Loading...
HomeMy WebLinkAboutS100.0D03D03 D03 D01 D02 UP 43'26'5'-1 "9'-6"8' 1 2'-6" 1 2'-6" 1 0' 7'-3"6'-3 1 /8" 3'-7"15'-7 3/8"1 7'-1 " 4'-10 1/2"2'-6"GARAGE UTILITY PROPOSED 4" CONCRETE WALK PATH W/ 4" PEA GRAVEL; BRUSHED FINISH APPROX. 220 SF HH HH II II II II JJ KK LL LL MM MM NN OO OO OO OO OO GG EXISTING 2X4 FRAMING DEMOLITION & FRAMING KEY NO DEMO IN THIS ROOM EXISTING 2X6 FRAMING WALL SECTION TO BE REMOVED NEW 2x4 FRAMING NEW 2X6 FRAMING BULK HEAD / LOWERED CEILING WINDOW SCHEDULE NUMBER FLOOR QTY TOP R/O SIZE W01 2 4 76" 85"X43" 7036 DOOR SCHEDULE NUMBER FLOOR QTY TOP R/O SIZE FIRE D01 1 1 80" 38"X83" 3068 L EX D02 1 1 80" 38"X82 1 /2" 3068 R IN D03 1 3 84" 1 1 0"X87" 9070 D04 2 1 80" 32"X82 1 /2" 2668 L IN D05 2 1 80" 34"X82 1 /2" 2868 L IN YES Ariens ResidenceGarage Addition10905 Crooked Stick LnCarmel, IN 46032Date:Revision: 4 SHEET OF 15 SIGNATURE / SEALDESIGNER: TYLER VARGO E: tylerv@customlivingusa.com C: 574.274.4155Client Initials: Date: The plans, including all text, drawings, concepts and ideas, forming a part of the plans, and the selection and arrangement thereof Copright 2018 by Custom Living, Inc., Indianapolis IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans, or their content, without the prior written permission of Custom Living. Inc is strictly prohibited.CUSTOM LIVING5335 Winthrop AveIndianapolis IN 462207/11/2019 DATE: GENERAL PROPOSED PLAN NOTES Framing contractors are responsible for all labor, for the scope of work specifed on the drawings provided by Custom Living. Owner understands that Custom Living has only provided a labor and material allowance for the scope of Rough Carpentry work specified on the drawings. Any additional work added or uncovered during this scope will be a Change Order during construction Owner understands that the Drywall Allowance is based on an estimated board count and square footage take-off. A final walk through with drywall contractor after framing and mechanical rough-ins will be necessary to finalize drywall install and finish budgets. Final drywall touchups will follow countertop installation. ** PRINTS TO SCALE IF PRINTED ON 24" X 36" ** FIRST FLOOR PLAN SCALE 3/8" = 1-0" FRAMING PLAN NOTES A. Ceiling Height: 9' - 0" B. Frame Interior & Exterior 2x4 walls as shown on prints C. Stud Spacing: 16" O.C. D. Install all load bearing framing components as shown on prints E. Pressure treated bottom plate F. Frame all door openings as shown on prints G. Ceiling Joists: 16" Engineered Trusses @ 16" O.C. (direction as shown) H. W8X67 dropped steel beam as spec'd by structural engineer I. Adjustable Steel Post, Cap. > 10,500 lbs. J. Frame pony wall with 1x6 top cap K. Louvered door to Utility Room L. Epoxy Floor Finish (Garage & Utility Room) M. (2) Ply 1 3/4" X 11 7/8" Dropped LVL as Spec'd by Structural Engineer. Finish: wrapped in 1x smart trim N. (2) 2x10 Dropped Header as spec'd by structural engineer. Finish: wrapped in 1x smart trim O. Pressure Treated 4x4 post wrapped with 1x6 smart trim INSULATION PLAN NOTES Foam and fire caulk all exposed and accessible mechanical penetrations per Municipal Building Code. Install low expansion foam or backer rod around accessible exterior windows and doors. Install (1242 SF) R-15 Kraft Faced Fiberglass Batt insulation on exterior walls Install (900 SF) R-38 ceiling insulation in ceiling cavities below second floor living space DRYWALL PLAN NOTES Install drywall on all wall framing Install drywall on stairway wall framing leading to 2nd floor Interior Walls-Level 4 Finish (Smooth) Install drywall on garage & utility room ceiling framing Drywall wrap dropped steel beams Interior Ceilings- Level 4 Finish (Smooth) 09/25/19 Adam Schriner