEMS SHALL BE INSTALLED BY THE
CONTRACTOR AT NO ADDITIONAL COST TO THE PROJECT
IF THESE ALTERNATIVE PRODUCTS ARE SUBMITTED AND
INSTALLED.
100 GPM FLOW, 1,076 LB. GREASE CAPACITY, 275
GALLONS HOLDING CAPACITY, 4" PIPE IN LET AND OUTLET.
MB-1
MOP BASIN -PROVIDED BY OTHER AS PART OF KITCHEN
MOP BASIN -FIAT (TSB), ACORN(TSH), CREATIVE
EQUIPMENT PACKAGE.
INDUSTRIES (MC), WILLIAMS (SB)
TRIM- EXPOSED TWO HANDLE MIXING FAUCET, BRASS
TRIM- DELTA(28C2383), AMERICAN STANDARD
CONSTRUCTION, CHROME -PLATED FINISH, SINGLE WING
(8344.012), CHICAGO FAUCETS (897CP), MOEN (8124),
HANDLES, 114 TURN CERAMIC DISC CARTRIDGE, 3/4" HOSE
SPEAKMAN (SC-5812), SYMMONS (S-2490), ZURN
THREAD SPOUT WITH ABBE 1053 RATED INTEGRAL
(Z8411.1141L)
VACUUM BREAKER, WALL BRACE, PAIL HOOK, CHECK
STOPS OR INLINE CHECK VALVES TO PREVENT THERMAL
VACUUM BREAKER -WATTS (SA), OR APPROVED EQUAL
CROSSOVER. FAUCET SHALL COMPLY WITH FEDERAL
ACT S.3874.
ACCESSORIES - MOP HANGER, HOSE AND HOSE
BRACKET, DEEP SEAL TRAP
MV-1
MIXING VALVE -HI/LO MASTER THERMOSTATIC MIXING
LEONARD (TM-LF SERIES), ACORN CONTROLS (SFMV
VALVE ARRANGEMENT FOR TEMPERED WATER CONTROL,
SERIES), APOLLO (34HL), BRADLEY (HL SERIES),
ALL BRONZEMRASS CONSTRUCTION, ROUGH BRASS
LAWLER(800 SERIES), POWERS(LFSH14301LFMM430
FINISH, UNION INLETS WITH STRAINERS, COMBINATION
SERIES), SYMMONS (TEMPCONTROL SERIES 7)
CHECK STOPS OR SEPARATE SUPPLY CHECK VALVES AN
SHUT OFF VALVES, DIAL THERMOMETER ON OUTLET AND
INLETS.
RATED FOR 10 GPM OUTPUT MAXIMUM AT 20 PSI
DIFFERENTIAL AND 5 GPM OUTPUT MINIMUM BASED UPON
CONTINUOUS RECIRCULATION. UNIT TO MIX 140 DEGREE
F HOT WATER SUPPLY AND 40 DEGREE F COLD WATER
SUPPLY FOR 120 DEGREE F OUTLET.
PROVIDE FIELD ADJUSTMENT BY FACTORY AUTHORIZED
REPRESENTATIVE. UNIT SHALL SHALL BE ABBE 1017
ISTE DAPP ED. MBL ALLC LVW
387
RO-1
REVERSE OSMOSIS SYSTEM -MINERAL REDUCTION FOR
EVERPUREMRS-600HE-II
FOOD SERVICE APPLICATIONS. 600 GPD PRODUCTION
RATE. 120 V.
BLADDER TANK- HIGH DENSITY POLYETHYLENE( HDPE)
ROMATE 80
INN ER LINER, FIBERGLASS -WOUND AND EPDXY
RESIN -SCALED OUTER SHELL, 86.7 GALLON CAPACITY.
FILTER HOUSING- POLYPROPYLENE HOUSING WITH
PENTAIRE PENTEK 158008
REINFORCED POLYPROPYLENE CAP. 10" LONG SLIME
LINE CONFIGURATION.
CIRCULATION PUMP - 10 GPM AT 25 FEET OF HEAD.
MOTOR SHALL BE 3/4 HP. ELECTRICAL REQUIREMENTS
120 V 1 PHASE.
RELEASED FOR CONSTRUCTION
Subject to compliance with all milulatims
of State and Local Codes
City of Cannot
PLUMBING FIXTURE SCHEDULE
TAG NAME
DESCRIPTION
MANF. & MODEL
SK-1
SINK- PROVIDED BY OTHER AS PART OF KITCHEN
INSULATION KIT- MCGUIRE(PROWRAP), JUST(J-ADA),
EQUIPMENT PACKAGE.
PLUMBEREX (PRO -EXTREME), TRUEBRO (LAV-GUARD2)
SINK TRIM - PROVIDED BY OTHER AS PART OF KITCHEN
EQUIPMENT PACKAGE.
ACCESSORIES -1-1/2" 17 GAUGE CHROME -PLATED BRASS
TAILPIECE AND P-TRAP, QUARTER -TURN BALL VALVE TYPE
3/8" CHROME -PLATED BRASS ANGLE SUPPLIES WITH
LOOSE KEY STOPS, CHROME -PLATED SOFT COPPER
SUPPLY LINES.
INSULATION KIT - PRE -MANUFACTURED FOR P-TRAP, STOP
VALVES, AND SUPPLY LINES.
SK-2
SINK- PROVIDED BY OTHER AS PART OF KITCHEN
INSULATION KIT- MCGUIRE(PROWRAP), JUST(J-ADA),
EQUIPMENT PACKAGE.
PLUMBEREX (PRO -EXTREME), TRUEBRO (LAV-GUARD2)
SINK TRIM - PROVIDED BY OTHER AS PART OF KITCHEN
EQUIPMENT PACKAGE.
ACCESSORIES -1-1/2" 17 GAUGE CHROME -PLATED BRASS
TAILPIECE AND P-TRAP, QUARTER -TURN BALL VALVE TYPE
3/8" CHROME -PLATED BRASS ANGLE SUPPLIES WITH
LOOSE KEY STOPS, CHROME -PLATED SOFT COPPER
SUPPLY LINES.
INSULATION KIT - PRE -MANUFACTURED FOR P-TRAP, STOP
VALVES, AND SUPPLY LINES.
TD-1
TRENCH DRAIN- PROVIDED BY OTHER AS PART OF
KITCHEN EQUIPMENT PACKAGE.
UB-1
UTILITY BOX -GALVANIZED STEEL ENCLOSURE, ANGLE
GUY GRAY (BIM875AB), OATEY (39140)
VALVE WITH 11W COMPRESSION OUTLET, INTREGAL
WATER HAMMER ARRESTOR.
UB-2
UTILITY BOX (NATURAL GAS)- WHITE POWDER COATED
TRACPIPE(FGP-WBTM-750)
STEEL CONSTRUCTION, 5"W BY5"H BY 3-1/8"D BOX
DIMENSIONS, 3/4" PIPE SIZE, BRASS ANGLE SHUT OFF
VALVE
LOW LEAD 1/4 TURN SHUT OFF VALVE WITH INTEGRAL
WATER HAMMER ARRESTOR, 6 FOOT STAINLESS STEEL
FLEXIBLE HOSE FOR CONNECTION TO EQUIPMENT.
WHA
WATER HEATER- OWNER FURNISHED, CONTRACTOR
A.O. SMITH(DRE-120)
INSTALLED. ELECTRIC, VERTICAL, METAL CABINET, BAKED
ENAMEL FINISH, GLASS -LINED ASME STAMPED WELDED
STEEL TANK, 150 PSI WORKING PRESSURE, FIBERGLASS
OR FOAM INSULATION, BRASS WATER CONNECTIONS AND
DRAIN VALVE, ASME APPROVED T&P RELIEF VALVE,
MAGNESIUM ANODE ROD, INDIVIDUAL FLANGE -MOUNTED
IMMERSION HEATING ELEMENTS SHEATHED WITH
CORROSION -RESISTANT METAL ALLOY, EXTERNALLY
ADJUSTABLE AUTOMATIC IMMERSION WATER
THERMOSTAT, MANUAL RESET HIGH TEMPERATURE
CUTOFF SWITCH, ENCLOSED CONTROLS, VENTILATED
CONTROL CABINET, PILOT LIGHTS INDICATING MAIN
POWER AND HEATING STEPS, CONTROL CIRCUIT TOGGLE
SWITCH, SEQUENCING STEP CONTROLLER, CONTROL
TRANSFORMER, POWER CIRCUIT FUSES, MAGNETIC
CONTACTORS, CERAMIC TERMINAL BLOCK, FACTORY
ASSEMBLED AND WIRED, 3-YEAR WARRANTY, UL LISTED,
NEC COMPLIANT ELECTRICAL COMPONENTS, COMPLIANT
TO NAECA, ASHRAE 90.1 AND ASHRAE 90A.
119 GALLON CAPACITY, 18 KW ELEMENT(S), 148 GPH
RECOVERY RATE AT 50-F TEMPERATURE RISE. HEATING
ELEMENTS RATED FOR LESS THAN 75 WATTS PER
SQUARE INCH.
ELECTRICAL REQUIREMENTS -480 VJ PHASE HEATING
CIRCUIT, 120V CONTROL CIRCUIT.
®IMEG o� O �ewau,,a
■■
QAPAMCAN
®■ STRUCTUREPOINT
7260 SM1adeland Somon I Indianapolis, Indiana M256
TEL 317.M7.55M I FAx31].503.02]0
www.aminurepoim.00m
*IMEG
8900 KEYSTONE XING PH: 317.848.5045
SUITE 210 FAX 317.844.2201
INDIANAPOLIS, IN www.imegeorp.com
46240
GEICO CORPORATE
FIRST FLOOR
RENOVATION PHASE 3
101 W. 103RD ST.
INDIANAPOLIS, IN 46290
No. "`,`*
* / PE105050 ' \
STATEOF�;
ND I.A ...
CERTIFIED BY
ISSUANCEINDEX
DATE:
06/14/19
PROJECT PHASE:
CONSTRUCTION DOCUMENTS
PHASE 3
REVISION SCHEDULE
NO. I DESCRIPTION I DATE
Project Number 18002480.01
SCHEDULES
DATE: 09/24/19
MEG GVRP RESERVES FROPRAII
VPLPNG PARTLPATICN OF II LONP. 0A1811AEGCGRP.
REFERENCESGVE IN INI
a 1