SITE UTILITY PLAN
30'0 30' THIS DOCUMENT HAS BEEN PREPARED BY PROGRESSIVE AE AS AN INSTRUMENT OF SERVICE, AND PROGRESSIVE AESHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO.
ISSUANCES
REVISIONS
If this document is sealed and signed in a digital
or electronic format and is received from someone
other than the sealing professional identified in
the document, you must contact the sealing
professional in writing to validate authenticity of
the document. The sealing professional disclaims
the seal and signature and shall not be liable for
any liability associated with it where the
authenticity of any digital or electronic seal or
signature has not been validated in this manner.
NO. DATE DESCRIPTION
8/2/2019 12:12:11 PMP:\70050012\WIP DRAWINGS\C4 - SITE UTILITY.dwg shortj1811 4 Mile Rd NE Grand Rapids, MI 49525 616.361.2664 www.progressiveae.com
DRAWN BY
PROFESSIONAL
PROJECT MANAGER
FILE NUMBER
CHECKED BYCHRISTIAN BROTHERS AUTOMOTIVEPROPOSED SERVICECENTER10860 N MICHIGAN ROAD, ZIONSVILLE, IN 46077 70050012
JPM
BIDS
07/25/2019
R
E
D
D
R
D
.
C4
SITE UTILITY
PLAN
JRS
70050012
CALL 811 NOTE:
www.CALL811.com
CONTRACTOR TO CONTACT 811
SERVICE AT LEAST 3 WORKING
DAYS PRIOR TO CONSTRUCTION,
TO CONFIRM LOCATION OF
EXISTING UTILITIES. DIAL 811.
PROPOSED
CHRISTIAN BROTHERS AUTOMOTIVE
FI NI SHED FLOOR ELEV = 9 01.75 MICHIGAN ROAD (US-421)1.5" WATERMAIN TAP
1.5" CURB STOP
DIRCTIONALLY DRILL
ELECTRICAL SERVICE
(BY DUKE ENERGY)
GAS MAIN TAP
5'x5" TRANSFORMER
PAD, ENSURE 10' CLEAR
SURROUNDING
TRANSFORMER
ELECTRIC
SERVICE SANITARY SEWER NOTES
1. CONTRACTOR SHALL OBTAIN PERMIT TO CONNECT TO SANITARY SYSTEM
FROM THE CITY OF CARMEL AND TRI CO SEWER UTILITY.
2. SANITARY SEWER TO COMPLY WITH TRI CO SEWER UTILITY SANITARY
SEWER SPECIFICATIONS.
3. CLEANOUTS TO BE PROVIDED WITHIN 5 FEET OF THE BUILDING EXTERIOR
WALL ON ALL LATERALS EXITING THE BUILDING.
4. SANITARY SEWER LATERALS WITHIN SITE SHALL BE (ASTM D-3034) SDR 35.
5. ROOF DRAINS, FOUNDATION DRAINS, AND OTHER CLEAN WATER
CONNECTIONS TO THE SANITARY SEWER ARE PROHIBITED.
6. OIL / WATER SEPARATOR TO BE 1000 GALLON 3 COMPARTMENT AND
COMPLY WITH TRICO SEWER UTILITY SPECIFICATIONS.
WATER SERVICE NOTES
1. INSTALL WATER SERVICE WITH MINIMUM 5.0' OF COVER TO TOP OF PIPE.
2. PROVIDE A MINIMUM 18" OF VERTICAL SEPARATION AND 10' OF HORIZONTAL
SEPARATION BETWEEN WATER SERVICE AND ALL SANITARY AND STORM
SEWERS.
3. WATER SERVICE MATERIAL AND INSTALLATION SHALL BE PERFORMED IN
ACCORDANCE WITH CITIZENS ENERGY GROUP WATER DEPARTMENT
SPECIFICATIONS.
4. 2" AND SMALLER DOMESTIC WATER SERVICE SHALL BE TYPE K COPPER
PIPE.
5. COORDINATE WATER TAPS WITH CITY OF CARMEL AND CITIZENS ENERGY
GROUP WATER DEPARTMENT.
6. 1.5" WATER SERVICE TO SPLIT INSIDE THE BUILDING TO 1" DOMESTIC
SERVICE AND 1" IRRIGATION SERVICE WITH SEPARATE 3
4" METERS.
PROPOSED
WATERMAIN
EASEMENT
16" WATERMAIN
EXTENSION (BY OTHERS)
1.5" WATER
SERVICE
PROPOSED
HYDRANT ASSEMBLY
6" VALVE & BOX
8"x6" REDUCER
370 LF 8" WM
TO HYDRANT
2
0
'
PROPOSED
SANITARY SEWER
EASEMENT (BY OTHERS)
6" SAN
IE=897.50 6" SAN
IE=897.50
6"x6" WYE
IE =897.00
232 LF OF 6" SAN
@ 2.1%
4' DIA SAN MH'
(BY OTHERS)
RIM = 898.50
N IE = 891.48
SW IE = 891.58
8" SAN
(BY OTHERS)
67 LF OF 6"
SAN @1.0%
OI L/WATER SEPERATOR,
1000 GAL, REFER TO
PLUMBI NG PLANS AND
DETAI LS
CLEANOUT
6" IE = 892.12
GENERAL NOTES
1. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE
RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS
REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH
PROPOSED DEVELOPMENT SHALL BE THE DEVELOPER TO RESOLVE WITH
THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO
WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE.
2. CONTRACTOR TO COORDINATE WITH DUKE ENERGY FOR ELECTRICAL
SERVICE TO TRANSFORMER. DUKE ENERGY TO ACQUIRE INDOT ROW
PERMIT AND PROVIDE ELECTRICAL SERVICE TO THE TRANSFORMER,
INCLUDING DIRECTIONAL DRILLING ACROSS US-421.
3. NATURAL GAS UTILITY COMPANY TO EXTEND GAS MAIN FROM THE NORTH
TO THE SOUTH ALONG REDD ROAD. GAS SERVICE FOR CHRISTIAN
BROTHERS SITE TO TAP THIS GAS MAIN AFTER EXTENSION WORK IS
COMPLETE, COORDINATE WITH NATURAL GAS COMPANY.
4. ALL IMPROVEMENTS AND UTILITIES IN REDD ROAD ROW OR NOTED "BY
OTHERS" IS NOT IN THE CHRISTIAN BROTHERS CONTRACT. REDD ROAD
PLANS TO BE PERMITTED BY WOOLPERT. COORDINATE CONSTRUCTION
WITH REDD ROAD CONTRACTOR.
CONSTRUCTION
LIMITS
24" SAMPLE STRUCTURE,
REFER TO PLUMBING PLANS
AND DETAILS8"x6" WYE
6" IE = ±891.45
(BY OTHERS)
GAS SERVICE LINE
GAS MAIN EXTENSION,
BY UTILITY COMPANY
(NOT IN CONTRACT)
10' PRIVATE
UTILITY EASEMENT
1 0'
GAS
METER
AC CONDENSER
WATER METERSELECTRIC
METER
8" WM TAPPING
SLEEVE AND VALVE
2 0'
JPM56' ROW10/07/19