HomeMy WebLinkAboutGN010.0 - ENERGY CERTIFICATEIECC 2009 Performance Compliance
P ro pe rty
11823 WEST RD
ZIONSVILLE, IN 46077
Model: FALCON
Community: WATERFRONTAT WE,'
WWC044 (AS DESIGNED)
WATERFRONTAT WEST CLAD 44
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PAUL SHOOPMAN
HOME BUILDING
GROUP
Design
Heating
Coaling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
S1,687
$296
$196
$2,180
$1,227
$0
$3,406
Requirements
C"IEriergy Solutions
As Designed
$1,759
$212
$196
$2,167
$1,206
$0
$3,373
405.3 Performance -based compliance passes by D.6%
® R41)2.4.1.2 Air Leakage Testing Air sealing is 5.00 ACH at 50 Pa. It must not exceed 7.00 ACH at 5D Pa.
402.5 Area -weighted average fenestration SHGC
402.5 Area -weighted average fenestration 1-1-Factor
® 4032.2 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052 Duct Insulation
Design exceeds requirements for IECC 2009 Performance compliance by 0.6%.
Asa 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zane 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date:
9117119at1:07PM
Ekotrope RATER - Version 3.1.0.2253
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
11823 WEST RD
ZIONSVILLE, IN 46077
Builder: PAUL SHOOPMAN HOME BUILDING GROUP
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls R-10
Framed Floor NIA
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 5 ACH50
Window U-Value: 0.3, SHGC: 0.25
Building Features
Duct Supply R-10.0, Return R-10.0
Duct Leakage to Outside 176 CFM25 (3.93 / 100 s.f.)
Total Duct Leakage 352 CFM25 (Post -Construction)
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Natural Gas • 0.64 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports; I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party_
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date: 9117f19 at 1:07 PM
Ekotrope RATER - Version 3.1.0.2253
2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
Energy Code Inspection Checklist
Property
Organization
11823 WEST RD
TSI Energy Solutions
ZIONSVILLE, IN 46077
Devin Sielschott
Model: FALCON
Community: WATERFRONTAT WE:
Builder
PAULSHOOP MAN
WWC044 (AS DESIGNED)
HOME BUILDING
WATER FRONT AT WEST CLAD 44
GROUP
General Building Information
Conditioned Area (sq ft) 4,484
Conditioned Volume (cubic ft) 57,294
Insulated Shell Area (sq ft) 12,462
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
] Name: BSMT(730 s.f., 55 ft. exterior perimeter)
R-0 perimeter insulation, R-0 under slab insulation.
] Name: CRAWL(3,024 s.f., 240 ft. exterior perimeter)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
] Name: CON DIAMB FIN (Exterior Perimeter [ft]: 15, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 9.696
Fully insulated (top to bottom)
] Name: CON DIGAR (Exterior Perimeter [ft]: 40, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R-0 continuous insulation, R-0 cavity insulation
Insulation Grade: I
Fully insulated (top to bottom)
] Name: CRAWLIAMB (Exterior Perimeter [ft]: 225, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 3)
R: 10.00
Fully insulated (top to bottom)
]l Name: CRAWLIGARAGE (Exterior Perimeter [ft]: 15, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 3) 1
R: 10.00
Fully insulated (top to bottom)
Energy Code Inspection Checklist
Property
11823 WEST RD
ZIONSVILLE, IN 46077
Model: FALCON
Community: WATERFRONT AT WE:
WWC044 (AS DESIGNED)
WATER FRONT AT WEST CLAD 44
Above Grade Wall
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PAULSHOOP MAN
HOME BUILDING
GROUP
Name: COND/AMB (2,442 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CON DIGAR (549 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CONDIATTIC (213 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
Name: CON DfAM B (240 s.f.)
R: 13.575
El Name: CON DIGAR (55 s.f.)
R: 13.575
Roof
Name: MAIN (3,754 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (24 s.f.)
U: 0.476
Name: GARAGE (24 s.f.)
U: 0.182
Name: GARAGE (22 s.f.)
U: 0.182
Inspection Status
Results are projected
C",
Energy Solutions
2
Energy Code Inspection Checklist
P ro pe rty
11823 WEST RD
ZIONSVILLE, IN 46077
Model: FALCON
Community: WATERFRONTAT WE,'
WWC044 (AS DESIGNED)
WATERFRONTAT WEST CLAD 44
Glazing
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PAUL SHOOPMAN
HOME BUILDING
GROUP
Inspection Status
Results are projected
Name: FRONT (76 s.f.), U: 0.300, SHGC: 0.25, Orientation: SOUTH
11 Name: FRONT RIGHT (36 s.f.), U: 0.300, SHGC: 0.25, Orientation: SOUTH—EAST
11 Name: BACK (64 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH
Name: BACK LEFT (85 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH—WEST
M Name: BACK LEFT SLIDER (64 s.f.), U: 0.300, SiHGC: 0.25, Orientation: NORTH—WEST
E] Name: BACK RIGHT (140 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH—EAST
CTMEnergy Solutions
Name: BACK RIGHT SLIDER (64 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH—EAST
E] Name: LEFT (35 s.f.), U: 0.300, SHGC: 0.25, Orientation: WEST
El Name: RIGHT (77 s.f.), U: 0.300, SHGC: 0.25, Orientation: EAST
[] Name: FRONT BSMT (15 s.f.), U: 0.300, SHGC: 0.25, Orientation: SOUTH
Skylight
None Present
Mechanical Ventilation
ElMechanical ventilation system rated for, and capable of, providing continuous ventilation.
System shall include automatic timing controls.
System type: Exhaust Only, 24 hrslday, 13.5 Watts.
Mechanical Equipment
3
a -A HEATING • Natural Gas • 100% Heating Load @ 92.1 AFUE
Energy Code Inspection Checklist
Property
Organization
11823 WEST RD
TSI Energy Solutions
ZIONSVILLE, IN 46077
Devin Sielschott
Model: FALCON
Community: WATERFRONT AT WE:
Builder
PAULSHOOP MAN
WWC044 (AS DESIGNED)
HOME BUILDING
WATER FRONT AT WEST CLAD 44
GROUP
COOLING • Electric- 100% Cooling Load @ 13 SEER
inspection Status
Results are projected
E] Water Heating • Natural Gas • 100% Hot Water Load @ 0.64 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 4,775 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Leakage to Outside specified as: 176 CFM25 (3.93 / 100 s.f.)
Total Leakage specified as: 352 CFM25 (Post -Construction)
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM251 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage a= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path. 4
Energy Code Inspection Checklist
Property
11823 WEST RD
ZIONSVILLE, IN 46077
Model: FALCON
Community: WATERFRONTAT WE:
WWC044 (AS DESIGNED)
WATER FRONT AT WEST CLAD 44
Project Notes
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PAULSHOOP MAN
HOME BUILDING
GROUP
inspection Status
Results are projected
C",
Energy Solutions
Building Summary
Property
Organization
Inspection Status
*Sl Energy Solutions
11823 WEST RD
TSI Energy Solutions
Results
are projected
ZIONSVILLE. IN 46077
Devin Sielschott
Model: FALCON
Community: WATERFRONTAT WEST CLAY 44
Builder
PAUL SHOOPMAN HOME
WWCO" (AS DESIGNED)
BUILDING GROUP
WATERFRONTAT WEST CLAY 44
General Building Information
Number Of Bedrooms
4
Number Of Floors
1
Conditioned Floor Area [sq. ft.]
4,484
Unconditioned; attached garage?
Yes
Conditioned Volume [cu. ft.]
57,294
Total Units in Building
1
Residence Type
Single family detached
Floor Number
Model
FALCON
Community
WATERFRONT AT WEST CLAY 44
Climate Zone
5A
Foundation Wall
Name Library type
Height Above Grade Depth Below Grade
Perimeter
Location Enclosing
CONDIAMB FIN R-11 Finished, G1
1
8
15
Exposed Exterior Conditioned Space
CONDIGAR Uninsulated
1
8
40
Exposed Exterior Conditioned Space
CRAWLIAMB R-10 Draped, Full
1
3
225
Exposed Exterior Conditioned Crawlspace
CRAWLIGARAGE R-10 Draped, Full
1
3
15
Exposed Exterior Conditioned Crawlspace
Foundation Wall Library List W
Name Feet From Wall Top To
Feet From Wall Top To
Is Fully Insulated
Continuous R-value
Cavity R-value Effective Insulation R-
Continuous Insulation
Continuous Insulation
value
Top
Bottom
R-10 Draped, Full NIA
NIA
Yes
NIA
NIA 10.00
R-11 Finished, G1 NIA
NIA
Yes
NIA
NIA 9.696
Uninsulated NIA
NIA
Yes
0.00
NIA NIA
Slab
Name Library Type
Perimeter Floor Grade
Carpet R
Exposed Surface
Area Location Enclosing
Masonry Area
BSMT Uninsulated
55 Below Grade
123
0 730.0
ft' Exposed Exterior Conditioned
Space
CRAWL Uninsulated
240 Below Grade
123
0 3,024.0
ft' Exposed Exterior Conditioned
Crawlspace
1
Building Summary
Property Organization Inspection Status
11823 WEST RD TSI Energy Solutions Results are projected
ZIONSVILLE. IN 46077 Devin Sielschott
Model: FALCON
Community: WATERFRONTAT WEST CLAY 44 Builder
PAUL SHOOPMAN HOME
WWC044 (AS DESIGNED) BUILDING GROUP
WATERFRONTAT WEST CLAY 44
Slab Library List
Name Wall Construction Slab Completel�r Underslab Perimeter Perimeter
Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value
Uninsulated Woad Frame 1 Other No ❑ 0 ❑
Framed Floor
None Present
Framed Floor Library List
None Present
Rim Joist
Name
CONDIAMB
CO N DIGAR
Rim Joist Library List
Name
G1 R-13, R-3.0
all
Name
CONDIAMB
CONDIATTIC
C"IEnergy Solutions
No 0.00
Library Type Surface Area Location
G1 R-13, R-3.0 240.0 ft' Exposed Exterior
G1 R-13, R3.0 55.0 ft' Unconditioned, attached garage
sulation R-value
13.575
G1 R-13 BATT, P3-0 Medium 2,442.0 ft' Exposed Exterior
G1 R-13 BATT R3.0 Medium 213.0 ft' Attic
Building Summary
Property
Organization
11823 WEST RD
TSI Energy Solutions
ZIONSVILLE. IN 46077
Devin Sielschott
Model: FALCON
Community: WATERFRONTAT WEST CLAY 44
Builder
PAUL SHOOPMAN HOME
WWC044 (AS DESIGNED)
BUILDING GROUP
WATERFRONTAT WEST CLAY 44
Name
Library Type
CONDIGAR G1 R-13 Gar Walls
Wall Library List I
Name
G1 R-13 BATT, R-3-0
G1 R-13 Gar Walls
Glazing
ue
15.12
*Sl Energy Solutions
Inspection Status
Results are projected
Surface Color Surface Area Location
Medium 549.0 ft' Unconditioned, attached garage
Name
BACK
Library Type Wall Assignment
U-.30. SHGC-.25 CONDiAMB
Foundation Wall
Assignment
Overhang Depth
0
Overhang Ft To
Tap
0
Overharjj Ft To
lJottom
0
Orientation
North
Surface Area
64.0 f12
BACK LEFT
U-.30. SHGC-.25
CONDIAMB
0
0
0
Northwest
65.0 ft2
BACK LEFT SLIDER
U-.30. SHGC-.25
CONDIAMB
0
0
0
Northwest
64.0 ft2
BACK RIGHT
U-.30, SHGC-25
CONDIAMB
0
0
0
Northeast
140.0 ft2
BACK RIGHT SLIDER
U-.30. SHGC-25
CONDIAMB
0
0
0
Northeast
64.0 ft2
FRONT
U-.30. SHGC-.25
CONDIAMB
0
0
0
South
76.0 ft2
FRONT BSMT
U-.30. SHGC-25
CONDIAMB FIN
0
0
0
South
15.0 ft'
FRONT RIGHT
U-.30. SHGC-25
CONDIAMB
0
0
0
Southeast
36.0 ft'
LEFT
U-.30. SHGC-25
CONDIAMB
0
0
0
West
35.0 ft2
RIGHT
U-.30. SHGC-.25
CONDIAMB
0
0
0
East
77.0 ft2
Glazing Library List
Name
U-.30. SHGC-.25
0.25
0.300
r
C
Building Summary
Property
11823 WEST RD
ZIONSVILLE. IN 46077
Model: FALCON
Community: WATERFRONTAT WEST CLAY 44
WWC044 (AS DESIGNED)
WATERFRONTAT WEST CLAY 44
Skylight
Skylight Library List
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PAUL SHOOPMAN HOME
BUILDING GROUP
None Present
Inspection Status
Results are projected
C"IEnergy Solutions
Opaque Door
Name Library Type Wall Assignment Foundatian Wall
Emittance
Solar
Surface Color
Surface Area
Location
Assignment
Absorptance
FRONT Wood Door CONDIAMB
0.9
0.75
Medium
24.0 fIl
Exposed Exterior
GARAGE FiberglasslSteel CONDIGAR
0.9
0.75
Medium
24.0 fI2
Exposed Exterior
Door
GARAGE FiberglasslSteel CONDIGAR
0.9
0.75
Medium
22.0 fI2
Exposed Exterior
Door
Opaque Door Library List
Name Effective U-factor
FiberglasslSteel Door 0.182
Wood Door 0.476
Roof Insulation
Name
MAIN R-38 Blown, GRt
3,754 No Medium 3.754.0 fI' Attic
4
Building Summary
Property
11823 WEST RD
ZIONSVILLE. IN 46077
Model: FALCON
Community: WATERFRONTAT WEST CLAY 44
WWC044 (AS DESIGNED)
WATERFRONTAT WEST CLAY 44
Roof Insulation Library List
Name Has
R-8 Blown, GRt
Whole House Infiltration
I nfiltration
SACH at 50 Pa
Mechanical Ventil;
JL
Ventilation Type
Exhaust Only
Organization Inspection Status
TSI Energy Solutions Results are projected
Devin Sielschott
Suilder
PAUL SHOOPMAN HOME
BUILDING GROUP
No 38.268
Blower -door tested
30
24
4
135
C"IEnergy Solutions
Yes
0
Lighting
% Interior Fluorescent / Interior LED Lighting I Exterior Fluorescent % Exterior LED Lighting Garage Fluorescent I Garage LED Lighting
Lighting Lighting Lighting
0 D 0 C 0
Gnsite Generation
None Present
Onsite Generation Library List
None Present
5
Building Summary
Property
11823 WEST RD
ZIONSVILLE. IN 46077
Model: FALCON
Community: WATERFRONTAT WEST CLAY 44
WWCO" (AS DESIGNED)
WATERFRONTAT WEST CLAY 44
Solar Generation
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PAUL SHOOPMAN HOME
BUILDING GROUP
Solar Generation Library List
None
Conditioning Equipment
Name Library Type
COOLING CA13MA048
HEATING 912SA481o0S21
Water Heating RG1PV50S'N
9
*Sl Energy Solutions
Inspection Status
Results are projected
ng vercent Joao Mot water vercent t_oao Locatron
0% 100% 0% Conditioned Space
100% 0%
Equipment Type: 912SA4810OS21 E
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
92.1 AFUE
Heating Capacity [kBtulh]
93
Use default EAE
No
EAE [kWh]
756
Equipment Type:
CA13NA048
Fuel Type
Electric
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Cooling Efficiency
13 SEER
Cooling Capacity [kBtulh]
45.5
0% 0%
0% Conditioned Space
100% Conditioned Space
Building Summary
Property
11823 WEST RD
ZIONSVILLE. IN 46077
Model: FALCON
Community: WATERFRONTAT WEST CLAY 44
WWCO" (AS DESIGNED)
WATERFRONTAT WEST CLAY 44
Organization
TSI Energy SClutions
Devin Sielschott
Builder
PAUL SHOOPMAN HOME
BUILDING GROUP
quipment Type: RG1 PV50S*N
Inspection Status
Results are projected
Fuel Type
Natural Gas
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.64 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulhl
40
Recovery Efficiency
0.80
r Distribution System
Distribution Type
Forced Air
Heating Equipment
HEATING
Cooling Equipment
COOLING
Sq. Feet Served
4484
# Return Grilles
4
Supply Duct R Value
10
Return Dud R Value
10
Supply Duct Area [ftq
1210.68
Return Dud Area [ftJ
896.8
Leakage to Outdoors
176 CFM25 (3.931 100 s.f.)
Total Leakage
352 CFM25
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Attic (well vented, under insulation)
Percent Supply Area
0
Percent Return Area
50
Duct 2
Duct Location
Conditioned Space
Percent Supply Area
100
Percent Return Area
50
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
rCeiling Fan
Has Ceiling Fan No
Cfm Per Watt 100
C"IEnergy Solutions
Building Summary
Property
11823 WEST RD
ZIONSVILLE. IN 46077
Model: FALCON
Community: WATERFRONTAT WEST CLAY 44
WWCO" (AS DESIGNED)
WATERFRONTAT WEST CLAY 44
Water Distribution
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PAUL SHOOPMAN HOME
BUILDING GROUP
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
45
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
10
Drain Water Heat Recovery?
No
Clothes Dryer
Fuel Type Electric
Cef 2.617
Field Utilization Timer Controls
INA
Label Energy Rating
704 kWh1Year
Electric Rate
$0.081kWh
Annual Gas Cost
$23.00
Gas Rate
$0.581Therm
Capacity
2.874
Imet
0.33053
ppliances and Controls
rogrammable thermostat?
Yes
ishwasher Size
Standard
ishwasher Efficiency
ID
270 kWhangefOven
Fuel
Electric
onvection Oven?
N❑
duction Range?
N❑
efrigerator Consumption
709 kVVhfYear
Inspection Status
Results are projected
C"IEnergy Solutions