HomeMy WebLinkAboutElectrical_AE101INK
OC.O
i TIE TO EXIT. ^
2" VTR i
i
' WC
q,
LAIV WC �� 4"
1.51 l �i WC
\� LAV \ w LAV
\I, URINAL
G
LAV 1.5" 1.5"
I
\ \ \ TIE INTO EXISITING SEWAGE LINE
- I
2 PLUMBING RISER DIAGRAM
SCALE: NTS
Subject to compliance with all regulations
of State and Local Codes
ELECTRICAL LEGEND
NOT IN CONTRACT
STANDARD DUPLEX RECEPTACLE
STANDARD QUAD DUPLEX RECEPTACLE
STANDARD DUPLEX RECEPTACLE (W/ WHIP)
STANDARD RECEPTACLE (VOICE/DATA)
STANDARD RECEPTACLE (VOICE/DATA W/ WHIP)
Oa STANDARD FLOOR RECEPTACLE (POWER)
STANDARD FLOOR RECEPTACLE (POWER W/ WHIP)
® (S�TpANNDDA�RgD FLOOR RECEPTACLE
®--- RIINOARO FLOOR RECEPTACLE (VOICE/DATA W/ WHIP)
GFI DENOTES GROUND FAULT
TV IbI1lJBW?Tf?M FOR TENANT PROVIDED TV
+pp DENOTES CENTERLINE MOUNTING HEIGHT OF OUTLET/RECEPTACLE
NOTE: ALL EXISTING ELECTRICAL PANEL LOADS & SERVICE REMAIN. OULETS NOT SHOWN ARE
EXISTING TO REMAIN.
GENERAL ELECTRICAL/DATA NOTES
A. THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE DESIGNER OF ANY DISCREPANCIES
BETWEEN THE CONTRACT DOCUMENTS AND APPLICABLE CODES PRIOR TO
CONSTRUCTION.
B. ELECTRICAL CONTRACTOR TO COORDINATE ALL SPECIAL ELECTRICAL EQUIPMENT
REQUIREMENTS AS INDICATED ON DRAWINGS OR AS REQUIRED BY TENANT. VERIFY
ACTUAL REQUIREMENTS WITH DESIGNER PRIOR TO INSTALLATION.
C. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES AND PULL STRINGS AT
TELEPHONE/DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE TELEPHONE/DATA
SYSTEMS (MATERIAL AND LABOR) TO BE PROVIDED BY THE TENANT UNLESS
OTHERWISE NOTED.
D. ALL SECURITY SYSTEMS TO BE PROVIDED BY TENANT UNLESS NOTED OTHERWISE
E. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL AND LIGHTING
REQUIREMENTS FOR MILLWORK AND CABINETRY WITH CONTRACTOR AS NECESSARY.
F. ALL WALL MOUNTED OUTLETS ARE TO BE MOUNTED VERTICALLY ATxxx" A.F.F. TO
CENTERLINE OF OUTLET, UNLESS OTHERWISE NOTED.
G. SWITCH PLATES,MONUMENTS, AND ELECTRICAL COVER PLATES SHALL BE BUILDING
STANDARDS COLOR.
H. ALL DIMENSIONS SHOW ARE TO CENTERLINE OF OUTLETS OR GROUP OF OUTLETS,
UNLESS OTHERWISE NOTED.
I. DO NOT LOCATE BOXES BACK TO BACK WITHIN PARTITIONS. STAGGER AS REQUIRE TO
MINIMIZE SOUND TRANSMISSION.
J. ADJACENT OUTLETS SHALL BE GANGED WHEN POSSIBLE. IF THEY CANNOT BE
GANGED, THEY SHALL BE INSTALL WITH A MIN. DISTANCE BETWEEN UNITS.
K. CONTRACTOR TO PROVIDE ALL FIRE LIFE SAFETY DEVICES AS REQUIRED BY STATE
AND LOCAL BUILDING CODES.
L. ELECTRICAL CONTRACTOR TO VERIFY WORKING CONDITION OF ALL SWITCHES, LIGHT
FIXTURES, BALLASTS, EXIT AND EMERGENCY LIGHTS AND OUTLETS, REPLACE IF
NECESSARY.
M. DO NOT SCALE DRAWINGS; ALL DIMENSIONS GIVEN ARE TO BE ADHERED TO, UNLESS
FIELD CONDITIONS DEEM OTHERWISE. ANY CONFLICTS THAT MAY EXIST WITH NEW
CONSTRUCTION MUST BE REVIEWED BY DESIGNER PRIOR TO CONSTRUCTION OR
WORK. DO NOT CIRCUMVENT DIMENSIONS BY ATTACHED RECEPTACLES TO NEAREST
STUD.
N. THESE ELECTRICAL DRAWINGS REFLECT LOCATIONS ONLY. CONSULT WITH
ELECTRICAL ENGINEER FOR FURTHER TECHNICAL INFORMATION.
O. ELECTRICAUDATA OUTLET LOCATION TO BE VERIFIED WITH TENANT PRIOR TO ROUGH.
IN. ALL LOCATIONS TO BE VERIFIED WITH FURNITURE PLACEMENT.
P. SYSTEMS FURNITURE TO BE DRAWING ON FLOOR PRIOR TO PLACEMENT OF FLOOR
CORE AND JUNCTION BOXES. DESIGNER TO APPROVE LOCATIONS PRIOR TO
CORING/PLACEMENT.
Q. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONNECTING DEALER PROVIDED
FURNITURE SYSTEMS POWER IN -FEED TO BUILDING J-BOX WHERE INDICATED ON PLAN.
® ELECTRICAL/DATA KEYNOTES
01 POKE-THRU FITTING FOR SYSTEMS FURNITURE POWER INFEED FOR ELECTRIFIED WORKSTATION
PANELS. SYSTEMS FURNITURE WHIP TO BE HARDWIRED DIRECTLY TO POKE-THRU. COORDINATE
LOCATION IN FIELD WITH TENANT'S FURNITURE VENDOR. REFER TO ENGINEERING DRAWINGS FOR
ADDITIONAL INFORMATION.
02 POKE-THRU FITTING WITH ELECTRICAL RECEPTACLES, DATAfVOICE OUTLETS AND AA1 CONNECTIONS.
DASHED LINE INDICATES CONDUIT PATH BENEATH FLOOR SLAB TO DESIGNATED PARTITION FOR
STUB -UP TO ACCESSIBLE CEILING. COORDINATE LOCATION IN FIELD WITH TENANT'S FURNITURE
VENDOR. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION.
03 REFER TO ELEVATIONS FOR ADDITIONAL INFORMATION AND EXACT LOCATION OF ALL NEW DEVICES
AT MILLWORK CABINETS AND ABOVE COUNTERTOP.
® FURNISH AND INSTALL DEVICES SHOWN FOR TENANT PROVIDED AND INSTALLED TELEVISION(S).
PROVIDE BLOCKING AS REQUIRED. COORDINATE EXACT LOCATIONS AND REQUIREMENTS WITH
TENANT PRIOR TO ROUGH -IN.
OS PLASTER RING WITH (1)3(4" CONDUIT AND PULL STRING TO ACCESSIBLE CEILING FOR TENANT
SUPPLIED AND INSTALLED ACCESS CONTROL DEVICE. MOUNT PLASTER RING 3'-6" A.F.F. TO
CENTERLINE.
OB DEDICATATED
07 CORRDINATE WITH OWNER ON WORKSTATION ELECTRICAL NEEDS
06 TV MOUNT SPEC; ATDEC, TH-3070-CTL TELEHOOK 3070 CEILING TILE LONG 1000-1900M M, BLACK
FINISH. MOUNT TO NOT EXCEED PAST 4" OFF COLUMN
09 CONFIRM WITH TENANTS IT VENDOR ON POWER NEEDS
MITSCH
D E S I G N
200 S. Rangeline Rd. I Suite 226
Carmel, Indiana 46032
317.573.2222
www.milschdesgn.com
OF
h1w. AL
TNEPLDIDDLED�I
OF lvpw�
O
0
7 N
I� w
V)
Q
Z
ZJo
W WZ\tw
P4 t7 z z_ C0
O Q w
0-
w ~
U z��
Q LU
W a�UD_
IIIII
\\\,\%%I11111
a
w
1Zli S
XTT//llIIIIIIIIIIP
Y•
z
z
O
O
y
rnm
=w
w
K
chi
M
J
U
p
W
Z
p
o o
tt
=
p
w
U
Y
U
U
Do
z
O
N
mp
2mm
OZwy.
�fr
aQw
wrcK
�pU
aaa
ALL IDEAS, GEBGNSPNG FINS (ORIGINAL WORKS Of
AUTHORSHIP FIXED INATANGIBLE MEDIUM OF EYPMESSCm
INDICATED OR PRESENTED BY THESE DFAW NGS AND
DOCUMENTS ARE OWNED BY, AND ARE THE PROPERTY OF
Mori DBAGN. ALL RIGHTS RESERVED, O CEPT FOR USES
EXPRESSLY PERMITTED IN W RRNG.
ELECTRICALIDATA
PLAN - FIRST FLOOR
AE101