HomeMy WebLinkAboutCOP 026 - Energy Certificate13005 COPPER RUN BLVD
CARMEL, IN 46074
Builder: PULTE HOMES
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls R-11
Framed Floor R-38
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 5 ACH50
Window U-Value: 0.31, SHGC: 0.28
Building Features
Duct Supply R-30.0, Return R-30.0
Duct Leakage to Outside 300 CFM25 (4.941100 s.f.)
Total Duct Leakage 480 CFM25 (Post -Construction)
Heating Furnace • Natural Gas • 93 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the I ECC or will be verified as such by another party.
Name
Michael Hill
Organization: TSI Energy Solutions
Signature:
Date:
9/9119 at 3:38 PM
Ekotrope RATER - Version 3.1.0.2247
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.