HomeMy WebLinkAboutC2 Proposed Site PlanCONCRETE NOTES 1. ACI 318, "BUILDING CODE REQUIREMENTS FOR REINFORCE CONCRETE": COMPLY WITH APPLICABLE PROVISIONS EXCEPT AS OTHERWISE INDICATED. SITE DATA 2. EMPLOYLABORATORY i0 PERFORM MATERIALS EVALUATION, TESTING AND SEE ARCH PLANS FOR INTERIOR LAYOUT, I NOF CONCRETE CRT MIXES. AND BUILDING DIMENSIONS ZONED OT-OL 3, PERFORM SAMPLING AND TESTING DURING CONCRETE PLACEMENT, AS FOLLOWS: A. AIR CONTENT ASTM C 173. ONE FOR EACH SET OF COMPRESSIVE STRENGTH SPECIMENS, 6% LOT AREA 0 25} Ac MINIMUM ON ALL CONCRETE EXPOSED i0 FREEZING OR THAWING. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN PROPOSED BUILDING AREA FOOTPRINT (FOOTPRINT) 1,445 SO. Fi. B. COMPRESSIVE STRENGTH ASTM C 39, ONE EACH 50 CU. YDS. OR FRACTION THEREOF APPROVED STORM WATER MANAGEMENT PERMIT. II DISTURBED AREA 7,700t S0. FT. EACH CLASS OF CONCRETE; ONE SPECIMEN TEN TESTED AT 7 DAYS, ONE SPECIMEN TESTED I AT 28 DAYS, AND ONE RETAINED FOR LATER TESTING IF REQUIRED. PROVIDE 60'-131T'PVC CONDUITS VIDE 60 B)Z' PVC CO DU1IZE II EXISTING PARKING ] C. WHEN THE TOTAL QUANTITY OF GWEN CLASS OF CONCRETE IS LESS THAN 50 CU. YDS. TO & A PROPOSED ADA PARKING PROPOSED 1 STRENGTH TESTS MAY BE WAIVED BY ENGINEER IF FIELD EXPERIENCE INDICATES EVIDENCE OF LOCATION WITH UTILITY I TOTAL PARKING 10 SATISFACTORY STRENGTH. BART L. FOUR COORDINATE RELOCATING GUY STREET PARKING 4 D. TEST RESULTS WILL BE REPORTED IN WRITING TO ENGINEER OR GENERAL CONTRACTOR. WIRES WITH DUKE ENERGY NO. 2UDS26488 II CONTACT THE CONCRETE PRODUCER WITHIN 24 HOURS AFTER TESTS ARE MADE. MINIMUM FRONT YARD SETBACK 0' 4. CONCRETE FOR PAVEMENT, FOUNDATION, SLABS, WALKS, PATIOS, AND CURBS SHALL HAVE A 28 SIMEON HAWKINS ADDI110N NATHAN HAWKIN'S LOT11 ,.I CARMEL COMMERCIAL DRIVE LOT I I I II APPROACH INR/W SEE DETAIL MINIMUM REAR YARD SETBACK MINIMUM SIDE YARD SETBACK 15• to' DAY COMPRESSIVE STRENGTH OF NOT LESS THAN 4,000 PSI FOR ALL EXTERIOR POURED CONCRETE. Q9 EX. STANITNtY SEWER 200 T.O.C.-Iii GI 42" RCP E•83.64' - 42`R081 j,64 PARKING SPA - - -_APPROXfMAiEEPH'dL. F. "DOMESTIC- SERVICETOBEWETTAPPEDINTOExISTING. MAIN PROVIDE A CURBSTOP AND CURBSTOP BOX WITHIN S'OFTAP VERIEBy D m LOCATION 6" BARRIER CURB SEE I I I DETAIL ON SHEET C5.2 u GAS VALVE PND CONNECTION VERIFY u CRY OF CARMEL TYPE, SIZE AND LOCATION WITH UTIUTY 3 INSTR, NO. 2017-10010 ¢ II CRY OF CARMEL a Hm REDEVELOPMENT XLI COMMISSION A vl O II 0.095 Ac. I SIMEON HAWKINS ADDITION I INSTR. NO. 2007-126111 m P LOT 10 1 PARKING BLOCK RYP) IL IL e I8.0' S. v III I PROPOSED DOM STI METER SEES/ TH METER AND BAC L CRY OF CARMEL I INTERIOR) VERIF TY INSTR. NO. 2017-10010 LOCATION W DH A w I Q I o I SIMEON HAWKINS ADDITION LOT ON SHEET C5.2 EX. STORM SEWER 389 - - - - - - 5. MIX DESIGN MAY BE ADJUSTED WHEN MATERIAL CHARACTERISTICS, JOB CONDITIONS, WEATHER, ,�. T.O.C. 82Z.68' EXISTING BUILDING (FOOTPRINT) 2120t SOFT. TEST RESULTS OR OTHER CIRCUMSTANCES WARRANT. DO NOT USE REVISED CONCRETE MIXES 15" RCP 14=819.00' IMPERVIOUS AREA 8,6222 SQ.FT. UNTIL SUBMITTED TO AND ACCEPTED BY ENGINEER. _ _ _ _ _ _ _ _ _ _ _ _ 15' RCP w•819.00' LOT COVERAGE 80% REQUIRED.MENT ASTIR! C 150, TYPE AS EEXCEPTT _ NORTH STREET EX. STANIFARY SEWER 549 T0C•826BY 7. ASTM C 33, LOCAL AGGREGATES OF PROVEN CURABILITY MAY BE USED WHEN L (15TST.NW) ADARFDRIVE H "' SIDE OF DRIVE I1 R/WI AIQ� e•/T7'�7_ r tCG S a s ADA; RAMP 12.6' I INTERIOR RPZ C5.2 W- SIZE, & BE WATER. RESNAZ, LLC NO. 20089945 I I I - - - - - - - - - - - - _ - - I I LEGEND VINE REAL ESTATE HOLDING, LLC 3 NEW CONCRETE SIDEWALK CT CART SEE DETAIL ON SHEET C5.2 TYPE. SR &LOCATIONONT WITH LET TRY In®p EXISTIFRAMES N 66 COVERED BIKE I STORY ASO R ;,X PARKING SEE REAR N BUILDING Ipt� DETAIL I/C6 OI&u NEW BRICK LLJ 40 a 01r SIDEWALK W Ii GAS E IFY Ix L 1 Dill i TYPE, &L CATION WITH r jT0 ILOY BINIW (n LU 2 ZZ 1--1 Q - �10 Lns+wc Wo00 wA RAMP ON R W LK ox NEW BRICK - NEW 5STAIRS TO WALK _ SIDEWALK G L NEW GAS SERVICE TO NEW METER I ORIGINAL TOWN OF BETHLEHAM NOW CARMEL LOT 13 I 10' ALLEY I S® m STORM INLETS 1' PROPOSED CONTOUR LINE ® STORM MANHOLE 5' PROPOSED CONTOUR LINE if SOIL BORING ��-�------ 1' EXISTING CONTOUR LINE 0 UTILITY POLE � � - - � 5' EXISTING CONTOUR LINE p9 WATER VALVE - GAS EXISTING GAS LINE QT PHONE MANHOLE PROPERTY LINE • UTILITY PEDESTAL _ _ ADJOINER/SECTION LINE FIRE HYDRANT O MANHOLE -'-'- RIGHT-OF-WAY LINE - CENTERLINE °CO CLEAN OUT OW WATER METER SETBACK LINE 0 LIGHT POLE EASEMENT BOLLARD E EXISTING UNDERGROUND ELECTRIC LINES ELECTRIC METER OHP EXISTING OVERHEAD UTILITY LINES OD GAS METER + EXISTING UNDERGROUND PHONE pd GAS VALVE TO EXISTING TELECOMMUNICATIONS w EXISTING WATER LINE EXISTING SIDEWALK PAVERS SANITARY SEWER LINE - - - - STORM SEWER EXISTING CONCRETE SAW CUT ••• FLOW LINE W PROPOSED WATER LINE PROPOSED ASPHALT SEE DETAIL 21 PROPOSED SANITARY SEWER LINE iiii sm m PROPOSED STORM SEWER c PROPOSED GAS SERVICE E PROPOSED UNDERGROUND ELECTRIC iiiiiiiiiiiiiiiiiin F[Iiiiiiiiiiiiiiiiiiiis PROPOSED FIBER OPTIC RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �VTUJ'�GW1L'AWML DATE: \ 09/24/19 SITE NOTES- I I. SITE INFORMATION WAS TAKEN FROM KEELER-WEBB ASS., DATED 05/09/2018. IT IS THE CONTRACTOR'S RESPONSIBILITY i0 VERIFY EXISTING SITE CONDITIONS PRIOR TO STARTING WORK. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING OR VERIFYING THAT ALL PERMITS AND APPROVALS ARE OBTAINED FROM THE RESPECTIVE CITY, COUNTY, AND /OR STATE AGENCIES PRIOR i0 STARTING CONSTRUCTION. 3. THE PLUMBING CONTRACTOR SHALL CONSULT WITH THE LOCAL WATER COMPANY, PROVIDE ALL MATERIALS AND LABOR, AND PAY ALL COSTS NOT BORNE BY THE LOCAL WATER COMPANY TO PROVIDE ANY NEW WATER SERVICE. 4. THE PLUMBING CONTRACTOR SHALL CONSULT WITH THE LOCAL GAS COMPANY, PROVIDE ALL MATERIALS AND LABOR, AND PAY ALL COSTS NOT BORNE BY THE LOCAL GAS COMPANY TO PROVIDE ANY NEW GAS SERVICE. 5. THE ELECTRICAL CONTRACTOR SHALL CONSULT WITH THE LOCAL POWER COMPANY, PROVIDE ALL MATERIALS AND LABOR, AND PAY ALL COSTS AND FEES NOT BORNE BY THE LOCAL POWER COMPANY i0 PROVIDE ANY NEW UNDERGROUND ELECTRICAL SERVICE. 6. THE ELECTRICAL CONTRACTOR SHALL CONSULT WITH THE LOCAL TELEPHONE COMPANY, AND SHALL PROVIDE ALL LABOR AND MATERIALS REQUIRED WHICH ARE NOT BORNE BY THE TELEPHONE COMPANY i0 PROVIDE ANY NEW TELEPHONE SERVICE. 7. UNDERGROUND WATER MAIN EXTENSION SERVICE SHALL BE AWWA C900 PVC OR DUCTILE IRON. DOMESTIC WATER LATERAL SERVICE SHALL BE TYPE 'K' COPPER. (OR APPROVED EQUAL PER LOCAL WATER COMPANY). 8. THE INCOMING WATER SERVICE SHALL BE INSTALLED WITH A MINIMUM OF SIT OF COVER. 9. ALL UTILITY SERVICE LINES SHALL BE CONSTRUCTED IN ACCORDANCE WITH ALL THE LATEST APPLICABLE CODES AND TO EACH UTILITY'S AND/OR CITYS STANDARDS. 10. USE COMPACTED GRANULAR FILL WHEN UTILITY LINES ARE PLACED UNDER WALKS AND DRIVEWAYS. 11. SOIL BORINGS HAVE NOT BEEN PERFORMED AT THIS TIME. PAVEMENT DESIGN 15 BASED ON AN ASSUMED SOIL BEARING PRESSURE OF 1500 P.S.I. 12. PROVIDE SLEEVES FOR MECHANICAL WORK AS REQUIRED. 13. NOTIFY ENGINEER AT LEAST 1 DAY (24 HOURS) PRIOR TO PLACING ANY CONCRETE. 14. AREAS BETWEEN CURBING, SIDEWALKS, PAVING AND BUILDING SHALL BE FILLED WITH 4" OF TOPSOIL SUITABLE FOR LANDSCAPING. 15. SEE THIS SHEET FOR EXTERIOR CONCRETE SPECIFICATIONS. 16. SEE THIS SHEET FOR SANITARY SEWER LATERAL SPECIFICATIONS AND REQUIREMENTS. 17. THIS STRUCTURE SHALL COMPLY WITH A.DA 2010. 18. ALL EDGE OF PAVEMENT RADII ARE 5 FEET UNLESS OTHERWISE NOTED. 19. IF ACTIVE UTILITIES ARE ENCOUNTERED BUT NOT SHOWN ON THE DRAWINGS, THE ENGINEER SHALL BE ADVISED BEFORE WORK IS CONTINUED. 20. INACTIVE AND ABANDONED UTILITIES ENCOUNTERED IN EXCAVATING AND GRADING OPERATIONS SHALL BE REPORTED TO THE ENGINEER. THEY SHALL BE REMOVED, PLUGGED OR CAPPED AS DIRECTED BY THE UTILITY COMPANY AND THE ENGINEER. 21, CONTRACTOR TO INSTALL KNOX-BOX AT A LOCATION ADJACENT TO MECH/SPRINKLER ROOM. COORDINATE LOCATION, TYPE AND STYLE WITH CARMEL FIRE DEPARTMENT. UNION SIATE BANK DEED BOOK 237, PAGE 175 ACCEPTABLE TO ENGINEER. USED EVENLY MIXED SIZES OF AGGREGATE UP TO 1h MINIMUM SIZE. 8. WATER: DRINKABLE 9. AIR -ENTRAINING ADMIXTURE: ASTM C 260. 10. WATER -REDUCING ADMIXTURE: ASTM C 494; TYPE AS REQUIRED i0 SUIT PROJECT CONDITIONS. ONLY USE ADMIXTURES WHICH HAVE BEEN TESTED AND ACCEPTED IN MIX DESIGNS. 11. PROVIDE FORM MATERIALS WITH SUFFICIENT STABILITY TO WITHSTAND PRESSURE OF PLACED CONCRETE WITHOUT BOW OR DEFLECTION. 12. DEFORMED REINFORCING BARS: ASTM A 615. GRADE 60. UNLESS OTHERWISE INDICATED. 13. WELDED WIRE FABRIC: ASTM A 185. 14. JOB SITE MIXING: USE DRUM TYPE BATCH MACHINE MIXER, MIXING NOT LESS THAN 1-1/2 MINUTES FOR ONE CU. YD. OR SMALL CAPACITY. INCREASE MIXING TIME AT LEAST 15 SECONDS FOR EACH ADDITION CU. TO. OR FRACTION THEREOF. 15. READY MIX CONCRETE: ASTM C 94 16. CONSTRUCT FORM WORK SO THAT CONCRETE MEMBERS AND STRUCTURES ARE OF CORRECT SIZE, SHAPE,ALIGNMENT,ELEVATION AND POSITION. I]. CLEAN AND ADJUST FORMS PRIOR TO CONCRETE PLACEMENT. APPLY FORM RELEASE AGENTS OR WET FORMS AS REQUIRED. REiIGHTEN FORMS DURING CONCRETE PLACEMENT IF REQUIRED i0 E IMINATE EAKS L L ORIGINALTOWNOF BETHLEHAM HOLEY 44OLEY SAYS 18. SATISFACTORY SOIL MATERIAL SHALL BE FREE OF CLAY, ROCK OR GRAVEL LARGER THAN 2" IN NOW CARMEL ANY DIMENSION, DEBRIS, WASTE, FROZEN MATERIAL VEGETABLE AND OTHER DELETERIOUS ORGANIC LOT "DIG SAFELY" MATTER. SOIL SHALL CONSIST OF NONORGANIC, LOW PLASTIC (P1 20) MATERIAL. 19. SUB -BASE MATERIAL: SHALL BE NATURALLY OR ARTIFICIALLY GRADE MIXTURE OF NATURAL OR CRUSHED GRAVEL, CRUSHED STONE, CRUSHED SLAG, NATURAL OR CRUSHED SAND. 20. BARRICADE OPEN EXCAVATIONS OCCURRING AS PART OF THIS WORK AND POST WITH WARNING Q- LIGHTS. 21. PROTECT STRUCTURES, UTILITIES, SIDEWALKS, PAVEMENTS AND OTHER FACILITIES FROM DAMAGE CAUSED BY SETTLEMENT, LATERAL MOVEMENT, UNDERMINING, WASHOUT AND OTHER HAZARDS CREATED BY EARTHWORK OPERATIONS. 22. FORM CONCRETE SUCH THAT FAVORABLE DRAINAGE OCCURS i0 STORM DRAINS, STAIRWELL I DRAINS, AND/OR PARKING LOTS. NO DRAINAGE SHOULD OCCUR TOWARDS THE FOUNDATION OF I BUILDING WALLS. 23. MINIMUM CONCRETE COVER SHALL BE 3" FOR REINFORCING STEEL IN ACCORDANCE WITH (ACI 318-83). UNION STATE BANK 24. CENTER ALL FOOTINGS ON WALL PIER OF COLUMN ABOVE UNLESS OTHERWISE NOTED. DEED BOOK 335, PAGE 154 "IT'S THE LAW" 25. REINFORCEMENT IN GRADE BEAMS SHALL BE CONTINUOUS. HORIZONTAL OVERLAP SPLICES SHALL Cul BEFORE YOU GAG BE A MINIMUM OF 24". 811 26. PROVIDE CORNER BARS AT ALL CONCRETE GRADE BEAM CORNERS TO BE OVERLAPPED WITH THE I KNOW AWI acmW OUTSIDE FACE HORIZONTAL BARS. CORNER BARS ARE TO MATCH THE OUTSIDE FACE PER wOIANA STATE LAW ¢8-1-0& HORIZONTAL BARS IN SIZE, GRADE, AND SPACING. ORIGINAL TOWN OF BETHLEHAM R IS AGAINST THE LAW TO EXCAVATE 27. PIER REINFORCEMENT SHALL BE DOWELED TO THE FOOTINGS. PROVIDE DOWELS EQUAL IN SIZE. WITHOUT Romvnc TWO 2) WORKING 0 NOW CARMEL LOCATION !WO WORKING DAYS LOCATION NUMBER AND GRADE TO THE PIER REINFORCEMENT. DOWELS SHALL BE OVER -LAPPED WITH THE CSTANCEOMMENCING LOT 2 R anc WORK. PIER FOOTING DOWELS AND HAVE A FULL COMPRESSION LAP SPLICE WITH THE WALL STEEL. Cut 1-ea CALL ZLO0- io scrroe°k 28. WELDING, INCLUDING TACK WELDING, OF STEEL IS PROHIBITED. WELDING OF ° WWI rPRaa ONLY BY REINFORCING STEEL WILL BE PERMITTED ONLY BY WRITTEN APPROVAL OF THE ENGINEER, 29. SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF ANCHOR BOLTS, CHAMFERS, AND OTHER DETAILS NOT SHOWN ON THE STRUCTURAL DRAWINGS. 30. FOOTINGS SHALL BEAR ON UNDISTURBED MATERIAL. ANY UNSUITABLE MATERIAL SHALL BE REMOVED. ALL FOOTING EXCAVATIONS SHALL INSPECTED INDEPENDENT SOILS - - - - - - - ENGINEER AT DIRECTION OF GENERAL CONTRACTOR BEFORE CONCRETE IS PLACED. 31. SOILS EXPOSED IN THE BASES OF ALL SATISFACTORY FOUNDATION EXCAVATIONS SHALL BE AGAINST ANY CHANGE IN CONDITIONS SUCH AS DISTURBANCE, RAIN OR FREEZING. OFF SHALL FREEZING. SURFACE RUNOFF SHALL NOT BE ALLOWED i0 ENTER THE EXCAVATION. - _ 32. PROVIDE CONSTRUCTION, ISOLATION AND CONTROL JOINTS AS INDICATED ON CIVIL OR STRUCTURAL SHEETS. 33. ALL EXTERIOR CONCRETE SHALL BE FINISHED WITH A LIGHT BROOM FINISH FOR FLOOR SLABS WHICH SHALL HAVE A STEEL TROWEL FINISH PER NOTESESAND DETAILSS ON ON STRUCTURAL OR ARCHITECTURAL SHEETS. I 34. THE CONTRACTOR SHALL PROVIDE SPECIFICATIONS AND MANUFACTURERS DATA FOR CONCRETE SEALER, JOINT FILLER, AND CURING COMPOUND FOR ALL FLOOR SLABS, TO THE ENGINEER PRIOR ASPHALT PAVEMENT SPECIFICATIONS TO INSTALLATION FOR APPROVAL. 35. ALL SOFT, YIELDING OR OTHER UNSUITABLE MATERIALS ENCOUNTERED DURING ANY PHASE OF THE PAVING CONTRACTOR SHALL BE RESPONSIBLE FOR THE FOLLOWING: SUBGRADE CONSTRUCTION SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL. THE REPLACEMENT MATERIAL SHALL FILL THE UNSTABLE AREA FOR THE ENTIRE DEPTH OF THE 1. THE AREA TO BE PAVED SHALL BE CLEARED OF ALL ROCK, DEBRIS, ROOTS AND VEGETATION. COMPACTED SUBGRADE AND MEET THE SUBGRADE COMPACTIONS REQUIREMENTS. THE SUBGRADE AN APPROVED SOIL STERILANT SHALL BE UTILIZED TO PREVENT THE GROWTH OF WEEDS. SHALL BE SHAPED TO THE TRUE LINES AND GRADE AS SHOWN ON THE PLANS. 36. THE SUBGRADE SHALL BE COMPACTED TO 95% LABORATORY DENSITY AS DETERMINED BY AASHTO 2. ALL SOFT, YIELDING OR OTHER UNSUITABLE MATERIALS ENCOUNTERED DURING ANY PHASE OF METHOD T-99. SUBGRADE CONSTRUCTION SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL. THE 37, THE SUBGRADE AND FINISH PAVING SHALL BE TESTED BY AN APPROVED TESTING COMPANY AT REPLACEMENT MATERIAL SHALL FILL THE UNSTABLE AREA FOR THE ENTIRE.OF THE THE DIRECTION OF THE GENERAL CONTRACTOR FOR UNIFORM SMOOTHNESS DENSITY AND GRADE. T COMPACTED SUBGRADE AND MEET THE SUBGRADE COMPACTION REQUIREMENTS. THE SUBGRADE SHALL BE SHAPED TO THE TRUE LINES AND GRADE AS SHOWN ON THE PLANE. SANITARY SEWER LATERAL NOTES 3. THE SUBGRADE SHALL BE COMPACTED TO 95% LABORATORY DENSITY AS DETERMINED BY ASSRTO 1. SANITARY SEWER LATERAL CONSTRUCTION SHALL CONFORM TO CLAY TOWNSHIP REGIONAL METHOD T-99. WASTE'S(CTRW) WASTEWATER SEWER SPECIFICATIONS AND SHALL PREVAIL AS TO MATERIALS AND METHODS OF CONSTRUCTION. 4. THE SUBGRADE AND FINISH PAVING SHALL BE TESTED BY AN APPROVED TESTING COMPANY FOR UNIFORM SMOOTHNESS, DENSITY AND GRADE. 2. SANITARY SEWER LATERALS SHOWN WERE DESIGNED WITH PVC PIPE IN ACCORDANCE WITH (SDR 26) AND SLOPE A MINIMUM OF I FEET/100 FEET. 5. SLOPE PAVEMENT 0.75% (MIN.) TO INSURE PROPER SURFACE DRAINAGE. 3. ALL PVC JOINTS SHALL BE PREMOLDED, MANUFACTURED AND INSTALLED IN ACCORDANCE WITH 6. THE HOT MIX ASPHALT BASED MAY BE PLACED DIRECTLY ON THE PREPARED SUBGRADE IN ONE ASTM C-425-6 OT. LIFT FOR THE BASE COURSE TO THE REQUIRED COMPACTED THICKNESS AS SPECIFIED IN LOCAL STREET STANDARDS. 4. WHERE WATER LINES AND SANITARY SEWER LINES RUN PARALLEL WITH ONE ANOTHER, A MINIMUM OF 10 FEET HORIZONTAL SEPARATION SHALL BE MAINTAINED. 7. THE HOT MIX ASPHALT BASE AND SURFACE SHALL BE PLACED IN ONE LIFT TO THE TRUE LINE AND GRADES AS SHOWN ON THE PLANS. THE PAVING MIXTURE SHALL BE PLACED AND 5. NO ROOF DRAINS, FOOTING DRAINS AND/OR SURFACE DRAINS MAY BE CONNECTED i0 THE COMPACTED AT A TEMPERATURE BETWEEN 250 F. (121 C) AND 300 F. (149 C). SANITARY SEWER SYSTEM INCLUDING TEMPORARY CONNECTIONS DURING CONSTRUCTION. B. THE PAVING MIXTURE SHALL BE TRANSPORTED TO THE JOB SITE IN CLEAN WELL -COVERED 6. BUILDING SHALL BE SERVICED BY A 6" MINIMUM SANITARY SEWER LATERAL. THE ENDS SHALL TRUCKS WITH SMOOTH DUMP BEDS. THE BASE AND SURFACE MIXTURES ARE i0 BE PLACED WITH BE PLUGGED AND SEALED WITH WATER TIGHT PLASTIC DISC. WYES ARE TO BE TILTED UP 45 SELF CONTAINED. POWER PROPELLED PAVERS CAPABLE OF PLACING THE MIX TO THE REQUIRED DEGREES FROM HORIZONTAL, WITH SUITABLE FITTINGS FOR ALL CHANGES IN DIRECTION. DIMENSIONS AS SHOWN ON THE PLANS. 7. CLEAN OUTS SEE DETAILS IN CTRW STANDARDS SHALL BE PROVIDED EVERY 100 LINEAL FEET 9. ASPHALT GRADE SHALL BE DETERMINED BY ITS ABILITY TO SATISFACTORY COAT THE AGGREGATE, OF LATERAL AND AT EACH BEND GREATER THAN 45 DEGREES. RESIST RUTTING AND REMAIN STIFF DURING HIGH TEMPERATURES AND SUSTAIN FREEZE/THAW CYCLES IN ADDITION TO THE CONSIDERATIONS OF ANTICIPATED WEATHER, MIXING PROCESS AND CURING RATE. IQ SEE DETAIL 2 SHEET C6 FOR PAVEMENT CROSS -SECTIONS. 11. ALL PROPOSED ASPHALT PAVEMENT AS SHOWN SHALL BE CONSTRUCTED IN COMPLIANCE WITH INDOT STANDARD SPECIFICATIONS, LATEST EDITION. 12. ALL PARKING STRIPING AND ADA AREAS SHALL BE MARKED WITH A DURABLE NONSHRINK, WHITE POINT i0 BE APPROVED BY THE ENGINEER. DAMAGE i0 THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED i0 THE SATISFACTION OF THE CITY/INDOT AT THE COMPLETION OF THE PROJECT. THE CONTRATOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED SHALL BE RELOCATED i0 WITHIN ONE FOOT OF THE RIGHT-OF-WAY LINE. jezzk PROPOSED SITE PLAN IF GRAPHIC SCALE 0 20 30 40 e0 100 ( IN FEET ) inch = 20 It Z O U O N19 � a LL ILL]K a >�� N O w p U Q Q L99 o Tag ci� AN CY - 1 Lis N F ` N AIIIIIIIIIII UGo O d 0 co � a ta) IN c ta O o o OR �00 b N -� �a �e W F �� �'� wo a v a FSH V a u OL 4 W I- Z W U o U CZ7 N IIIIIIII _J d � 0 ED EEN 07 No P CO Z MJP lY 0 ZEn vUa Q Z W O 0 4 z U 2 0 J Z W Q Wz Di IL W 012 �Z zire Q I oU DRAWN BY: TEN CHECKED BY: ALD PROJECT No. 1805-008 SHEET No. C2