HomeMy WebLinkAboutCeiling E A121LEGEND
NEW OR RELOCATED EXISTING TO REMAIN
LIGHT FIXTURE, 2'x4', METALUX
LIGHT FIXTURE,
2'x4', PARABOLIC
CRUZE, 3500K
LIGHT FIXTURE, 2'%2',METALUX
no
LIGHT FIXTURE,
2'x2', PARABOLIC
CRUZE, 3500K
UGHT FIXTURE, LED PENDANT,
se
LIGHT FIXTURE,
1'x4', INDIRECT
A
VARYING LENGTHS; REFER TO
PLANS, 3500K
o
FOCAL POINT AVENUE B LED
ee
LIGHT FIXTURE
I'x4', INDIRECT
B
4LENGTH CEIUNG GRID
FLANGE
71
RECESSED LIGHT FIXTURE, LED
r(
RECESSED LIGHT
FIXTURE
3500K
A @
LIGHT FIXTURE, PENDANT. $700
®
LIGHT FIXTURE,
PENDANT
MATERIAL COST/FIXTURE
B ®
LIGHT FIXTURE, PENDANT,$700
®
LIGHT FIXTURE,
PENDANT
MATERIAL COST/FIXTURE
EIGHT FIXTURE, Tx41ED
LIGHT FIXTURE,
1'x4',
®
FIXTURES TO MATCH EXISTING,
PARABOLIC, FIXTURES
TO
3500K
RECEIVE NEW
LED RETROFIT
KITS,3500K
�111��1��1� ®W��I//!�1��1�
IIIII Io�1 11//11„1���
�j11111111�1♦IIIII��II ®�11 �%�i
IIIII/Ilii���11♦�Iii1 ♦Ij`
EXIT UGHT 9XTURE (I EXIT LIGHT FIXTURE
EMERGENCY LIGHT FIXTURE EMERGENCY LIGHT FIXTURE
11/111�1ir�® 1111.�1�11111�
$N3 EIGHT SWITCH, 3-WAY $3 LIGHT SWITCH, 3-WAY
�1111111111�//�II11�EIGHT SWITCH, DIMMER LIGHT SWITCH
%r/11�♦1/1���
$NP SWITCH, PROJECTOR $p SWITCH, PROJECTOR
SCREEN SCREEN
1$NG SWITCH, GARBAGE SWITCH, GARBAGE
$ME SWITCH, E�AUSI FAN $E SWITCH, EXHAUST FAN
11���
DISPOSAL (ABOVE DISPOSAL
�♦1�111111111 ♦♦IIp11 1 ..:�,�
WA
LIGHT CIRCUIT LIGHT CIRCUIT
�1�1��1�111 ♦ ♦-.,�j111
CEIUNG GRID,
SUSPENDED, 2'x2'
GYPSUM BOARD CEIUNG
❑ EXPOSEDTO DECK
CEILING GRID,
r- SUSPENDED, 2'x2'
GYPSUM BOARD CEILING
FJRELOCATED
DIFFUSER,
®
DIFFUSER,
LAY -IN, 2'x2'
LAYJN, 2'x2'
®
RELOCATED DIFFUSER,
m
DIFFUSER,
LAYJN, 4"x4' OR 4"XI'
LAY IN, 4"x4'
EXHAUST FAN, 2'x2'
EXHAUSTFAN,2'x2'
GENERAL NOTES
J R07
J
1
I REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED
EXISTING GRID I32x2 AT II AFF TILES ARE 2x2 ACOUSTICAL LAY
IN TILES REPAIR ANY DAMAGED GRID AND REPLACE ANY
PLAN
NOTES
DAMAGED TILES WITH NEW TO MATCH EXISTING
2. IF IN GOOD CONDITION, EXISTING CEILING TILES SALVAGED FROM
NOTE:
NOT ALL PUN NOTES ARE USED ON EACH SHEET. ALL SCOPE OF WORK IN
DECONSTRUCTION CAN BESUBSTITUTED FOR NEW. PROVIDE LIKE
RESTROOMS TO BE PRICED$EPA RATELY AS LANDLORD'S COST,
CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE
UNIFORM LOOK.
CONTROL OPEN OFFICE AREA LIGHTING WITH SWITCH ATTHIS LOCATION. EACH
R01
QUADRANT TO BE ON ITS OWN SWITCH. PROVIDE MULTIPLE SWITCHES AS REQUIRED;
3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED
CONFIRM FINAL LOCATIONS WITH TENANT.
PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
TRANSITION FROM CEILING GRID i0 EXPOSED CEILING i0 BE A 5' WIDE DRYWALL
THE SPACE CONTAINS SO PERSONS OR MORE. FIXTURES SHOWN ON
R02
B ULKH EA EXTEND I NG FROM 8'-10'AFF TO DECK(PAI NIT I N PTI FLAT FI NISH).
PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS,
TRANSITION TO BE A CLEAN VERTICAL BULKHEAD, FINISHED SUCH THAT
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN
CONTRASTING PAINT COLORS CAN EASILY AND CLEANLY CUT AT WALL TO CEILING
SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI
LINE. VERTICAL FACE OF DRYWALL TO BE PAINTED COLOR OF ADJACENT WALL.
OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT
IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
COORDINATE ALL DETAILS FOR BULKHEAD(INCLUDING HEIGHT) AND ANY
R03
STRUCTURAL REQUIREMENTS FOR MOVABLE WALLS WITH TENANT'S VENDOR.
4. LAYOUT SHOWN IS INTENDED TO MEETASHRAE 90.1 STANDARDS.
CONSULT WITH SDI IMMEDIATELY IF DIMENSIONS OF BULKHEAD WILL VARY FROM
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT
THOSE SHOWN ON PLANS. IF ENGINEERED STRUCTURAL PLANS ARE NEEDED,
INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1,
DRAWINGS BY OTHERS.
CONTRACTOR MUST NOTIFY SDI. OVER 50% OF TH E LIGHTING WILL
BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL
R04
NO CEILING WORK AT THIS LOCATION.
NEED TO BE MET.
DESIGN INTENT IS FOR LINEAR LIGHT FIXTURES TO BE TIED INTO EXISTING RESTROOM
5. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS, PROVIDE
R05
SWITCH.
COMBO UNIT WITH BOTH ULTRASONIC AND INFRARED
TECHNOLOGY WITH A ONE BUTTON OVERRIDE. OCCUPANCY
CLEAN ALL EXPOSED SURFACES AND PREPARE FOR KI3 ACOUSTICAL
SENSORS ARE TO BE LOCATED SUCH THAT OCCUPANCY WITHIN
RO6
SPRAY -APPLIED PAINT AND DRYFALL PAINT jPT5j AS NOTED ON PLAN PER
ANY PORTION OF INCLUDED AREA IS DETECTED. PROVIDE CEILING
MANUFACTURER'S RECOMMENDATIONS. PAINT EXISTING EXPOSED CEILING DECK,
MOUNTED OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED.
EXPOSED DUCTWORK, SPRINKLER PIPING, JUNCTION BOXES, CONDUIT, STRUCTURAL
BEAMS AND FIREPROOFING IN ACCORDANCE WITH NFPA 13 6.3.8. PROVIDE RIGID
6. ALL EXISTING AND NEW DEVICES AND FACE PLATES TO BE WHITE.
SPIRAL DUCT AND ROUND SUPPLY DIFFUSERS AS REQUIRED IN THIS AREA.
REPLACE WITH NEW AS REQUIRED. WHERE POSSIBLE, GANG
MULTIPLE SWITCHES TO ACCOMMODATE MULTI -SWITCH PLATE
PROVIDE NEW CEILING GRID AND TILE AS SHOWN TO MATCH AND ALIGN WITH
WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN.
R07
EXISTING SUCH THAT NEW AND EXISTING CEILINGS APPEAR CONTINUOUS.
7. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
PROVIDE SWITCH BANKS AT THESE LOCATIONS. INTENT IS FOR ALL LIGHTING IN
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
ROB
TOWN HALL TO BE DIMMABLE AND SEPARATED INTO (2) ZONES PER MIDDLE
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
MOVABLE WALL. COORDINATE REQUIREMENTS WITH TENANT.
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
ENSURE LIGHTING IS 3500K CCi AND ALL FIXTURES TO BE DIMMABLE. PROVIDE
1 Cep _DARTIESIFADDITIONAL
RELEASED FOR CONSTRUCTION
R09
ADDITIONAL CIRCUITING CAPABILITY FOR FUTURE LIGHTING COORDINATE ALL
PLANS CAN BE FILED AND
DETAILS WITH TENANT.
DES.
Subject to compliance with all regulations
PROVIDE APPROPRIATE CEILING WORK FOR TENANT'S CEILING PROJECTOR AND
of State and Local Codes
ft10
MOTORIZED, RECESSED PROJECTOR SCREEN.
City of Conical 000000010
DATE: 10/02/19
\
z
R07 lz:) /
cz
r /
J J /
R07
® AREA NOT IN CONTRACT
❑ AREA OF WORK
MECHANICAL NOTES
I. MECHANICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING
H.V.A.C. DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE
SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS
BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY
APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT
ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE
INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.
3■■o■■o■■m
0
No
No
on
■■■■■■■■■■
q■■MEEM■■M
All ZI
^ R04 D
4 p
C
I \ ® N
�J R02 20
;-0- _ 2
r
\
8 7� RO6 \
14'-0"
1 \
B 14'-0"
O
14' 0" 1 22 0" /
/ A
20
14' 0' 14' 0'
A / \ A
REFLECTED CEILING PLAN - EAST WING
0 2' 4' 6' 16;
EAST WEST
WING, WING
I
O
ou
N
V O
O
U
U
N
n Z
^'
o 0
P Q^
0
w O M
U
� p Q
Qa
C
THIS DRAWING, AND TH E IDEAS,
DESIGNS AND CONC EPTS CONTAINED
HEREIN. ARE THE Ex CLUSIVE
INTELLECTUAL PROPERTY OF SCHOTT
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
0
N
ZO z_
rix; O O
�= 0
CL
Q� z
a Q
V�o
Q z
r
0 � �
LU
a g
z
VI aaaaaaaa Z Q
mO
Z Un
z
�¢ Z z
O W W
CL
d
0
REVISIONS
MARK DATE I DB DESCRIPTION
I
No.
AR10700117
STATE OF
PROJECT NUMBER
2019.378
PROJ.MGR DRAWN BY
EH AMM
I
4TH FLOOR
EAST WING
REFLECTED
N A1l 21