HomeMy WebLinkAboutVINE_HEALTHARE_ADDITIONS-C2.2-SITE-UTILITIES® CONTRACTOR TO COORDINATE WITH DUKE ON INSTALLATION OF NEW POWER POLE AT SE CORNER OF ALLEY/1st STREET NW INTERSECTION FOR 17- ENO -01 (VEFERANS WAY) ® CONTRACTOR TO COORDINATE INSTALLATION OF STIR 39 WITH CITY PF CARMEL AND G.C. FOR 17-ENG-01 (VETERANS WAY PROJECT) 8 CARMEL SAN SITE. SS-12 T.O.C. 825.82' EXIST. IO' INV.=818.21' (VERIFY) NEW I O'PVC INV. OUT =818.21' TYPE "I"SAN MH PER SPEC. SEE ARCH PLANS FOR INTERIOR LAYOUT, AND BUILDING DIMENSIONS NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. ITRACTOR TO COORDINATE WITH DUKE ON FECTION OF EXISTING POWER POLE & GUY 'S ADJACENT TO NEW ADARAMP FOR NEW B CUT & INSTALLATION OF SERVICE CARMELSTORMSTR. 40 A T.O.C.= 825.82E EXIST. IS" RCP E-W INV. =816.20E (VERIFY) NEW 15"FOR S INV. OUT=816.15' TYPE CA PER INDOT SPEC. r CARMEL STORM STIR. 39 IT.O.C.= 825.88E EXIST. 42" RCP E-W INV. = 813.77' (VERIFY) NEW 12"POP S INV. IN=820.32' TYPE KA PER INDOT SPEC. PROVIDE 93'-(3)2" PVC CONDUITS TO NEW METER A. DISCONNECT. VERIFY TYPE. SIZE & LOCATION WITH UTILITY r Ex. STORM SEWER CARMELIB — — — — — — — — — - - — — — — — — — — — — ::NIB — ---4 42" 7 RCP W81 ].64' f — - - — — — — — — ——7.7PR7DXI1AA7EC4-87L.F. 1"DOMESTIC / 5' 1331 /P SERVICE TO BE WET TAPPED INTO EXISTING a -� PROPOSED WATER TAPS & VALVE. VERIFY TYPE, SIZE & LOCATION, INSTALL ALL WATER PER CARMEL DETAILS PROVIDE IRICE VERTICAL SEPARATION AT ALL WATER LINE CROSSING LOCATIONS WITH ALL SEWERS & UTILITIES CONTRACTOR TO CONFIRM THE LOCATION & DEPTH OF ALL UTILITY CROSSINGS MAIN, PROVIDE A AP VERIFY AND SIZE & OP S BOX WITHIN S'OFiAP VERIFY TYPE SIZE& ' xE LOCATION CONTRACTOR TO COORDI TE WITH DUKE ON OF NEW POWER POLE FOR SINGLE F E WITH VETERANS WAY PROJECT & OF NEW OF SERVICE TO VINE H.C. e I GAS THE 2' 2" AND CONNECTION TO o '.TIC MAIN VERIFY TYPE, -OCATION WITH UTIUTY I to I I I I I LEGEND PROPOSED DOMESTIC 1"WATER METER SERVICE WITH AN INTERIOR METER AND BACKROW RPZ (INTERIOR) VERIFY TYPE. SIZE. & LOCATION WITH CARMEL WATER. B L EYi51NG YIOLO IL1 RWY $®� STORM INLETS 1' PROPOSED CONTOUR LINE ® STORM MANHOLE 5• PROPOSED CONTOUR LINE ® SOIL BORING ��—�------ 1• EXISTING CONTOUR LINE A♦' UTILITY POLE — — 5• EXISTING CONTOUR LINE p4 WATER VALVE — GAS EXISTING GAS LINE QT PHONE MANHOLE PROPERTY LINE • UTILITY PEDESTAL _ _ ADJOINER/SECTION LINE FIRE HYDRANT O MANHOLE —'-'— RIGHT-OF-WAY LINE — CENTERLINE oCO CLEAN OUT OW WATER METER SETBACK LINE 0 LIGHT POLE EASEMENT BOLLARD E EXISTING UNDERGROUND ELECTRIC LINES ELECTRIC METER OHP EXISTING OVERHEAD UTILITY LINES OO GAS METER + EXISTING UNDERGROUND PHONE pd GAS VALVE TO EXISTING TELECOMMUNICATIONS w EXISTING WATER LINE EXISTING SIDEWALK PAVERS SANITARY SEWER LINE — — — — STORM SEWER EXISTING CONCRETE SAW CUT ••• FLOW LINE w PROPOSED WATER LINE PROPOSED ASPHALT SEE DETAIL 2/C6 PROPOSED SANITARY SEWER LINE PROPOSED BUILDING ADDITION D PROPOSED STORM SEWER PROPOSED GAS SERVICE E PROPOSED UNDERGROUND ELECTRIC CONSTRUCTION LIMITS 170 PROPOSED FIBER OPTIC RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City dCETTed �VT�Vt�ORu'AWML DATE: \ 09/24/19 NEW G.FS SERVICE TO NEW METER L I I 52 T.0 SEWER 389 LL — — — .68' 15M-8•BZ7 15' RCP N 819.00' IS' RCP W 819.00E -H STREET (plat) EX. STORM SEWER III T. NW O.C.=828.65 L. — x829 ADDITION I PLEASE MAKE APPLICATION FOR RELOCATION OF GAS SERVICE LINE BY CALLING OUR NEW SERVICE CENTER AT 1-800-990-1930. IF ADDING ADDITIONAL LOAD PLEASE GIVE THAT INFORMATION TO THEM AS WELL. EXISTING WATER SERVICE NEEDS TO BE ABANDONED Q THE WATER MAIN WITH FULL CIRCLE STAINLESS STEEL REPAIR CLAMP CONTRACTOR SHALL PROTECT THE EXISTING CITY DUAL DUCT BANK IN THE RIGHT -OF-WAY. IN THE EVENT OF CONFLICT WITH THE PROPOSED IMPROVEMENTS, RELOCATION OF THE DUAL DUCT BANK AND ALL ASSOCIATED/APPURTENANT/ANCILLARY ITEMS SHALL BE THE SOLE RESPONSIBILILTY OF THE DEVELOPER SUBJECT TO REVIEW AND APPROVAL BY THE CITY. HOLEY 44OLEY SAYS "DIG SAFELY" "IT'S THE LAW" CALL BEFORE YOU ING 811 KNOW MWATX BELOW PER MOWN STATE LAW iC6-I-06. Il IS AGAINST THE LAW TO EXCAVATE WITHOUT NOTIFYING ME UNOERGRWNO LOCATION SETmCE TWO (2) WORKING DAYS BEFORE COMMENCING WORK. C&L I-590-362-5544 to scMOUM o Wole moves? SANITARY SEWER LATERAL NOTES 1. SANITARY SEWER LATERAL CONSTRUCTION SHALL CONFORM TO CLAY TOWNSHIP REGIONAL WASTE'S(CTRW) WASTEWATER SEWER SPECIFICATIONS AND SHALL PREVAIL AS TO MATERIALS AND METHODS OF CONSTRUCTION. 2. SANITARY SEWER LATERALS SHOWN WERE DESIGNED WITH PVC PIPE IN ACCORDANCE WITH (SDR 26) AND SLOPE A MINIMUM OF I FEET/100 FEET. 3. ALL PVC JOINTS SHALL BE PREMOLDED, MANUFACTURED AND INSTALLED IN ACCORDANCE WITH ASIR C-425-6 OT. 4. WHERE WATER LINES AND SANITARY SEWER LINES RUN PARALLEL WITH ONE ANOTHER, A MINIMUM OF 10 FEET HORIZONTAL SEPARATION SHALL BE MAINTAINED. 5. NO ROOF DRAINS, FOOTING DRAINS AND/OR SURFACE DRAINS MAY BE CONNECTED TO THE SANITARY SEWER SYSTEM INCLUDING TEMPORARY CONNECTIONS DURING CONSTRUCTION. 6. BUILDING SHALL BE SERVICED BY A 6" MINIMUM SANITARY SEWER LATERAL. THE ENDS SHALL BE PLUGGED AND SEALED WITH WATER TIGHT PLASTIC DISC. WYES ARE TO BE TILTED UP 45 DEGREES FROM HORIZONTAL, WITH SUITABLE FITTINGS FOR ALL CHANGES IN DIRECTION. 7. CLEAN OUTS SEE DETAILS IN CTRW STANDARDS SHALL BE PROVIDED EVERY 100 LINEAL FEET OF LATERAL AND AT EACH BEND GREATER THAN 45 DEGREES. ARMEL ENGINEERING NOT DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY/INDOT AT THE COMPLETION OF THE PROJECT. THE CONTRATOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. NO EARTH DISTURBING ACTMTY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED SHALL BE RELOCATED TO WITHIN ONE FOOT OF THE RIGHT-OF-WAY LINE. AFN PROPOSED SITE UTILITY PLAN IF GRAPHIC SCALE 0 10 m 40 e0 IW ( IN FRET ) inch = 20 U. i P�00992 " STATE OF e DIA ZOATA z 0 e O U z Z 0 0 O 7 LOT GO _ 5: 5;LL LL Uc K E 0 O > � Z Z UJ m z w w W N z z Jo o O O U ¢ ¢ z LH z m PIPm m a o 0 0 0 0 ® _ _ 4 TH L' 0 o GY S ` N U Go All O o z o 0 H� 'ta) e F a MET e .N Q n UG W O 0 — RE W Cam= CJ O U 2 4 W I— Z W U U z O LI _ � N _J o 0 FT w ,EE N 07 NO NO GO Z p LP 0 � Z NUa LID Q Z W O 0 4 z ULJ 2 0 J Z W OC Wz 012 0 Z Z Q IL > �U DRAWN BY: TEN CHECKED BY: ALD PROJECT No. 1805-008 SHEET No. C2R2