HomeMy WebLinkAboutCeiling_A2012 REFLECTED CEILING PLAN - MECHANICAL
SCALE: sns = T-T
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City N Cam e1 (�
�VT�'law�NaA�+L
DATE: \ 10/03/19
0
IV
REFLECTED CEILING PLAN LEGEND
NOT IN CONTRACT
DENOTES NEW 2W' ACOUSTICAL CEILING GRID/TILE
i�i DENOTES OPEN CEILING TO STRUCTURE
DENOTES GYPSUM CEILING
DENOTES NEW 2k2' RECESSED ELECTRICAL FIXTURE - BUILDING
STANDARD OR EQUAL
L1
DENOTES RECESSED CAN LIGHT- BUILDING STANDARD OR EQUAL
L2
DENOTES DECORATIVE WALL SCONCE- STILETTO TALL LED DIMMABLE
L3 WALL SCONCE, SATIN BLACK MFR ID: 2342.2SDIM ITEM #: SON210036
DENOTES DECORATIVE CHANDELIER - FIX STICKS CIRRUS D1 LENS
SUSPENSION WITH POWER MFR ID: PX3P-D1-5W-60-27K-SN ITEM #
L4 EDG568576 MOUNT T-6" A.F.F.
DENOTES DECORATIVE PENDANT, MARIMBA CHANDELIER - GOLD LEAF/ DARK BRONZE
LS 18" MFR ID: PD52718-GL ITEM# MFR201694, MOUNT 6' A.F.F.
DENOTES LINEAR SUSPENDED LED PENDANT-ALCONLIGHTING 1210045-P CONTINUUM 45
L6 SERIES ARCHITECTURAL LED LINEAR PENDANT MOUNT DIRECT/INDIRECT LIGHT FIXTURE,
4 FOOT, 48 WATTS, 3500K, BLACK
® DENOTES NEW EMERGENCY EXIT SIGN
DENOTES NEW EMERGENCY LIGHT
DENOTES LIGHT SWITCH
�D
DENOTES LIGHT SWITCH WITH DIMMER
�3
DENOTES LIGHT SWITCH WITH THREE-WAY SWITCH
NOTE: CONTRACTOR TO VERIFY DIFFUSER LOCATIONS AND SUPPLY FINAL DUCT LOCATIONS AND SIZING.
GENERAL REFLECTED CEILING PLAN NOTES
A. PAINT NEW GYPSUM BOARD BULKHEADS P-1, UNLESS OTHERWISE NOTED.
B. REMOVE EXISTING SWITCHES THATARE NOT RE -USED. REMOVE CONDUITAND WIRING BACK TO
NEAREST BASE BUILDING JUNCTION BOX. PATCH AND REPAIR WALL FOR NEW FINISH.
C. THE GENERAL CONTRACTOR AND THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING
HEIGHTS AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING, AND
OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT INDICATED. ANY DISCREPANCY
SHALL BE BROUGHT TO THE DESIGNER'S ATTENTION PRIOR TO PERFORMING ANY WORK.
D. CEILING HEIGHT THROUGHOUT THE SPACE IS TO STRUCTURE, UNLESS NOTED OTHERWISE.
E. EXISTING CEILING GRID AND ACOUSTICAL TILE TO REMAIN, UNLESS NOTED OTHERWISE.
CONTRACTOR TO REMOVE AND REPLACE ANY EXISTING CEILING TILES AND CEILING GRID THAT IS
BROKEN, CHIPPED, OR PUNCTURED WITH NEW TO MATCH EXISTING.
F. ALL NEW SWITCHES FOR LIGHTING SHALL BE LOCATED AS SHOWN ON PLANS. MOUNT CENTER OF
SWITCH 6"-9" FROM EDGE OF DOOR FRAME, UNLESS NOTED OTHERWISE.
G. EXIT SIGNS, DOWN LIGHTS, SPRINKLER HEADS, ETC. SHALL BE CENTERED WITHIN TILE, UNLESS
NOTED OTHERWISE.
H. COLOR OF LIGHT SWITCH DEVICES AND COVERPILATE TO BE WHITE, UNLESS NOTED OTHERWISE.
I. ALL MULTIPLE SWITCH LOCATIONS TO BE GROUPED TOGETHER AND LABELED WITH A SINGLE
DEVICE COVERPLATE.
J. REFER TO ENGINEERING DOCUMENTS FOR INFORMATION, LOCATION AND SPECIFICATIONS ON EXIT
SIGNAGE, LIFE SAFETY SYSTEMS, 24 EMERGENCY LIGHTING, VENTILATIONS, HVAC SYSTEMS,
CIRCUITING OF LIGHTS AND THERMOSTAT LOCATION ETC.
K. THERMOSTATS SHALL BE LOCATED DIRECTLY ABOVE OR ADJACENT TO LIGHT SWITCH. ALL
THERMOSTAT POSITIONS AND LOCATIONS TO BE COORDINATED WITH THE DESIGNER BEFORE
PLACEMENT.
L. SUPPLYAND RETURN AIR GRILLES ARE TO BE FLUSH WITH NEW CEILING TILES AND ARE TO BE
WHITE IN COLOR. REFER TO ENGINEERING DOCUMENTS FOR ADDITIONAL INFORMATION.
M. ALL DIMENSIONS ARE TO THE CENTERLINE OF FIXTURE, UNLESS NOTED OTHERWISE.
N. IF REQUIRED, ALL CEILING MOUNTED EQUIPMENT LOCATIONS TO BE COORDINATED WITH THE
DESIGNER PRIOR TO INSTALLATION.
O. VERIFYALL SPRINKLER HEAD LOCATIONS. NOTIFY DESIGNER IF ANY DISCREPANCIES OCCUR.
ADJUST HEAD LOCATIONS BASED ON NEW LAYOUT.
## REFLECTED CEILING PLAN KEYNOTES
01 EXPOSED CEILING, OPEN TO DECK OR STRUCTURE ABOVE. PAINT ENTIRE UNDERSIDE OF DECK AND
STRUCTURAL FRAMING MEMBERS, AND ALL ASSOCIATED ITEMS (DUCTWORK, PIPING, CONDUIT, ETC.)
P-3, FLAT FINISH. REFER TO FINISH PLAN FOR ADDITIONAL INFORMATION.
02 RELOCATE EXISTING FCU AS NEED/REQUIRED FOR PLACEMENT OF DEMISING WALL.
MITSCH
D E S I G N
200 S. Rangeline Rd. I Suite 226
Carmel, Indiana 46032
317.573.2222
www.milschdesgn.com
Pop
hhw AL
TNEPLDIDDLED�I
OF
O
O
N
w
V)
Q
Z
O z .J
W WZ�w
Vzzco
O Qw
aj t
U z LLI 2
r_ a
Q LJJ
W a�UD_
O
r
mpaE
a_
¢
$8
m
0
U
N
Q
Go
y
O
y
a
w
�
m
0
Z m l/1
F-
w�w
qax
wrc�
'�
o
ttww
SOU
aaa
NL IDEAS, GESGNSPNG FINDS (GRGINAL WORKS OF
AUTHORSHIP FIXED INATANGIME MEDIUM OF EXPFESSON)
INDICATED OR PRESENTED BY THESE DRAWINGS AND
OM ENTS ME OWNED BY, AND ME THE PROPERTY OF
MITSCH DESIGN. ALLPGHTG XEGEWED. EXCEPT FOR USES
EXPRESSLY PERMITTED IN WRITING
REFLECTED CEILING
PLAN - FIRST FLOOR
A201