Loading...
HomeMy WebLinkAboutC040.0_UTILITY_PLANFUTURE BUILDING 3,500 SF FUTURE BUILDING 4,000 SF 24 9 1.70 ACRES XX X XX GG GG G GWEST LINE SW 1/4 SEC 6, T17N, R3E HAMILTON COUNTY 78.69'OHE OHE OHE OHE OHE OHE OHE OHE OHE OHEOHE OHETEMPORARY SITE BENCHMARK 2 SANITARY SEWER FORCE MAIN SIGN E UGE UGE U GE UGE UGE U GE UGE TX WW COTYPE 2 CO TYPE 2 CO TYPE 2 CO TYPE 2 G COTYPE 2 CO COGG GG G GGG G G GGG GG GG G CO CO CO CO TYPE 2 W W WW1"= SITE UTILITY PLAN 30'0 30' THIS DOCUMENT HAS BEEN PREPARED BY PROGRESSIVE AE AS AN INSTRUMENT OF SERVICE, AND PROGRESSIVE AESHALL RETAIN ALL COMMON LAW, STATUTORY AND OTHER RESERVED RIGHTS, INCLUDING THE COPYRIGHT THERETO. ISSUANCES REVISIONS If this document is sealed and signed in a digital or electronic format and is received from someone other than the sealing professional identified in the document, you must contact the sealing professional in writing to validate authenticity of the document. The sealing professional disclaims the seal and signature and shall not be liable for any liability associated with it where the authenticity of any digital or electronic seal or signature has not been validated in this manner. NO. DATE DESCRIPTION 8/2/2019 12:12:11 PMP:\70050012\WIP DRAWINGS\C4 - SITE UTILITY.dwg shortj1811 4 Mile Rd NE Grand Rapids, MI 49525 616.361.2664 www.progressiveae.com DRAWN BY PROFESSIONAL PROJECT MANAGER FILE NUMBER CHECKED BYCHRISTIAN BROTHERS AUTOMOTIVEPROPOSED SERVICECENTER10860 N MICHIGAN ROAD, ZIONSVILLE, IN 46077 70050012 JPM BIDS 07/25/2019 R E D D R D . C4 SITE UTILITY PLAN JRS 70050012 CALL 811 NOTE: www.CALL811.com CONTRACTOR TO CONTACT 811 SERVICE AT LEAST 3 WORKING DAYS PRIOR TO CONSTRUCTION, TO CONFIRM LOCATION OF EXISTING UTILITIES. DIAL 811. PROPOSED CHRISTIAN BROTHERS AUTOMOTIVE FI NI SHED FLOOR ELEV = 9 01.75 MICHIGAN ROAD (US-421)1.5" WATERMAIN TAP 1.5" CURB STOP DIRCTIONALLY DRILL ELECTRICAL SERVICE (BY DUKE ENERGY) GAS MAIN TAP 5'x5" TRANSFORMER PAD, ENSURE 10' CLEAR SURROUNDING TRANSFORMER ELECTRIC SERVICE SANITARY SEWER NOTES 1. CONTRACTOR SHALL OBTAIN PERMIT TO CONNECT TO SANITARY SYSTEM FROM THE CITY OF CARMEL AND TRI CO SEWER UTILITY. 2. SANITARY SEWER TO COMPLY WITH TRI CO SEWER UTILITY SANITARY SEWER SPECIFICATIONS. 3. CLEANOUTS TO BE PROVIDED WITHIN 5 FEET OF THE BUILDING EXTERIOR WALL ON ALL LATERALS EXITING THE BUILDING. 4. SANITARY SEWER LATERALS WITHIN SITE SHALL BE (ASTM D-3034) SDR 35. 5. ROOF DRAINS, FOUNDATION DRAINS, AND OTHER CLEAN WATER CONNECTIONS TO THE SANITARY SEWER ARE PROHIBITED. 6. OIL / WATER SEPARATOR TO BE 1000 GALLON 3 COMPARTMENT AND COMPLY WITH TRICO SEWER UTILITY SPECIFICATIONS. WATER SERVICE NOTES 1. INSTALL WATER SERVICE WITH MINIMUM 5.0' OF COVER TO TOP OF PIPE. 2. PROVIDE A MINIMUM 18" OF VERTICAL SEPARATION AND 10' OF HORIZONTAL SEPARATION BETWEEN WATER SERVICE AND ALL SANITARY AND STORM SEWERS. 3. WATER SERVICE MATERIAL AND INSTALLATION SHALL BE PERFORMED IN ACCORDANCE WITH CITIZENS ENERGY GROUP WATER DEPARTMENT SPECIFICATIONS. 4. 2" AND SMALLER DOMESTIC WATER SERVICE SHALL BE TYPE K COPPER PIPE. 5. COORDINATE WATER TAPS WITH CITY OF CARMEL AND CITIZENS ENERGY GROUP WATER DEPARTMENT. 6. 1.5" WATER SERVICE TO SPLIT INSIDE THE BUILDING TO 1" DOMESTIC SERVICE AND 1" IRRIGATION SERVICE WITH SEPARATE 3 4" METERS. PROPOSED WATERMAIN EASEMENT 16" WATERMAIN EXTENSION (BY OTHERS) 1.5" WATER SERVICE PROPOSED HYDRANT ASSEMBLY 6" VALVE & BOX 8"x6" REDUCER 370 LF 8" WM TO HYDRANT 2 0 ' PROPOSED SANITARY SEWER EASEMENT (BY OTHERS) 6" SAN IE=897.50 6" SAN IE=897.50 6"x6" WYE IE =897.00 232 LF OF 6" SAN @ 2.1% 4' DIA SAN MH' (BY OTHERS) RIM = 898.50 N IE = 891.48 SW IE = 891.58 8" SAN (BY OTHERS) 67 LF OF 6" SAN @1.0% OI L/WATER SEPERATOR, 1000 GAL, REFER TO PLUMBI NG PLANS AND DETAI LS CLEANOUT 6" IE = 892.12 GENERAL NOTES 1. UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 2. CONTRACTOR TO COORDINATE WITH DUKE ENERGY FOR ELECTRICAL SERVICE TO TRANSFORMER. DUKE ENERGY TO ACQUIRE INDOT ROW PERMIT AND PROVIDE ELECTRICAL SERVICE TO THE TRANSFORMER, INCLUDING DIRECTIONAL DRILLING ACROSS US-421. 3. NATURAL GAS UTILITY COMPANY TO EXTEND GAS MAIN FROM THE NORTH TO THE SOUTH ALONG REDD ROAD. GAS SERVICE FOR CHRISTIAN BROTHERS SITE TO TAP THIS GAS MAIN AFTER EXTENSION WORK IS COMPLETE, COORDINATE WITH NATURAL GAS COMPANY. 4. ALL IMPROVEMENTS AND UTILITIES IN REDD ROAD ROW OR NOTED "BY OTHERS" IS NOT IN THE CHRISTIAN BROTHERS CONTRACT. REDD ROAD PLANS TO BE PERMITTED BY WOOLPERT. COORDINATE CONSTRUCTION WITH REDD ROAD CONTRACTOR. CONSTRUCTION LIMITS 24" SAMPLE STRUCTURE, REFER TO PLUMBING PLANS AND DETAILS8"x6" WYE 6" IE = ±891.45 (BY OTHERS) GAS SERVICE LINE GAS MAIN EXTENSION, BY UTILITY COMPANY (NOT IN CONTRACT) 10' PRIVATE UTILITY EASEMENT 1 0' GAS METER AC CONDENSER WATER METERSELECTRIC METER 8" WM TAPPING SLEEVE AND VALVE 2 0' JPM56' ROW10/07/19