HomeMy WebLinkAboutCeiling W A122LEGEND NEW OR RELOCATED EXISTING TO REMAIN LIGHT FIXTURE, 2'x4', METALUX LIGHT FIXTURE, 2'x4', PARABOLIC CRUZE,3500K L1LIGHT FIXTURE, 2'x2',METALUX LIGHT FIXTURE, 2'X2', PARABOLIC CRUZE, 3500K ❑ ® LIGHT FIXTURE, LED PENDANT, a LIGHT FIXTURE, 1'x4', INDIRECT A VARYING LENGTHS; REFER TO PLANS, 3500K o FOCAL POINT AVENUE B LED ee LIGHT FIXTURE, 1'x4', INDIRECT B 4LENGTH CEILING GRID FLANGE 71 RECESSED LIGHT FIXTURE, LED r( RECESSED LIGHT FIXTURE 3500K A ® LIGHT FIXTURE, PENDANT. $700 ® LIGHT FIXTURE, PENDANT MATERIAL COST/FIXTURE B ® LIGHT FIXTURE, PENDANT, $700 ® LIGHT FIXTURE, PENDANT MATERIAL COST/FIXTURE LIGHT FIXTURE, 1'x4',LED LIGHT FIXTURE, 1'x4', ® FIXTURES TO MATCH EXISTING, PARABOLIC, FIXTURES TO 3500K RECEIVE NEW LED RETROFIT KITS,3500K ® EXIT LIGHT FIXTURE ® EXIT LIGHT FIXTURE EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE $N EIGHT SWITCH, DIMMER LIGHT SWITCH $N3 LIGHT SWITCH, 3-WAY > LIGHT SWITCH, 3-WAY $NP SWITCH, PROJECTOR > SWITCH, PROJECTOR SCREEN SCREEN $NG SWITCH, GARBAGE $G SWITCH, GARBAGE DISPOSAL (ABOVE DISPOSAL COUNTERTOP( $ E SWITCH, EXHAUST FAN i — LIGHT CIRCUIT CEILING GRID, SUSPENDED, 2'x2' GYPSUM BOARD CEILING ❑ EXPOSED TO DECK RELOCATED DIFFUSER, FJ LAY -IN, 2'x2' ® RELOCATED DIFFUSER, LAY -IN, 4"x4' OR 4"XI' ®❑ EXHAUST FAN, 2'X2' GENERAL NOTES SWITCH, EXHAUST FAN LIGHT CIRCUIT I� CEILING GRID, r- SUSPENDED, 2'x2' GYPSUM BOARD CEILING ®DIFFUSER, LAY -IN, 2'x2' m DIFFUSER, LAY -IN, 4"x4' Io-1 EXHAUST FAN, 2'xZ I. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING GRID IS 2x2 AT 8'-11'A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. IF IN GOOD CONDITION, EXISTING CEILING TILES SALVAGED FROM DECONSTRUCTION CAN BE SUBSTITUTED FOR NEW. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 4. LAYOUT SHOWN IS INTENDED TO MEETASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. OVER 50% OF TH E LIGHTING WILL BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL NEED TO BE MET. 5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED. 6. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE. REPLACE WITH NEW AS REQUIRED. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTI -SWITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN, 7. ELECTRICAL WORK IS LIMITED TO DESIGN -BUILD SCOPE AND 15 OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL RELEASED FOR CONSTRUCTION PLANS CAN°BETFILED AND DES. Subject to compliance with all regulations of State and meal Codes City of Camel �VTI�tDws�D� DATE: \ 10/02/19 MECHANICAL NOTES I. MECHANICAL WORK IS LIMITED TO A DESIGN- BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENTARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENTS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE I NDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES. PLAN NOTES NOTE: NOTALL PLAN NOTES ARE USED ON EACH SHEET. ALL SCOPE OF WORK IN RESTROOMS TO BE PRICED SEPARATELY AS LANDLORD'S COST, R01 CONTROL OPEN OFFICE AREA LIGHTING WITH SWITCH AT THIS LOCATION. EACH QUADRANT TO BE ON ITS OWN SWITCH. PROVIDE MULTIPLE SWITCHES AS REQUIRED: CONFIRM FINAL LOCATIONS WITH TENANT. R02 TRANSITION FROM CEILING GRID TO EXPOSED CEILING TO BE A 5'WIDE DRYWALL BULKHEAD EXTENDING FROM 8'-10' AFF TO DECK (PAINT IN PTI FLAT FINISH(. TRANSITION TO BE A CLEAN VERICAL BULKHEAD, FINISHED SUCH THAT CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO CEILING LINE. VERTICAL FACE OF DRYWALL TO BE PAINTED COLOR OF ADJACENT WALL. R03 COORDINATE ALL DETAILS FOR BULKHEAD(INCLUDING HEIGHT) AND ANY STRUCTURAL REQUIREMENTS FOR MOVABLE WALLS WITH TENANT'S VENDOR. CONSULT WITH SDI IMMEDIATELY IF DIMENSIONS OF BULKHEAD WILL VARY FROM THOSE SHOWN ON PLANS. IF ENGINEERED STRUCTURAL PLANS ARE NEEDED, DRAWINGS BY OTHERS. R04 NO CEILING WORK AT THIS LOCATION. R05 DESIGN INTENT IS FOR LINEAR LIGHT FIXTURES TO BE TIED INTO EXISTING RESTROOM SWITCH. ORO6 CLEAN ALL EXPOSED SURFACES AND PREPARE FOR K13 ACOUSTICAL SPRAY -APPLIED PAINT AND DRYFALL PAINT (PT5) AS NOTED ON PLAN PER MANUFACTURER'S RECOMMENDATIONS. PAINT EXISTING EXPOSED CEILING DECK, EXPOSED DUCTWORK, SPRINKLER PIPING, JUNCTION BOXES, CONDUIT, STRUCTURAL BEAMS AND FIREPROOFING IN ACCORDANCE WITH NFPA 13 6.3.8. PROVIDE RIGID SPIRAL DUCT AND ROUND SUPPLY DIFFUSERS AS REQUIRED IN THIS AREA. RO] PROVIDE NEW CEILING GRID AND TILE AS SHOWN TO MATCH AND ALIGN WITH EXISTING SUCH THAT NEW AND EXISTING CEILINGS APPEAR CONTINUOUS. OPROVIDE SWITCH BANKS AT THESE LOCATIONS. INTENT IS FOR ALL LIGHTING IN ROB TOWN HALL TO BE DIMMABLE AND SEPARATED INTO (2) ZONES PER MIDDLE MOVABLE WALL. COORDINATE REQUIREMENTS WITH TENANT. OR09ENSURE LIGHTING IS 3500K CCi AND ALL FIXTURES TO BE DIMMABLE. PROVIDE ADDITIONAL CIRCUITING CAPABILITY FOR FUTURE LIGHTING; COORDINATE ALL DETAILS WITH TENANT. R10 PROVIDE APPROPRIATE CEILING WORK FOR TENANT'S CEILING PROJECTOR AND MOTORIZED, RECESSED PROJECTOR SCREEN. EAS WIN ® AREA NOT IN CONTRACT REFLECTED CEILING PLAN - WEST WING 0 2' 4' 8' 16' ❑ AREA OF WORK " — N THIS DRAWING. AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. O N Z� Oz Z 00 N LL. J Q Q z Z e Q V o =aZ Y r � LU a z z a� Z ; pp O J W Z } N z z OZ W d LU O_ O c'7 6*JII DATE I DESCRIPTION 09.06.19 IREVIEWSET 09.13.19 PERMITSET REVISIONS MAR DATE DB DESCRIPTION IN 0. AR10700017 STATE OF PROJECT NUMBER 2019.378 PROJ.MGR DRAWN BY EH AMM 4TH FLOOR WEST WING REFLECTED CEILING PLAN A122