Loading...
HomeMy WebLinkAboutDemo D112LEGEND EXISTING TO BE REMOVED EXISTING TO REMAIN ------ WALL xxxxxx PARTIAL HEIGHT WALL i DOOR AND FRAME WINDOW / SIDELIGHT a _L I I CEILING GRID AND I_____r TILES, 2'x4' 4--i--� CEILINGGRIDAND TILES, 2'X2' 6i:� SUPPLY AIR DIFFUSERS cv ea � LIGHT FIXTURE, LL___Jj' FLUORESCENT, 2'x4' raa LIGHTHXTURE, LS_J FLUORESCENT,2'x2' )2( LIGHT FIXTURE, CAN -,rr+ LIGHT FIXTURE, TRACK )E(I LIGHT FIXTURE SCONCE LIGHT FIXTURE, 05) PENDANT LIGHTSWITCH Ry EXIT LIGHT T6)TO) J ELECTRIC OUTLETS) DATA OR b COMMUNICATION OUTLET WALL xxxxx¢ PARTIAL HEIGHT WALL 77 DOOR AND FRAME x WINDOW / SIDELIGHT NOTE: EXISTING FIXTURES THATARE REMOVED CAN BE REUSED IF IN GOOD CONDITION. RECYCLING INSTRUCTIONS I. CONTACT WASTE HAULER TO ORDER TRASH DUMPSTER(S) AS REQUIRED AND III CO -MINGLE RECYCLING BIN FOR THE DEMOLITION PORTION OF PROJECT ONLY. SIZE OF CO -MINGLE CONTAINER IS DETERMINED BY THE AMOUNT OF DEMOLITION (10-40 YARD CONTAINERS AVAILABLE). 2. DRYWALL MUST BE REMOVED FROM ALL METAL STUDS PRIOR TO PLACING IN CO -MINGLE CONTAINER. ANY ADDED LABOR COST WILL BE COVERED BY METAL CREDITS RECEIVED FROM WASTE HAULER. 3. WASTE HAULER WILL APPLY CREDIT FOR METALS OBTAINED IN CO -MINGLE CONTAINER TOWARDS CONTRACTORS OVERALL INVOICE. 4. DATA/DIVERSION REPORTS ARE NOT REQUIRED NOR ANY LEED PROCESSES OR PAPERWORK, CO -MINGLE APPROVED ITEMS: 5. METALS: METAL STUDS, DOOR FRAMES, DOOR HARDWARE, CEILING GRID, LIGHT BOX FIXTURES, METAL CABINETS, METAL PLUMBING FIXTURES, ELECTRICAL AND DATA WIRING/CONDUIT, HVAC COMPONENTS, AND ELECTRICAL/DATA/SWITCH BOXES NONMETALS: SHIPPING/PACKAGING CARDBOARDS AND PLAN NOTES EAST ( WEST WING, WING I I I I I I � PLASTICS, UNTREATED WOOD STUDS AND TRIM NOTE: NOT ALL PLAN NOTES ARE USED ON EACH SHEET. ALL SCOPE OF WORK IN RESTROOMS TO BE PRICED SEPARATELY AS LANDLORD'S COST. SCHOTTXCHANGE: DO1 REMOVE EXISTING DRYWALL BULKHEAD AS SHOWN ON PLAN. 6. CONTACT SCHOTTXCHANGEBEFORE DEMOLITION OFITEMS THAT D02 REMOVE EXISTING COUNTERTOP. CANNOTBE RECYCLED OR SALVAGE FORLANDLORD, p� :) SCHOTTXCHANGE CONSIDERS: DOORS, GLASS WINDOW SYSTEMS, REMOVE EXISTING SINKS AND SALVAGE FOR REUSE. EXISTING PLUMBING TO REMAIN CABINETS, DECORATIVE LIGHTS, AND FURNITURE. IF ITEMS ARE D03 AND BE REUSED. NO SERVICE SINKS ARE BEING REMOVED. I•H ACCEPTED FOR OUR INVENTORY, COORDINATE PICKUP AFTER 1r� DEMOLITION WITH CRYSTAL BRAY (317) 762-0127 AT REMOVE EXISTING FULL LENGTH MIRROR AND ANY MIRRORS ON WING WALLS. �A SCHOTTXCHANGEAiNOCOST iOTHE PROJECT. D04 MIRROR DIRECTLY ABOVE SINK TO REMAIN. REPAIR WALL AS REQUIRED TO RECEIVE pfs" a NEW FINISHES, lyX pA,5l N fi' v N a V,,A CONTACT CRYSTAL BRAY (317) 762-0127 AT SCHOTT DESIGN FOR REMOVE EXISTING ROUNDED TRIM WALL TILE PIECE UNLESS NOTED OTHERWISE, REFER a ANY QUESTIONS REGARDING THE RECYCLING PROCESSES. DOS TO A141 FOR MORE INFORMATION. GENERAL NOTES DO6 REMOVEEXISTING PAPER TOWEL DISPENSER AND TRASH CAN UNIT REPAIR WALL AS REQUIRED TO RECEIVE NEW FINISHES. CONFIRM SALVAGE/REUSE REQUIREMENTS j WITH PROPERTY MANAGEMENT. I`�'p✓� I. REFER TO ALL DECONSTRUCTION NOTES ON TITLE SHEET TII I. REMOVE EXISTING SOLID SURFACE SHELF AND SIDE WALL REPAIR WALL AS REQUIRED ' D� D07 TO RECEIVE NEW FINISHES. 2. ALL ITEMS BEING REMOVED FROM PROJECT AREA ARE TO BE CAREFULLY CONSIDERED FOR REUSE IN THE PROJECT OR REMOVE EXISTING BULKHEAD AND IX4 LIGHT FI%TURFS ATSINK. REFER TO AI22 FOR REMOVE SALVAGED FOR LANLORD, FOR ALL ITEMS DETERMINED FOR DO6 MORE FORMATION. REMOVAL, REFER TO THE RECYCLING INSTRUCTIONS. OFL REPAIR WLL AS REQUIRED TOLLL EIVE 3. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS SHOWN D09TILE FINSHS H. DESIGN INTENT SPORION FOR PORTION OF TILE i FLOOR TO WALON TO TRANSITION ON PLAN PER LEGEND, PATCH WALL AND PREPARE FOR NEW REMAIN AND BE USED AS WALL BASE, REFER TO A141 FOR MORE INFORMATION, FINISHES AS REQUIRED. \iGYA9WIL D10 REMOVE AND SALVAGE EXISTING FAUCETS AND SOAP DISPENSERS FOR REUSE. 4. EXISTING FLOOR AND WALL TILE IN RESTROOMS TO REMAIN, UNLESS NOTED OTHERWISE. REMOVE CEILING HEATING TILE AND REPLACE WITH NEW CEILINGTILE TO MATCH Dtt BUILDING STANDARD; CONFIRM SPECIFICATION WITH PROPERTY MANAGEMENT. 5. EXISTING TOILETS, URINALS, TOILET PARTITIONS, GRAB BARS AND RESTROOM ACCESSORIES TO REMAIN UNLESS NOTED ® AREA NOT IN CONTRACT REMOVE FLOOR TILE IN THIS AREA AND PREPAREAS REQUIRED FOR NEW FINISHES. OTHERWISE. D12 O PROVIDE APPROPRIATE TRANSITION STRIP BETWEEN RESTROON ILE FLOORAND NEW RELEASED FOR CONSTRUCTION 'AND FINISH AT THIS LOCATION. ❑ AREA OF WORK LIGHTING TO REMAIN REMOVE ANY EXISTING WALLCOVERING AT THIS LOCATION IN PREPARATION FOR Subject to compliance with all regulations D13 NEW. REFER TO A141 FOR MORE INFORMATION. of State and Local Codes City of Camel DATE: 10/02/19 0 .A .A ,.A w o •� U' �) o p v ' A \ k' i:3 A A A - a ,.a 0 A a e " ` `m. ,A .A _.tA '.A 0 ,.a ..A ,.A -" ,.A A "a S'A �p :A A f 0' e a p o A .r a K' fo N N% DECONSTRUCTION PLAN - WEST WING 0 2' 4' 8' 16' ■ = MIS DRAWING, AND ME IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT ME WRITTEN CONSENT OF SCH07 DESIGN. 0 CV ZO V 00 N LL J � L Q Q Z 1 Q V�o Q Z Y r � LU Q N� Z Q pp O r Z " Z OZ W CL D_ 0 SSUE DATE I DESCRIPTION 09.06.19 REVIEW SET 09.13.19 PERMITSET REVISIONS MARK DATE I DB DESCRIPTION N0. AR10700017 STATE OF 9:103101II211144J piFjrxLrE, PROD. MGR DRAWN BY _ I EH AMM 4TH FLOOR WEST WING DECONSTRUCTION PLOW D112