HomeMy WebLinkAboutMoschell New FloorplanC01C01C03C03C01C01 C03C03
C02C02 C02C02
D01D01
D04D04
D01D01
D03D03
UPcL
E1E1
Elevation 1
E2E2
Elevation 2
14'-8"2'-3"7'
1 0'-5 1 /2" 6'-2"1 2'-2 3/4"
9 3/4"
1 1 '-7 1 /2"8'-11"5'-4 1/2"1 226 SQ FT
LIVING AREA
UTILITY
BEDROOM 1
BATH
LIVING
Support Beam Support Post
Bulk Head
Bulk Head
Support Beam
Bulk Head
Not in Construction Area
11
22
11
11
44
55
44
66
77
77
##
1. ) Carpet to be installed by home owner
coordinated by contractor.
2. ) Exercise mat flooring to be supplied
and installed by other.
3. ) Frame new 6" interior wall around
existing support post.
4. ) Frame out and drywall bulkheads to
cover existing support beams and
mechanical.
5. ) Re-frame and build out bottom two
stairwell steps per the design
submitted. See Detail
6. ) Install single shelf and rod.
7. ) Install new casing and trim on existing
windows.
8. ) Build out 4" standard stud wall from
floor to ceiling.
9. ) Build out 6" standard stud wall from
floor to ceiling.
10. ) Hang, finish and paint new drywall on
all walls and ceiling.
11. ) Non construction area to not have
drywall installed.
12. ) Install LVT flooring per the design
submitted.
13. ) Install new fiberglass tub / shower unit
in existing plumbing location.
14. ) Install new toilet in existing plumbing
location.
15. ) Install new vanity cabinet with
laminate top and drop in sink.
16. ) Install HVAC supply air drop sized per
the room size from ceiling.
17. ) Install HVAC return air grill in wall per
the room size.
18. ) Stairs to be carpeted by homeowner
coordinated by contractor.
19. ) Relocate metal support post per the
design submitted.
20. ) Install access panel for water main
approx. 30"x42" in size.
21. ) Install grinder pump and connect to
existing drainage system.
88
88
88
88
88
88
1 919
88
88
88
88
99
1 010
1 010
1 010
1 010
1 010
1 111
1 212
1 313
1 414
1 515
1 616
1 717
Push to Corner
Push to Corner
Push to Corner
44
8'-10" Finished Ceiling Height
8'-10" Finished Ceiling
Height
8'-10" Finished Ceiling Height
1 818
7'-10" Finished
Ceiling Height
1 919
Water Main
2020 88
2121
2x SILL
2x FRAMING MEMBER
INTERIOR FINISH
DOUBLE TOP PLATE APPROVAL SIGN OFFCLIENT DATE SITE MANAGER INITIALSSHEET:
SCALE:DRAWINGS PROVIDED BY:DATE:
9 /17/2019BasementMoschell Family12642 Teaberry LaneCarmel, IN 46032IA-3
3/8" = 1'-0"Custom Home Medic1093 3rd Ave South WestCarmel, IN46032New Floor Plan
2x SILL
2x FRAMING MEMBER
INTERIOR FINISH
DOUBLE TOP PLATEEXISTING
FOUNDATION WALL
EXISTING
INSULATION
INTERIOR WALL SECTION (typ)
Not to Scale
INTERIOR WALL SECTION (typ)
Not to Scale
09/23/19
William Hohlt