Loading...
HomeMy WebLinkAboutG2 - Site PlanP2P2P2P2P2P2P2P2P2P2P2P2P2P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P1 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P4P4P3P3P4P4P3P3P4P4P3P3 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 117 118 120 121 122 115 116 114 113112 111 110 109 108 107 104103 101 102 100 124PROPOSED 50' DRAINAGE& UTILITY EASEMENTFUTURE SOCCER FIELD 7'5'7'10.3'5'5'8'R31' R5' R6' R6' R3' R6' R6' R6' R3' R3'R1 5 ' R3' R26 ' R3' 1 1 1 1 1 1 11 10 10 4 4 4 9 8 5 10 10 1010 10 10 13 12 10 1313 13 13 13 88888 13 13 1414 14 14 15 15 15 15 15 15 15 15 15 15 15 16 5 5 13 23 22 21 21 21 21 10 23 17 17 17 13 6'53.2' 19'25'19'19'25'31' 28.4'28'134'390'442'344'25'25'25'12'19'22.3'31 SPACES @ 9'-0" = 279'20'18'8 SPACES @ 9'-0" = 72'19'25'19'19'25'25'19'20'9'8'5'2@ 8'= 16'8'3 @ 9' = 27' 14'12 SPACES @ 9'-0" = 108'18'9'9' TYP. 23 23 R26' 20 19 19 18 19 40.8'10'25 5 24 CONSTRUCTION LIMITS 7 8 7 8 14 GENERAL NOTES 1.SEE SHEET G0.1 FOR GENERAL NOTES, LEGEND AND ABBREVIATIONS. 2.REFER TO SURVEY SHEET FOR BOUNDARY AND TOPOGRAPHIC SURVEY INFORMATION. 3.REFER TO LANDSCAPE PLANS FOR PLANTINGS. 4.DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED /REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 5.ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF=WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY. KEYNOTES ASPHALT PAVEMENT - SEE DETAIL A ON SHEET G6.1 ASPHALT TO ASPHALT INTERFACE - SEE DETAIL D ON SHEET G6.1 SAWCUT EXISTING EDGE OF ASPHALT MONOLITHIC CURB & WALK - SEE DETAIL G ON SHEET G6.1 CONCRETE CURB - SEE DETAIL J ON SHEET G6.1 EXPANSION JOINT w/SEALANT- SEE DETAIL E ON SHEET G6.1 (TYP.) CONTROL JOINT - SEE DETAIL C & I ON SHEET G6.1 (TYP.) HVAC UNIT PAD - SEE DETAIL H ON SHEET G6.1 TRANSFORMER PAD - SEE DETAIL H ON SHEET G6.1 LANDSCAPE AREA - SEE LANDSCAPE PLAN DETENTION POND - SEE GRADING PLAN DUMPSTER ENCLOSURE - SEE ARCHITECTURAL PLANS LIGHT POLE - SEE ELECTRICAL PLANS ASPHALT PATH - SEE DETAIL A ON SHEET G6.1 CONCRETE STOOP - SEE DETAIL F ON SHEET G6.1 CONCRETE BOLLARD - SEE DETAIL B ON SHEET G6.2 4" WIDE WHITE LINE (TYPICAL) 4" WIDE BLUE LINE (TYPICAL) 4" WIDE BLUE LINES @ 2'-0" O.C. DIAGONALLY - SEE DETAIL P ON SHEET G6.1 PAINTED ADA SYMBOL - SEE DETAIL O ON SHEET G6.1 (TYP.) ADA PARKING SIGN (TYPICAL AT EACH ADA PARKING SPACE) - SEE DETAIL N ON SHEET G6.1 PRECAST PARKING BUMPER - SEE DETAIL L ON SHEET G6.1 TAPER CURB - SEE DETAIL K ON SHEET G6.1 ADA RAMP - SEE DETAIL Q ON SHEET G6.1 BICYCLE RACK - SEE DETAIL H ON SHEET L1.3 10' WIDE MULTIUSE PATH. SEE DETAIL R ON SHEET G6.1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what's below. before you dig.Call R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! LEGEND NEW BUILDING NEW ASPHALT PAVEMENT NEW CONCRETE SIDEWALK PARKING SUMMARY - PROJECT AREA STANDARD PARKING SPACES 330 ADA PARKING SPACES EXISTING 0 PROPOSED TOTAL PARKING SPACES TOTAL 118 5 5 448 SURFACE AREA SUMMARY IMPERVIOUS AREA ADDED IMPERVIOUS AREAS 1.53 ACRE TOTAL AREA PERVIOUS AREAS EXISTING PERCENTAGE IMPERVIOUS AREA DEVELOPED (BUILDINGS, PAVEMENT, SIDEWALK) (LAWN, LANDSCAPE, STONE, PLAYGROUND) 6.02 ACRE 11.74 ACRE 5.02 ACRE 13.27 ACRE 4.49 ACRE 11.5%54.5% 11.04 ACRE NEW BUILDING 152,240 SFT. MATCH LINE - SEE SHEET G2.2 BUILD LIMIT LINE - EDGE OF TREELINE AND SLOPE PLANNORTHN WS ECOPYRIGHT 2019 BY FANNING/HOWEY ASSOCIATES, INC. WWW.FHAI.COM ARCHITECT CONSULTANT 6/13/2019 3:21:38 PM\\data1\citrixprofiles$\amiller\My Documents\218052.00_ARCH_amiller.rvtPROJECT NUMBER: 2019199.00 INDOOR FACILITY AT BADGER FIELDS CLAY TOWNSHIP 5459 E MAIN STREET CARMEL, INDIANA PROJECT ISSUE DATE: August 23, 2019 DRAWN BY: MTP REV. NO.DESCRIPTION DATE 11300453 SOI STATE OF ORPF E S NEER N LA E N GIANAINIDER DAHC I IG S No. TERE D A CNIK.N DTAC COMMENTS 09/06/20191 SITE LAYOUT PLAN G2.1 SITE LAYOUT PLAN SCALE: 1"= 40'N 40 12004080