HomeMy WebLinkAboutSHW 019 - Energy Certificate2614 LACEWOOD CT CARMEL, IN 46074 Builder: PULTE HOMES 11!, 0 Pi Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls N/A Framed Floor R-30 Slab R-10.0 Perimeter, R-10.0 Under Infiltration 5 ACH50 Window U-Value: 0.31, SHGC: 0.28 Building Features Duct Supply R-30.0, Return R-30.0 Duct Leakage to Outside 175 CFM25 (5.041100 s.f.) Total Duct Leakage 464 CFM25 (Post -Construction) Heating Furnace • Natural Gas • 93 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certlfy that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name Michael Hill Organization: TSI Energy Solutions Signature: Date: 919119 at 2:42 PM Ekotrope RATER - Version 3.1.0.2247 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report.