Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Floor Plan E A111
ARCHITECTURAL LEGEND GENERAL NOTES NEW CONSTRUCTION EXISTING TO REMAIN ITWALL YR — WALL ® PARTIAL HEIGHT WALL ® PARTIAL HEIGHT WALL a>—u WINDOW/SIDELIGHT WINDOW/SIDELIGHT DOOR AND FRAME (SEE DOOR SCHEDULE) 77 DOOR AND FRAME NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS, WALL TYPES NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE Wl UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT/GREENS ARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALLTYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. WT WALL WITH INSULATION - 35/8" METAL STUDS AT 16" O.CJ ONE LAYER OF 6X TYPE"X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'FO EACH SIDE OF WALL ABOVE CEILING W2 DEMISING WALL TO DECK WITH INSULATION 35% METAL STUDS AT 16O.C.; ONE LAYER OF%TYPE "X"GYPSUM BOARD �, -�, EACH SIDE; EXTEND WALL TO DECK; FIBERGIAS SOUND BATT INSULATION INSIDE WALL. F3] PARTIAL HEIGHT WALL METAL STUDS AT 24" O.C.; ONE LAYER OF 5/g' TYPE "X" GYPSUM BOARD EACH SIDE; REFE R TO ELEVATIONS AND SECTION FOR HEIGHT; PROVIDE 1'STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED PLAN NOTES NOTE: NOT ALL PLAN NOTES ARE USED ON EACH SHEET. ALL SCOPE OF WORK IN RESTROOMS TO BE PRICED SEPARATELY AS LANDLORD'S COST. 8 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. A02 PROVIDE PLYWOOD PHONE BOARD, 4'xSY)J' PAINTED WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. A03 NEW FIRE EXTINGUISHER IN RECESSED CABINET TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 3. PROVIDE SEPARATE PRICE FOR MANUAL DRAPER SHADES ON EXTERIOR WINDOWS THROUGHOUT. MATERIAL AND COLOR TED. SVP OF OPS 17471 PROVIDE SEPARATE PRICE FOR ACOUSTICAL SEALANT AT ALL A04 ARCHITECTURAL JOINTS/TRANSITION POINTS FOR INCREASED ACOUSTICAL PROTECTION IN THIS ROOM. PROVIDE ADDITIONAL BLOCKING IN WALLAS REQUIRED FOR A05 TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. IN NEW EXPOSED DECK AREA, ENSURE EXISTING PROVIDE SEPARATE PRICE FOR RECEPTION DESK (SHOWN ON A14 DRYWALL EXTENDS TO DECK ALONG THIS WALL. A06 PLAN) TO BE BUILT-IN MILLWORK IN LIEU OF FURNITURE. ASSUME PROVIDE NEW IF REQUIRED. MILLWORK CONSTRUCTION, PLASTIC LAMINATE WORK SURFACE WITH BUILT-IN STORAGE (3 TOTAL 15" WIDE SECTIONS PROVIDE I8" DEEP PLASTIC LAMINATE (PL2) SHELF ATTHIS OF STORAGE) AND SOLID SURFACE TRANSACTION TOP. A15 LOCATION AT 42"AFF; DIMENSION TO BE 24"AT LONG EXPOSED DRAWINGS TO FOLLOW. END AND 30" AT LONG END MOUNTED TO WALL. MOUNT TO WALL WITH RAKKS EH-1212-FM BRACKET ATTACHED TO METAL PROVIDE (5) ADJUSTABLE 16" DEEP WHITE MELAMINE SHELVES STUDS WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER A07 ON HEAVY DUTY KV BRACKETS AND STANDARDS. VERTICAL SUPPORT. CASEWORK CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL. SEPARATE PRICE FOR 2'HX3"W SOUNDPROOF COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL OPROVIDE A08 WINDOW ATTHIS LOCATION. COORDINATE FINAL INSTALLATION AS NEEDED. SPECIFICATIONS WITH TENANT. PROVIDE 2/" TEMPERED GLASS WINDOW ATTHIS LOCATION Alb PROVIDE NEW 2'-0" DEEP PLASTIC LAMINATE (PL2) WORKSURFACE AT 42" A.F.F. AS SHOWN ON PLAN. COUNTER TO AOg WITH BUTTGLAZED PANELS. SEE DIMENSION ON PUN FOR MIMIC CURVE OF WINDOW AS SHOWN AND EXTEND FROM WIDTH, CONFIRM IN FIELD. FRAME TO MATCH SUITE STANDARD COLUMN TO COLUMN. PROVIDE MITER EDGE DETAIL AT NORTH DOOR FRAME. AND SOUTH EDGES TO CREATE WATERFALL ENDS AND PROVIDE CENTER SUPPORT PANEL (PLI) AS REQUIRED. NO BACK OR PROVIDE NEW 70" DEEP X FULL LENGTH PLASTIC LAMINATE SIDESPLASH. PROVIDE ADDITIONAL MODESTY PANEL TO DISGUISE A10 (PL2) WORKSURFACE AT 42" A.F.F. AS SHOWN ON PLAN. WIRING FROM POWER GROMMETS; REFER TO ELECTRICAL PLANS PROVIDE 2" BACKSP ASH; NO SIDESPLASH. VERIFY EXACT VERIFY EXACT DIMENSIONS IN FIELD. NOTIFY SDI IF ADDITIONAL DIMENSIONS IN FIELD. SUPPORT COUNTER AS REQUIRED WITH SUPPORT IS REQUIRED; INTENT IS FOR ANY ADDITIONAL SUPPORT APPROPRIATE MOUNTING BRACKETS PER MOUNTING ON TO BE AS CONCEALED AS POSSIBLE. BACKSIDE OF WET WALL. DESIGN INTENT IS FOR BRACKETS TO BE AS CONCEALED AS POSSIBLE. PROVIDE NEW 18" DEEP L-SHAPED PLASTIC LAMINATE (PL2) A11 ISLAND TO BE CENTERED ON SOCIAL AREA INSET. A17 WORKSURFACE AT 30" A.F.F. AS SHOWN ON PLAN. PROVIDE 2" BACKSPLASH (NO SIDESPLASH) AND (2) GROMMETS IN WORKSURFACE. VERIFY EXACT DIMENSIONS IN FIELD. SUPPORT PROVIDE SEPARATE PRICE FOR WALLS (OFFICE FRONTS) TO BE COUNTER AS REQUIRED WITH RANKS EH-1212-FM BRACKET A72 CONSTRUCTED AS SHOWN. TENANT MAY UTILIZE FURNITURE ATTACHED TO METAL STUDS WITH WOOD BLOCKING AND WALLS (BY FURNITURE VENDOR) ATTHIS LOCATION IN LIEU OF DRYWALL INSTALLED OVER VERTICAL SUPPORT. CASEWORK DRYWALL WALLS. CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL. COORDINATE APPROVAL OF SHOP PROVIDE NEW MOBILE PARTITION AS NOTED AND PROVIDE ANY DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED. Ala ADDITIONAL SUPPORT ABOVE CEILING AS REQUIRED: PARTITION TO BE HUFCOR (OR SIMILAR) SERIES 632 MANUALLY OPERATED PAIRED PANEL PARTITION. PANELS TO BE HINGED TOGETHER IN PROVIDE POTABLE HOT AND COLD WATER AND SANITARY PAIRS WITH AN STC MINIMUM OF 54. BOTTOM SEALS TO BE Pol O WASTE AND VENT PIPING FOR SINKS. MECHANICALLY OPERATED RETRACTABLE BOTTOMSEALS REFER TO LANDLORD FOR SOURCE OF HOT WATER AND (AUTOMATIC BOTTOM SEALS ARE NOT ACCEPTABLE), MULTI -PLY LOCATION ALLOWED IN THIS BUILDING. VINYL TOP SWEEPS AND LEAD PANEL TO HAVE FULL HEIGHT FINALBULB SEALS. ER MAKER, AND WATER DOOR TO HAVE ADA COMPLIANT CLOSURE JAMB. PASSS P02 DISPENSER. ER. CONFIRM LOCATION WITH <u-P111 A ITSELF MUST HAVE AN RELEASED TO THE FOR CONSTRUCTION SALVAGEPD SINKS T E REINSTALLED IN SAME LOCATION; REUSE EQOIN DETAPANELS ILED MOBILE P03 IP Subject to compliance with all regulations BY OTHERS. PROVIDE ALL PLUMBING AND DRAINS FOR TENANT'S of State and Local Codes IS DISHWASHER AND ICE MAKER AS REQUIRED. City of Camel DATE: 10/02/19 ® AREA NOT IN CONTRACT ❑ AREA OF WORK MANAGER STATIONS D7 EAST [WEST WINGI WING I I THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 D DESIGN, INC., AND ARE NOT TO BE JJ�� USED OR REPRODUCED IN WHOLE, OR ry STOR VISIIEJR IN PART, WITHOUT THE WRITTEN y, OEA01A01 OF��ICCE CONSENT OF SCHOII DESIGN. as A05 2 A05 1p'-0 p 10"0 0 os N CONFERENCF A05 -ia BOARD ROOM A05 CONFERENCE 69 OS CJ - ® ( ]0 I O V } Z O 4 I O J 65 11 J ° O � 14 HON SO` � 2 � Al2 O 03 �"\`�p Al2 A06 2 I Q 15 HOV LLe MAIL,3-" Z ¢O 16 a RN A15 A03 ENTRY WAIT A05 / 1, I 0 17 A02 SERVER Q MKTG © ■ R ■ STG W � A01 Q CL U1 Z N aaaaaaaa Z Q 18 EL®S.A01 W2 O J P01 I } MEWS I Z z L FREIGHT ELEVATOR LOBBY RR RR L Z LOBBY ® �VA LLJ W CJ O )SET A03 e ® ID A ICN of 28 CLOSET e` A03 $SUE 29 A01 W2 _ 2 A01 2 A01 I DATE DESCRIPTION y ¢ -K00 109.06.19 REVIEW SET �2 eve A14 2 I 09.13.19 PERMITSET 2 O AO] 3413 a i A01 REVISIONS 2 MAR R DES DATE DCRIPTION ��N I 2 F41 I 4 � � P02 i T PO4 A21v D 3 I ear F Aos Pot No. An I AR10700017 W2 2 a STATE OF G u2 35 SOCIAL HUB QUIET OM 17471 2 A05 PROJECT NUMBER 2019.378 A01 A16 PROJ. MGR DRAWN BY EH AMM A14 4TH FLOOR EAST WING ARCHITECTURAL ARCHITECTURAL PLAN: EAST WING 0 2' 4' 8' 16'