HomeMy WebLinkAboutC-109 Utility DetailsMARKER EXTENDED FROM / / ALL PIPE, EXCEPT RISER PIPE,
END OF LATERAL TO MIN. / / SHALL BE LAID TO A UNIFORM
3' ABOVE GRADE. / \ GRADE OF AT LEAST 1 /8" PER
FOOT FOR 6" DIAMETER PIPE.
RISER SECTION SHALL BE NO
/ THAN A LENGTH WHICH \
MARKER EXTENDED FROM / / / / / /LONGER
OB WOULD A LO ASA SERVICE
AT LATERAL \
END OF LATERAL TO MIN.
3' ABOVE GRADE. / \ \ THE PROPERTY LINE I
/ MINIMUM GRAD ECTION
\ \
1/8 PER FOOT,/ / \ /
/ FOR 6 DIAMETER / \\ RISER S
/ LATERALS I / � / \
\ / PROPER FITTINGS SHALL BE USED ,
FOR ALL ABRUPT CHANGES IN\ �\
\LINE OR GRADE.
BELL HOLES SHALL BE PROVIDED
AND THE TRENCH PREPARED SO
THAT LOWER HALF OF PIPE IS
PROPERLY SUPPORTED THROUGHOUT
ITS LENGTH.
HOUSE CONNECTION TO MAIN SEWER
SLOPE CONCRETE TO DRAIN
AWAY FROM C.O.
6"
6" CONCRETE PAD
f-
3500 PSI
I
I
r
r
45' BEND
WYE
r
r
6" MIN. OF GRANULAR
-
BACKFILL (3/4" CLEAN
`-
CRUSHED ROCK)
HEAVY DUTY FRAME & COVER
W/ LETTERS "C.O." CAST IN COVER
PER LOCAL STANDARDS.
THE COVER & CONCRETE SHALL HEAVE
FREELY ON THE PVC PIPE DURING
FREEZE/THAW PERIODS.
--THREADED PVC CLEANOUT PLUG
FINISH GRADE
GRANULAR BACKFILL
( OCK) LEAN CRUSHED
PLUG WYE IF SERVICE LATERAL
DOES NOT CONTINUE
III III FLOW
UNDISTURBED EARTH
NOTE:
CLEANOUTS REQUIRED ON SANITARY SEWER SERVICE LATERALS
AT 5' OUTSIDE BUILDINGS (2—WAY C.O.), EVERY CHANGE IN
HORIZONAL & VERTICAL DIRECTION GREATER THAN 45° &
AT 100' INTERVALS.
CLEANOUT
HOUSE CONNECTION FOR DEEP SEWERS
APPROVED BACK FILL AS PER
INSTALLATION SPECIFICATIONS
FOR PAVED OR NONPAVED
SURFACES.
WI,1111
RUN UPWARD AT 6" MINIMUM
APPROX. 45`
SERVICE LATERAL NOTES:
1 ) NORMAL SERVICE LAT. SLOPE IS 1 /4" / FT.
2) MIN. SERVICE LAT. SLOPE IS 1 /8" / FT.
3) MIN. SERVICE LATERAL MATERIAL SHALL BE
SDR 26 OR SCH. 40.
4) VERIFY SLOPE & MAT'L REQUIREMENTS W/
LOCAL BUILDING INSPECTOR & UTILITY DEPT.
5) INSTALL DETECTABLE LINE MARKING TAPE WITH
14-GUAGE COPPER TRACING WIRE ALONG THE
COMPLETE LENGTH OF ALL LATERAL LINES
(AND FORCE MAINS)
BEDDING UP TO
SPRING LINE OF PIPE
BEDDING MATERIAL SHALL BE
CRUSHED STONE; MINIMUM NO. 1 1 ,
MAXIMUM NO. 5, AND SHALL BE
_ MECHANICALLY HAND TAMPED.
ATTACH 45° CURVE, OR ELBOW DIRECTLY TO "TEE-WYE"
SECTION ON MAINLINE SEWER (NO RISER SECTION).
--- 6" SERVICE LATERAL
TEE OR TEE-WYE SECTION ON MAINLINE SEWER
FOR SHALLOW SEWERS
THE CONTRACTOR SHALL CAP
THE END OF EACH SERVICE L
WITH THE APPROPRIATE FITTIN
FOR THE TYPE OF PIPE USES
6" SERVICE LF
30• MIN. 6" SERVICE LATERAL
ATTACH 45° CURVE, OR ELBOW TO RISER SECTION
ATTACH RISER SECTION TO "TEE-WYE" SECTION ON MAINLINE SEWER
TEE OR TEE-WYE SECTION ON MAINLINE SEWER
FOR DEEP SEWERS ONLY
LATERAL INSTALLATION
FOR ALL SERVICE CONNECTION LATERALS
LATERAL CONNECTIONS
WATER MAIN
WATER MAIN
aAraln
WHEN MININUM WATER AND SEWER (STORM & SANITARY) MAIN CLEARANCE DIMENSIONS CANNOT
BE ACHIEVED, WATER AND SEWER PIPE SHALL BE CONSTRUCTED OF SLIP—ON
OR MECHANICAL JOINT PIPE COMPLYING WITH AWWA DESIGN STANDARDS AND
BE PRESSURE RATED AND TESTED TO 150 PSI TO ASSURE WATER TIGHTNESS
PRIOR TO BACKFILLING. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM
THE WATER & SEWER DEPTS. PRIOR TO INSTALLING ANY PIPE WHICH EXCEEDS
THESE MINIMUM HORIZONTAL (10') AND VERTICAL (18") CLEARANCES.
WATER I& SEWER SEPARATION
LATERAL ALIGNMENT
LIMIT OF SUBGRADE
FINAL BACKFILL
SHALL BE PER
NOTE 1.
BEDDING, HAUNCHING,
TRENCH WIDTH, INITIAL
BACKFILL MATERIALS,
PLACEMENT, AND
COMPACTION PER
STANDARD PRACTICE
OF UTILITY HAVING
JURISDICITON OVER
INSTALLATIOIN.
SERVICE LATERAL
111111=001KN/M:1
NICE LATERALS TO BE ALIGNED
90° WITH RESPECT TO MAINLINE
VER.
OR TEE-WYE SECTION ON
NLINE SEWER
0
GE MEASUREMENTS TO BE MADE
MANHOLE TO CENTERLINE OF
;E LATERAL.
6" MINIMUM OF TOPSOIL OR COMPACTED
AGGREGATE #53
L PAVEMENT SECTION VARIES I
MINIMUM COVER SHALL
BE PER NOTE 3.
PIPE MATERIAL PER UTILITY
HAVING JURISDICTION OVER
INSTALLATION.
WA TER & SEWER MAIN AND LA TERA L TRENCH DETAIL
FOR UTILITY INSTALLATIONS WITHIN CITY R/W
NOTES: NO SCALE
1. FINAL BACKFILL FOR UTILITY INSTALLATIONS WHERE 1" IS 5' OR LESS SHALL BE B—BORROW FOR STRUCTURE BACKFILL
MEETING THE MATERIAL REQUIREMENTS OF THE INDOT AND SHALL BE COMPACTED IN 6" MAXIMUM LIFTS TO NOT LESS
THAN 95% STANDARD PROCTOR DENSITY FOR THE ENTIRE DEPTH OF THE MATERIAL PLACED. THE BACKFILL FOR THE
TOP 6" OF THE EXCAVATION BELOW THE LIMIT OF SUBGRADE SHALL BE #53 STONE MEETING THE MATERIAL REQUIREMENTS
OF THE INDOT AND SHALL BE COMPACTED TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY FOR THE ENTIRE
DEPTH OF THE MATERIAL PLACED. IF THE STANDARD PRACTICE OF THE UTILITY THAT HAS JURISDICTION OVER
THE INSTALLATION HAS A MORE STRINGENT FINAL BACKFILL REQUIREMENT, THE MORE STRINGENT REQUIREMENT
WILL GOVERN. CONTRACTOR SHALL PROVIDE A 3rd PARTY TESTING AGENCY TO PROVIDE COMPACTION TESTING AS
NECESSARY.
2. THIS REQUIREMENT SHALL APPLY FOR ALL UTILITY INSTALLATIONS (INCLUDING BUT NOT LIMITED TO WATER
MAINS, WATER SERVICE LATERALS, SANITARY MAINS, SANITARY SERVICE LATERALS, GAS PIPING, POWER, TELECOMM
AND CATV CONDUITS OR DUCT BANK) WITHIN EXISTING AND PROPOSED CITY OF CARMEL R/W LIMITS.
3. FOR UTILITY INSTALLATIONS UNDER CITY STREETS, REGARDLESS OF THE JURISDICTION OF THE UTILITY, THE MINIMUM
COVER FROM THE TOP OF THE INSTALLED PAVEMENT OR FINAL GROUND ELEVATION TO THE TOP OF THE INSTALLED PIPE
CONDUIT OR DUCT BANK SHALL BE NO LESS THAN 2.5 FEET. IF THE STANDARD PRACTICE OF THE UTILITY THAT HAS
JURISDICTION OVER THE INSTALLATION HAS A MORE STRINGENT COVER REQUIREMENT, THE MORE STRINGENT REQUIREMENT
SHALL GOVERN.
4, IF EXISTING SUBGRADE HAS BEEN LIME STABILIZED, BACKFILL WITH B—BORROW TO BOTTOM OF EXISTING SUBGRADE
AND FILL TO THE LIMIT OF TREATED SUBGRADE WITH COMPACTED AGGREGATE, NO 53.
STANDARD CITY OF CARMEL STANDARDS
DRAWING WATER &SEWER MAIN AND LATERAL TRENCH DETAIL
10-32 FOR UTILITY INSTALLATIONS WITHIN CITY R/W
This drawing and/or specifications is provided as an instrument of service
provided by Cash Waggner & Associates, PC and is intended for use on this
402 EAST 1 3TH STREET
N ❑.
DATE
BY
DESCRIPTION
WILLOW HAVEN SENIOR HOMES
DATE:
project only. All drawings, specifications, designs, models, ideas, calculations,
and arrangements appearing herein constitutes the original and unpublished
Work of and remains the property of Cash Waggner & Associates, PC. Any
`A` G A`
SUITE 1 O 1
JASPER, IN I 47546
(n
PROJECT NO.:I 19-3957
PROJECT:
MEMORY CARE HOMES
• ■
9 9 9
Q
mm.dd.yy
INI
Description
reproduction, use or disclosure of the proprietary information contained herein
without the prior written consent of the Cash Waggner & Associates, PC is
`v `v
ENS G�
CASH W A G G N E R P 8 1 2. 6 3 4. 5 0 1 5
z
❑
DESIGNED BY:
I N RW
ADDRESS:
1 3 1 4 S WEST ROAD
DRAWN BY: DIM
I I I
DRAWING No.:
strictly prohibited.
Written dimensions shown hereon shall take precedence over scaled dimensions.
p v
O
H:
FAX: 8 1 2. 6 3 4. 5 0 1 7
U1
CARMEL , I N D I A N A 4 6 O 7 4
Contractors shall calculate and measure required dimensions. Notify Cash1.3964_
Waggner & Associates, PC with any variations in dimensions or conditions from
those indicated these drawings. This drawing based
�� p,P R G /� /�
O"
CELL. 8 1 2.6 3
Sc A S S E3 C 1 A T E S,
W
0
FILENAME:
13957Util-Detl
on was on available
information. Commencement of Work constitutes verification and acceptance of
�(// �(//
NO
Pr_ EMAIL: N WAG G N ER@
Q
LAYOUT TAB:I Layout
UTILITY
0
I�
SCALE:IAsShown
existing conditions.
C A S H WAG G N E R. C❑ M
CONSULTINGIENGINEERINGISURVEYING
SHEET TITLE:
Application of a material or equipment to Work installed by others constitutes
acceptance of that Work and assumption of responsibility for satisfactory
S I G N AT Ll R E DATE
CAS wAG
D E T A I L S
rj
1 2
installation.
W W W. H G N ER. C❑ M
Q
❑ F: