Loading...
HomeMy WebLinkAboutGN010.0 - ENERGY CERTIFICATEIECC 2009 Performance Compliance P ro pe rty 11823 WEST RD ZIONSVILLE, IN 46077 Model: FALCON Community: WATERFRONTAT WE,' WWC044 (AS DESIGNED) WATERFRONTAT WEST CLAD 44 Organization TSI Energy Solutions Devin Sielschott Builder PAUL SHOOPMAN HOME BUILDING GROUP Design Heating Coaling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance S1,687 $296 $196 $2,180 $1,227 $0 $3,406 Requirements C"IEriergy Solutions As Designed $1,759 $212 $196 $2,167 $1,206 $0 $3,373 405.3 Performance -based compliance passes by D.6% ® R41)2.4.1.2 Air Leakage Testing Air sealing is 5.00 ACH at 50 Pa. It must not exceed 7.00 ACH at 5D Pa. 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration 1-1-Factor ® 4032.2 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 0.6%. Asa 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zane 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 9117119at1:07PM Ekotrope RATER - Version 3.1.0.2253 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 11823 WEST RD ZIONSVILLE, IN 46077 Builder: PAUL SHOOPMAN HOME BUILDING GROUP Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-10 Framed Floor NIA Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U-Value: 0.3, SHGC: 0.25 Building Features Duct Supply R-10.0, Return R-10.0 Duct Leakage to Outside 176 CFM25 (3.93 / 100 s.f.) Total Duct Leakage 352 CFM25 (Post -Construction) Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Natural Gas • 0.64 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports; I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party_ Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 9117f19 at 1:07 PM Ekotrope RATER - Version 3.1.0.2253 2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. Energy Code Inspection Checklist Property Organization 11823 WEST RD TSI Energy Solutions ZIONSVILLE, IN 46077 Devin Sielschott Model: FALCON Community: WATERFRONTAT WE: Builder PAULSHOOP MAN WWC044 (AS DESIGNED) HOME BUILDING WATER FRONT AT WEST CLAD 44 GROUP General Building Information Conditioned Area (sq ft) 4,484 Conditioned Volume (cubic ft) 57,294 Insulated Shell Area (sq ft) 12,462 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab ] Name: BSMT(730 s.f., 55 ft. exterior perimeter) R-0 perimeter insulation, R-0 under slab insulation. ] Name: CRAWL(3,024 s.f., 240 ft. exterior perimeter) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall ] Name: CON DIAMB FIN (Exterior Perimeter [ft]: 15, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 9.696 Fully insulated (top to bottom) ] Name: CON DIGAR (Exterior Perimeter [ft]: 40, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R-0 continuous insulation, R-0 cavity insulation Insulation Grade: I Fully insulated (top to bottom) ] Name: CRAWLIAMB (Exterior Perimeter [ft]: 225, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 3) R: 10.00 Fully insulated (top to bottom) ]l Name: CRAWLIGARAGE (Exterior Perimeter [ft]: 15, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 3) 1 R: 10.00 Fully insulated (top to bottom) Energy Code Inspection Checklist Property 11823 WEST RD ZIONSVILLE, IN 46077 Model: FALCON Community: WATERFRONT AT WE: WWC044 (AS DESIGNED) WATER FRONT AT WEST CLAD 44 Above Grade Wall Organization TSI Energy Solutions Devin Sielschott Builder PAULSHOOP MAN HOME BUILDING GROUP Name: COND/AMB (2,442 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CON DIGAR (549 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CONDIATTIC (213 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Name: CON DfAM B (240 s.f.) R: 13.575 El Name: CON DIGAR (55 s.f.) R: 13.575 Roof Name: MAIN (3,754 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (24 s.f.) U: 0.476 Name: GARAGE (24 s.f.) U: 0.182 Name: GARAGE (22 s.f.) U: 0.182 Inspection Status Results are projected C", Energy Solutions 2 Energy Code Inspection Checklist P ro pe rty 11823 WEST RD ZIONSVILLE, IN 46077 Model: FALCON Community: WATERFRONTAT WE,' WWC044 (AS DESIGNED) WATERFRONTAT WEST CLAD 44 Glazing Organization TSI Energy Solutions Devin Sielschott Builder PAUL SHOOPMAN HOME BUILDING GROUP Inspection Status Results are projected Name: FRONT (76 s.f.), U: 0.300, SHGC: 0.25, Orientation: SOUTH 11 Name: FRONT RIGHT (36 s.f.), U: 0.300, SHGC: 0.25, Orientation: SOUTH—EAST 11 Name: BACK (64 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH Name: BACK LEFT (85 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH—WEST M Name: BACK LEFT SLIDER (64 s.f.), U: 0.300, SiHGC: 0.25, Orientation: NORTH—WEST E] Name: BACK RIGHT (140 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH—EAST CTMEnergy Solutions Name: BACK RIGHT SLIDER (64 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH—EAST E] Name: LEFT (35 s.f.), U: 0.300, SHGC: 0.25, Orientation: WEST El Name: RIGHT (77 s.f.), U: 0.300, SHGC: 0.25, Orientation: EAST [] Name: FRONT BSMT (15 s.f.), U: 0.300, SHGC: 0.25, Orientation: SOUTH Skylight None Present Mechanical Ventilation ElMechanical ventilation system rated for, and capable of, providing continuous ventilation. System shall include automatic timing controls. System type: Exhaust Only, 24 hrslday, 13.5 Watts. Mechanical Equipment 3 a -A HEATING • Natural Gas • 100% Heating Load @ 92.1 AFUE Energy Code Inspection Checklist Property Organization 11823 WEST RD TSI Energy Solutions ZIONSVILLE, IN 46077 Devin Sielschott Model: FALCON Community: WATERFRONT AT WE: Builder PAULSHOOP MAN WWC044 (AS DESIGNED) HOME BUILDING WATER FRONT AT WEST CLAD 44 GROUP COOLING • Electric- 100% Cooling Load @ 13 SEER inspection Status Results are projected E] Water Heating • Natural Gas • 100% Hot Water Load @ 0.64 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 4,775 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Leakage to Outside specified as: 176 CFM25 (3.93 / 100 s.f.) Total Leakage specified as: 352 CFM25 (Post -Construction) Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM251 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage a= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. 4 Energy Code Inspection Checklist Property 11823 WEST RD ZIONSVILLE, IN 46077 Model: FALCON Community: WATERFRONTAT WE: WWC044 (AS DESIGNED) WATER FRONT AT WEST CLAD 44 Project Notes Organization TSI Energy Solutions Devin Sielschott Builder PAULSHOOP MAN HOME BUILDING GROUP inspection Status Results are projected C", Energy Solutions Building Summary Property Organization Inspection Status *Sl Energy Solutions 11823 WEST RD TSI Energy Solutions Results are projected ZIONSVILLE. IN 46077 Devin Sielschott Model: FALCON Community: WATERFRONTAT WEST CLAY 44 Builder PAUL SHOOPMAN HOME WWCO" (AS DESIGNED) BUILDING GROUP WATERFRONTAT WEST CLAY 44 General Building Information Number Of Bedrooms 4 Number Of Floors 1 Conditioned Floor Area [sq. ft.] 4,484 Unconditioned; attached garage? Yes Conditioned Volume [cu. ft.] 57,294 Total Units in Building 1 Residence Type Single family detached Floor Number Model FALCON Community WATERFRONT AT WEST CLAY 44 Climate Zone 5A Foundation Wall Name Library type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB FIN R-11 Finished, G1 1 8 15 Exposed Exterior Conditioned Space CONDIGAR Uninsulated 1 8 40 Exposed Exterior Conditioned Space CRAWLIAMB R-10 Draped, Full 1 3 225 Exposed Exterior Conditioned Crawlspace CRAWLIGARAGE R-10 Draped, Full 1 3 15 Exposed Exterior Conditioned Crawlspace Foundation Wall Library List W Name Feet From Wall Top To Feet From Wall Top To Is Fully Insulated Continuous R-value Cavity R-value Effective Insulation R- Continuous Insulation Continuous Insulation value Top Bottom R-10 Draped, Full NIA NIA Yes NIA NIA 10.00 R-11 Finished, G1 NIA NIA Yes NIA NIA 9.696 Uninsulated NIA NIA Yes 0.00 NIA NIA Slab Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 55 Below Grade 123 0 730.0 ft' Exposed Exterior Conditioned Space CRAWL Uninsulated 240 Below Grade 123 0 3,024.0 ft' Exposed Exterior Conditioned Crawlspace 1 Building Summary Property Organization Inspection Status 11823 WEST RD TSI Energy Solutions Results are projected ZIONSVILLE. IN 46077 Devin Sielschott Model: FALCON Community: WATERFRONTAT WEST CLAY 44 Builder PAUL SHOOPMAN HOME WWC044 (AS DESIGNED) BUILDING GROUP WATERFRONTAT WEST CLAY 44 Slab Library List Name Wall Construction Slab Completel�r Underslab Perimeter Perimeter Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value Uninsulated Woad Frame 1 Other No ❑ 0 ❑ Framed Floor None Present Framed Floor Library List None Present Rim Joist Name CONDIAMB CO N DIGAR Rim Joist Library List Name G1 R-13, R-3.0 all Name CONDIAMB CONDIATTIC C"IEnergy Solutions No 0.00 Library Type Surface Area Location G1 R-13, R-3.0 240.0 ft' Exposed Exterior G1 R-13, R3.0 55.0 ft' Unconditioned, attached garage sulation R-value 13.575 G1 R-13 BATT, P3-0 Medium 2,442.0 ft' Exposed Exterior G1 R-13 BATT R3.0 Medium 213.0 ft' Attic Building Summary Property Organization 11823 WEST RD TSI Energy Solutions ZIONSVILLE. IN 46077 Devin Sielschott Model: FALCON Community: WATERFRONTAT WEST CLAY 44 Builder PAUL SHOOPMAN HOME WWC044 (AS DESIGNED) BUILDING GROUP WATERFRONTAT WEST CLAY 44 Name Library Type CONDIGAR G1 R-13 Gar Walls Wall Library List I Name G1 R-13 BATT, R-3-0 G1 R-13 Gar Walls Glazing ue 15.12 *Sl Energy Solutions Inspection Status Results are projected Surface Color Surface Area Location Medium 549.0 ft' Unconditioned, attached garage Name BACK Library Type Wall Assignment U-.30. SHGC-.25 CONDiAMB Foundation Wall Assignment Overhang Depth 0 Overhang Ft To Tap 0 Overharjj Ft To lJottom 0 Orientation North Surface Area 64.0 f12 BACK LEFT U-.30. SHGC-.25 CONDIAMB 0 0 0 Northwest 65.0 ft2 BACK LEFT SLIDER U-.30. SHGC-.25 CONDIAMB 0 0 0 Northwest 64.0 ft2 BACK RIGHT U-.30, SHGC-25 CONDIAMB 0 0 0 Northeast 140.0 ft2 BACK RIGHT SLIDER U-.30. SHGC-25 CONDIAMB 0 0 0 Northeast 64.0 ft2 FRONT U-.30. SHGC-.25 CONDIAMB 0 0 0 South 76.0 ft2 FRONT BSMT U-.30. SHGC-25 CONDIAMB FIN 0 0 0 South 15.0 ft' FRONT RIGHT U-.30. SHGC-25 CONDIAMB 0 0 0 Southeast 36.0 ft' LEFT U-.30. SHGC-25 CONDIAMB 0 0 0 West 35.0 ft2 RIGHT U-.30. SHGC-.25 CONDIAMB 0 0 0 East 77.0 ft2 Glazing Library List Name U-.30. SHGC-.25 0.25 0.300 r C Building Summary Property 11823 WEST RD ZIONSVILLE. IN 46077 Model: FALCON Community: WATERFRONTAT WEST CLAY 44 WWC044 (AS DESIGNED) WATERFRONTAT WEST CLAY 44 Skylight Skylight Library List Organization TSI Energy Solutions Devin Sielschott Builder PAUL SHOOPMAN HOME BUILDING GROUP None Present Inspection Status Results are projected C"IEnergy Solutions Opaque Door Name Library Type Wall Assignment Foundatian Wall Emittance Solar Surface Color Surface Area Location Assignment Absorptance FRONT Wood Door CONDIAMB 0.9 0.75 Medium 24.0 fIl Exposed Exterior GARAGE FiberglasslSteel CONDIGAR 0.9 0.75 Medium 24.0 fI2 Exposed Exterior Door GARAGE FiberglasslSteel CONDIGAR 0.9 0.75 Medium 22.0 fI2 Exposed Exterior Door Opaque Door Library List Name Effective U-factor FiberglasslSteel Door 0.182 Wood Door 0.476 Roof Insulation Name MAIN R-38 Blown, GRt 3,754 No Medium 3.754.0 fI' Attic 4 Building Summary Property 11823 WEST RD ZIONSVILLE. IN 46077 Model: FALCON Community: WATERFRONTAT WEST CLAY 44 WWC044 (AS DESIGNED) WATERFRONTAT WEST CLAY 44 Roof Insulation Library List Name Has R-8 Blown, GRt Whole House Infiltration I nfiltration SACH at 50 Pa Mechanical Ventil; JL Ventilation Type Exhaust Only Organization Inspection Status TSI Energy Solutions Results are projected Devin Sielschott Suilder PAUL SHOOPMAN HOME BUILDING GROUP No 38.268 Blower -door tested 30 24 4 135 C"IEnergy Solutions Yes 0 Lighting % Interior Fluorescent / Interior LED Lighting I Exterior Fluorescent % Exterior LED Lighting Garage Fluorescent I Garage LED Lighting Lighting Lighting Lighting 0 D 0 C 0 Gnsite Generation None Present Onsite Generation Library List None Present 5 Building Summary Property 11823 WEST RD ZIONSVILLE. IN 46077 Model: FALCON Community: WATERFRONTAT WEST CLAY 44 WWCO" (AS DESIGNED) WATERFRONTAT WEST CLAY 44 Solar Generation Organization TSI Energy Solutions Devin Sielschott Builder PAUL SHOOPMAN HOME BUILDING GROUP Solar Generation Library List None Conditioning Equipment Name Library Type COOLING CA13MA048 HEATING 912SA481o0S21 Water Heating RG1PV50S'N 9 *Sl Energy Solutions Inspection Status Results are projected ng vercent Joao Mot water vercent t_oao Locatron 0% 100% 0% Conditioned Space 100% 0% Equipment Type: 912SA4810OS21 E Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 92.1 AFUE Heating Capacity [kBtulh] 93 Use default EAE No EAE [kWh] 756 Equipment Type: CA13NA048 Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 45.5 0% 0% 0% Conditioned Space 100% Conditioned Space Building Summary Property 11823 WEST RD ZIONSVILLE. IN 46077 Model: FALCON Community: WATERFRONTAT WEST CLAY 44 WWCO" (AS DESIGNED) WATERFRONTAT WEST CLAY 44 Organization TSI Energy SClutions Devin Sielschott Builder PAUL SHOOPMAN HOME BUILDING GROUP quipment Type: RG1 PV50S*N Inspection Status Results are projected Fuel Type Natural Gas Distribution Type Hydronic Delivery Hot Water Efficiency 0.64 Energy Factor Tank Capacity (gal.) 50 Hot Water Capacity [kBtulhl 40 Recovery Efficiency 0.80 r Distribution System Distribution Type Forced Air Heating Equipment HEATING Cooling Equipment COOLING Sq. Feet Served 4484 # Return Grilles 4 Supply Duct R Value 10 Return Dud R Value 10 Supply Duct Area [ftq 1210.68 Return Dud Area [ftJ 896.8 Leakage to Outdoors 176 CFM25 (3.931 100 s.f.) Total Leakage 352 CFM25 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Attic (well vented, under insulation) Percent Supply Area 0 Percent Return Area 50 Duct 2 Duct Location Conditioned Space Percent Supply Area 100 Percent Return Area 50 Duct 3 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ rCeiling Fan Has Ceiling Fan No Cfm Per Watt 100 C"IEnergy Solutions Building Summary Property 11823 WEST RD ZIONSVILLE. IN 46077 Model: FALCON Community: WATERFRONTAT WEST CLAY 44 WWCO" (AS DESIGNED) WATERFRONTAT WEST CLAY 44 Water Distribution Organization TSI Energy Solutions Devin Sielschott Builder PAUL SHOOPMAN HOME BUILDING GROUP Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 45 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 10 Drain Water Heat Recovery? No Clothes Dryer Fuel Type Electric Cef 2.617 Field Utilization Timer Controls INA Label Energy Rating 704 kWh1Year Electric Rate $0.081kWh Annual Gas Cost $23.00 Gas Rate $0.581Therm Capacity 2.874 Imet 0.33053 ppliances and Controls rogrammable thermostat? Yes ishwasher Size Standard ishwasher Efficiency ID 270 kWhangefOven Fuel Electric onvection Oven? N❑ duction Range? N❑ efrigerator Consumption 709 kVVhfYear Inspection Status Results are projected C"IEnergy Solutions