Loading...
HomeMy WebLinkAboutA000.5PLOTTED: January 4, 2017 / Annie Ki / 2450-BOURGES-MZ-BASE-EL-NC2G.DWG A3-NC2G 3FB.4Northern Craftsman 2G3 Car Front EntrySide and Rear Elevation, Roof Plan and Attic Ventilation Schedule1900 E. Golf Road, - Suite 300Schaumburg, Illinois 60173Midwest Zone Office108/05/2016BID SET REVISIONS209/02/2016ADDITIONAL ELEVS.309/14/2016ADDITIONAL ELEVS.410/28/2016REVISIONS512/28/2016REVISIONS............ PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2016 EM/ER06/13/2016 LEFT BOURGES 2450.300.00.CPM -- 12/28/2016SCALE:ROOF PLAN1/8" = 1'-0"- 7:12 6:12 "A"2963ROOF AREA:SQ. FT. \A1;34'-0" \A1;4'-0" OPT. POT VENTS \pxql;PROVIDE ADEQUATE OPENING FOR AIR MOVEMENT BETWEEN ATTIC SPACES TO SUPPORT REQUIRED VENTILATION \A1;1'-0"\PTYP. OPT. GUTTER & DOWNSPOUTS \A1;4'-0"\A1;4'-10"\A1;1'-0" \A1;1'-0"\PTYP. "B"202ROOF AREA:SQ. FT. \A1;3'-0" 6:12 7:12 9:129:12 5.5:129:129:12 3.5:12 1TOP OF FOUNDATION TOP OF PLATE TOP OF PLATE \A1;9'-1{\H0.750000x;\S1#8;}"\A1;OPT. 10'-1{\H0.7x;\S1#8;\H1.4286x;" }\A1;8'-2{\H0.750000x;\S7#8;}"\A1;9'-2{\H0.7x;\S7#8;\H1.4286x;" @ OPT. 10' PL.} \A1;8'-1{\H0.750000x;\S1#8;}"\A1;OPT. 9'-1{\H0.7x;\S1#8;\H1.4286x;" }\A1;7'-2{\H0.750000x;\S7#8;}"\A1;8'-2{\H0.7x;\S7#8;\H1.4286x;"@ OPT 9' PL} SCALE:RIGHT ELEVATION1/8" = 1'-0"- \A1;OPT. MASONRY WRAP\A1;OPT. MASONRY RETURN 1 126 127 125.5 123.5 \A1;OPT.4 44 SCALE:LEFT ELEVATION1/8" = 1'-0"- 612 OPT. MASONRY WAINSCOT \A1;OPT. MASONRY RETURN 1 126 127 125.5 OPT. \A1;OPT.4 TOP OF FOUNDATION TOP OF PLATE TOP OF PLATE \A1;9'-1{\H0.750000x;\S1#8;}"\A1;OPT. 10'-1{\H0.7x;\S1#8;\H1.4286x;" }\A1;8'-2{\H0.750000x;\S7#8;}"\A1;9'-2{\H0.7x;\S7#8;\H1.4286x;" @ OPT. 10' PL.} \A1;8'-1{\H0.750000x;\S1#8;}"\A1;OPT. 9'-1{\H0.7x;\S1#8;\H1.4286x;" }\A1;7'-2{\H0.750000x;\S7#8;}"\A1;8'-2{\H0.7x;\S7#8;\H1.4286x;"@ OPT 9' PL} SCALE:REAR ELEVATION1/8" = 1'-0"- OPT. MASONRY WAINSCOT ELEVATION NC2G ATTIC VENT SCHEDULE VENTILATION REQUIRED AND SUPPLIED IS BASED ON POT VENT VALUES AND RIDGE VENT VALUES SHOWN IN TABLE ABOVE ** CONTRACTORS INSTALLING VENTILATION ARE RESPONSIBLE FOR VERIFYING THAT VENTS USED WILL SUPPY VENTILATION TO MEET CODE REQUIREMENTS * SCHEDULE HAS BEEN CALCULATED ASSUMING EAVE VENTILATION AT 50-60% OF TOTAL AND RIDGE AT 40-50% OF TOTAL REQUIRED VENTILATION ROOF AREA "A"SQ FTG 2968 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 3.96 4.95 4.66 46.89 11 0 AT EAVE 5.94 4.95 5.28 53.11 0 76.00 TOTAL (MIN)9.89 9.89 9.94 100.00 3 HIGH - RIDGE VENT 3.96 4.95 4.75 48.03 0 0 38.00 AT EAVE 5.94 4.95 5.14 51.97 0 74.00 TOTAL (MIN)9.89 9.89 9.89 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE ROOF AREA "B"SQ FTG 202 AT / NEAR RIDGE AT / NEAR EAVE VENT TYPE SQ. FT. REQUIRED RANGE SQ. FT. SUPPLIED PERCENT OF TOTAL SUPPLIED POT LARGE (SQ. IN. EACH) POT SMALL (SQ. IN. EACH) RIDGE VENT (SQ. IN. PER LF) EAVE VENT (SQ. IN. EACH) CONT. VENT (SQ. IN. PER LF) 61.00 40.00 18.00 28.00 10.00 HIGH - POT VENTS ONLY 0.27 0.34 0.42 46.56 1 0 AT EAVE 0.40 0.34 0.49 53.44 0 7.00 TOTAL (MIN)0.67 0.67 0.91 100.00 3 HIGH - RIDGE VENT 0.27 0.34 0.38 47.37 0 0 3.00 AT EAVE 0.40 0.34 0.42 52.63 0 6.00 TOTAL (MIN)0.67 0.67 0.79 100.00 ADDITIONAL POT VENTS MAY BE REQUIRED IF THERE IS INSUFFICIENT RIDGE AVAILABLE 09/23/19 William Hohlt