HomeMy WebLinkAboutHAMLET AT JACKSONS GRANT 4 - JGH04 (AS DESIGNED)IECC 2009 Performance Compliance Property 490 SIMON DR CARMEL, IN 46032 Model: CROXDALE Community: HAMLET AT JACKSON JGH04 (AS DESIGNED) HAMLET AT JACKS DNS GRANT 4 Organization TSI Energy Solutions Devin Sielschott Builder HOMES BY MCKENZIE, INC. Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance S1,587 S213 S280 $2,179 S843 SO $3,022 Requirements C-M, Energy Solutions As Designed S1,516 S172 S280 $1,968 S843 SO $2,811 C4405.3 Performance -based compliance passes by 9.7% R402.4.12 Air Leakage Testing Air sealing is 5.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGG 402.5 Area -weighted average fenestration U-Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 9.7%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 8115/19 at 9:31 AM Ekotrope RATER - Version 3.1.0.2234 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 490 SIMON DR CAR M E L, IN 46032 Builder: HOMES BY McKENZIE, INC. 17,15-PP Ceiling Attic, R-50 Above Grade Walls R-19 Foundation Walls NIA Framed Floor NIA Slab R-10.0 Perimeter, R-10.0 Under Infiltration 5 ACH50 Window U-Value: 0.29, SHGC: 0.27 Building Features Duct Supply R-10.0, Return R-10.0 Duct Leakage to Outside 156 CFM25 (5.481100 s.f.) Total Duct Leakage 208 CFM25 (Post -Construction) Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Dlevin Sielschott Organization: TSI Energy Solutions Signature: Date: 8/15119 at 9:31 AM Ekotrope RATER - Version 3.1.0.2234 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 490 SIMON DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CROXDALE Community: HAMLET AT JACKSON Builder HOMES BY McKENZIE, JGH04 (AS DESIGNED) INC. HAMLET AT JACKSONS GRANT 4 General Building Information Conditioned Area (sq ft) 2,846 Conditioned Volume (cubic ft) 31,964 Insulated Shell Area (sq ft) 8,291 inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB(1,890 s.f., 240 ft. exterior perimeter) R-10 perimeter insulation, R-10 under slab insulation. Framed Floor None Present Foundation Wall None Present Above Grade Wall El Name: CONDIAMB (1,833 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I El Name: CONDIAMB 2X6 (2,008 s.f.) R-0 continuous insulation, R-19 cavity insulation Insulation Grade: I Name: CONDIGAR (430 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CONUATTIC (99 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property 496 SIMON DR CARMEL, IN 46032 Model: CROXDALE Community: HAMLET AT JACKSON JGH94 (AS DESIGNED) HAMLET AT JACKSONS GRANT 4 Rim Joist El Name: CONDIAMB (68 s.f.) R: 11.691 Name: CONDIATTIC (73 s.f.) R: 11.691 Roof Organization TSI Energy Solutions Devin Sielschott Builder HOMES BY McKENZIE, INC. El Name: MAIN (1,890 s.f.) R-39.73 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: GARAGE (24 s.f.) U: 0.182 Glazing Inspection Status Results are projected E] Name: FRONT 2X6 (160 s.f.), U: 0.290, SHGC: 0.27, Orientation: NORTH El Name: FRONT 2X6 GD (24 s.f.), U: 6.296, SHGC: 6.27, Orientation: NORTH El Name: BACK 2X6 (43 s.f.), U: 6.366, SHGC: 6.26, Orientation: SOUTH El Name: BACK2X4 (11 s.f.), U: a.366, SHGC: 6.26, Orientation: SOUTH El Name: LEFT SIDE 2X6 (45 s.f.), U: 6.299, SHGC: 6.27, Orientation: EAST 11 Name: LEFT SIDE (180 s.f.), U: a.29a, SHGC: a.27, Orientation: EAST 11 Name: RIGHT SIDE 2X6 (25 s.f.), U: 9.299, SHGC: 9.27, Orientation: WEST E] Name: RIGHT SIDE (14 s.f.), U: a.299, SHGC: 9.27, Orientation: WEST C", Energy Solutions 2 Energy Code Inspection Checklist Property Organization 490 SIMON DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CROXDALE Community: HAMLET AT JACKSON Builder HOMES BY McKENZIE, JGH04 (AS DESIGNED) INC. HAMLET AT JACKSONS GRANT 4 Skylight None Present Mechanical Ventilation None Present Mechanical Equipment Inspection Status Results are projected 0 Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 92.1 AFUE M Air conditioner • Electric • 100% Cooling Load @ 13 SEER E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 2,664 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Leakage to Outside specified as: 156 CFM25 (5.48 J 100 s.f.) Total Leakage specified as: 208 CFM25 (Post -Construction) C", Energy Solutions 3 Energy Code Inspection Checklist Property Organization 490 SIMON DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CROXDALE Community: HAMLET AT JACKSON Builder HOMES BY McKENZIE, JGH04 (AS DESIGNED) INC. HAMLET AT JACKSONS GRANT 4 Duct Leakage Code Requirements for IECC 2009 IECC: Inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 4 Building Summary Property 490 SIMON DR CARMEL, IN 46032 Model: CROXDALE Community: HAMLET AT JACKSONS GRANT 4 JGH04 [AS DESIGNED] HAMLET AT JACKSONS GRANT 4 [enera?Building Information Number Of Bedrooms Number Of Floors Conditioned Floor Area [sq_ ft.] Unconditioned, attached garage? Conditioned Volume [cu. ft.] Total Units in Building Residence Type Floor Number Model Community Climate Zone Foundation Wall Foundation Wall Library List Slab Organization Inspection Status TSI Energy Solutions Results are projected Devin Sielschoft Builder HOMES BY MCKENZIE, JNC. 2 3 2;846 Yes 31;964 1 Single family detached CROXDALE HAMLET AT JACKSONS GRANT 4 5A None Present None Present Masonry Area C-M, Energy Solutions n SLAB R-10, 1'down, Tin 240 On Grade 1.23 0 1:890.0 R' Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective R-value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value R-10, 1'down, Tin Wood Frame /Other No 3 1 10 No 10.00 Framed Floor None Present 1 Building Summary Property Organization Inspection Status 490 SIMON DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschoft Model: CROXDALE Community: HAMLET AT JACKSONS GRANT 4 Builder HOMES BY MCKENZIE, JNC. JGH04 [AS DESIGNED] HAMLET AT JACKSONS GRANT 4 ramed Floor Library List None Present Rim Joist Name Library Type Surface Area CONDIAMB G1 R-15, OSB 68.0 fl' CV91 Energy Solutions Locanor Exposed Exterior ICONDIATTIC G1 R-15, OSB 73.0 fF Attic Rim Joist Library List Name Effective Insulation R-value G1 R-15, OSB 11.691 Name Library Type Surface Color Surface Area Location CONDIAMB G1 R-15 BATT, OSB Medium 1.833.0 ft' Exposed Exterior CONDIAMB 2X6 G1 R-19, OSB 2x6 Medium 2,008.0 ft' Exposed Exterior CONDIATTIC G1 R-15 BATT, OSB Medium 99.0 ft' Attic CONDIGAR G1 R-13 Gar Walls Medium 430.0 ft' Unconditioned, attached garage ■ Wall Library List Name Effective R-value G1 R-13 Gar Walls 11.141 G1 R-15 BATT, OSB 13.423 G1 R-19, OSB 2x6 17.591 2 Building Summary Property Organization Inspection Status Energy C-M Solutions 490 SIMON DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model: CROXDALE Community: HAMLET AT JACKSONS GRANT 4 Builder HOMES BY MCKENZIE, JNC. JGH04 [AS DESIGNED] HAMLET AT JACKSONS GRANT 4 rGlazing Name Library Type Wall Assignment Foundation Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area Assignment Top Bottom BACK 2X4 11-.30, SHGG26 CONDIAMB 0 0 ❑ South 11.0 fts BACK 2X6 11-.30, SHGG26 CONDIAMB 2X6 ❑ 0 ❑ South 43.0 fF FRONT 2X6 11-29, SHGC-27 CONDIAMB 2X6 0 0 ❑ North 160.0 fts FRONT 2X6 GD 11-29, SHGG27 CONDIAMB 2X6 0 0 ❑ North 24.0 fF LEFT SIDE U-29, SHGC-27 CONDIAMB 0 0 0 East 180.0 fts LEFT SIDE 2X6 U-29, SHGG27 CONDIAMB 2X6 0 0 ❑ East 45.0 fF RIGHT SIDE U-29, SHGG27 CONDIAMB 0 0 ❑ West 14.0 fF RIGHT SIDE 2X6 11-29, SHGG27 CONDIAMB 2X6 0 0 ❑ West 25.0 tF Glazing Library List Name Shg c U -factor U-29,SHGC-27 027 0290 U-.30, SHGC-26 026 0.300 Skylight Skylight Library List 3 Building Summary Property Organization 490 SIMON DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CROXDALE Community: HAMLET AT JACKSONS GRANT 4 Builder HOMES BY MCKENZIE, JNC. JGH04 [AS DESIGNED] HAMLET AT JACKSONS GRANT 4 ropaque Dove Name Library Type Wall Assignment FoundatPon Wall Assignment GARAGE Steel Door CONDIGAR Opaque Door Library List JA Name Effective LI-factor Steel Door 0.182 Roof Insulation Name Library Typ C-M Energy Solutions Inspection Status Results are projected Solar Surface Color Surface Area Location Absorptance 0.9 0.75 Medium 24.0 fr Exposed Exterior krea Clay or Concrete Roof �-C] Tiles 1,890 No Roof Insulation Library List -9W Name Has Radiant Barrier R-50 Blown, GR1 NC Whole House Infiltration Infiltration Measurement Type 5 ACH at 50 Pa Blower -door tested Mechanical Ventilation Effective R-value 50.474 Shelter Class n Medium 1,890.0 f[s Attic 4 Building Summary Property Organization 490 SIMON DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CROXDALE Community: HAMLET AT JACKSONS GRANT 4 Builder HOMES BY MCKENZIE, JNC. JGH04 [AS DESIGNED] HAMLET AT JACKSONS GRANT 4 ighting % Interior Fluorescent °% Interior LED Lighting % Exterior Fluorescent Lighting Lighting 0 0 C-M Energy Solutions Inspection Status Results are projected Fluorescent Lighting 0 C Gnsite Generation mmmft� m None Present Gnsite Generation Library List None Present Solar Generation I None Present Solar Generation Library List None Present Conditioning Equipment I Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load Location Airconditioner CA13NA060 0% 100% ❑% Conditioned Space Fuel4red air 912SA6010OS17 100% 0% ❑ % Conditioned Space distribution Water Heating ENT 50 100 0% 0% 100 % Conditioned Space A Building Summary Property 490 SIMON DR CARMEL, IN 46032 Model: CROXDALE Community: HAMLET AT JACKSONS GRANT 4 JGH04 [AS DESIGNED] HAMLET AT JACKSONS GRANT 4 quipment Type: Fuel Type Distribution Type Motor Type Heating Efficiency Heating Capacity [kBtulh] Use default EAE EAE [kWh] Organization TSI Energy Solutions Devin Sielschott Builder HOMES BY MCKENZIE, JNC. 912 SA60100 S 17 gquipment Type: CA13NA060 Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] Equipment Type: ENT 50 100 Natural Gas Forced Air PSG (Single Speed) 92.1 AFUE 971 Yes 1.149.1 w Electric Forced Air PSG (Single Speed) 13 SEER 58.2 Inspection Status Results are projected Fuel Type Electric Distribution Type Hydronic Delivery Hot Water Efficiency 0.93 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulh] 15.4 Recovery Efficiency 0.98 C-M, Energy Solutions Building Summary Property 490 SIMON DR CARMEL, IN 46032 Model: CROXDALE Community: HAMLET AT JACKSONS GRANT 4 JGH04 [AS DESIGNED] HAMLET AT JACKSONS GRANT 4 1butivn System Lion Type Equipment Equipment t Served i Grilles Xct R Value ]uct R Value Xct Area r] ]uct Area [ft2] 5 to Outdoors akage akage Duct Test Conditions fault Flow Rate cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area cation Supply Area Return Area rCeiling Fan Has Ceiling Fan Cfm Per Watt Organization TSI Energy Solutions Devin Sielschott Builder HOMES BY MCKENZIE, JNC. Forced Air Fuel -fired air distribution Air conditioner 2846 4 1❑ 1❑ 722.25 535 156 CFM25 (5.481 100 s.f.) 208 CFM25 Post -Construction Yes Attic (well vented; under insulation) 5❑ 50 Conditioned Space 5❑ 5❑ Conditioned Space 0 0 Conditioned Space Conditioned Space Conditioned Space No Inspection Status Results are projected C-M, Energy Solutions 7 Building Summary Property 490 SIMON DR CARMEL, IN 46032 Model: CROXDALE Community: HAMLET AT JACKSONS GRANT 4 JGH04 [AS DESIGNED] HAMLET AT JACKSONS GRANT 4 Water Distribution Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption Organization Inspection Status TSI Energy Solutions Results are projected Devin Sielschott Builder HOMES BY MCKENZIE, JNC. Standard No 60 No No 130 No Electric Timer Controls ff"W 704 kWh/Year $0.081kWh $23.00 $0.581Therm 2.874 ❑.33053 Yes Standard 270 kWh Electric No No 709 kWh/Year "M � C-M, Energy Solutions ,�