HomeMy WebLinkAbout19090039 Energy CertificateIECC 2009 Performance Compliance Property Organization 12094 SIG ILARY LN TSI Energy Solutions CARMEL, IN 46032 317-846-4655 Model: GROSMONT Michael Hill Community: HAMLET AT JACKSON Builder JGH019 (AS DESIGNED HOMES BY MCKENZIE. HAMLET AT JACKS DNS GRANT 1E INC. Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,451 $189 $324 $1,965 $927 $0 $2,891 Requirements C-M, Energy Solutions As Designed $1,368 $166 $324 $1,859 $927 $0 $2,785 C4405.3 Performance -based compliance passes by 5.4% R402.4.12 Air Leakage Testing Air sealing is 5.50 ACH at 5D Pa. It must not exceed 7-OD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGG 402.5 Area -weighted average fenestration U-Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 5.4%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Michael Hill Organization: TSI Energy Solutions Signature: Date: 913119 at 2:08 PM Ekotrope RATER - Version 3.1.0.2243 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 12094 SIGILARY LN CARMEL, IN 46032 Builder: HOMES BY McKENZIE, INC. IIJPTO Mi Ceiling Attic, R-50 Above Grade Walls R-19 Foundation Walls NIA Framed Floor NIA Slab R-10.0 Perimeter, R-10.0 Under Infiltration 5.5ACH50 Window U-Value: 0.29, SHGC: 0.27 Building Features Duct Supply R-30.0, Return R-20.0 Duct Leakage to Outside 251 CFM25 (7.961100 s.f.) Total Duct Leakage 252 CFM25 (Post -Construction) Heating Furnace • Natural Gas • 97 AFUE Cooling Air Conditioner • Electric • 16 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name Michael Hill Organization: TSI Energy Solutions Signature: Date: 913119 at 2:08 PM Ekotrope RATER - Version 3.1.0.2243 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property 12094 SIGILARY LN CARMEL, IN 46032 Model: GROSMONT Community: HAMLET AT JACKSON JGH019 (AS DESIGNED HAMLET AT JACKSONS GRANT 1 General Building Information Conditioned Area (sq ft) Conditioned Volume (cubic ft) Insulated Shell Area (sq ft) Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder HOMES BY McKENZIE, INC. 3,154 37,064 8,522 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB (2,048 s.f., 245 ft. exterior perimeter) R-10 perimeter insulation, R-10 under slab insulation. Framed Floor None Present Foundation Wall None Present Above Grade Wall El Name: CONDIAMB (1,616 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I El Name: CONDIAMB 2X6 (2,010 s.f.) R-0 continuous insulation, R-19 cavity insulation Insulation Grade: I Name: CONDIGAR (310 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Name: CONDIGAR 2X6 (210 s.f.) R-0 continuous insulation, R-19 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property Organization 12094 SIG ILARY LN TSI Energy Solutions CARMEL, IN 46032 317-846-4655 Model: GROSMONT Michael Hill Community: HAMLET AT JACKSON Builder JGH019 (AS DESIGNED HOMES BY McKENZIE, HAMLET AT JACKS ONS GRANT 1C INC. Name: CONDIATTIC (165 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist El Name: CONDIAMB (70 s.f.) R: 11.691 L Name: CONDIATTIC (45 s.f.) R: 11.691 Roof Name: MAIN (2,048 s.f.) R-39.73 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door El Name: FRONT (43 s.f.) U: 0.182 Name: GARAGE (24 s.f.) U: 0.182 Glazing Inspection Status Results are projected E] Name: FRONT (21 s.f.), U: 0.290, SHGC: 0.27, Orientation: WEST E] Name: FRONT 2X6 (184 s.f.), U: 0.290, SHGC: 0.27, Orientation: WEST El Name: SACK (21 s.f.), U: 0.300, SHGC: 0.26, Orientation: EAST El Name: BACK 2X6 (51 s.f.), U: 0.300, SHGC: 0.26, Orientation: EAST El Name: LEFT SIDE (8 s.f.), U: 0.290, SHGC: 0.27, Orientation: NORTH C-M, Energy Solutions 2 Energy Code Inspection Checklist Property Energy Solutions Organization Inspection Status C-M 12094 SIG ILARY LN TSI Energy Solutions Results are projected CARMEL, IN 46032 317-846-4655 Model: GROSMONT Michael Hill Community: HAMLET AT JACKSON Builder JGH019 (AS DESIGNED HOMES BY McKENZIE, HAMLET AT JACKS DNS GRANT 19 INC. El Name: LEFT SIDE 2X6 (23 s.f.), U: 0.290, SHGC: 0.27, Orientation: NORTH E] Name: RIGHT SIDE (129 s.f.), U: 0.290, SHGC: 0.27, Orientation: SOUTH El !Name: RIGHT SIDE GD (24 s.f.), U: 0.290, SHGC: 0.27, Orientation: SOUTH El Name: RIGHT SIDE 2X6 (49 s.f.), U: 0.290, SHGC: 0.27, Orientation: SOUTH Skylight None Present Mechanical Ventilation None Present Mechanical Equipment 0 Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 97 AFUE M Air conditioner • Electric • 100% Cooling Load @ 16 SEER E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 3,398 CFM50 (5.50 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. 3 Energy Code Inspection Checklist Property Organization 12094 SIGILARY LN TSI Energy Solutions CARMEL, IN 46032 317-846-4655 Model: GROSMONT Michael Hill Community: HAMLET AT JACKSON JGH019 (AS DESIGNED HAMLET AT JACKSONS GRANT 1 Duct Leakage Duct System 1 Builder HOMES BY McKENZIE, INC. Inspection Status Results are projected NOT entirely within conditioned space, testing required Leakage to Outside specified as: 251 CFM25 (7.96 / 100 s.f.) Total Leakage specified as: 252 CFM25 (Post -Construction) Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage t= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property Organization Inspection Status 12094 SIGILARY LN TSI Energy Solutions Results are projected CARMEL, IN 46032 317-846-4655 Model: GROSMONT Michael Hill Community: HAMLET AT JACKSONS GRANT 19 Builder JGH019 [AS DESIGNED HOMES BY MCKENZIE, INC. HAMLET AT JACKSONS GRANT 19 [enera?Building Information Number Of Bedrooms 3 Number Of Floors 2 Conditioned Floor Area [sq_ ft.] 3;154 Unconditioned, attached garage? Yes Conditioned Volume [Cu- ft.] 37;464 Total Units in Building 1 Residence Type Single family detached Floor Number Model GROSMONT Community HAMLET AT JACKSONS GRANT 19 Climate Zone 5A Foundation Wall None Present Foundation Wall Library List None Present Slab Masonry Area C-M, Energy Solutions n SLAB R-10, 1'down, Tin 245 On Grade 1.23 0 2:048.0 R' Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective R-value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value R-10, 1'down, Tin Wood Frame /Other No 3 1 10 No 10.00 Framed Floor None Present 1 Building Summary Property Organization Inspection Status 12094 SIGILARY LN TSI Energy Solutions Results are projected CARMEL, IN 46032 317-846-4655 Model: GROSMONT Michael Hill Community: HAMLET AT JACKSONS GRANT 19 Builder JGH019 [AS DESIGNED HOMES BY McKENZIE, INC. HAMLET AT JACKSONS GRANT 19 ramed Floor Library Lis None Present Rim Joist Name Library Type Surface Area CONDIAMB G1 R-15, OSB 700 fl' CTS, Energy Solutions Locanor Exposed Exterior ICONDIATTIC G1 R-15, OSB 45.0 W Attic Rim Joist Library List Name Effective Insulation R-value G1 R-15, OSB 11.691 Name Library Type Surface Color Surface Area Location CONDIAMB G1 R-15 BATT, OSB Medium 1.616.0 ft' Exposed Exterior CONDIAMB 2X6 G1 R-19, OSB 2x6 Medium 2.010.0 f[' Exposed Exterior CONDIATTIC G1 R-15 BATT, OSB Medium 165.0 ft' Attic CONDIGAR G1 R-15 Gar Walls Medium 310.0 H' Unconditioned, attached garage CONDIGAR 2X6 G1 R-19, 2x6 GAR Medium 210.0 H' Unconditioned, attached garage 2 Building Summary Property 12094 SIGILARY LN CARMEL, IN 46032 Model: GROSMONT Community: HAMLET AT JACKSONS GRANT 19 JGH019 [AS DESIGNED HAMLET AT JACKSONS GRANT 19 Walllibrary List IN Name Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder HOMES BY MCKENZIE. INC. Inspection Status Results are projected C-M, Energy Solutions G1 R-15 BATT, OSB 13.423 G1 R-15 Gar Walls 11.972 G1 R-19, 2X6 GAR 16218 G1 R-19, OSB 2X6 17.591 Glazing Name Library Type Wall Assignment Foundation Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area Assignment Top Bottom BACK 11-.30, SHGG26 CONDIAMB ❑ 0 ❑ East 21.0 W BACK 2X6 11-.30, SHGG26 CONDIAMB 2X6 ❑ 0 ❑ East 51.0 W FRONT 11-29, SHGG27 CONDIAMB 0 0 ❑ West 21.0 ft FRONT 2X6 11-29, SHGG27 CONDIAMB 2X6 0 0 ❑ West 184.0 fts LEFT SIDE 11-29, SHGG27 CONDIAMB 0 0 ❑ North 8_0 fts LEFT SIDE 2X6 U-29, SHGG27 CONDIAMB 2X6 0 0 0 North 23.0 ft' RIGHT SIDE U-29, SHGG27 CONDIAMB 0 0 0 South 129.0 fts RIGHT SIDE 2X6 U-29, SHGG27 CONDIAMB 2X6 0 0 0 South 49.0 fF RIGHT SIDE GD 11-29, SHGG27 CONDIAMB 0 0 ❑ South 24.0 W Glazing Library List Name Singe U-factor U-29,SHGC-27 027 0290 U-.30, SHGC-26 026 0.300 9 Building Summary Property 12094 SIGILARY LN CARMEL, IN 46032 Model: GROSMONT Community: HAMLET AT JACKSONS GRANT 19 JGH019 [AS DESIGNED HAMLET AT JACKSONS GRANT 19 kyligh Skylight Library List Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder HOMES BY McKENZIE. INC. Inspection Status Results are projected C-M, Energy Solutions Opaque Door 0 Name Library Type Wall Assignment Foundation Wall Emittance Solar Surface Color Surface Area Location Assignment Ab sorpta nce FRONT Steel Door CONDIAMB 2X6 0.9 0.75 Medium 43.0 T Exposed Exterior GARAGE Steel Door CONDIGAR 2X6 0.9 0.75 Medium 24.0 f' Exposed Exterior Opaque Door Library List Name Effective U-factor 0.182 Roof Insulation Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area Location P.f.] Tiles MAIN R-50 Blown, GR1 2,D48 No Medium 2.048.0 f[s Attic Roof Insulation Library List Name Has Radiant Barrier Effective R-value R-50 Blown, GR1 No 50.474 4 Building Summary Property Organization 12094 SIGILARY LN TSI Energy Solutions CARMEL, IN 46032 317-846-4655 Model: GROSMONT Michael Hill Community: HAMLET AT JACKSONS GRANT 19 Builder JGH019 [AS DESIGNED HOMES BY McKENZIE, INC. HAMLET AT JACKSONS GRANT 19 Whole House Infiltration Infiltration 5.5 ACH at 50 Pa Mechanical Ventilation Lighting , °I Interior Fiuorescent Lighting Gnsite Generation Blower -door tested ig Y. txsenar riuorescens Lighting ❑ o None Present Gnsite Generation Library List None Present Solar Generation Solar Generation Library List Inspection Status Results are projected 4 C-M, Energy Solutions Lighting 0 Building Summary Property Organization Inspection Status 12094 SIGILARY LN TSI Energy Solutions Results are projected CARMEL, IN 46032 317-846-4655 Model: GROSMONT Michael Hill Community: HAMLET AT JACKSONS GRANT 19 Builder JGH019 [AS DESIGNED HOMES BY McKENZIE, INC. HAMLET AT JACKSONS GRANT 19 onditioning Equipment Name Library Type Pleating Percent Load Cooling Percent Load Air conditioner 116BNA048 0% 100% I Fuel -fired air 987MA6610OV21 100% 0% distribution IWater Heating RE350` 0% 0% 1 Equipment Type: 116BNA048 w==Pw Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 16 SEER Cooling Capacity [kBtulh] 46.5 Equipment Type: 987MA6610OV21 Fuel Type Natural Gas Distribution Type Forced Air Motor Type ECM (Variable Speed) Heating Efficiency 97AFUE Heating Capacity [kBtulh] 98 Use default EAE No EAE [kWh] 438 Equipment Type: RE350* Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.99 C-M, Energy Solutions r Percent Load Location 0% Conditioned Space ❑ I Conditioned Space 100% Conditioned Space 61 Building Summary Property 12094 SIGILARY LN CARMEL, IN 46032 Model: GROSMONT Community: HAMLET AT JACKSONS GRANT 19 JGH019 [AS DESIGNED HAMLET AT JACKSONS GRANT 19 1butivn System Lion Type Equipment Equipment t Served i Grilles Xct R Value ]uct R Value Xct Area r] ]uct Area [ft2] 5 to Outdoors akage akage Duct Test Conditions fault Flow Rate cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area rCeiling Fan Has Ceiling Fan Cfm Per Watt Organization TSI Energy Solutions 317-846-4655 Michael Hill Builder HOMES BY McKENZIE. INC. Forced Air Fuel -fired air distribution Air conditioner 3154 6 3❑ 2❑ 851.58 788.5 251 CFM25 (7.961 100 s.f.) 252 CFM25 Post -Construction Yes Attic (well vented; under insulation) 5 50 Conditioned Space 95 5❑ Conditioned Space 0 0 Conditioned Space Conditioned Space Conditioned Space No Inspection Status Results are projected C-M, Energy Solutions 7 Building Summary Property 12094 SIGILARY LN CARMEL, IN 46032 Model: GROSMONT Community: HAMLET AT JACKSONS GRANT 19 JGH019 [AS DESIGNED HAMLET AT JACKSONS GRANT 19 Water Distribution Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Organization Inspection Status TSI Energy Solutions Results are projected 317-846-4655 Michael Hill Builder HOMES BY McKENZIE. INC. Standard No 50 No No 140 No Electric Timer Controls ff"W 704 kWh/Year $0.081kWh $23.00 $0.581Therm 2.874 ❑.331 Yes Standard 270 kWh Electric No No 709 kWh/Year "M � C-M, Energy Solutions ,�