HomeMy WebLinkAboutElectrical E111LEGEND NEW CONSTRUCTION EXISTING TO REMAIN =0 POWER OUTLET, DUPLEX POWER OUTLET, DUPLEX POWER OUTLET, POWER OUTLET, QUADRUPLEX QUADRUPLEX ® JUNCTION BOX QJ JUNCTION BOX OCEILING MOUNTED CEILING MOUNTED JUNCTION BOX JUNCTION BOX ® BOX, BLANK COVER PLATE ® BOX, BLANK COVER PLATE ® BOX, OPEN QO BOX, OPEN PROVIDE JUNCTION BOX P POWER AND DATA POLE ABOVE CEILING FOR O POWER POLE CONNECTION, POWER POLE BY OTHERS. FLOOR BOX WITH POWER FLOOR BOX WITH POWER WIQ AND DATA, FLUSH will AND DATA, FLUSH MOUNTED MOUNTED FLOOR BOX WITH FLOOR BOX WITH 5�I41 JUNCTION BOX AND J b JUNCTION BOX AND DATA, FLUSH MOUNTED DATA, FLUSH MOUNTED DATA/COMMUNICATION 14 OUTLET (PROVIDE BOX b DATA/COMMUNICATION AND PULL STRING ONLY) OUTLET GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET +42" HEIGHT OF ELECTRICAL OR DATA DEVICE GENERAL NOTES I. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF�� FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO INSTALLED 18" MIN. A.F.F. TO THE CENTER OF E10 THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL NEW DEVICES AND FACE PLATES TO BE WHITE, REPLACE WITH NEW E15 - AS REQUIRED. ee E20 3. REFER TO DOOR SCHEDULE AND COORDINATE WITH SVP� XX TENANT/OWNER REGARDING POWER LOCATIONS TO OF OPS ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR 4 5 E05 MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANTS SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. / 4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED \� TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES J AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. PLAN NOTES 0PROVIDE POWER AS REQUIRED FOR CARD READER (CARD READER BY TENANT). �\� E01 COORDINATE WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MOREil DETAILS. AT BUILDING STAIR LOCATIONS, INTENT 15 FOR SUITE TO BE SECURE FROM STAIR 4t SIDE. yyy/// E02 CO IDNATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS � O y E03 COORDINATE ALL POWER REQUIREMENTS AND LOCATIONS IN THIS AREA WITH TENANT. �( OPROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO CABINET/WALL FOR \; E04 TENANTS MICROWAVE, CENTERED AT 24"AND 60" A.F.F. REFER TO ELEVATIONS FOR MORE INFORMATION. E05 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN. COORDINATE EXACT LOCATION WITH TENANT AND TENANTS FURNITURE VENDOR, PROV UNT E WITH E THIRD DEVICE FOR ELECT ICAL AND E06 DATA. OCOORDINATE WITHOOANTS URNTUREEKENDOR ON EXACT LOCATION. PROVIDE POKE THRU DEVICE SUBMITTAL O TENANT FOR APPROVAL PRIOR TO ORDERING. PROVIDE PLAN NOTES CONT D 1 SEPARATE PRICE FOR POWER POLES AT WORKSTATION PODS IN LIEU OF FLOOR CORES; INCLUDE POSSIBLE CORE REUSE LOCATION AS PART OF SEPARATE PRICE (WORKSTATION POD ON WEST WING WITH E07 PLAN NOTE). COORDINATE OUTLET FOR TENANT'S UN DERCOUNTER IF POSSIBLE, PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THRU DEVICE FOR ELECTRICAL REFRIGERATOR WITH CASEWORK. E77 E07 AND DATA AT EXISTING CORE LOCATION. COORDINATE WITH TENANTS FURNITURE VENDOR E19 PROVIDE(3) DEDICATED 20 AMP CIRCUITS IN THIS ROOM. TO DETERMINE IF CORE CAN BE REUSED, PROVIDE NEW FLOOR CORE IF LOCATION DOES COORDINATE ALL REQUIREMENTS WITH TENANT AND NOT WORK WITH LAYOUT. PROVIDE POKE THRU DEVICE SUBMITTAL TO TENANT FOR TENANTS IT VENDOR. APPROVAL PRIOR TO ORDERING. E08 AT INDICATED LOCATIONS, INTEGRATED USE PORT TO BE PROVIDED. E19 VERTICAL REF PROVIDE (FACE OF ISLAND DIVIDER; OUTLETS O ELEVATIONS PROVIDE POWER AT THIS LOCATION FOR TENANT'S GARBAGE DISPOSAL, DISHWASHER, ICE AND SECTION. E09 MAKER, AND WATER DISPENSER (AS REQUIRED). IF POSSIBLE, CONVERT EXISTING BLANK/OPEN BOX TO NEW PROVIDE JUNCTION BOX AND DATA FOR TENANT'S FURNITURE SYSTEM. COORDINATE E20 RECEPTACLE AS SHOWN. IF NOT POSSIBLE, REMOVE 0 EXACT LOCATION WITH TENANT'S FURNITURE VENDOR. BLANK/OPEN BOX AND PROVIDE NEW RECEPTACLE AT THIS OCATION. E11 NO ELECTRICAL WORK IN THIS AREA. E12 PROVIDE RECESSED POP-UP POWER IN COUNTER (MOCKER 'S PCS82B/UI-POP-UP POWER GROMMET-2 POWER/I DUAL USE CHARGER, COLOR LED) OR EQUAL; CONFIRM EXACT LOCATION WITH TENANT. E13 PROVIDE DOOR RELEASE BUTTON FOR DOUBLE HERCULITE DOORS AT RECEPTION DESK. COORDINATE ALL REQUIREMENTS WITH TENANT. E14 ALL RECEPTACLES AT THIS LOCATION TO BE INSTALLED HORIZONTALLY. OPROVIDE DI RECT HDMI/VGA CONDUIT CONNECTION FROM FLOOR CORE POKE THRU E15 DEVICE (WHERE APPLICABLE) OR WALL LOCATION TO WALL MOUNTED MONITOR(S). AT EXECUTIVE OFFICES (4 CORNER OFFICES), PROVIDE HDMI/VGA CONDUIT CONNECTION FROM WALL MOUNTED MONITOR TO DESK AND TO MEETING TABLE; CONNECTION PERMITTED TO BE IN WALL. COORDINATE LOCATIONS WITH TENANT AND FINAL FURNITURE AYOI IT RELEASED FOR CONSTRUCTION NO FOR TENANT PROVIDED CEILING PROJECTOR Subject to compliance with all regulations INTO CEILING). COORDINATE WITH TENANT AND 7IUIREMENTS. of State and Local Codes City of Camel DATE: 10/02/19 ® AREA NOT IN CONTRACT ❑ AREA OF WORK L r fi VISITOR OFFICE 0 \r=91 PIION IFF=i 0 E08 ac% ® E03 L�zi p� E14 SERVER E18 �L nE3 rALzi LF STG 0 QUIET ROOM EAST [-WEST WINGI WING I I M6 DRAWING. AND ME IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR V S I `R IN PART, WITHOUT ME WRRTEN ' FF E CONSENT OF SCH07 DESIGN. a6 I o I N NO Z O z_ O AT e • —' R WA IIII �,/, � �' III CO , • • E01 T SSUE CLOSET DATE I DESCRIPTION 09.06.19 REVIEW SET 09.13.19 PERMITSET p p T 0 ­r5\ REVISIONS I \ ".LLY' MARK DATE I SIR DESCRIPTION F_EX lG Si L�'il .(CV% - 1 _ a3a „s- E09 .J�i / 4E19C/ ilJ `JIJ LJi J.>✓ I I D 7 QFC/ ?q„ O F �1\C1 H BQ/l 05 E09 O F 2. F 7q,,o No. / O C ?Qa OFD r E.t r1_1 ST)ATEO017 G OF PR�\� I 7'SOC© Ue0 � 6� 6;it E05 PROJECT NUMBER 2019.378 PROD. Mill DRAWN BY E12 \ EH AMM 4TH FLOOR EAST WING ELECTRICAL PLAN - EAST WING I ELECTRICAL PLAN 0 2' 4' 8' 16 E I I I N