HomeMy WebLinkAboutFloor Plan W A112ARCHITECTURAL LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
TWALL WALL
F�� �79d:i1L\\Eli[HEI\TL\RR
II PARTIAL HEIGHT WALL
an Fa WINDOW/SIDELIGHT WINDOW/SIDELIGHT
(97 DOOR AND FRAME DOOR AND FRAME
(SEE DOOR SCHEDULE)
NOTE: IF IN GOOD CON DI➢ON, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
WALL TYPES
NOTE: l
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE H UNLESS OTHERWISE NOTED. PROVIDE MOISTURE
RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR
SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
H WALL WITH INSULATION
3% METAL STUDS AT I6"O.CJ
ONE LAYER OF % TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
0 DEMISING WALL TO DECK WITH INSULATION
3%8METAL STUDS AT 16' O.C.;
ONE LAYER OF SVB TYPE "X" GYPSUM BOARD
EACH SIDE; EXTEND WALL DECK; FIBERGLAS
SOUND BATT INSULATION INSIDE
IDE WALL.
PARTIAL HEIGHT WALL
2%" METAL STUDS AT 24" O C.;
ONE LAYER OF S54' TYPE "X" GYPSUM BOARD
EACH SIDE;
REFER TO ELEVATIONS AND SECVON FOR HEIGHT:
PROVIDE 1"STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED
PLAN NOTES
NOTE: NOT ALL PLAN NOTES ARE USED ON EACH SHEET.
ALL SCOPE OF WORK IN RESTROOMS TO BE PRICED SEPARATELY
AS LANDLORD'S COST.
A01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR THRILLS OR WHERE NEW
WALLS ARE IN LINE WITH EXISTING WALLS.
PROVIDE PLYWOOD PHONE BOARD, 4'x8'xi", PAINTED WITH FIRE
A02 RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY
LOCATION WITH TENANT PRIOR TO INSTALLATION.
ONEW FIRE EXTINGUISHER IN RECESSED CABINET TO BE PROVIDED
A03 AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE
TO BE INSTALLED ACCORDING TO NFPA 10.
A04 PROVI DE SEPARATE P RIC E FOR ACOUSTICAL S EALANT AT ALL
ARCHITECTURAL JOINTS/TRANSITION POINTS FOR INCREASED
ACOUSTICAL PROTECTION IN THIS ROOM.
PROVIDE ADDITIONAL BLOCKING IN WALLAS REQUIRED FOR
A05 TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT.
rPL:AN)E SEPARATE PRICE FOR RECEPTION DESK ]SHOWN ON
O BE BUILT-IN MILLWORK IN LIEU OF FURNITURE. ASSUME
RK CONSTRUCTION, PLASTIC LAMINATE WORK
E WITH BUILT-IN STORAGE (3 TOTAL IS"WIDE SECTIONSAGE) AND SOLID SURFACE TRANSACTION TOP.
GS TO FOLLOW.
A07 PROVIDE (5) ADJUSTABLE 16" DEEP WHITE MELAMINE SHELVES
ON HEAVY DUTY KV BRACKETS AND STANDARDS,
OPROVIDE SEPARATE PRICE FOR 2'Hx3'W SOUNDPROOF
A06 WINDOW AT THIS LOCATION. COORDINATE FINAL ,
SPECIFICATIONS WITH TENANT.
PROVIDE %" TEMPERED GLASS WINDOW AT THIS LOCATION
WITH BUIIGLAZED PANELS. SEE DIMENSION ON PLAN FOR
WIDTH, CONFIRM IN FIELD. FRAME TO MATCH SUITE STANDARD
DOORFRAME.
PROVIDE NEW 2'-0" DEEP X FULL LENGTH PLASTIC LAMINATE
)PL2) WORKSURFACE AT 42" A.F.F. AS SHOWN ON PLAN.
PROVIDE 2" BACKSPLASH; NO SIDESPLASH. VERIFY EXACT
DIMENSIONS IN FIELD. SUPPORT COUNTER AS REQUIRED WITH
APPROPRIATE MOUNTING BRACKETS PER MOUNTING ON
BACKSIDE OF WET WALL. DESIGN INTENT IS FOR BRACKETS TO
AS CONCEALED AS POSSIBLE.
ISLAND TO BE CENTERED ON SOCIAL AREA INSET
CONSTRUCTED AS SHOWN, TENANT MAY UTILIZE FURNITURE
WALLS (BY FURNITURE VENDOR) ATTHIS LOCATION IN LIEU OF
DRYWALL WALLS,
PROVIDE NEW MOBILE PARTITION AS NOTED AND PROVIDE ANY
A13 ADDITIONAL SUPPORT ABOVE CEILING AS REQUIRED: PARTITION
TO BE HUFCOR (OR SIMILAR) SERIES 632 MANUALLY OPERATED
PAIRED PANEL PARTITION. PANELS TO BE HINGED TOGETHER IN
PAIRS WITH AN STC MINIMUM OF 54. BOTTOM SEALS TO BE
MECHANICALLY OPERATED RETRACTABLE BOTTOM SEALS
(AUTOMATIC BOTTOM SEALS ARE NOT ACCEPTABLE), MULTI -PLY
VINYL TOP SWEEPS AND LEAD PANEL TO HAVE FULL HEIGHT
BULB SEALS. FINAL CLOSURE TO BE BY EXPANDABLE LEVER
RELEASED FOR CONSTRUCTION r°FCO Si HAVE AN
DITION TO THE PANEL'S
Subject to compliance with all regulations EQUIRED, DETAILED MOBILE'
of State and Local Codes BY OTHERS.
T, City of Camel
IVM1��LJtD,AC�BDa/�K
DATE: \ 10/02/19
GENERAL NOTES
I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT
OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5
DRYWALL FINISH. REFER TO MANUFACTURER
RECOMMENDATIONS.
3. PROVIDE SEPARATE PRICE FOR MANUAL DRAPER
SHADES ON EXTERIOR WINDOWS THROUGHOUT,
MATERIAL AND COLOR TBD.
WALL
TYPICAL WAI
METAL STUD
EXISTING WIN
MULLION
PRE -FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
n WALL AT MULLION DETAIL
AI 12 NO 1 10 SCALE
IN NEW EXPOSED DECK AREA, ENSURE EXISTING
DRYWALL EXTENDS TO DECK ALONG THIS WALL.
PROVIDE NEW IF REQUIRED.
PROVIDE 18" DEEP PLASTIC LAMINATE (FILE) SHELF AT THIS
LOCATION AT 42" AFF; DIMENSION TO BE 24" AT LONG EXPOSED
END AND 30"AT LONG END MOUNTED TO WALL. MOUNT TO
WALL WITH RAKKS EH-1212-FM BRACKET ATTACHED TO METAL
STUDS WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER
VERTICAL SUPPORT. CASEWORK CONTRACTOR TO INSTALL
BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL.
COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL
INSTALLATION AS NEEDED.
PROVIDE NEW 2'-0' DEEP PLASTIC LAMINATE (PL2)
WORKSURFACE AT 42" A.F.F. AS SHOWN ON PLAN. COUNTER TO
MIMIC CURVE OF WINDOW AS SHOWN AND EXTEND FROM
COLUMN TO COLUMN. PROVIDE MITER EDGE DETAIL AT NORTH
AND SOUTH EDGES TO CREATE WATERFALL ENDS AND PROVIDE
CENTER SUPPORT PANEL )PLI) AS REQUIRED. NO BACK OR
SIDESPLASH. PROVIDE ADDITIONAL MODESTY PANEL TO DISGUISE
WIRING FROM POWER GROMMETS; REFER TO ELECTRICAL PLANS.
VERIFY EXACT DIMENSIONS IN FIELD. NOTIFY SDI IF ADDITIONAL
SUPPORT IS REQUIRED; INTENT IS FOR ANY ADDITIONAL SUPPORT
TO BE AS CONCEALED AS POSSIBLE.
PROVIDE NEW 18"DEEP L-SHAPED PLASTIC LAMINATE )PL2)
WORKSURFACE AT 30" A.F.F. AS SHOWN ON PLAN. PROVIDE 2"
BACKSPLASH )NO SIDESPLASH) AND (2) GROMMETS IN
WORKSURFACE. VERIFY EXACT DIMENSIONS IN FIELD. SUPPORT
COUNTER AS REQUIRED WITH RAKKS EH-1212-FM BRACKET
ATTACHED TO METAL STUDS WITH WOOD BLOCKING AND
DRYWALL INSTALLED OVER VERTICAL SUPPORT. CASEWORK
CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO
INSTALLATION OF DRYWALL. COORDINATE APPROVAL OF SHOP
DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED.
P01 PROVIDE POTABLE HOT AND COLD WATER AND SANITARY
WASTE AND VENT PIPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING.
PROVIDE WATER LINES FOR COFFEE (2), ICE MAKER, AND WATER
DISPENSER. CONFIRM LOCATION WITH TENANT,
SALVAGED SINKS TO BE REINSTALLED IN SAME LOCATION; REUSE
EXISTING PLUMBING IF POSSIBLE.
EAS
WIN
I
® AREA NOT IN CONTRACT ARCHITECTURAL PLAN - WEST WING
❑ AREA OF WORK 0 3' 4' 8' 16'
■ Ra
N
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
O
IRT
CV
Z
Oz
00
N
LL
J
O
CL
a�z
Z
1
Q
V
o
Q
Z
Q
Lu
a
g
Z
111111�
Z
Q
w
O
Z
}
Z
Z
OZ
W
W
CL
d
0
SSUE
DATE
DESCRIPTION
09.06.19
REVIEWSET
09.13.19
PERMITSET
REVISIONS
MAR DATE DB DESCRIPTION
N0.
AR10700017
STATE OF
PROJECT NUMBER
2019.378
PROD. MGR DRAWN BY
1 TTT
4TH FLOOR
WEST WING
ARCHITECTURAL
FLOOR PLAN