Loading...
HomeMy WebLinkAboutFloor Plan W A112ARCHITECTURAL LEGEND NEW CONSTRUCTION EXISTING TO REMAIN TWALL WALL F�� �79d:i1L\\Eli[HEI\TL\RR II PARTIAL HEIGHT WALL an ­Fa WINDOW/SIDELIGHT WINDOW/SIDELIGHT (97 DOOR AND FRAME DOOR AND FRAME (SEE DOOR SCHEDULE) NOTE: IF IN GOOD CON DI➢ON, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. WALL TYPES NOTE: l ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE H UNLESS OTHERWISE NOTED. PROVIDE MOISTURE RESISTANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. H WALL WITH INSULATION 3% METAL STUDS AT I6"O.CJ ONE LAYER OF % TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING 0 DEMISING WALL TO DECK WITH INSULATION 3%8METAL STUDS AT 16' O.C.; ONE LAYER OF SVB TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL DECK; FIBERGLAS SOUND BATT INSULATION INSIDE IDE WALL. PARTIAL HEIGHT WALL 2%" METAL STUDS AT 24" O C.; ONE LAYER OF S54' TYPE "X" GYPSUM BOARD EACH SIDE; REFER TO ELEVATIONS AND SECVON FOR HEIGHT: PROVIDE 1"STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED PLAN NOTES NOTE: NOT ALL PLAN NOTES ARE USED ON EACH SHEET. ALL SCOPE OF WORK IN RESTROOMS TO BE PRICED SEPARATELY AS LANDLORD'S COST. A01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR THRILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. PROVIDE PLYWOOD PHONE BOARD, 4'x8'xi", PAINTED WITH FIRE A02 RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. ONEW FIRE EXTINGUISHER IN RECESSED CABINET TO BE PROVIDED A03 AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. A04 PROVI DE SEPARATE P RIC E FOR ACOUSTICAL S EALANT AT ALL ARCHITECTURAL JOINTS/TRANSITION POINTS FOR INCREASED ACOUSTICAL PROTECTION IN THIS ROOM. PROVIDE ADDITIONAL BLOCKING IN WALLAS REQUIRED FOR A05 TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. rPL:AN)E SEPARATE PRICE FOR RECEPTION DESK ]SHOWN ON O BE BUILT-IN MILLWORK IN LIEU OF FURNITURE. ASSUME RK CONSTRUCTION, PLASTIC LAMINATE WORK E WITH BUILT-IN STORAGE (3 TOTAL IS"WIDE SECTIONSAGE) AND SOLID SURFACE TRANSACTION TOP. GS TO FOLLOW. A07 PROVIDE (5) ADJUSTABLE 16" DEEP WHITE MELAMINE SHELVES ON HEAVY DUTY KV BRACKETS AND STANDARDS, OPROVIDE SEPARATE PRICE FOR 2'Hx3'W SOUNDPROOF A06 WINDOW AT THIS LOCATION. COORDINATE FINAL , SPECIFICATIONS WITH TENANT. PROVIDE %" TEMPERED GLASS WINDOW AT THIS LOCATION WITH BUIIGLAZED PANELS. SEE DIMENSION ON PLAN FOR WIDTH, CONFIRM IN FIELD. FRAME TO MATCH SUITE STANDARD DOORFRAME. PROVIDE NEW 2'-0" DEEP X FULL LENGTH PLASTIC LAMINATE )PL2) WORKSURFACE AT 42" A.F.F. AS SHOWN ON PLAN. PROVIDE 2" BACKSPLASH; NO SIDESPLASH. VERIFY EXACT DIMENSIONS IN FIELD. SUPPORT COUNTER AS REQUIRED WITH APPROPRIATE MOUNTING BRACKETS PER MOUNTING ON BACKSIDE OF WET WALL. DESIGN INTENT IS FOR BRACKETS TO AS CONCEALED AS POSSIBLE. ISLAND TO BE CENTERED ON SOCIAL AREA INSET CONSTRUCTED AS SHOWN, TENANT MAY UTILIZE FURNITURE WALLS (BY FURNITURE VENDOR) ATTHIS LOCATION IN LIEU OF DRYWALL WALLS, PROVIDE NEW MOBILE PARTITION AS NOTED AND PROVIDE ANY A13 ADDITIONAL SUPPORT ABOVE CEILING AS REQUIRED: PARTITION TO BE HUFCOR (OR SIMILAR) SERIES 632 MANUALLY OPERATED PAIRED PANEL PARTITION. PANELS TO BE HINGED TOGETHER IN PAIRS WITH AN STC MINIMUM OF 54. BOTTOM SEALS TO BE MECHANICALLY OPERATED RETRACTABLE BOTTOM SEALS (AUTOMATIC BOTTOM SEALS ARE NOT ACCEPTABLE), MULTI -PLY VINYL TOP SWEEPS AND LEAD PANEL TO HAVE FULL HEIGHT BULB SEALS. FINAL CLOSURE TO BE BY EXPANDABLE LEVER RELEASED FOR CONSTRUCTION r°FCO Si HAVE AN DITION TO THE PANEL'S Subject to compliance with all regulations EQUIRED, DETAILED MOBILE' of State and Local Codes BY OTHERS. T, City of Camel IVM1��LJtD,AC�BDa/�K DATE: \ 10/02/19 GENERAL NOTES I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 3. PROVIDE SEPARATE PRICE FOR MANUAL DRAPER SHADES ON EXTERIOR WINDOWS THROUGHOUT, MATERIAL AND COLOR TBD. WALL TYPICAL WAI METAL STUD EXISTING WIN MULLION PRE -FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT n WALL AT MULLION DETAIL AI 12 NO 1 10 SCALE IN NEW EXPOSED DECK AREA, ENSURE EXISTING DRYWALL EXTENDS TO DECK ALONG THIS WALL. PROVIDE NEW IF REQUIRED. PROVIDE 18" DEEP PLASTIC LAMINATE (FILE) SHELF AT THIS LOCATION AT 42" AFF; DIMENSION TO BE 24" AT LONG EXPOSED END AND 30"AT LONG END MOUNTED TO WALL. MOUNT TO WALL WITH RAKKS EH-1212-FM BRACKET ATTACHED TO METAL STUDS WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER VERTICAL SUPPORT. CASEWORK CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL. COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED. PROVIDE NEW 2'-0' DEEP PLASTIC LAMINATE (PL2) WORKSURFACE AT 42" A.F.F. AS SHOWN ON PLAN. COUNTER TO MIMIC CURVE OF WINDOW AS SHOWN AND EXTEND FROM COLUMN TO COLUMN. PROVIDE MITER EDGE DETAIL AT NORTH AND SOUTH EDGES TO CREATE WATERFALL ENDS AND PROVIDE CENTER SUPPORT PANEL )PLI) AS REQUIRED. NO BACK OR SIDESPLASH. PROVIDE ADDITIONAL MODESTY PANEL TO DISGUISE WIRING FROM POWER GROMMETS; REFER TO ELECTRICAL PLANS. VERIFY EXACT DIMENSIONS IN FIELD. NOTIFY SDI IF ADDITIONAL SUPPORT IS REQUIRED; INTENT IS FOR ANY ADDITIONAL SUPPORT TO BE AS CONCEALED AS POSSIBLE. PROVIDE NEW 18"DEEP L-SHAPED PLASTIC LAMINATE )PL2) WORKSURFACE AT 30" A.F.F. AS SHOWN ON PLAN. PROVIDE 2" BACKSPLASH )NO SIDESPLASH) AND (2) GROMMETS IN WORKSURFACE. VERIFY EXACT DIMENSIONS IN FIELD. SUPPORT COUNTER AS REQUIRED WITH RAKKS EH-1212-FM BRACKET ATTACHED TO METAL STUDS WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER VERTICAL SUPPORT. CASEWORK CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR TO INSTALLATION OF DRYWALL. COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED. P01 PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. PROVIDE WATER LINES FOR COFFEE (2), ICE MAKER, AND WATER DISPENSER. CONFIRM LOCATION WITH TENANT, SALVAGED SINKS TO BE REINSTALLED IN SAME LOCATION; REUSE EXISTING PLUMBING IF POSSIBLE. EAS WIN I ® AREA NOT IN CONTRACT ARCHITECTURAL PLAN - WEST WING ❑ AREA OF WORK 0 3' 4' 8' 16' ■ Ra N THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. O IRT CV Z Oz 00 N LL J O CL a�z Z 1 Q V o Q Z Q Lu a g Z 111111� Z Q w O Z } Z Z OZ W W CL d 0 SSUE DATE DESCRIPTION 09.06.19 REVIEWSET 09.13.19 PERMITSET REVISIONS MAR DATE DB DESCRIPTION N0. AR10700017 STATE OF PROJECT NUMBER 2019.378 PROD. MGR DRAWN BY 1 TTT 4TH FLOOR WEST WING ARCHITECTURAL FLOOR PLAN A112