HomeMy WebLinkAboutHAMLET AT JACKSONS GRANT 4 - JGH04 (AS DESIGNED)IECC 2009 Performance Compliance
Property
490 SIMON DR
CARMEL, IN 46032
Model: CROXDALE
Community: HAMLET AT JACKSON
JGH04 (AS DESIGNED)
HAMLET AT JACKS DNS GRANT 4
Organization
TSI Energy Solutions
Devin Sielschott
Builder
HOMES BY MCKENZIE,
INC.
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
S1,587
S213
S280
$2,179
S843
SO
$3,022
Requirements
C-M,
Energy Solutions
As Designed
S1,516
S172
S280
$1,968
S843
SO
$2,811
C4405.3 Performance -based compliance passes by 9.7%
R402.4.12 Air Leakage Testing Air sealing is 5.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa.
C4402.5 Area -weighted average fenestration SHGG
402.5 Area -weighted average fenestration U-Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 9.7%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date:
8115/19 at 9:31 AM
Ekotrope RATER - Version 3.1.0.2234
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
490 SIMON DR
CAR M E L, IN 46032
Builder: HOMES BY McKENZIE, INC.
17,15-PP
Ceiling Attic, R-50
Above Grade Walls R-19
Foundation Walls NIA
Framed Floor NIA
Slab R-10.0 Perimeter, R-10.0
Under
Infiltration 5 ACH50
Window U-Value: 0.29, SHGC: 0.27
Building Features
Duct Supply R-10.0, Return R-10.0
Duct Leakage to Outside 156 CFM25 (5.481100 s.f.)
Total Duct Leakage 208 CFM25 (Post -Construction)
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Dlevin Sielschott
Organization: TSI Energy Solutions
Signature:
Date: 8/15119 at 9:31 AM
Ekotrope RATER - Version 3.1.0.2234
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh own on this report.
Energy Code Inspection Checklist
Property Organization
490 SIMON DR TSI Energy Solutions
CARMEL, IN 46032 Devin Sielschott
Model: CROXDALE
Community: HAMLET AT JACKSON Builder
HOMES BY McKENZIE,
JGH04 (AS DESIGNED) INC.
HAMLET AT JACKSONS GRANT 4
General Building Information
Conditioned Area (sq ft) 2,846
Conditioned Volume (cubic ft) 31,964
Insulated Shell Area (sq ft) 8,291
inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB(1,890 s.f., 240 ft. exterior perimeter)
R-10 perimeter insulation, R-10 under slab insulation.
Framed Floor
None Present
Foundation Wall
None Present
Above Grade Wall
El Name: CONDIAMB (1,833 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
El Name: CONDIAMB 2X6 (2,008 s.f.)
R-0 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Name: CONDIGAR (430 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CONUATTIC (99 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property
496 SIMON DR
CARMEL, IN 46032
Model: CROXDALE
Community: HAMLET AT JACKSON
JGH94 (AS DESIGNED)
HAMLET AT JACKSONS GRANT 4
Rim Joist
El Name: CONDIAMB (68 s.f.)
R: 11.691
Name: CONDIATTIC (73 s.f.)
R: 11.691
Roof
Organization
TSI Energy Solutions
Devin Sielschott
Builder
HOMES BY McKENZIE,
INC.
El Name: MAIN (1,890 s.f.)
R-39.73 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: GARAGE (24 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
E] Name: FRONT 2X6 (160 s.f.), U: 0.290, SHGC: 0.27, Orientation: NORTH
El Name: FRONT 2X6 GD (24 s.f.), U: 6.296, SHGC: 6.27, Orientation: NORTH
El Name: BACK 2X6 (43 s.f.), U: 6.366, SHGC: 6.26, Orientation: SOUTH
El Name: BACK2X4 (11 s.f.), U: a.366, SHGC: 6.26, Orientation: SOUTH
El Name: LEFT SIDE 2X6 (45 s.f.), U: 6.299, SHGC: 6.27, Orientation: EAST
11 Name: LEFT SIDE (180 s.f.), U: a.29a, SHGC: a.27, Orientation: EAST
11 Name: RIGHT SIDE 2X6 (25 s.f.), U: 9.299, SHGC: 9.27, Orientation: WEST
E] Name: RIGHT SIDE (14 s.f.), U: a.299, SHGC: 9.27, Orientation: WEST
C",
Energy Solutions
2
Energy Code Inspection Checklist
Property Organization
490 SIMON DR TSI Energy Solutions
CARMEL, IN 46032 Devin Sielschott
Model: CROXDALE
Community: HAMLET AT JACKSON Builder
HOMES BY McKENZIE,
JGH04 (AS DESIGNED) INC.
HAMLET AT JACKSONS GRANT 4
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
Inspection Status
Results are projected
0 Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 92.1 AFUE
M Air conditioner • Electric • 100% Cooling Load @ 13 SEER
E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 2,664 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Leakage to Outside specified as: 156 CFM25 (5.48 J 100 s.f.)
Total Leakage specified as: 208 CFM25 (Post -Construction)
C",
Energy Solutions
3
Energy Code Inspection Checklist
Property Organization
490 SIMON DR TSI Energy Solutions
CARMEL, IN 46032 Devin Sielschott
Model: CROXDALE
Community: HAMLET AT JACKSON Builder
HOMES BY McKENZIE,
JGH04 (AS DESIGNED) INC.
HAMLET AT JACKSONS GRANT 4
Duct Leakage Code Requirements for IECC
2009 IECC:
Inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
4
Building Summary
Property
490 SIMON DR
CARMEL, IN 46032
Model: CROXDALE
Community: HAMLET AT JACKSONS GRANT 4
JGH04 [AS DESIGNED]
HAMLET AT JACKSONS GRANT 4
[enera?Building Information
Number Of Bedrooms
Number Of Floors
Conditioned Floor Area [sq_ ft.]
Unconditioned, attached garage?
Conditioned Volume [cu. ft.]
Total Units in Building
Residence Type
Floor Number
Model
Community
Climate Zone
Foundation Wall
Foundation Wall Library List
Slab
Organization Inspection Status
TSI Energy Solutions Results are projected
Devin Sielschoft
Builder
HOMES BY MCKENZIE, JNC.
2
3
2;846
Yes
31;964
1
Single family detached
CROXDALE
HAMLET AT JACKSONS GRANT 4
5A
None Present
None Present
Masonry Area
C-M,
Energy Solutions
n
SLAB R-10, 1'down, Tin 240
On Grade 1.23
0 1:890.0 R' Exposed Exterior
Conditioned
Space
Slab Library List
Name Wall Construction Slab Completel Underslab Perimeter
Perimeter Thermal Break
Effective R-value
Type Insulated. Insulation
Width [ft] Insulation Depth [ft]
Insulation R Value
R-10, 1'down, Tin Wood Frame /Other No
3 1
10 No
10.00
Framed Floor
None Present
1
Building Summary
Property Organization Inspection Status
490 SIMON DR TSI Energy Solutions Results are projected
CARMEL, IN 46032 Devin Sielschoft
Model: CROXDALE
Community: HAMLET AT JACKSONS GRANT 4 Builder
HOMES BY MCKENZIE, JNC.
JGH04 [AS DESIGNED]
HAMLET AT JACKSONS GRANT 4
ramed Floor Library List
None Present
Rim Joist
Name Library Type Surface Area
CONDIAMB G1 R-15, OSB 68.0 fl'
CV91
Energy Solutions
Locanor
Exposed Exterior
ICONDIATTIC G1 R-15, OSB 73.0 fF Attic
Rim Joist Library List
Name Effective Insulation R-value
G1 R-15, OSB 11.691
Name
Library Type
Surface Color
Surface Area
Location
CONDIAMB
G1 R-15 BATT, OSB
Medium
1.833.0 ft'
Exposed Exterior
CONDIAMB 2X6
G1 R-19, OSB 2x6
Medium
2,008.0 ft'
Exposed Exterior
CONDIATTIC
G1 R-15 BATT, OSB
Medium
99.0 ft'
Attic
CONDIGAR
G1 R-13 Gar Walls
Medium
430.0 ft'
Unconditioned, attached garage
■
Wall Library List
Name
Effective R-value
G1 R-13 Gar Walls
11.141
G1 R-15 BATT, OSB
13.423
G1 R-19, OSB 2x6
17.591
2
Building Summary
Property Organization
Inspection Status
Energy
C-M
Solutions
490 SIMON DR TSI Energy Solutions
Results are projected
CARMEL, IN 46032 Devin Sielschott
Model: CROXDALE
Community: HAMLET AT JACKSONS GRANT 4 Builder
HOMES BY MCKENZIE, JNC.
JGH04 [AS DESIGNED]
HAMLET AT JACKSONS GRANT 4
rGlazing
Name Library Type Wall Assignment Foundation Wall Overhang Depth
Overhang Ft To
Overhang Ft To
Orientation
Surface Area
Assignment
Top
Bottom
BACK 2X4 11-.30, SHGG26 CONDIAMB
0
0
❑
South
11.0 fts
BACK 2X6 11-.30, SHGG26 CONDIAMB 2X6
❑
0
❑
South
43.0 fF
FRONT 2X6 11-29, SHGC-27 CONDIAMB 2X6
0
0
❑
North
160.0 fts
FRONT 2X6 GD 11-29, SHGG27 CONDIAMB 2X6
0
0
❑
North
24.0 fF
LEFT SIDE U-29, SHGC-27 CONDIAMB
0
0
0
East
180.0 fts
LEFT SIDE 2X6 U-29, SHGG27 CONDIAMB 2X6
0
0
❑
East
45.0 fF
RIGHT SIDE U-29, SHGG27 CONDIAMB
0
0
❑
West
14.0 fF
RIGHT SIDE 2X6 11-29, SHGG27 CONDIAMB 2X6
0
0
❑
West
25.0 tF
Glazing Library List
Name Shg c
U -factor
U-29,SHGC-27 027
0290
U-.30, SHGC-26 026
0.300
Skylight
Skylight Library List
3
Building Summary
Property Organization
490 SIMON DR TSI Energy Solutions
CARMEL, IN 46032 Devin Sielschott
Model: CROXDALE
Community: HAMLET AT JACKSONS GRANT 4 Builder
HOMES BY MCKENZIE, JNC.
JGH04 [AS DESIGNED]
HAMLET AT JACKSONS GRANT 4
ropaque Dove
Name Library Type Wall Assignment FoundatPon Wall
Assignment
GARAGE Steel Door CONDIGAR
Opaque Door Library List
JA
Name
Effective LI-factor
Steel Door
0.182
Roof Insulation
Name
Library Typ
C-M
Energy Solutions
Inspection Status
Results are projected
Solar Surface Color
Surface Area Location
Absorptance
0.9 0.75 Medium 24.0 fr Exposed Exterior
krea Clay or Concrete Roof
�-C] Tiles
1,890 No
Roof Insulation Library List -9W
Name Has Radiant Barrier
R-50 Blown, GR1 NC
Whole House Infiltration
Infiltration Measurement Type
5 ACH at 50 Pa Blower -door tested
Mechanical Ventilation
Effective R-value
50.474
Shelter Class
n
Medium 1,890.0 f[s Attic
4
Building Summary
Property
Organization
490 SIMON DR
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model: CROXDALE
Community: HAMLET AT JACKSONS GRANT 4
Builder
HOMES BY MCKENZIE, JNC.
JGH04 [AS DESIGNED]
HAMLET AT JACKSONS GRANT 4
ighting
% Interior Fluorescent °% Interior LED Lighting
% Exterior Fluorescent
Lighting
Lighting
0
0
C-M
Energy Solutions
Inspection Status
Results are projected
Fluorescent
Lighting
0 C
Gnsite Generation mmmft� m
None Present
Gnsite Generation Library List
None Present
Solar Generation I
None Present
Solar Generation Library List
None Present
Conditioning Equipment
I
Name Library Type
Heating Percent Load
Cooling Percent Load
Hot Water Percent Load
Location
Airconditioner CA13NA060
0%
100%
❑%
Conditioned Space
Fuel4red air 912SA6010OS17
100%
0%
❑ %
Conditioned Space
distribution
Water Heating ENT 50 100
0%
0%
100 %
Conditioned Space
A
Building Summary
Property
490 SIMON DR
CARMEL, IN 46032
Model: CROXDALE
Community: HAMLET AT JACKSONS GRANT 4
JGH04 [AS DESIGNED]
HAMLET AT JACKSONS GRANT 4
quipment Type:
Fuel Type
Distribution Type
Motor Type
Heating Efficiency
Heating Capacity [kBtulh]
Use default EAE
EAE [kWh]
Organization
TSI Energy Solutions
Devin Sielschott
Builder
HOMES BY MCKENZIE, JNC.
912 SA60100 S 17
gquipment Type: CA13NA060
Fuel Type
Distribution Type
Motor Type
Cooling Efficiency
Cooling Capacity [kBtulh]
Equipment Type: ENT 50 100
Natural Gas
Forced Air
PSG (Single Speed)
92.1 AFUE
971
Yes
1.149.1
w
Electric
Forced Air
PSG (Single Speed)
13 SEER
58.2
Inspection Status
Results are projected
Fuel Type
Electric
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.93 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulh]
15.4
Recovery Efficiency
0.98
C-M,
Energy Solutions
Building Summary
Property
490 SIMON DR
CARMEL, IN 46032
Model: CROXDALE
Community: HAMLET AT JACKSONS GRANT 4
JGH04 [AS DESIGNED]
HAMLET AT JACKSONS GRANT 4
1butivn System
Lion Type
Equipment
Equipment
t Served
i Grilles
Xct R Value
]uct R Value
Xct Area r]
]uct Area [ft2]
5 to Outdoors
akage
akage Duct Test Conditions
fault Flow Rate
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
cation
Supply Area
Return Area
rCeiling Fan
Has Ceiling Fan
Cfm Per Watt
Organization
TSI Energy Solutions
Devin Sielschott
Builder
HOMES BY MCKENZIE, JNC.
Forced Air
Fuel -fired air distribution
Air conditioner
2846
4
1❑
1❑
722.25
535
156 CFM25 (5.481 100 s.f.)
208 CFM25
Post -Construction
Yes
Attic (well vented; under insulation)
5❑
50
Conditioned Space
5❑
5❑
Conditioned Space
0
0
Conditioned Space
Conditioned Space
Conditioned Space
No
Inspection Status
Results are projected
C-M,
Energy Solutions
7
Building Summary
Property
490 SIMON DR
CARMEL, IN 46032
Model: CROXDALE
Community: HAMLET AT JACKSONS GRANT 4
JGH04 [AS DESIGNED]
HAMLET AT JACKSONS GRANT 4
Water Distribution
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field Utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Organization Inspection Status
TSI Energy Solutions Results are projected
Devin Sielschott
Builder
HOMES BY MCKENZIE, JNC.
Standard
No
60
No
No
130
No
Electric
Timer Controls
ff"W
704 kWh/Year
$0.081kWh
$23.00
$0.581Therm
2.874
❑.33053
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
"M �
C-M,
Energy Solutions
,�