Loading...
HomeMy WebLinkAboutSpring Mill Rd_Current Plans (A1, CC1-CC6)Know what's AeccDbSurfaceTin in W11-2 SIGN (36" X 36") 2C/8 CARMANAH 24-HOUR SOLAR LED FLASHING BEACON VERTICAL POLE MOUNT STYLE *5'-9" min3'-3"11'-6"14'-0"RECTANGULAR RAPID FLASHING BEACON * 5C/14, 2C/8 W16-7 SIGN (24" X 24") R10-25 SIGN (9" X 12") CARMEL DECORATIVE PEDESTAL ** PEDESTRIAN PUSH BUTTON * 2-5C/14 CARMEL DECORATIVE PEDESTAL BASE ** GROUND BUSHING * EXISTING GROUND 2-W11-2 SIGN (36" X 36") 2C/8 CARMANAH 24-HOUR SOLAR LED FLASHING BEACON VERTICAL POLE MOUNT STYLE *5'-9" min3'-3"11'-6"14'-0"2-RECTANGULAR RAPID FLASHING BEACON * 5C/14, 2C/8 2-W16-7 SIGN (24" X 24") R10-25 SIGN (9" X 12") CARMEL DECORATIVE PEDESTAL ** PEDESTRIAN PUSH BUTTON * 2-5C/14 CARMEL DECORATIVE PEDESTAL BASE ** GROUND BUSHING * EXISTING GROUND PEDESTAL MOUNTED FLASHING BEACON - MEDIAN NOT TO SCALE 2" GAL. STEEL CONDUIT STUB 2" GAL. STEEL CONDUIT STUB 2" GAL. STEEL CONDUIT STUB 3"3"SIGNAL PEDESTAL FOUNDATION TYPE A (per INDOT Std Drawing E 805-SGCF-03) SIGNAL PEDESTAL FOUNDATION TYPE A (per INDOT Std Drawing E 805-SGCF-03) PEDESTAL MOUNTED FLASHING BEACON - OUTSIDE NOT TO SCALE PEDESTRIAN ISLAND OPENING NOT TO SCALE 8'-0" 3"2'-0" Median Cut Through Ramp 6"Grass Median Grass Median Included in "PEDESTRIAN RECTANGULAR RAPID FLASHING BEACON WITH PUSH BUTTON ON PEDESTAL" Included in "BLACK PEDESTAL, 14'" * ** Included in "PEDESTRIAN RECTANGULAR RAPID FLASHING BEACON WITH PUSH BUTTON ON PEDESTAL" Included in "BLACK PEDESTAL, 14'" * **8'-0"848.06 848.09 2.0%2.0% 2.0%2.0% 2.0% 2.0% 10'-7" 7.5% 7.7%0.4%0.1%2-5C/14 4-5C/14 37 37 Existing Multi-use Path4'-0"4'-0" 3'-0" 3'-0" 849.17 849.18 849.09 849.09 849.10 849.10 849.09 849.09 849.10 849.10 848.74 848.74 848.75 848.75 848.74 848.74 848.75 848.75 4'-0"9'-4" 1.0% 1.0% 848.79 848.7810'-0"8'-0"12'-0"850.01 849.86 848.96 848.95 849.10 849.11 1.5% 1.5%0.1%7.2%7.5%7.5%7.4%1.3% 1.5% 849.82 849.69 10'-0" 10'-0"8'-0"8'-0"13'-4" 13'-2" 2.0% 2.0%2.0% 2.0% 1.5% 1.5% 2.0% 2.0% 860.40 860.390.1%859.57 859.57 859.58 859.58 859.65 859.66 859.57 859.57 859.58 859.58 859.23 859.23 859.24 859.24 859.23 859.23 859.24 859.24 3'-0" 3'-0" 859.31 859.32 4'-0" 8.2% 8.1%8'-0"8'-0"8'-0" 1.5% 1.5% 859.31 859.43 859.82 859.30 859.42 859.94 859.92 859.80 5'-0"6.4%6.3%6.3%0.1%6.4%4'-0"4'-0" 2-5C/14 4-5C/14 37 37 File Name: \\ucs04fs\road\roadteam3\C3D\16-404\Road\Dwg\Plans\Typical Sections.dwg Plot Date: 2/27/2017 Plotted By: Nimz, John1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKWRCJNII WRC WRC AS SHOWN AS SHOWN - - - - 8-A 200 16-ENG-52 PEDESTRIAN CROSSING DETAILS CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN PEDESTRIAN CROSSING @ 141+33 "PR-A" PEDESTRIAN CROSSING @ 185+50 "PR-A" LEGEND 37 Proposed Spot Elevation600.00 600.50 600.00 Top Curb/Bottom Curb Proposed Spot Elevation Transverse Marking, Thermoplastic, Crosswalk Line, White, 24" SCALE: 1" = 5' SCALE: 1" = 5' F Sidewalk, 4" on 4" Compaceted Agg, No 53, Base Pedestrian Rectangular Rapid Flashing Beacon with Push Button on Pedestal 2 in. Galvanized Steel Conduit Added This Sheet3 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII I I I I IIIIIIIIIIIIIIIIIIIII I I I I I I I I I I I I III I IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII I I I I IIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIII I I I I IIIIIIIIIIIIIIIIIIIII I I I I I I I I I I I I III I IIIIIIIIII I I I I I I I I I I I I I I I I I I I I I I III I 830 835 840 845 850 855 860 830 835 840 845 850 855 860 846.85846.8847.32847.3847.88847.9848.37848.4848.49848.5847.78847.8847.07847.1845.52845.5845.62845.6845.47845.5847.64847.6847.13847.1846.50846.5126+00 127+00 128+00 129+00 130+00 131+00 -1.50%+0.50% PVI STA. = 131+10.00 PVI ELEV. = 844.64 V.C. = 305' +0.50% PVI STA. = 131+10.00 PVI ELEV. = 844.64 V.C. = 305' End Profile Sta. 127+18.79 "PR-A" Elev. 847.65 Profile Grade Profile Grade Begin Profile Sta. 129+50.64 "PR-A" Elev. 847.02 See Roundabout Grading Details 105 107 108 112 11551+00420+68 30.1, CONCRETE MON. FOUND420+67.3 32.5, WOVEN WIRE FENCE420+79.3 31.1, WATER METER421+39.7 12.6, MAILBOX421+43.6 17.5, EDGE OF WOODS421+50.2 29.4, 12" /ASH TREE421+71.7 17.9, EDGE OF WOODS423+01.4 24.8, POWER POLE423+45.7 16.8, 12" RCP424+33.9 71.2, 6" CON. TREE 424+23.9 78.6, 6" CON. TREE 423+35.1 47.1, SAN. M.H. 423+33.2 28.1, POWER POLE423+32.9 25.7, TBM #108 423+22.7 32, SIGN /STREET 423+19.9 41.3, STOP SIGN423+19.2 35.7, GUY ANCHOR 423+20.8 80.7, POWER POLE423+55.3 25.7, GUY ANCHOR 422+56.3 52.3, WATER PED.422+58.3 59.3, FIRE HYD. 422+60.7 59.7, WATER VALVE 422+69.7 47.4, WATER SERVICE VALVE422+87.3 36.5, WATER M.H.422+81.7 32.1, POWER POLE422+83.7 23.3, POWER POLE422+83.6 23.7, POWER POLE 422+80.1 23.3, GUY POLE 422+86.2 25.1, TELE. PED.422+56.4 33.2, TELE. PED. 422+52.9 50.5, POST 422+53.8 49.4, EDGE OF WOODS 422+34.7 22.8, GUY ANCHOR 423+03 0, RR SPIKE FOUND421+27.3 26.4, 12" DEC. TREE 421+00.8 26.5, 30" /MAPLE 420+89.6 38.7, WATER VALVE 420+89.5 40.4, FIRE HYD. 420+52.3 47.7, POWER POLE420+51 53.5, GUY ANCHOR P.O.T. 17+00.00 "S-1-A" (woods) (woods) (woods) (grass) (grass) (asph.)(asph.)(asph.)(asph.)(gravel) (grass) 12" RCP (grass) (grass) (grass) (grass) (woods)(gravel)(grass) (grass) (conc. sidewalk)126+00127+00128+00129+00130+00131+0018" PVC SPRING MILL ROAD Line "A" & Section Line 15' SIGHT DISTANCE AND UTIL. ESMT. Section 4, T17N, R3E Clay Township Hamilton County, IN Section 3, T17N, R3E Clay Township Hamilton County, IN (grass) (woods) (woods) (woods) 15' UTIL. & DRAIN. ESMT.423+21.8 23.8,GUY ANCHOR423+06.4 36.5,GUY ANCHOR423+03 33.1,WOVEN WIRE FENCE423+02.8 45.2,CONC. MON. FOUND423+79.5 64.6,WROUGHTIRON FENCE425+24.4 41.1,WROUGHTIRON FENCE424+62.1 40.3,WROUGHTIRON FENCE425+88.9 43.6,WROUGHTIRON FENCEApp. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W Line "S-1-A" & 1/4 Section LineLine "PR S-1-A"SPRING MILL ROADLine "A" & Section Line Line "PR-A" Line "PR-A" K K 15 16 15 16 F1 26 14.0'14.0'5.5'7.0'5.5' 5. 0 ' T y p . 8. 0 ' T y p . Refer To Roundabout Geometric Details Sheet For Alignments Of Curb/ Pavement Edges Refer To Roundabout Geometric Details Sheet For Alignments Of Curb/ Pavement Edges420+15.2 12.6,GAS MARKER POST425+81.4 67.3,6" CON. TREE425+58.9 26.5,POWER POLE15 16 16 15 22 K 15 15 K 16 15 K 15 K 16 15 5.0' Typ. 8.0' Typ. 26 F1 26 26 F1 F1 F1 F1 26 26 26 15 18 17 18 17 K1 K1 K F1 8.0' Typ.+62.5+62.926 C1 C1 CR +29.9 +33.2 +36.2 +30.2 CR CR CR CR +39.3 +33.7 +39.4 CR CR +35.6 CR 5.0' Typ. 8.0' Typ.5.0' Typ.8.0' Typ.424+06.9 79,6" CON. TREE423+99.4 91.2,4" CON. TREE26 26422+60.2 16.2,MAILBOX26 26 26 F126 423+85.7 102.5,4" CON. TREE26 104 106 111 113 116 114(woods)421+64.7 25.8,18" DEC. TREE424+51.2 23.9,POWER POLE424+72 69.3,6" DEC. TREE425+66.4 60.6,GUY ANCHOR422+24.9 16.4,CABLE TV PED.422+19.7 12.6,SIGN /INFO425+66.4 47.3,POWER POLE425+31.1 68.9,8" DEC. TREE425+12.9 25.4,FIRE HYDRANT425+12.2 31.9,WATER VALVE424+88.2 66.6,6" CON. TREE425+57 69.1,6" CON. TREE424+13.2 39.5,EDGE OF WOODS424+20 27,GAS VALVE26 26 26 26 +88.6, Class I Drive W= 10.0' +58, Class I Drive W= 10.0' R/W R/W R/W R/ W R/W 34+00 35+00 30' LIMITEDDRAIN. ESMT.DUKE ENERGY ESMT.DUKE ENERGY ESMT. Line "PATH" 126+00 127+00 128+00 129+00 130+00 131+00 105 107 108 112 115 F1 F18.0' Typ. 8. 0 ' T y p . (woods) DO NOT DISTURB FENCE 5.0'9.7'5.0'13.1'109 110 264.0'+37.33.0'11.0'9.1'+08.122 4.2'+84.82.8'22 K 9.0'22.0'15.0'File Name: \\ucs04fs\road\roadteam3\C3D\16-404\Road\Dwg\Plans\Plan & Profile.dwg Plot Date: 9/6/2017 Plotted By: Allison, Andy1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE P:\C3D\16-404\Road\Dwg\Plans\wrc2.JPG DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKHEKJNII WRC WRC 1" = 20' 1" = 5" - - - - 36 200 16-ENG-52 PLAN & PROFILE LINE "PR-A" CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN See Plat No. 1 sheets for Right Of Way information. Line "PR-A" to be constructed. All proposed construction station/offsets are described from Line "PR-A" unless otherwise noted. LEGEND HMA for Approaches 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" Placed w/ Minimum Of 3 Lifts, on Multi-Use Path 110 #/Sys HMA Surface, Type "A" on 330 #/Sys HMA Intermediate, Type "A" on 5" Compacted Aggregate, No. 53, Base Truck Apron Decorative PCCP, 7" 165 #/Sys HMA Surface, Type "C" on 275 #/Sys HMA Intermediate, Type "C" on 385 #/Sys HMA Base, Type "C" on 250 #/Sys HMA Intermediate, OG, Type "C" on 330 #/Sys HMA Base, Type "C" Milling, Asphalt, 1 12" 165 #/Sys HMA Surface, Type "C" Curb & Gutter, Type II Curb & Gutter, Type III Roll Curb Concrete Center Curb, Type D Nursery Sodding D1 F1 F K K1 17 22 26 15 16 RPCCP for Approaches, 9" on Subgrade Treatment, Type II C3 PCCP for Approaches, 6" on Subgrade Treatment, Type II C1 M Integral Barrier Curb18 Curb Ramp, ConcreteCR Sidewalk, 4" on 4" Compacted Aggregate, No. 53, Base HMA for Widening 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" W Revised Plan & Profile1 1 Subgrade Treatment, Type IB Placed w/ Minimum Of 3 Lifts, on Subgrade Treatment, Type IB 1 Matchline - Sta. 131+25 "PR-A"Matchline - Sta. 125+00 "PR-A"Revised Plan & Profile3 Added Median Break3 Moved Str. No. 1053 Moved Str. No. 1073 Moved Str. No. 1073 Revised Driveway5 Revised Driveway5 830 835 840 845 850 855 860 830 835 840 845 850 855 860 846.21846.2846.36846.4846.49846.5846.44846.4846.52846.5846.72846.7846.92846.9847.08847.1847.16847.2847.15847.2847.12847.1847.21847.2847.33847.3132+00 133+00 134+00 135+00 136+00 137+00 +0.50%+0.50%Existing Ground Profile Grade 133130127126123118121 137427+14.2 98.1, 12" RCP427+38.1 45.1, TELE. PED.427+34.7 35, SAN. M.H.427+71.1 44.1, STOP SIGN428+20.5 71.3, TELE. PED.428+19.9 70.5, POWER POLE428+92.9 65.4, 20" CON. TREE429+15.2 63.1, 12" DEC. TREE429+20.9 49.2, BRICK COLUMN429+89.6 32.9, CABLE TV PED.429+94.9 34.3, CABLE TV PED.432+38.6 59.3, TBM #107 432+39.5 59.9, POWER POLE431+31.5 48.6, SAN. M.H. 431+35 60.9, POWER POLE431+30.8 92.7, SAN. M.H. 430+35 24.1, GUY ANCHOR 430+02.4 23, FIRE HYDRANT429+86.5 24.5, POWER POLE430+28.2 59.7, POWER POLE429+79.7 60, GUY ANCHOR 429+59.5 21, 12" RCP429+59.4 77.8, 12" RCP429+48.9 62.8, TREE ROW12" RCP12" RCP12" R C P 12" RCP(grass) (grass) (grass) (grass)(ls)(grass) (grass) (grass) (grass) (grass) (gravel) (grass) (grass) (grass) (grass) (asph.) (asph.) (grass) (conc.) (l s ) (grass) (grass) (gravel) (conc.) (a sph . )BURLINGTONLN.132+00133+00134+00135+00136+00137+008" PVC18" PVC8" PVC10" PVCSPRING MILL ROAD Line "A" & Section Line Line "PR-A" Section 4, T17N, R3E Clay Township Hamilton County, IN Section 3, T17N, R3E Clay Township Hamilton County, IN 30' DRAIN. ESMT.429+59.7 0.3, MAG NAILW/WASHER FOUND15' UTIL. & DRAIN. ESMT.15' UTIL. & DRAIN. ESMT. 15' UTIL. & DRAIN. ESMT.15' UTIL. &DRAIN. ESMT.15' UTIL. &DRAIN. ESMT.(conc. sidewalk)426+52.4 45.9,WROUGHTIRON FENCE427+16.2 48,WROUGHT IRON FENCEApp. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W428+40.8 29.8,BEEHIVE INLET+09.3 69.5' R= 40.0' +42.3 69.5' R= 40.0'+40.6 69.7' R= 40.0'428+64.3 54.6,12" DEC. TREE428+56.4 50,2X2 BRICKCOLUMN428+55.2 69.4,4" CON. TREE29.5'+19.629.5'+09.35.5'24.0'+09.326 8.0' Typ. 26 14.0'5.5'+42.314.0'5.5'+09.324.0'5.5'+42.314.0'5.5'+48.61.5'14.0'5.5'+30.622+40.614.0'F1 26 8.0' Typ.24.0'+42.329.9'+44.65.5' 1.5' 22 18.0'+42.326 K 15 15 K K 15 16 15 16 K K 26 15 16 15 16 8.0' Typ. 133 137 134 130 135 132 127 131 129 128 125 126 124119122 117 123 120 426+28.1 68.4,6" CON. TREE426+45.7 77,12" RCP426+46.5 20.3,12" RCP426+53.8 70.8,4" CON. TREE426+78.6 71.5,8" DEC. TREE426+87.9 24.4,POWER POLE426+29.3 26.8,BEEHIVE INLET426+45.2 80.1,12" RCP427+33.5 51.1,SAN. M.H.427+71.6 31.7,WATER VALVE428+11.7 65,TREE ROW428+07.7 26.9,POWER POLE428+04.3 68.2,4" DEC. TREECR CR CR F1 26 26 5.0' Typ. 8.0' Typ.F1 5.0' Typ. 8.0' Typ. F1 F1428+08.6 42.4,STREET SIGN+91, Street Appr. W= 21.8' D1 DUKE ENERGY ESMT. DUKE ENERGY ESMT. DUKE ENERGY ESMT. 132+00 133+00 134+00 135+00 136+00 137+00 118 121 +72.35.5' Remove Cap Pipe Remove Cap Pipe Remove K FF Cap Pipe 5.5'+27.61.5' 22+19.614.0'+15.5 71.3' R= 42.0' CR K 846.30 846.72 847.12 847.37 847.51 847.58 847.70847.62847.49847.24846.84846.42 File Name: \\ucs04fs\road\roadteam3\C3D\16-404\Road\Dwg\Plans\Plan & Profile.dwg Plot Date: 2/27/2017 Plotted By: Nimz, John1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKHEKJNII WRC WRC 1" = 20' 1" = 5" - - - - 37 200 16-ENG-52 PLAN & PROFILE LINE "PR-A" CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN See Plat No. 1 sheets for Right Of Way information. Line "PR-A" to be constructed. All proposed construction station/offsets are described from Line "PR-A" unless otherwise noted. LEGEND HMA for Approaches 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" Placed w/ Minimum Of 3 Lifts, on Multi-Use Path 110 #/Sys HMA Surface, Type "A" on 330 #/Sys HMA Intermediate, Type "A" on 5" Compacted Aggregate, No. 53, Base Truck Apron Decorative PCCP, 7" 165 #/Sys HMA Surface, Type "C" on 275 #/Sys HMA Intermediate, Type "C" on 385 #/Sys HMA Base, Type "C" on 250 #/Sys HMA Intermediate, OG, Type "C" on 330 #/Sys HMA Base, Type "C" Milling, Asphalt, 1 12" 165 #/Sys HMA Surface, Type "C" Curb & Gutter, Type II Curb & Gutter, Type III Roll Curb Concrete Center Curb, Type D Nursery Sodding D1 F1 F K K1 17 22 26 15 16 RPCCP for Approaches, 9" on Subgrade Treatment, Type II C3 PCCP for Approaches, 6" on Subgrade Treatment, Type II C1 M Integral Barrier Curb18 Curb Ramp, ConcreteCR Sidewalk, 4" on 4" Compacted Aggregate, No. 53, Base HMA for Widening 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" W Revised Plan & Profile1 1 Subgrade Treatment, Type IB Placed w/ Minimum Of 3 Lifts, on Subgrade Treatment, Type IB 1 Matchline - Sta. 137+50 "PR-A"Matchline - Sta. 131+25 "PR-A"Revised Plan & Profile3 Added Street Approach, Revised Storm Structures Added Spot Elevations 3 Revised Storm Structures3 830 835 840 845 850 855 860 830 835 840 845 850 855 860 847.33847.3847.58847.6848.00848.0848.19848.2848.39848.4848.63848.6848.96849.0849.30849.3849.29849.3849.08849.1848.88848.9848.96849.0849.30849.3138+00 139+00 140+00 141+00 142+00 143+00 -0.35% PVI STA. = 140+75.00 PVI ELEV. = 849.45 V.C. = 250' PVI STA. = 143+50.00 PVI ELEV. = 848.50 V.C. = 225' -0.35% PVI STA. = 140+75.00 PVI ELEV. = 849.45 V.C. = 250' PVI STA. = 143+50.00 PVI ELEV. = 848.50 V.C. = 225' Existing Ground Profile Grade 154151148144 -0.35%+0.50% 139 142 437+20.2 26.6, GAS MARKER POST437+43.5 16.8, STORM M.H.437+42.7 31.4, BEEHIVE INLET437+31.1 47.6, STORM M.H.438+63.8 26.8, 1" DEC. TREE 438+33.7 26, 1" DEC. TREE 438+33.8 45.7, SAN. M.H. /BURIED 4'438+12.6 71.4, CANOPY438+03.4 71.3, CANOPY437+82.5 66.1, PINE ROW437+55.7 65.9, TREE ROW437+31.4 58.5, 12" RCP437+32.7 136.1, INLET 437+30.2 49.8, 12" CMP437+43.8 22.1, 1" DEC. TREE 437+74.5 23.2, 1" DEC. TREE 438+04.4 24.5, 1" DEC. TREE 438+03.4 52.8, PINE ROW438+00.5 60.3, POWER POLE437+12.3 78.1, 4" DEC. TREE 437+00.8 66.1, TREE ROW437+14.5 20.2, 1" DEC. TREE 436+84.7 20, 1" DEC. TREE 436+54.2 20.4, 1" DEC. TREE 436+25.2 20.7, 1" DEC. TREE 436+38.9 66, PINE ROW436+76.6 61.7, PINE ROW436+69.1 60.9, POWER POLE436+17.8 51.9, TREE ROW436+16.1 62, BUSH ROW436+12.4 71.2, CANOPY /CART CORAL 436+04.1 70.9, CANOPY 435+94.4 21.4, 1" DEC. TREE 435+64.8 20.8, 1" DEC. TREE 435+64.5 60.1, POWER POLE435+67.7 70.9, CURB INLET435+13.3 70.2, CURB INLET435+30.7 78.7, 4" DEC. TREE 435+29.6 47.7, SAN. M.H. 435+34.4 21.1, 1" DEC. TREE 435+04.4 21.3, 1" DEC. TREE 434+34 24.7, FIRE HYDRANT434+35 28.8, WATER VALVE434+14.5 25.6, 1" DEC. TREE 434+43.9 22.6, 1" DEC. TREE 434+69.9 59.9, POWER POLE434+73.9 21.6, 1" DEC. TREE 433+96.3 70.6, CURB INLET433+96.7 53.1, 12" CMP433+72.2 58.8, TELE. PED. 433+70.4 60.2, POWER POLE433+45.9 54.2, TREE ROW433+16.8 78.1, 12" DEC. TREE 433+22.8 67.8, 12" DEC. TREE 433+12.1 63.6, 12" DEC. TREE 433+13.4 91.9, BUSH ROW432+90 58.5, STOP SIGN12" RCP12" RCP12" RCP12" RCP 12" RCP 12" CMP1 2 " RC P 12" RC P12" RCP (grass)(grass) (grass) (asph.) (asph.) (ls)(ls)(ls) (ls) (gravel) (gravel) (gravel) (gravel) (asph.)(asph.) (conc.) (conc.)(asph.)(asph.) (asph.)(asph.) (grass) (grass) (grass)(grass)138+00139+00140+00141+00142+00143+0018" PVC 18" PVC 8" PVCSPRING MILL ROAD Line "A" & Section Line Line "PR-A" Section 4, T17N, R3E Clay Township Hamilton County, IN Section 3, T17N, R3E Clay Township Hamilton County, IN App. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W (asph.)(asph.)(asph.)(asph.) +25.1 69.7' R= 40.0'432+89.9 49.9,CAPPED REBAR FND./STRUCTURE PT432+85.4 64.8,CAPPED REBAR FND./STRUCTURE PT29.5'+25.15.5'14.0'+25.129.5'5.5' 1.5'12"RCP+91.15.5'+09.15.5'14.0'+40.9+41.114.0'+04.55.5' 1.5'18.0'K K 15 15 16 26 16 K K 15 15 16 26 16 K 15 15 K 15 15 8.0' Typ.8.0' Typ. 22 22 155 156 147 146 152149 150 153 144 154 148 151142 143 139 140 434+87.7 15.6,CABLE TV PED.CR 438+33.9 72.4,SAN. M.H.+68, Mod. Class III Drive W= 42.6' C3 432+64.1 34.7,WATER VALVE432+78.6 138.7,MAG SPIKE FOUND432+96.5 67.8,GAS MARKER POST433+04.7 84.6, 12" DEC. TREE433+07.9 76.4, 12" DEC. TREERemove Remove Remove F1 F1 10.0' Typ.F1 DUKE ENERGY ESMT.DUKE ENERGY ESMT. 138+00 139+00 140+00 141+00 142+00 F1 ENTRY SOUTHOF BRIDGES II143 +21.5 71.5' R= 42.0' CR +69, Street Appr. W= 41.4' D1 +17.1+35.114.0'848.25 848.37 848.50 848.62 848.85 848.97 849.22 849.34 847.58 847.70 File Name: \\ucs04fs\road\roadteam3\C3D\16-404\Road\Dwg\Plans\Plan & Profile.dwg Plot Date: 2/27/2017 Plotted By: Nimz, John1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKHEKJNII WRC WRC 1" = 20' 1" = 5" - - - - 38 200 16-ENG-52 PLAN & PROFILE LINE "PR-A" CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN See Plat No. 1 sheets for Right Of Way information. Line "PR-A" to be constructed. All proposed construction station/offsets are described from Line "PR-A" unless otherwise noted. LEGEND HMA for Approaches 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" Placed w/ Minimum Of 3 Lifts, on Multi-Use Path 110 #/Sys HMA Surface, Type "A" on 330 #/Sys HMA Intermediate, Type "A" on 5" Compacted Aggregate, No. 53, Base Truck Apron Decorative PCCP, 7" 165 #/Sys HMA Surface, Type "C" on 275 #/Sys HMA Intermediate, Type "C" on 385 #/Sys HMA Base, Type "C" on 250 #/Sys HMA Intermediate, OG, Type "C" on 330 #/Sys HMA Base, Type "C" Milling, Asphalt, 1 12" 165 #/Sys HMA Surface, Type "C" Curb & Gutter, Type II Curb & Gutter, Type III Roll Curb Concrete Center Curb, Type D Nursery Sodding D1 F1 F K K1 17 22 26 15 16 RPCCP for Approaches, 9" on Subgrade Treatment, Type II C3 PCCP for Approaches, 6" on Subgrade Treatment, Type II C1 M Integral Barrier Curb18 Curb Ramp, ConcreteCR Sidewalk, 4" on 4" Compacted Aggregate, No. 53, Base HMA for Widening 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" W Revised Plan & Profile1 1 Subgrade Treatment, Type IB Placed w/ Minimum Of 3 Lifts, on Subgrade Treatment, Type IB 1 Matchline - Sta. 143+75 "PR-A"Matchline - Sta. 137+50 "PR-A"Revised Plan & Profile3 Added Pedestrian Crossing, See Details Sheet 8-A3 Revised Storm Structures3 Added Street Approach, Revised Storm Structures Added Spot Elevations 3 Revised Storm Structures3 835 840 845 850 855 860 865 835 840 845 850 855 860 865 849.82849.8850.73850.7852.15852.1853.08853.1853.35853.3853.30853.3853.32853.3853.50853.5853.89853.9854.20854.2853.93853.9853.60853.6853.06853.1144+00 145+00 146+00 147+00 148+00 149+00 +2.00% +0.50% -1.10% PVI STA. = 145+90.00 PVI ELEV. = 853.29 V.C. = 225' PVI STA. = 148+55.00 PVI ELEV. = 854.61 V.C. = 250' +2.00% +0.50% -1.10% PVI STA. = 145+90.00 PVI ELEV. = 853.29 V.C. = 225' PVI STA. = 148+55.00 PVI ELEV. = 854.61 V.C. = 250' Existing Ground Profile Grade 158 161 163439+87.3 75, SAN. M.H.440+79.9 36.6, INLET445+45.1 64.4, 4" DEC. TREE 445+36.6 29.5, 4" DEC. TREE 445+04.2 27.5, 4" DEC. TREE 444+78.6 25.9, 4" DEC. TREE 444+51.7 22.8, 4" DEC. TREE444+69.6 23.6, SIGN /WARNING444+67.9 38.6, ELEC. M.H.444+35.2 66.3, 4" DEC. TREE444+37.2 55.6, HIGH MAST TOWER444+19.9 72.5, FIRE HYDRANT444+25.2 46.1, SAN. M.H.444+04.3 40, RISER POLE444+14 28.1, WATER VALVE444+13.7 19.6, FIRE HYDRANT444+21 21.7, 4" DEC. TREE443+85.5 40.4, RISER POLE443+82.8 43.6, GUY ANCHOR443+59.1 40.5, RISER POLE443+29.8 23, 4" DEC. TREE 443+39.7 60.9, GUY ANCHOR 443+10.2 59.7, POWER POLE444+19.8 32.5, WATER VALVE443+94.9 61.2, 4" DEC. TREE444+09.3 75.5, FIRE HYDRANT444+11.4 75.6, WATER VALVE442+99 22.1, 4" DEC. TREE 442+69.3 24.7, 4" DEC. TREE 442+51.3 59.9, POWER POLE442+16 25.6, 4" DEC. TREE 441+83 36.5, WATER VALVE441+47.6 60, POWER POLE441+33.4 46.3, SAN. M.H.441+23.3 43, STOP SIGN440+78 50.1, MAG NAIL FOUND 440+50.7 59.9, POWER POLE440+14.3 25.2, 4" DEC. TREE440+19 57.1, BEEHIVE INLET439+83.9 25.8, 4" DEC. TREE 442+36.8 24.9, 4" DEC. TREE 440+16.7 138.2, INLET439+35.6 30.3, WATER VALVE439+26.7 27.1, 1" DEC. TREE439+21.4 27.5, FIRE HYDRANT439+21.3 29.2, WATER VALVE439+15.5 60.8, POWER POLE438+94.2 27.3, 1" DEC. TREE438+75.8 59.6, 12" RCP12" RCP12" RCP12" RCP (grass)(grass)(grass) (grass)(asph.)(asph.)(under construction)(ls) (ls) (ls) (ls) (asph.) (asph.) (asph.) (conc.) (asph.) (asph.) (asph.) (grass) (grass) (grass) (grass) (grass) 18" PVC 18" PVC 6" PVC6" PVC144+00145+00146+00147+00148+00149+00150+008" PVC 8" PVCSPRING MILL ROAD Line "A" & Section Line Line "PR-A" Section 4, T17N, R3E Clay Township Hamilton County, IN Section 3, T17N, R3E Clay Township Hamilton County, IN App. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W +56.4 71.2' R= 41.5' +41.1 71.0' R= 41.5' +08.6 69.5' R= 40.0' +04.5 69.7' R= 40.0'441+19.5 49.9,CAPPED REBAR FND./STRUCTURE POINT5.5'24.0'5.5'+40.45.5'+70.429.5'+56.41.5'28.0'24.0'+10.65.5' 1.5'28.0'+80.624.0'+08.629.5'19.5'+56.429.5'+08.619.5'+08.615 K 15 15 K 26 15 16 15 16 K K 15 22.0'19.5'22.0'19.5'K 15 16 K 16 15 22.0'22.0'K 16 15 16 4.0'440+03.9 70.7,SPRINKLER BOX440+03.8 68.9,SPRINKLER BOX440+03.7 71.5,SPRINKLER BOX439+80.582.6, 4"DEC. TREE439+37.7 59.3,WATER VALVE439+21.3 83.2,6" DEC. TREE161 162 164 163 158 159 4.0' CR CR CR CR 441+16.9 62.5,6' C.L.T.F.RemoveRemove 10.0' Typ.F1(asph.) +99, Mod. Class III Drive W= 42.6' C3 +57, Street Appr. W= 21.8' D1 22 DUKE ENERGY ESMT.DUKE ENERGY ESMT. 144+00 145+00 146+00 147+00 148+00 149+00+04.5F1F1 163 164 P.C. +40.2 20.4' P.T. +67.9 26.0' P.I. +03.5 27.5'R575.0'P.T. +80.7 4.0' P.I. +41.9 4.0'R550.0'R596.0'P.C. +76.7 19.5' P.I. +47.0 18.2'R600.0'P.T. +18.4 25.4' P.T. +45.1 4.0' P.C. +03.5 4.0'P.I. +24.3 3.6' P.C. +03.5 0.0'+07.6TEMPLEDR.ENTRY TOBRIDGES II2222 FF File Name: \\ucs04fs\road\roadteam3\C3D\16-404\Road\Dwg\Plans\Plan & Profile.dwg Plot Date: 2/27/2017 Plotted By: Nimz, John1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKHEKJNII WRC WRC 1" = 20' 1" = 5" - - - - 39 200 16-ENG-52 PLAN & PROFILE LINE "PR-A" CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN See Plat No. 1 sheets for Right Of Way information. Line "PR-A" to be constructed. All proposed construction station/offsets are described from Line "PR-A" unless otherwise noted. LEGEND HMA for Approaches 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" Placed w/ Minimum Of 3 Lifts, on Multi-Use Path 110 #/Sys HMA Surface, Type "A" on 330 #/Sys HMA Intermediate, Type "A" on 5" Compacted Aggregate, No. 53, Base Truck Apron Decorative PCCP, 7" 165 #/Sys HMA Surface, Type "C" on 275 #/Sys HMA Intermediate, Type "C" on 385 #/Sys HMA Base, Type "C" on 250 #/Sys HMA Intermediate, OG, Type "C" on 330 #/Sys HMA Base, Type "C" Milling, Asphalt, 1 12" 165 #/Sys HMA Surface, Type "C" Curb & Gutter, Type II Curb & Gutter, Type III Roll Curb Concrete Center Curb, Type D Nursery Sodding D1 F1 F K K1 17 22 26 15 16 RPCCP for Approaches, 9" on Subgrade Treatment, Type II C3 PCCP for Approaches, 6" on Subgrade Treatment, Type II C1 M Integral Barrier Curb18 Curb Ramp, ConcreteCR Sidewalk, 4" on 4" Compacted Aggregate, No. 53, Base HMA for Widening 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" W Revised Plan & Profile1 1 Subgrade Treatment, Type IB Placed w/ Minimum Of 3 Lifts, on Subgrade Treatment, Type IB 1 Matchline - Sta. 150+00 "PR-A"Matchline - Sta. 143+75 "PR-A"Revised Plan & Profile3 Revised Storm Structures3 840 845 850 855 860 865 870 840 845 850 855 860 865 870 858.58858.6858.91858.9859.19859.2859.33859.3859.43859.4859.19859.2858.70858.7858.31858.3857.92857.9857.55857.5857.48857.5857.37857.4857.34857.3161+00 162+00 163+00 164+00 165+00 166+00 -0.85% PVI STA. = 161+95.00 PVI ELEV. = 860.15 V.C. = 350' PVI STA. = 166+00.00 PVI ELEV. = 856.72 V.C. = 305' -0.85% PVI STA. = 161+95.00 PVI ELEV. = 860.15 V.C. = 350' PVI STA. = 166+00.00 PVI ELEV. = 856.72 V.C. = 305' Existing Ground Profile Grade 207 210 213459+09 17.1, TELE. PED.459+09.3 18.6, EDGE OF WOODS459+10.6 23.5, POWER POLE459+16.3 22.6, POWER POLE459+18.7 17.6, TELE. PED.456+10.4 63.5, EDGE OF WOODS456+81.6 24.5, POWER POLE457+99 35.9, SAN. M.H. /BURIED458+49.4 77.9, EDGE OF WOODS459+26 24.4, POWER POLE459+09.1 25.1, GUY ANCHOR 459+27.8 62.3, ELEC. PED.459+41.2 19.7, FIRE HYD. 459+74.1 59.7, IPL ELEC. PED.461+16 29.6, SAN. M.H. 461+80.2 26.1, POWER POLE(grass) (grass)(grass) (grass) (grass)(grass) (field) (field) (field) (grass)(grass)(grass) (asph.) (asph.) (asph.) (asph.) (asph.)(asph.) 18" PVC 18" PVC161+00162+00163+00164+00165+00166+00SPRING MILL ROAD Line "PR-A" Line "A" & Section Line Section 35, T18N, R3E Clay Township Hamilton County, IN Section 34, T18N, R3E Clay Township Hamilton County, IN App. P.L. & Exist. R/W App. P.L. & Exist. R/WApp. P.L. & Exist. R/WApp. P.L. & Exist. R/W (field) K K 26 15 16 15 16 14.0'14.0'5.5'7.0'5.5' K K 26 15 16 15 16 26 5.5'7.0'5.5'+00.09.7'F1 26 207 210 206 215 214 209 208 212 211459+66.9 25.9,GATE459+57.1 33.3,WATER METER459+47.5 36,WATER VALVE459+46.9 34.4,EDGE OF WOODS459+42.6 24.7,GATE459+37.5 24.3,POWER POLE459+37 21.2,TELE. PED.459+36.6 24.9,WEIHE REBARFOUND459+25.4 27.3,GUY ANCHOR459+25 32.4,GUY ANCHOR459+24.4 49.5,POWER POLE(wetlands) Note: Do Not Disturb Wetlands Outside Of Construction Limits Const. LimitsConst. Limits Const. Limits Const. Limits Const. Limits Const. Limits R/W R/W R/W 26 26 R/W R/W 161+00 162+00 163+00 164+00 165+00 166+0026 213 +43.55.5' 1.5'18.0'19.5'+50.426 15 16 15 16 22 +25.514.0'+73.414.0'+43.524.0'+50.429.5'8.0'8.0' 5.5' 1.5' 22 +43.518.0'+43.524.0'App. P.L. & Exist. R/WK 14.0'F1 206A +26.4 54.5' R= 25.0' +50.4 54.6' R= 25.0' +88, Street Appr. W= 34.7' D1+33.426 CR CR File Name: \\ucs04fs\road\roadteam3\C3D\16-404\Road\Dwg\Plans\Plan & Profile.dwg Plot Date: 2/27/2017 Plotted By: Nimz, John1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKHEKJNII WRC WRC 1" = 20' 1" = 5" - - - - 42 200 16-ENG-52 PLAN & PROFILE LINE "PR-A" CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN See Plat No. 1 sheets for Right Of Way information. Line "PR-A" to be constructed. All proposed construction station/offsets are described from Line "PR-A" unless otherwise noted. LEGEND HMA for Approaches 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" Placed w/ Minimum Of 3 Lifts, on Multi-Use Path 110 #/Sys HMA Surface, Type "A" on 330 #/Sys HMA Intermediate, Type "A" on 5" Compacted Aggregate, No. 53, Base Truck Apron Decorative PCCP, 7" 165 #/Sys HMA Surface, Type "C" on 275 #/Sys HMA Intermediate, Type "C" on 385 #/Sys HMA Base, Type "C" on 250 #/Sys HMA Intermediate, OG, Type "C" on 330 #/Sys HMA Base, Type "C" Milling, Asphalt, 1 12" 165 #/Sys HMA Surface, Type "C" Curb & Gutter, Type II Curb & Gutter, Type III Roll Curb Concrete Center Curb, Type D Nursery Sodding D1 F1 F K K1 17 22 26 15 16 RPCCP for Approaches, 9" on Subgrade Treatment, Type II C3 PCCP for Approaches, 6" on Subgrade Treatment, Type II C1 M Integral Barrier Curb18 Curb Ramp, ConcreteCR Sidewalk, 4" on 4" Compacted Aggregate, No. 53, Base HMA for Widening 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" W Revised Plan & Profile1 1 Subgrade Treatment, Type IB Placed w/ Minimum Of 3 Lifts, on Subgrade Treatment, Type IB 1 Matchline - Sta. 167+00 "PR-A"Matchline - Sta. 160+75 "PR-A"1 1 Revised Plan & Profile3 Moved Str. No. 1073 Added Street Approach31 840 845 850 855 860 865 870 840 845 850 855 860 865 870 859.13859.1858.59858.6858.23858.2858.00858.0857.96858.0858.00858.0858.06858.1858.15858.1858.30858.3858.39858.4858.40858.4858.50858.5858.81858.8174+00 175+00 176+00 177+00 178+00 179+00 PVI STA. = 175+25.00 PVI ELEV. = 857.10 V.C. = 350' -0.95%+0.60% PVI STA. = 175+25.00 PVI ELEV. = 857.10 V.C. = 350' Existing Ground Profile Grade 240A238 234 231226223 473+08.7 25.6, WATER VALVE473+08.2 25.5, GAS VALVE473+20.7 38.6, SIGN /STOP473+35 54.4, CURB INLET473+23.9 68, FIRE HYDRANT473+25.5 68.1, WATER VALVE473+79.7 55.6, CURB INLET473+80.9 52.2, CURB INLET474+31.3 185.8, BEEHIVE INLET474+02.5 138, SAN. M.H.474+10.3 33.4, CLEAN OUT468+77.5 23.3, TELE. PED. 468+80.9 26.1, POWER POLE468+83.9 13.8, SPEED LIMIT SIGN469+32.6 14, WATER VALVE 470+12 35.7, SAN. M.H. 470+11.8 64, ELEC. PED. 471+30.6 25.8, POWER POLE473+27.1 15.1, WATER VALVE 473+65.7 40.4, 10" DEC. TREE 474+05.4 33.7, SAN. M.H. 12" RCP21" RCP21" RCP 15" CPP 21" RCP 21" RCP12" CMP (grass) (grass) (grass) (grass) (grass) (grass) (grass) (grass)(grass) (woods)(woods) (asph.) (asph.) (asph.) (asph.) (asph.) (asph.) (ls.) 18" PVC 18" PVC 10" PVC5' N.A.E.174+00175+00176+00177+00178+00179+00SPRING MILL ROAD Line "A" & Section Line Line "PR-A" Section 35, T18N, R3E Clay Township Hamilton County, IN Section 34, T18N, R3E Clay Township Hamilton County, IN A p p . P . L . & E x i s t . R /WApp. P.L. & Exist. R/ W App. P.L. & Exist. R/W App. P.L. & Exist. R/WApp. P.L. & Exist. R/W (grass) App. P.L. & Exist. R/W App. P.L. & Exist. R/W VARIABLED. & U.E.20' TRAIL & S.S.E..20' P.A.E..5' NON ACCESS ESMT. 20' D. & U. E. (ls.) (grass) 18" PVC14.0'5.5'+36.6+06.619.5'5.5'+14.614.0'5.5'+89.614.0'5.5' K K 26 15 16 15 16 F126 +06.6 54.5' R= 25.0' +14.6 54.6' R= 25.0' 5.5' 1.5' 22 5.0' Typ. 8.0' Typ. 5.0' 8.0'+64.329.5'+14.618.0'+06.65.5' 1.5'24.0'22 26 15 15 16 16 K F1 F1 F1 F1 D1 K 241225 243242 239 240 228 227 236 235 229 230 233 232 470+29.4 84.4,EDGE OF WOODS468+48.7 13.9,MAILBOX468+52.6 47.3,2' LIGHT BASE470+63.9 34.5,12" RCP W/END SECTION470+64.1 98.7,12" RCP470+10.2 81.3,TELE. PED. /AT&T 470+10.1 74.2,TELE. PED. /AT&T469+99.1 25.6,PLASTIC FENCE469+90.4 72.1,FIRE HYDRANT469+19.6 23.8,CABLE TV PED.469+16.1 36.8,30" DEC. TREE469+05.1 22,PLASTIC FENCE468+96 20.3,12" CMP468+39.2 25.8,TELE. PED.468+40.3 25.4,PLASTIC FENCE468+48.1 19.8,12" CMP468+89.1 51,LIGHT POLE468+86.9 41.6,PLASTIC FENCE468+55.6 42.1,PLASTIC FENCE468+54.7 81.1,PLASTIC FENCE471+17.1 52.3,BEEHIVE INLET471+17.2 107.9,INLET472+08 41,SAN. M.H.CR CR5.0' 8.0'14.0'+07.6+61, Street Appr. W= 42.0' R/WR/W R/W R/W R/W 174+00 175+00 176+00 177+00 178+00 179+00 224 240A 237 JACKSONSGRANT BVLD.226 223 231 234 238 240A Cap Pipe 5.5'14.0'File Name: \\ucs04fs\road\roadteam3\C3D\16-404\Road\Dwg\Plans\Plan & Profile.dwg Plot Date: 2/27/2017 Plotted By: Nimz, John1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKHEKJNII WRC WRC 1" = 20' 1" = 5" - - - - 44 200 16-ENG-52 PLAN & PROFILE LINE "PR-A" CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN See Plat No. 1 sheets for Right Of Way information. Line "PR-A" to be constructed. All proposed construction station/offsets are described from Line "PR-A" unless otherwise noted. LEGEND HMA for Approaches 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" Placed w/ Minimum Of 3 Lifts, on Multi-Use Path 110 #/Sys HMA Surface, Type "A" on 330 #/Sys HMA Intermediate, Type "A" on 5" Compacted Aggregate, No. 53, Base Truck Apron Decorative PCCP, 7" 165 #/Sys HMA Surface, Type "C" on 275 #/Sys HMA Intermediate, Type "C" on 385 #/Sys HMA Base, Type "C" on 250 #/Sys HMA Intermediate, OG, Type "C" on 330 #/Sys HMA Base, Type "C" Milling, Asphalt, 1 12" 165 #/Sys HMA Surface, Type "C" Curb & Gutter, Type II Curb & Gutter, Type III Roll Curb Concrete Center Curb, Type D Nursery Sodding D1 F1 F K K1 17 22 26 15 16 RPCCP for Approaches, 9" on Subgrade Treatment, Type II C3 PCCP for Approaches, 6" on Subgrade Treatment, Type II C1 M Integral Barrier Curb18 Curb Ramp, ConcreteCR Sidewalk, 4" on 4" Compacted Aggregate, No. 53, Base HMA for Widening 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" W Revised Plan & Profile1 1 Subgrade Treatment, Type IB Placed w/ Minimum Of 3 Lifts, on Subgrade Treatment, Type IB 1 Matchline - Sta. 175+50 "PR-A"Matchline - Sta. 173+25 "PR-A"Revised Plan & Profile3 Proposed Median Break & Drive Deleted3 835 840 845 850 855 860 865 835 840 845 850 855 860 865 859.80859.8859.91859.9859.93859.9859.93859.9860.13860.1860.40860.4860.62860.6860.56860.6860.05860.0859.41859.4858.57858.6857.15857.2855.32855.3186+00 187+00 188+00 189+00 190+00 191+00 -3.71% +0.36% PVI STA. = 189+50.00 PVI ELEV. = 861.00 V.C. = 305' PVI STA. = 185+00.00 PVI ELEV. = 859.38 V.C. = 250' -3.71% +0.36% PVI STA. = 189+50.00 PVI ELEV. = 861.00 V.C. = 305' PVI STA. = 185+00.00 PVI ELEV. = 859.38 V.C. = 250'Existing Ground Profile Grade 272 12" Pipes. See Outfall Structure Details 268 261258255 267482+62.2 24.7, PLASTIC FENCE483+30.8 23.2, CABLE TV PED.485+49.6 36.2, FORCEMAIN SAN. MARKER POST485+50.4 25.1, PLASTIC FENCE481+13.8 22.1, FIRE HYD. 481+13.7 47, POWER POLE 481+10.3 48.4, POWER POLE481+53.3 27.6, SAN. M.H. 482+86.9 37.3, BEEHIVE INLET 483+00.5 55.3, BUSH 482+86.6 63.6, BEEHIVE INLET 484+11.4 232.7, MAG NAIL FOUND 482+91.7 53.9, TREE ROW483+50.5 56, BUSH 483+38.2 53, BUSH 483+25.8 54.1, BUSH 483+12.1 52.1, BUSH 483+58.5 49.3, POWER POLE483+56.3 47.2, POWER POLE 484+07.3 68.4, SIGN 484+04.2 41, CURB INLET485+25.1 31.7, SAN. M.H. 485+43.5 52.6, TREE ROW485+52.4 47.6, SAN. M.H. 485+55.1 32.3, SAN. M.H. 485+68.4 40.6, BEEHIVE INLET 485+70.5 47.8, TELE. PED. 485+72.8 46.3, POWER POLE 485+66.3 47.7, POWER POLE485+59.7 44.6, EDGE OF WOODS485+89 79.5, EDGE OF WOODS485+79.4 29.1, WOOD RAIL FENCE486+17.2 23.8, CABLE TV PED. 486+20.4 24.1, TELE. PED. 12" RCP12" RCP 12" RCPPINTAIL CT.(grass) (grass) (grass) (grass) (grass) (grass) (grass) (grass)(grass)(grass) (grass) (grass) (asph.) (asph.) (asph.) (conc)(conc) (con c ) (woods) (woods)(ls) 18" PVC 18" PVC 8" PVC8" PVC 8" PVC15' D. & U. E.15' D. & U. E.15' D., U. & S. S. E.185+00186+00187+00188+00189+00190+00191+00SPRING MILL ROAD Line "A" & Section Line Line "PR-A"483+68.6 65.7, WROUGHTIRON FENCE483+83.5 65.7,WROUGHTIRON FENCE482+89.1 66.7, WROUGHTIRON FENCE481+94 68.5,WROUGHT IRON FENCE481+92.2 66.5,WROUGHT IRON FENCE480+80.5 66.7, WROUGHTIRON FENCE482+33.3 24.2,SIGN /WARNING(conc )484+66.6 65,BRICK COLUMN484+71 67.7,WROUGHTIRON FENCE484+81.5 67.5,WROUGHTIRON FENCE484+85.3 64.9,BRICK COLUMN484+86.1 61,TREE ROW484+79.2 77.5,SAN. M.H.25' BRIDALPATH D. & U. E.30' BRIDAL PATH ESMT. 15' U.E. SIGN ESMT. VARIABL E D . & U . & S . S . E . L.M.E. Section 35, T18N, R3E Clay Township Hamilton County, IN Section 34, T18N, R3E Clay Township Hamilton County, IN App. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W480+75.7 51.5,COMMERCIAL SIGN24.0'5.5'+85.229.8'+71.119.5'+74.3+85.2 60.5' R= 31.0' +74.3 61.7' R= 32.0'(ls)483+83.7 64.2,BRICK COLUMN483+68.7 63.9,BRICK COLUMNK K 26 15 16 15 16 F126 14.0'14.0'5.5'7.0'5.5' 5.0' Typ. 8.0' Typ.14.0'5.5'+55.25.5'+85.224.0'+85.21.5'18.0'22 19.5'+99.414.0'5.5'+85.2K 15 15 F126 5.0' 8.0' K K 26 15 16 15 16 26 486+12.6 23.8,TELE. PED.486+16.4 23.3,CABLE TV PED.D1 +29, Street Appr. W= 26.0'484+43.367.7, SIGN484+45.6 43.5,CURB INLETR/W R/W R/W 186+00 187+00 188+00 189+00 190+00 191+00 263 262 260 259 257 256 272 269 270264265266 271 268 267 261258255 File Name: \\ucs04fs\road\roadteam3\C3D\16-404\Road\Dwg\Plans\Plan & Profile.dwg Plot Date: 2/27/2017 Plotted By: Nimz, John1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKHEKJNII WRC WRC 1" = 20' 1" = 5" - - - - 46 200 16-ENG-52 PLAN & PROFILE LINE "PR-A" CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN See Plat No. 1 sheets for Right Of Way information. Line "PR-A" to be constructed. All proposed construction station/offsets are described from Line "PR-A" unless otherwise noted. LEGEND HMA for Approaches 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" Placed w/ Minimum Of 3 Lifts, on Multi-Use Path 110 #/Sys HMA Surface, Type "A" on 330 #/Sys HMA Intermediate, Type "A" on 5" Compacted Aggregate, No. 53, Base Truck Apron Decorative PCCP, 7" 165 #/Sys HMA Surface, Type "C" on 275 #/Sys HMA Intermediate, Type "C" on 385 #/Sys HMA Base, Type "C" on 250 #/Sys HMA Intermediate, OG, Type "C" on 330 #/Sys HMA Base, Type "C" Milling, Asphalt, 1 12" 165 #/Sys HMA Surface, Type "C" Curb & Gutter, Type II Curb & Gutter, Type III Roll Curb Concrete Center Curb, Type D Nursery Sodding D1 F1 F K K1 17 22 26 15 16 RPCCP for Approaches, 9" on Subgrade Treatment, Type II C3 PCCP for Approaches, 6" on Subgrade Treatment, Type II C1 M Integral Barrier Curb18 Curb Ramp, ConcreteCR Sidewalk, 4" on 4" Compacted Aggregate, No. 53, Base HMA for Widening 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" W Revised Plan & Profile1 1 Subgrade Treatment, Type IB Placed w/ Minimum Of 3 Lifts, on Subgrade Treatment, Type IB 1 Matchline - Sta. 191+25 "PR-A"Matchline - Sta. 185+00 "PR-A"Added Pedestrian Crossing, See Details Sheet 8-A3 Revised Plan & Profile3 Moved Str. No. 270 3 IIIIIIIIIIIIIII I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I IIII I I IIIIIIIIIIIIIII I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I IIII I I 835 840 845 850 855 860 865 835 840 845 850 855 860 865 849.46849.5850.32850.3851.70851.7852.41852.4853.42853.4854.51854.5855.21855.2855.44855.4855.48855.5855.30855.3854.99855.0854.71854.7854.75854.8198+00 199+00 200+00 201+00 202+00 203+00 +2.25% -0.50% PVI STA. = 200+50.00 PVI ELEV. = 856.00 V.C. = 350' PVI STA. = 203+50.00 PVI ELEV. = 854.50 V.C. = 200' +2.25% -0.50% PVI STA. = 200+50.00 PVI ELEV. = 856.00 V.C. = 350' PVI STA. = 203+50.00 PVI ELEV. = 854.50 V.C. = 200' Existing Ground Profile Grade 298B 295 292 299A 299C299B 12" Pipes. See Outfall Structure Details496+91.3 20.6, FIRE HYD. 493+55.9 38.4, EDGE OF WOODS493+75.7 46.2, POWER POLE493+76.9 31.9, GUY ANCHOR493+78.6 25.4, WOVEN WIRE FENCE493+93.3 25.7, WOVEN WIRE FENCE493+93.3 25.2, CRIPE CAPPED REBAR FOUND494+22.6 25, WOVEN WIRE FENCE494+43.3 14.8, GAS MARKER POST494+51.1 18.2, EDGE OF WOODS495+04.5 25.8, 8" DEC. TREE495+07.5 25.5, C.L.T.F.495+51.8 40.8, 24" DEC. TREE495+66.8 53.2, 24" DEC. TREE495+55.8 68.9, 24" DEC. TREE495+57.8 47.4, POWER POLE495+77 61.3, BUILDING496+06.7 60.1, BUILDING496+16.6 21.9, 24" DEC. TREE496+15.8 25.4, 16" DEC. TREE496+13.7 27.2, 16" DEC. TREE496+21.5 17.2, CABLE TV PED.496+57.2 45.7, 16" DEC. TREE496+54.5 46.5, 16" DEC. TREE496+56.4 65.1, 24" DEC. TREE496+85.1 29, 20" DEC. TREE496+85.9 68.9, 20" DEC. TREE497+20.9 25.6, 20" DEC. TREE497+57.9 23.6, 16" DEC. TREE498+03.1 64.3, 24" DEC. TREE497+93.5 66.8, 24" DEC. TREE498+00.5 19.3, RISER POLE498+14.2 45, 12" DEC. TREE498+05.7 27.3, 18" DEC. TREE498+17 32.9, EDGE OF WOODS498+51.7 59.9, EDGE OF WOODS493+38.3 38.5, FORCE MAIN MARKER POST493+83.4 47.5, POWER POLE493+83.6 63.7, GUY ANCHOR 495+33.5 73.7, EDGE OF WOODS495+82.8 48.2, POWER POLE495+87.9 47.8, POWER POLE496+04.5 16.6, MAILBOX 496+07.3 16.3, MAILBOX 496+38.2 36.9, M.H.496+38.8 15.4, MAILBOX 497+06.4 16.2, MAILBOX 497+22 43.7, WELL (grass)497+84.7 26.6, 12" CMP498+17.1 26.5, 12" CMP498+13.7 39.3, EDGE OF WOODS 498+67.4 16.9, WATER VALVE 497+67.4 46.8, POWER POLE497+71.5 47.4, POWER POLE12" CMP (grass)(grass) (gravel) (grass) (grass) (grass) (grass)(grass) (field) (asph.) (asph.) (asph.) (gravel) (asph.) (conc.) (asph.) (woods) (woods) (woods) (woods) (woods) (woods) (landscaping)7.5' U. E.7.5' U. E.198+00199+00200+00201+00202+00203+00SPRING MILL ROAD Line "A" & Section Line Line "PR-A" Section 35, T18N, R3E Clay Township Hamilton County, IN Section 34, T18N, R3E Clay Township Hamilton County, IN App. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W BRIDAL PATH D. & U. E. K K 26 15 16 15 16 26 14.0'14.0'5.5'7.0'5.5' 5.0' Typ. 8.0' Typ.F1 24.0'5.5'+16.85.5'+46.814.0'1.5'28.0'22+11.15.5' 1.5' 22+81.114.0'+81.128.0'+46.829.5'+32.914.0'+32.914.0'+03.05.5' 1.5'+21.0K K K 5.5'14.0'22 +73.414.0'+06.85.5' 22 5.5' 1.5'+10.929.5'5.5'+36.8298B 298A 298 295 297 296 292 294 293 +56.1, Class I Drive W= 14.0' C1C1C1 +76.8, Class I Drive W= 32.0' +07.1, Class I Drive W= 15.5' C1 +29.5, Class I Drive W= 13.3' C1 15 26 15 16 15 16 26 F1 F F (grass) FFF 26 16 15 498+53.8 18.7,FORCE MAIN MARKER POST16 R/W R/W R/W 299 299A 198+00 199+00 200+00 201+00 203+00 22 299B 299C File Name: \\ucs04fs\road\roadteam3\C3D\16-404\Road\Dwg\Plans\Plan & Profile.dwg Plot Date: 2/27/2017 Plotted By: Nimz, John1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKHEKJNII WRC WRC 1" = 20' 1" = 5" - - - - 48 200 16-ENG-52 PLAN & PROFILE LINE "PR-A" CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN See Plat No. 1 sheets for Right Of Way information. Line "PR-A" to be constructed. All proposed construction station/offsets are described from Line "PR-A" unless otherwise noted. LEGEND HMA for Approaches 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" Placed w/ Minimum Of 3 Lifts, on Multi-Use Path 110 #/Sys HMA Surface, Type "A" on 330 #/Sys HMA Intermediate, Type "A" on 5" Compacted Aggregate, No. 53, Base Truck Apron Decorative PCCP, 7" 165 #/Sys HMA Surface, Type "C" on 275 #/Sys HMA Intermediate, Type "C" on 385 #/Sys HMA Base, Type "C" on 250 #/Sys HMA Intermediate, OG, Type "C" on 330 #/Sys HMA Base, Type "C" Milling, Asphalt, 1 12" 165 #/Sys HMA Surface, Type "C" Curb & Gutter, Type II Curb & Gutter, Type III Roll Curb Concrete Center Curb, Type D Nursery Sodding D1 F1 F K K1 17 22 26 15 16 RPCCP for Approaches, 9" on Subgrade Treatment, Type II C3 PCCP for Approaches, 6" on Subgrade Treatment, Type II C1 M Integral Barrier Curb18 Curb Ramp, ConcreteCR Sidewalk, 4" on 4" Compacted Aggregate, No. 53, Base HMA for Widening 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" W Revised Plan & Profile1 1 Subgrade Treatment, Type IB Placed w/ Minimum Of 3 Lifts, on Subgrade Treatment, Type IB 1 Matchline - Sta. 203+75 "PR-A"Matchline - Sta. 197+50 "PR-A"Revised Storm Structures3 Revised Plan & Profile3 840 845 850 855 860 865 870 840 845 850 855 860 865 870 855.14855.1855.39855.4855.58855.6855.64855.6855.76855.8855.94855.9856.22856.2856.61856.6856.81856.8857.22857.2857.73857.7858.32858.3858.96859.0204+00 205+00 206+00 207+00 208+00 209+00 +0.67% +0.30% PVI STA. = 205+85.00 PVI ELEV. = 856.07 V.C. = 200' PVI STA. = 208+75.00 PVI ELEV. = 856.93 V.C. = 350' +0.67% +0.30% PVI STA. = 205+85.00 PVI ELEV. = 856.07 V.C. = 200' PVI STA. = 208+75.00 PVI ELEV. = 856.93 V.C. = 350' Existing Ground Profile Grade 300 301 302 306 308 299D-SQU 304A304 303A-SQU 12" Pipes. See Outfall Structure DetailsSteel-Backed Timber Railing Steel-Backed Timber Railing Steel-Backed Timber Railing +09.24+39.24+59.24+26.80+46.80+76.80+65.17+95.17+65.17+32.87+32.87+49.73Bridge No. 31 Steel-Backed Timber Railing Terminal Section Type SBT-FAT Terminal Section Type SBT-FAT Terminal Section Type SBT-FAT Steel-Backed Timber Railing Circular CurveIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIII I I I I I I I I IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIII I I I I I I I I I499+21.2 51.3, 6" DEC. TREE499+18.6 47.3, 12" CMP499+13 36.2, 15" CMP499+49.2 48.4, 12" CMP499+53.8 36.9, 15" CMP499+61.3 18.6, EDGE GRAVEL500+44 31.8, 24" DEC. TREE500+66.1 27, EDGE OF WOODS500+95.5 52.7, EDGE OF WOODS501+41.7 50, RW MON FOUND501+42.3 70.7, RW MON FOUND501+83.5 47.9, POWER POLE501+83.2 41.7, GUY ANCHOR502+17.2 42, 8" CON. TREE502+16.4 50.8, RW MON FOUND502+22.7 59.5, SAN. CLEAN OUT502+25.8 71.5, 10' C.L.T.F.502+26.8 72, C.L.T.F.502+40.7 27.4, 15" CMP502+78.5 40.6, C.L.T.F.502+83.5 37.3, 4" CON. TREE502+79.9 51.1, GAS METER503+14.2 25.6, SAN. M.H.503+06.9 32.6, EDGE OF WOODS502+88.7 28.2, 15" CMP503+21.1 78.9, WOOD FENCE504+89.4 67.2, WOOD FENCE502+15.4 45.3, CABLE TV PED.502+22.4 46.8, POWER POLE498+88.6 49.7, RW MON FOUND 499+00.8 15.9, DELINEATOR 499+12.7 16, MAILBOX 499+91.5 49.4, RW MON FOUND 500+03.9 47.1, POWER POLE500+90.1 63.6, EDGE OF WOODS501+64.9 35.9, WATER METER 501+70.7 17.3, DELINEATOR 501+86.3 32.7, 15" RCP502+00 57.1, EDGE OF WOODS502+33.5 29.9, INLET 502+24.3 51.8, TELE. PED. 502+47.5 78.9, INLET 502+56.2 58.9, SAN. M.H. 502+51.4 46.9, POWER POLE502+52.7 46.5, TBM #102 502+59.2 48.1, POWER POLE 502+65.5 47.2, TELE. PED. 502+59.2 41.8, EDGE OF WOODS END 502+28.1 16.5, FIRE HYD. 502+28.9 15.2, WATER VALVE 502+32.2 16.7, MAILBOX 502+16.9 0, HARRISON MON. FOUND 500+63.5 60.7, EDGE OF WOODS502+13.4 49.8, SPEAKER BOX502+28 46.5, WOOD FENCE502+17.1 49.9, RW MON. FOUND 502+77.2 76.5, EDGE OF WOODS 504+53.9 48.4, POWER POLE504+57.8 47.8, GUY POLE 504+64.9 79.9, BEEHIVE INLET 12" RCP15" RCP 12" RCP 15" CMP 15" CMP 12" CMP (grass) (grass) (grass) (grass)(grass) (grass) (grass) (grass) (grass) (grass) (grass) (grass) (grass) (wetlands) (grass) (asph.) (gravel) (asph.) (asph.) (asph.) (asph.) (conc)(conc) (woods) (woods) (woods)(woods) (woods) (woods) (woods) (woods) 15" P V C 15" PVC 10" PVC8" PVC 8" PVC10' U.E.Z204+00205+00206+00207+00208+00209+00SPRING MILL ROAD Line "A" & Section Line Line "PR-A"500+08.9 46.3, OUT OFSERVICE POWER POLE10' U.E.5' NON ACCESS ESMT. 15' DRAIN. & LANDSCAPE ESMT. 20' SEWER & UTILTY ESMT. 25' DRAIN. & LANDSCAPE ESMT. 10' D. & U.E. 25' L.E. 2' NON-ACCESS ESMT.BRIDAL PATH, D. & U. E.Section 35, T18N, R3E Clay Township Hamilton County, IN Section 34, T18N, R3E Clay Township Hamilton County, IN App. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W App. P.L. & Exist. R/W K K 26 15 16 15 16 F126 14.0'5.5' 22 +21.75.5'+21.714.0'26 26 311 310 312 308 307 309 306 305303 302301 300 304 C1 +38.7, Class I Drive W= 15.5' C1 +10, Class II Drive W= 13.6' +68, Class I Drive W= 29.3' K 15 15 15 15 KK 15 F1 R/W 204+00 205+00 206+00 207+00 208+00 209+00 303A-SQU 304A 299D-SQU 26 26 26 26 262.0 Tons Of Revetment Riprap & 5.1 Sys Of Geotextiles Req'd.4.0 Tons Of Revetment Riprap & 9.1 Sys Of Geotextiles Req'd. Bridge No. 31 File Name: \\ucs04fs\road\roadteam3\C3D\16-404\Road\Dwg\Plans\Plan & Profile.dwg Plot Date: 2/27/2017 Plotted By: Nimz, John1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKHEKJNII WRC WRC 1" = 20' 1" = 5" - - - - 49 200 16-ENG-52 PLAN & PROFILE LINE "PR-A" CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN See Plat No. 1 sheets for Right Of Way information. Line "PR-A" to be constructed. All proposed construction station/offsets are described from Line "PR-A" unless otherwise noted. LEGEND HMA for Approaches 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" Placed w/ Minimum Of 3 Lifts, on Multi-Use Path 110 #/Sys HMA Surface, Type "A" on 330 #/Sys HMA Intermediate, Type "A" on 5" Compacted Aggregate, No. 53, Base Truck Apron Decorative PCCP, 7" 165 #/Sys HMA Surface, Type "C" on 275 #/Sys HMA Intermediate, Type "C" on 385 #/Sys HMA Base, Type "C" on 250 #/Sys HMA Intermediate, OG, Type "C" on 330 #/Sys HMA Base, Type "C" Milling, Asphalt, 1 12" 165 #/Sys HMA Surface, Type "C" Curb & Gutter, Type II Curb & Gutter, Type III Roll Curb Concrete Center Curb, Type D Nursery Sodding D1 F1 F K K1 17 22 26 15 16 RPCCP for Approaches, 9" on Subgrade Treatment, Type II C3 PCCP for Approaches, 6" on Subgrade Treatment, Type II C1 M Integral Barrier Curb18 Curb Ramp, ConcreteCR Sidewalk, 4" on 4" Compacted Aggregate, No. 53, Base HMA for Widening 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" W Revised Plan & Profile1 1 Subgrade Treatment, Type IB Placed w/ Minimum Of 3 Lifts, on Subgrade Treatment, Type IB 1 Matchline - Sta. 210+00 "PR-A"Matchline - Sta. 203+75 "PR-A"1 1 Revised Storm Structures3 Revised Plan & Profile3 825 830 835 840 845 850 855 825 830 835 840 845 850 855 847.02847.0845.67845.7844.24844.2843.04843.0842.22842.2841.61841.6841.08841.1840.76840.8840.75840.8840.76840.849+00 50+00 51+00 52+00 53+00 54+00 -0.35% -1.50% -2.65% PVI STA. = 51+40.00 PVI ELEV. = 846.39 V.C. = 125' PVI STA. = 53+40.00 PVI ELEV. = 841.10 V.C. = 145' -0.35% -1.50% -2.65% PVI STA. = 53+40.00 PVI ELEV. = 841.10 V.C. = 145' Existing Ground Profile Grade Begin Profile Sta. 51+20.97 "PR-S-1-A" Elev. 846.59 See Roundabout Grading Details 107 172 173 174 175-SQU -0.30% +00 838.01 +20 837.35 -0.30% Proposed Ditch Grade Rt. 12" Pipes. See Outfall Structure Details IIIIIIIIIIIII51+00 52+00 53+00 54+00 55+0014+77.7 52.8, ELEC. METER423+77.2 122.8, "A" 8" CON. TREE423+76.6 150, "A" 8" DEC. TREE423+79.6 170.6, "A" 4" DEC. TREE423+71.6 163.5, "A" 6" CON. TREE423+70.6 176.3, "A" 6" CON. TREE423+95.2 178.3, "A" GAS MARKER POST423+88.2 157.6, "A" GAS VALVE12+15.2 66.8, 8" DEC. TREE12+49.5 61.8, 6" CON. TREE12+83.6 62.6, 6" CON. TREE13+12.9 61.4, 6" DEC. TREE13+38.4 60.5, 6" CON. TREE13+61.3 62.2, 6" CON. TREE13+95.3 62, 8" DEC. TREE12+24.2 17.7, POWER POLE14+13.4 17.6, POWER POLE14+43.9 15.7, ELLIPTICAL CMP14+81.1 52.3, GUARD RAIL14+95.9 18.5, POWER POLE14+53.4 35.4, 16" DEC. TREE 14+57.6 37.5, 16" DEC. TREE 14+65.5 34.7, 16" DEC. TREE 14+43.9 17.6, 3.25' X 1.58' CMP 14+98.2 48.8, EDGE OF WOODS15+00 (woods)(grass)(asph.) (asph.)(gravel)(grass)(grass) (grass) (woods) (woods)12" RCPELLIPTICAL CMP(grass) (grass)(gravel)(gravel)(gravel) (grass) (grass) 111TH ST. 18" PVC50+0051+0052+0053+0054+00Line "PR S-1-A"Line "PR-A"15' SIGHT DISTANCE AND UTIL. ESMT.(grass)(woods)(woods)(woods)Line "A" & Section LineSPRING MILL ROADApp. P.L. & Exist. R/WApp. P.L. & Exist. R/W App. P.L. & Exist. R/WSection 4, T17N, R3E Clay Township Hamilton County, IN Section 3, T17N, R3E Clay Township Hamilton County, IN Line "S-1-A" & 1/4 Section Line Refer To Roundabout Geometric Details Sheet For Alignments Of Curb/ Pavement EdgesCRCR CR5.0' Typ.8.0' Typ.16 15 K 15 K 16 15 F1 F1 F1 15 18 17 18 17 F2 F2 K F1 26 26 26 26 +08.4 +01.2 +98.0 +00.1 CR CR 5.0' Typ.8.0' Typ. 5. 0 ' T y p . 8. 0 ' T y p . K 16 15 K 16 26 16 15 26 26 26 26 26 26 15 15 K K K K 26 App. P.L. & Exist. R/W End Construction P.O.T. 53+64.06 "PR S-1-A" App. P.L. & Exist. R/W App. P.L. & Exist. R/W 13+20.9 47.8,EDGE OF WOODS12+73.1 48.5,EDGE OF WOODS12+58.8 18.2,POWER POLEApp. P.L. & Exist. R/W RM W End Incidental Construction P.O.T. 54+25.00 "PR S-1-A" 8.0' T y p. 2' Min.R/WR/WR/W30' LIMITED DRAIN. ESMT. DUKE ENERGY ESMT.DUKE ENERGY ESMT. Curb Turnout & Conc. Gutter. See Standard Drawings E 605-CTCG-01 & E 605-CTCG-01 +00.0+00.09.0'9.0'Curb Turnout & Conc. Gutter. See Standard Drawings E 605-CTCG-01 & E 605-CTCG-01 127+00128+00129+00107 172 173 174 175-SQU Const. Li m i t s Const. Limits Co n s t . L i m i t s Const. Limits Cons t . L im i t sConst. LimitsR/WR/ W (woods)5.0'22 4.0 Tons Of Revetment Riprap & 9.1 Sys Of Geotextiles Req'd.26File Name: \\ucs04fs\road\roadteam3\C3D\16-404\Road\Dwg\Plans\Plan & Profile.dwg Plot Date: 2/27/2017 Plotted By: Nimz, John1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKHEKJNII WRC WRC 1" = 20' 1" = 5" - - - - 54 200 16-ENG-52 PLAN & PROFILE LINE "PR-S-1-A" CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN See Plat No. 1 sheets for Right Of Way information. Line "PR-S-1-A" to be constructed. All proposed construction station/offsets are described from Line "PR-S-1-A" unless otherwise noted. LEGEND HMA for Approaches 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" Placed w/ Minimum Of 3 Lifts, on Multi-Use Path 110 #/Sys HMA Surface, Type "A" on 330 #/Sys HMA Intermediate, Type "A" on 5" Compacted Aggregate, No. 53, Base Truck Apron Decorative PCCP, 7" 165 #/Sys HMA Surface, Type "C" on 275 #/Sys HMA Intermediate, Type "C" on 385 #/Sys HMA Base, Type "C" on 250 #/Sys HMA Intermediate, OG, Type "C" on 330 #/Sys HMA Base, Type "C" Milling, Asphalt, 1 12" 165 #/Sys HMA Surface, Type "C" Curb & Gutter, Type II Curb & Gutter, Type III Roll Curb Concrete Center Curb, Type D Nursery Sodding D1 F1 F K K1 17 22 26 15 16 RPCCP for Approaches, 9" on Subgrade Treatment, Type II C3 PCCP for Approaches, 6" on Subgrade Treatment, Type II C1 M Integral Barrier Curb18 Curb Ramp, ConcreteCR Sidewalk, 4" on 4" Compacted Aggregate, No. 53, Base HMA for Widening 165 #/Sys HMA Surface, Type "C", on 275 #/Sys HMA Intermediate, Type "C", on 1045 #/Sys HMA Base, Type "C" W Revised Plan & Profile1 1 Subgrade Treatment, Type IB Placed w/ Minimum Of 3 Lifts, on Subgrade Treatment, Type IB 1 Revised Plan & Profile3 3 Moved Str. No. 1073 847.32 846.71 846.59 847.16 846.55 846.43 2.0% 2.0% 2.0%7.6%8'-0"8'-0"8'-0"1.5%7.6%1.5%846.49 846.99 846.71 846.59 846.81 3'-8" 1 0 ' - 1 0 " 11'-0"8'-0"843.35 843.27843.43 843.40 843.53 843.65 6'-0" 3.67%1.5% 2.17%1.5%0.38%843.48 843.63 6'-0" 6'-0 " 843.26 843.44 843.44 1.5%843.35 843.23 1'-0" 843.27 2'-0" 6'-8"6'-0"11'-0"6'-0" 4'-6" 817.28 817.15 817.19 817.76 817.66 817.84 818.14 1.5% 817.58 817.88 1.5 %8.0%1.5%6'-0"8.0%4.2%818.24 106TH ST.8'-6" 5'-0"8'-0"2'-0" 6'-0" 4'-3"8'-0"8'-0" 2'-2"1.5%1.5%0.4% 2.0%7.67% 7.67%1.5%6.6%0.9% 6.6%1.9% 836.50 836.04 836.01 836.62 836.18 836.16 836.27 836.72 836.19 836.84 836.31 836.156'-0" 836.58 836.20 836.03 836.29 836.29 836.54 837.92 837.80 837.68 837.61 837.43 837.42 837.18 837.22 836.93 837.03 10'-0"8'-0"10'-0"10'-0"10'-0"6'-0"8'-11"SPRING MILL LN .1.5%1.3%0.50%0.13%0.88%1.5%836.26 1'-0" 1'-0"836.18 836.16 1'-0" 836.00 845.15 845.50 845.84 846.19 846.53 846.88 847.00846.63846.26845.88845.54845.17 843.42 843.77 844.11 844.46 844.80 844.78844.41844.04843.67843.30 10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"10'-0"123+60.0124+60.010'-6"2'-4"8'-0"8'-0"8'-0" 844.56 844.60 844.10 844.13 844.47 844.78 843.47 843.69 843.90 844.11 0.5%0.38%6.25% 4.75% 1.9% 843.456'-0"6'-0" 844.13 0.5% 843.90 844.41 3'-6" 1'-0" 847.33 847.50 847.14 847.47 847.58 847.39 1.7% 0.6 3 %8'-0"8'-0"1.1 % 1.4% 9'-7 " 9'-10" 8'-0" 7'-6 "8'-5"2.0%847.08 846.89 847.64 846.97846.83 847.00 847.55 847.67 846.79 847.07 847.19 847.04 1.5 % 8'- 0 " 846.92 1.5 % 1.5 %8.0%8.0%1.9%6'-0"8'-0"5'-0 " 5.6 % 6.0 %1.9%847.45 846.79 846.95 847.07 846.62 846.57 846.62 124+001.50%824.96 825.08 824.16 824.25 823.36 823.37 822.57 822.51 821.82 821.721.25%0.75%0.13%1.13%1.50%821.00 821.14 8.0'10.0'10.0'10.0'10.0'10.0'10+85.2 "Path"11+35.2 "Path"File Name: P:\C3D\16-404\Road\Dwg\Plans\Curb Ramp Details.dwg Plot Date: 12/19/2017 Plotted By: Curtis, Bill1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKCCRJNII WRC WRC AS SHOWN AS SHOWN - - - - 57 200 16-ENG-52 CURB RAMP & MULTI-USE PATH GRADING DETAILS CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN 620.13 37 620.13 37 Existing Spot Elevation Proposed Spot Elevation LEGEND RAMPS & MULTI-USE PATH @ SPRING MILL LN. & SPRING MILL RD. Scale: 1" = 5' RAMPS @ EAST LEG OF SPRING MILL RD./111TH ST. ROUNDABOUT Scale: 1" = 5' MULTI-USE PATH ALONG SPRING MILL RD. Scale: 1" = 5' RAMP @ NORTH EAST SIDE OF SPRING MILL RD./106TH ST. ROUNDABOUT Scale: 1" = 5'111TH ST.SPRING RIDGE DR.RAMPS @ SPRING RIDGE DR. & SPRING MILL RD. Scale: 1" = 5' MULTI-USE PATH ALONG SPRING MILL RD. Scale: 1" = 5' Revised Grading Detail1 1 Revised Grading Detail6 6 6 845.28 845.41 844.98 844.85 844.78 844.86 7.2% 7.2%1.6%1.6%6'-0"14'-6" 0.80% 4'-6" 1.6% 845.71 845.81 845.33 845.23 845.07 845.11 8'-0"8'-0"1.3%8.0%1.3%8.0% 1.8% 2.7% 14'-4"6'-0" 4'-6" 845.07 845.11 845.55 845.05 845.15 845.65 845.98 845.88 846.14 846.08 2.0% 1.6% 10.0'3'-11"4'-8"1.6%2.0%845.19 845.14 845.39845.39 5'-0" 2.7% 1.9%1.4%3' -8" 845.41 844.86 844.98 844.78845.22 844.72 6.0'6 . 0 ' 9.1' 5.4'4.2'1.9'847.79 847.64 847.49 847.64 846.98 847.17 10'-0"6'-0" 11'-9"1.5%2.5% 1.8%1.5%2.7% 2.7% 2.5% 2.0% 847.46 8'-8"17'-6"10'-3"6'-0"28'-3" 11'-3" 2.2% 1.5% 2.2%1.2%1.4%847.72 847.86847.73 847.61847.19 847.48 846.98 847.17 847.59847.09 6 . 0 ' 847.47 846.97 6.0'847.63 847.19 847.13 848.17847.67 847.48 6'-0"17'-4" 846.95 847.55 847.05 847.61 847.61 847.56 847.17 847.29 847.73 847.20 847.91 847.41 847.96 847.46 848.10 848.22847.58 19'-1"8'-0"8'-0"8'-0"1.5%1.5%7.3% 2.0% 2.0% 2.0%1.5%5'-9" 7.3% 0.8% 6'-8"1.5%8.0% 8.0%File Name: \\ucs04fs\road\roadteam3\C3D\16-404\Road\Dwg\Plans\Curb Ramp Details.dwg Plot Date: 2/27/2017 Plotted By: Nimz, John1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKCCRJNII WRC WRC AS SHOWN AS SHOWN - - - - 59 200 16-ENG-52 CURB RAMP & MULTI-USE PATH GRADING DETAILS CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN 620.13 37 620.13 37 Existing Spot Elevation Proposed Spot Elevation LEGEND RAMPS @ DRIVE SOUTH OF BRIDGES II & SPRING MILL RD. Scale: 1" = 5' SPRING MILL RD. SPRING MILL RD. RAMPS @ BURLINGTON LN. & SPRING MILL RD. Scale: 1" = 5'BURLINGTON LN.SOUTH ENTRYTO BRIDGES IIRevised Grading Detail1 1 SPRING MILL RD.HERITAGE ATSPRING MILLAdded Grading Detail3 3 858.57 858.59 858.25 858.23 857.908'-0"6'-0"17'-5" 5.7%0.25%5.7%2.0%0.25%858.23 17.4'6.0' 856.89 856.89 8.0%1.5%857.01 8.0%1.5%1.2% 856.80 856.80 859.43858.93858.57 858.80 859.29 6'-0"17'-5"8'-0"8.3%1.6%1.7%858.79 8.2% 2.0% 858.80 I I I I I I I I I I I I I I I I I I I 850.48 850.58 1.5%851.44 851.53 1.5%852.60 852.71 1.5%854.60 854.600.0%856.75 856.631.5%191+00 192+00 193+00+72.1+21.9+71.7+22.2+72.250.0' 50.0' 50.0' 50.0'IIIIIIIIIIIIIIIIIIIIIIIIIIIII I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I849.92 850.02 1.5%849.62 849.73 1.5%849.34 849.45 1.5%849.42 849.42 0.0%849.46 849.40 0.75%848.95 848.83 1.5%193+00 194+00 195+00+33.8+83.8+09.2+51.7+83.8+33.8856.73 857.06 8'-0"9'-9"1.5%3.4%857.80 857.79857.54857.30 8.3'8.3'8.3'8.3' 857.44857.09 858.15 858.039.3'8.9'8.4'0.12%1.1%2.3%15.2'6.0'8.0'858.02 857.54 8.0% 857.90 857.40 8.0% 857.42 857.42 857.23 857.23 2.0%File Name: \\ucs04fs\road\roadteam3\C3D\16-404\Road\Dwg\Plans\Curb Ramp Details.dwg Plot Date: 2/27/2017 Plotted By: Nimz, John1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKCCRJNII WRC WRC AS SHOWN AS SHOWN - - - - 61 200 16-ENG-52 CURB RAMP & MULTI-USE PATH GRADING DETAILS CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN 620.13 37 620.13 37 Existing Spot Elevation Proposed Spot Elevation LEGEND RAMPS @ JACKSONS GRANT BVLD. & SPRING MILL RD. Scale: 1" = 5' MULTI-USE PATH ALONG SPRING MILL RD. @ TIE-IN TO EXISTING PATH Scale: 1" = 5' MULTI-USE PATH @ ALONG SPRING MILL RD. IN VICINITY OF BRIDGE NO. 32 Scale: 1" = 10' SPRING MILL RD. SPRING MILL RD. SPRING MILL RD.MatchlineMatchlineBRIDGE NO. 32BRIDGE NO. 32 BRIDGE NO. 32 Revised Grading Detail1 1 RAMPS @ JACKSONS GRANT BVLD. & SPRING MILL RD. Scale: 1" = 5' Added Curb Ramp Details3 3 +48.6+80.614.0' 11.0'+76.0+80.614.0' 5.5' 5.5'5.5' 5.5' 13.0' 11.0' 13.0'+42.3+42.311.0' 13.0'+09.311.0' 13.0'+09.330 30 3335 34 38 30 132+00 133+00 134+00 135+00 136+00 137+00 Sta. 132+69.92 "PR-A" R1-1 (30x30) on 10.2' post Sta. 133+15.48 "PR-A" D3-1(1) (43x10) D3-1(5) (45x10) on Street Sign Post Sta. 131+41.39 "PR-A" R4-7 (18x24) on 9.7' post +96.5+65.340 19.0'+60.5+29.240 40 40 +17.740 +91.240 5.5' 5.5'+27.6+55.030 3335 34 +75.5+44.240 40 Line "PR-A"Line "PR S-1-A"11.0'+55.711.0' 4.0' 37 37 37 37 35 34 126+00 127+00 128+00 129+00 130+00 131+00 32 32 32 30 30 30 30 30 30 39 39 3937 128+40.00 "PR-A" R6-4 (24x12) on 9.7' pole Sta. 125+63.13 "PR-A" R4-7 (18x24) on 9.7' post Sta. 127+21.63 "PR-A" W11-2 (30x30) W16-7P (24x12) on 11.2' post Sta. 127+50.33 "PR-A" R1-2 (36x36x36) on 10.3' post Sta. 127+40.32 "PR-A" W11-2(30x30) W16-7P(24x12) on 11.2' post Sta. 129+46.66 "PR-A" W11-2 (30x30) W16-7P (24x12) on 11.2' post Sta. 131+17.39 "PR-A" W2-6 (30x30) W16-8P(3) (25x8) W13-1P(15) (18x18) on 11.2' post Sta. 125+65.69 "PR-A" W2-6 (30x30) W16-8P(3) (25x8) W13-1P(15) (18x18) on 11.2' post 34+00 35+00 35+53 Sta. 34+68.83 "Path" Walk Bike (12x18) on 10.3' post R231.7'R104.2' R69. 6' Sta. 128+17.66 "PR-A" D3-1(6) (40x10) on Street Sign Post Sta. 129+08.12 "PR-A" R1-2 (36x36x36) on 10.3' post Sta. 129+23.17 "PR-A" W11-2 (30x30) W16-7P (24x12) on 11.2' postSta. 129+05.37 "PR-A" D3-1(6) (40x10) on Street Sign Post File Name: \\ucs04fs\road\roadteam3\C3D\16-404\Road\Dwg\Plans\Marking & Signing Plan.dwg Plot Date: 2/27/2017 Plotted By: Nimz, John1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKCJDDJZ BSF CJD 1" = 20' N/A - - - - 70 200 16-ENG-52 SIGNING & PAVEMENT MARKING PLAN LINE "PR-A" CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN PAVEMENT MARKING LEGEND 30 Line, Thermoplastic, Solid, White, 4" 40 33 Transverse Marking, Thermoplastic, Yield, White, 18" Line, Thermoplastic, Solid, Yellow, 4" 32 38 Transverse Marking, Thermoplastic, Crosswalk Line, White, 24" 35 Raised Pavement Marker, Type 2, yellow 36 Transverse Marking, Thermoplastic, Crosswalk Line, White, 6" Existing Ground Mounted Sheet Sign SIGNING LEGEND Line, Thermoplastic, Dotted, White, 8" Line, Thermoplastic, Solid, Yellow, 8"34 Line, Thermoplastic, Solid, Yellow, 12" Transverse Marking, Thermoplastic, Stop Line, White, 24" 39 Pavement Message Marking, Thermoplastic, Lane Indication Arrow Proposed Ground Mounted Sheet Sign 31 Line, Thermoplastic, Broken, White, 4" 37 All sign posts shall be 12' (type 1, 2 14" x 2 14" x 12 ga.) Square sign posts with reinforced anchored base, Sign posts shall be black powder coated finish NOTE Matchline - Sta. 137+50 "PR-A"Matchline - Sta. 131+25 "PR-A"Matchline - Sta. 131+25 "PR-A"Matchline - Sta. 125+00 "PR-A"Added Street Approach,3 Revised Pavement Markings3 30 33 30 3040 40 40 40 30 40 33 40 33 3534 13.0'+44.55.5' 5.5' 11.0' 13.0'+14.95.5' 5.5' 11.0'+41.111.0'11.0'+08.6+08.614.0'+14.95.5' 5.5'+62.15.5'+03.531 31 11.0' 11.0' 144+00 145+00 146+00 147+00 148+00 149+00 11.0' 11.0'40 Existing Sta. 144+29.32 "PR-A" Existing Sta. 146+26.15 "PR-A"Sta. 149+73.60 "PR-A" W2-6 (30x30) W16-8P(4) (25x8) W13-1P(15) (18x18) on 11.2' post 37 38 +20.4+00.9+55.2+31.6+13.7+31.8+14.840 40+85.15.5' 5.5' 13.0'+85.15.5' 5.5'+17.1+89.730 33 35 34 30 3335 34 30 33 138+00 139+00 140+00 141+00 142+00 5.5' 5.5' 13.0'+41.111.0'+09.1+36.6Sta. 137+98.75 "PR-A" R1-1 (30x30) on 10.2' post 37 38 40 40 +68.1+00.230 +21.5+21.511.0'11.0'40 40 +13.7+33.3+59.65.5' 5.5'File Name: \\ucs04fs\road\roadteam3\C3D\16-404\Road\Dwg\Plans\Marking & Signing Plan.dwg Plot Date: 2/27/2017 Plotted By: Nimz, John1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKCCRJNII WRC WRC 1" = 20' N/A - - - - 71 200 16-ENG-52 SIGNING & PAVEMENT MARKING PLAN LINE "PR-A" CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN PAVEMENT MARKING LEGEND 30 Line, Thermoplastic, Solid, White, 4" 40 33 Transverse Marking, Thermoplastic, Yield, White, 18" Line, Thermoplastic, Solid, Yellow, 4" 32 38 Transverse Marking, Thermoplastic, Crosswalk Line, White, 24" 35 Raised Pavement Marker, Type 2, yellow 36 Transverse Marking, Thermoplastic, Crosswalk Line, White, 6" Existing Ground Mounted Sheet Sign SIGNING LEGEND Line, Thermoplastic, Dotted, White, 8" Line, Thermoplastic, Solid, Yellow, 8"34 Line, Thermoplastic, Solid, Yellow, 12" Transverse Marking, Thermoplastic, Stop Line, White, 24" 39 Pavement Message Marking, Thermoplastic, Lane Indication Arrow Proposed Ground Mounted Sheet Sign 31 Line, Thermoplastic, Broken, White, 4" 37 All sign posts shall be 12' (type 1, 2 14" x 2 14" x 12 ga.) Square sign posts with reinforced anchored base, Sign posts shall be black powder coated finish NOTE Matchline - Sta. 150+00 "PR-A"Matchline - Sta. 143+75 "PR-A"Matchline - Sta. 143+75 "PR-A"Matchline - Sta. 137+50 "PR-A"Revised Pavement Markings3 Added Street Approach,3 168+00 169+00 170+00 171+00 172+00 173+00 161+00 162+00 163+00 165+00 166+00 30 33 5.5' 5.5' 35 34 5.5' 5.5'+71.0+43.5+53.030+26.4+43.5+47.0+95.0+35.2+27.7File Name: \\ucs04fs\road\roadteam3\C3D\16-404\Road\Dwg\Plans\Marking & Signing Plan.dwg Plot Date: 2/27/2017 Plotted By: Nimz, John1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKCCRJNII WRC WRC 1" = 20' N/A - - - - 73 200 16-ENG-52 SIGNING & PAVEMENT MARKING PLAN LINE "PR-A" CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN PAVEMENT MARKING LEGEND 30 Line, Thermoplastic, Solid, White, 4" 40 33 Transverse Marking, Thermoplastic, Yield, White, 18" Line, Thermoplastic, Solid, Yellow, 4" 32 38 Transverse Marking, Thermoplastic, Crosswalk Line, White, 24" 35 Raised Pavement Marker, Type 2, yellow 36 Transverse Marking, Thermoplastic, Crosswalk Line, White, 6" Existing Ground Mounted Sheet Sign SIGNING LEGEND Line, Thermoplastic, Dotted, White, 8" Line, Thermoplastic, Solid, Yellow, 8"34 Line, Thermoplastic, Solid, Yellow, 12" Transverse Marking, Thermoplastic, Stop Line, White, 24" 39 Pavement Message Marking, Thermoplastic, Lane Indication Arrow Proposed Ground Mounted Sheet Sign 31 Line, Thermoplastic, Broken, White, 4" 37 All sign posts shall be 12' (type 1, 2 14" x 2 14" x 12 ga.) Square sign posts with reinforced anchored base, Sign posts shall be black powder coated finish NOTE Matchline - Sta. 173+25 "PR-A"Matchline - Sta. 167+00 "PR-A"Matchline - Sta. 167+00 "PR-A"Matchline - Sta. 160+75 "PR-A"Added Pavement Markings1 1 3 Revised Pavement Markings3 E 116th St E 116th St IIIIIIIIIIIIIIIIIIIIIIIIIIIII I I IIIIIIIIIIII I I I I I I II IIIIIIIIIIIIIII I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I IIII I I IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII I I I I I I I I I IIIIIIIIIIIII 126+56 127+81 132+92 137+68 144+55 145+99 173+76 178+60 182+37 189+30 192+05 192+42 195+31 200+30 200+56 201+47 201+77 203+07 204+39 207+10 207+68 212+26 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE 1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKJRSJNII WRC WRC N/A N/A - - - - 110 200 16-ENG-52 STRUCTURE DATA TABLE CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN Revised Structure Data Table3 3 3 RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE 1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKJRSJNII WRC WRC N/A N/A - - - - 111 200 16-ENG-52 STRUCTURE DATA TABLE CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN Revised Structure Data Table3 3 3 3 3 1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKJRSJNII WRC WRC N/A N/A - - - - 112 200 16-ENG-52 STRUCTURE DATA TABLE CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE Revised Structure Data Table1 1 1 Revised Structure Data Table3 3 3 3 Revised Structure Data Table4 3 1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKJRSJNII WRC WRC N/A N/A - - - - 113 200 16-ENG-52 STRUCTURE DATA TABLE CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE Revised Structure Data Table1 1 Revised Structure Data Table3 3 1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKJRSJNII WRC WRC N/A N/A - - - - 114 200 16-ENG-52 STRUCTURE DATA TABLE CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE Revised Structure Data Table1 1 Revised Structure Data Table3 3 3 1625 N. Post Road Indianapolis, IN 46219 Phone 317-895-2585 Fax 317-895-2596 www.ucindy.comConsultingUNITED DESIGNED: CHECKED: DRAWN: CHECKED: RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE SHEETS of VERTICAL SCALE HORIZONTAL SCALE CONTRACT BRIDGE FILE PROJECT DESIGNATION SURVEY BOOKJRSJNII WRC WRC N/A N/A - - - - 116 200 16-ENG-52 STRUCTURE DATA TABLE CITY OF CARMEL SPRING MILL ROAD FROM 111TH TO MAIN RECOMMENDED FOR APPROVAL DESIGN ENGINEER DATE Revised Structure Data Table1 1 Revised Structure Data Table3 3 NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & IIIIIIIIIIIIIII I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I III I I I NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII I I I I I I I I I NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & NOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation & IIIIIIIIIIIIINOTES: 1)SURVEY INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE SURVEY, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 2)ROAD PLAN INFORMATION WAS PROVIDED BY UNITED CONSULTING. CROSSROAD ENGINEERS IS RESPONSIBLE FOR THE WATER/SEWER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANY DISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT UNITED CONSULTING AT (317) 895-2585. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFY ALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORT ANY DISCREPANCIES TO THE WATER/SEWER MAIN DESIGNER. 4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCE WITH INDOT STANDARDS AND SPECIFICATIONS. 5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITH ROAD PROJECT IMPROVEMENTS. Development ConsultantsTransportation &