HomeMy WebLinkAboutG001 Life Safety PlanRELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City
yUof CaRne�ed
�VT�V1�0R141WML
DATE: \\ 09/24/19
2 LEVEL TWO LIFE SAFETY
SCALE: 3/16" =11- 011
LEVEL ONE LIFE SAFETY
SCALE: 3/1611=11- 011
APPLICABLE CODES
CODE
DESCRIPTION
COMPRISED OF
GENERAL ADMINISTRATION
RULES
GENERAL ADMINISTRATION
RULES (GAP) (UPDATED 6.1.2014)
(AMENDED 12.12014)
6751AC 12
BUILDING CODE
(INDIANA AMENDMENTS)
2014 INDIANA BUILDING CODE 1675
IAC I3M)
EFFECTIVE DECEMBER 1, W14
2012 INTERNATIONAL
BUILDING CODE 675 IAC 13-2.6
FIRE CODE
(INDIANA AMENDMENTS)
2014 INDIANA FIRE CODE(IFC)
EFFECTIVE DECEMBER 1, XH4
2012 INTERNATIONAL FIRE CODE
6751AC 22-2S
PLUMBING CODE
(INDIANA AMENDMENTS)
2012 INDIANA PLUMBING CODE
(IPC)
EFFECTIVE DECEMBER 24,2012
2006 INTERNATIONAL PLUMBING
CODE
675IAC 16-IA
ELECTRICAL CODE
(INDIANA AMENDMENTS)
20 INDIANA ELECTRICAL CODE(IEC)
EFFECTIVE AUGUST M, 2009
2008 NFPA 70
6751AC 17-1S
MECHANICAL CODE
(INDIANA AMENDMENTS)
2014 INDIANA MECHANICAL CODE(675
IAC 18-1.6) EFFECTIVE DECEMBER I,
2014
2012 INTERNATIONAL MECHANICAL
CODE
6751AC 181
HANDICAPPED ACCESSIBILITY
CODE (INDIANA AMENDMENTS)
2008 INDIANA BUILDING CODE
CHAPTER 11-ACCESSIBILITY
6751AC 13-2.5-12 CHAPTER 11
ENERGY CODE
(INDIANA AMENDMENTS)
2010 INDIANA ENERGY CONSERVATION
CODE(IECC)
EFFECTIVE MAY T, 2010
ASHRAE STANDARD 90A, 2007
6751AC 194
ELEVATOR SAFETY CODE
2011 INDIANA ELEVATOR SAFETY CODE
(IESC)
(UPDATED 9-28-11)
6751AC 21- ANSI I ASMEA17.1, 2007
ANSI I ASME AW.1, 2003
ANSI IA10A, 2004
ASME I At 8.1, W05
BUILDING REHABILITATION
STANDARD
(INDIANA AMENDMENTS)
INDIANA BUILDING REHABILITATION
STANDARD (GAR)
(UPDATED 12.22.06)
(REPEALED JUNE 18, 2008
6751AC 12-8
SANITARY CODE
(INDIANA AMENDMENTS)
1998 AMERICAN SOCIETY OF
SANITARY ENGINEERS STANDARD
051
6751AC 16-2
CODE ANALYSIS
CONSTRUCTION TYPE
VB
OCCUPANCY CLASSIFICATION
LEVELI -B- BUSINESS (MEDICAL OFFICE)
LEVEL 2-B-BUSINESS (MEDICAL OFFICE)
PROPOSED AREAS
LEVEL BASTING -2095 S0. FT.
LEVEL I PROPOSED -1446 SQ. FT.
LEVEL TOTAL -3541 30. FT.
LEVEL 2 EXISTING - 559 S0. FT.
LEVEL 2 PROPOSED -650 SO. FT.
LEVEL 2TOT& -1209 SO. FT.
EXISTING BASEMENT (MECHANICAL) -10M SQ. FT.
ALLOWABLE AREA
91 SQ. FT. -TABLE 503
ALLOWABLE HEIGHT
(2)STORIES-TABLE 503
FIRE PROTECTION
NONSPRINKLED
OCCUPANCY
LEVEL I-3541 SO. FT. 1100 = 36
LEVEL 2-1 N19 SO. FT.I f00 = 12
EXISTS REQUIRED
LEVEL I-(1) REQUIRED PERTABLE 1015.1-(4)PROVIDED
LEVEL 2- (1) REQUIRED PER TABLE 1021.2(2) - (2) PROVIDED
COMMON PATH OF EGRESS TRAVEL
ALLOWABLE 76-TABLE 1014.3
EATACCESSTRAVELDISTANCE
ALLOWABLE 200'-TABLE 10%2
DEAD END CORRIDORS
MAXIMUM ALLOWABLE DISTANCE = 20'
STAIRS
NON -ENCLOSED PER 10N.3 EX 1
EGRESS DOOR HARDWARE REQUIREMENTS
PANIC HARDWARE NOT REQUIRED - LESS THAN 50 OCC
EGRESS DOOR SWING
NO REQUIREMENT PER 1008.1.2
NOTE: ALLTOILET ROOMS ARE EXISTING -NO NEW WORK
RESTROOM FIXTURE REQUIREMENTS -PER FLOOR
LEVEL ONE REQUIRED WATER CLOSETS OR URINALS-1125 W125=2
LEVEL TWO REQUIRED WATER CLOSETS OR URINALS-1125 12I25 =1
LEVEL ONE REQUIRED SINKS -1I40 36I40=1
LEVEL ONE REQUIRED SINKS -1I40 12I40 =1
MOP SINK-1 PROVIDED IN BASEMENT
WATER COOLER -A BOTTLED WATER COOLER IS PROVIDED
U
W
n
NO
LL
a
W
Z
0)
N
Irm
SRS ARCHITECTS INC
200 S RANGELINE RD # 226
CARMEL, INDIANA 46032
PHONE: 317-989-6248
sshaGe@mitschGesigD.com
CERTIFICATION:
RESERVED, EYLEPT FOR USES EXPRESSLY
GERMo7M IN WRRING.
REV 1:
REV 2:
SHEET NUMBER.
CODE AND LIFE
SAFETY PLAN
0001