HomeMy WebLinkAboutG2 - Site PlanP2P2P2P2P2P2P2P2P2P2P2P2P2P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1
P1 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P3 P2 P2
P2
P2
P2
P2
P2
P2
P2
P2
P2
P2
P2
P2
P2
P2
P2
P4P4P3P3P4P4P3P3P4P4P3P3
P2
P2
P2
P2
P2
P2
P2
P2
P2
P2
P2
P2
117 118 120
121
122
115 116
114
113112
111
110
109
108
107
104103
101 102
100
124PROPOSED 50' DRAINAGE& UTILITY EASEMENTFUTURE SOCCER FIELD
7'5'7'10.3'5'5'8'R31'
R5'
R6'
R6'
R3'
R6'
R6'
R6'
R3'
R3'R1
5
'
R3'
R26
'
R3'
1
1
1
1
1 1
11
10
10
4
4
4
9
8
5
10
10
1010
10
10
13
12
10
1313
13 13 13
88888
13
13
1414
14
14
15
15 15
15 15
15
15
15
15
15 15
16
5
5 13
23
22
21
21
21
21
10
23
17
17
17
13
6'53.2'
19'25'19'19'25'31'
28.4'28'134'390'442'344'25'25'25'12'19'22.3'31 SPACES @ 9'-0" = 279'20'18'8 SPACES @ 9'-0" = 72'19'25'19'19'25'25'19'20'9'8'5'2@ 8'= 16'8'3 @ 9' = 27'
14'12 SPACES @ 9'-0" = 108'18'9'9'
TYP.
23
23
R26'
20
19
19
18
19
40.8'10'25
5
24
CONSTRUCTION LIMITS
7
8
7
8
14
GENERAL NOTES
1.SEE SHEET G0.1 FOR GENERAL NOTES, LEGEND AND
ABBREVIATIONS.
2.REFER TO SURVEY SHEET FOR BOUNDARY AND TOPOGRAPHIC
SURVEY INFORMATION.
3.REFER TO LANDSCAPE PLANS FOR PLANTINGS.
4.DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED
/REPAIRED TO THE SATISFACTION OF THE CITY AT THE
COMPLETION OF THE PROJECT. THE CONTRACTOR IS
ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY
PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE
EXISTING CONDITION OF THE RIGHT-OF-WAY.
5.ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY
RIGHT-OF=WAY SHALL CONFORM TO THE REQUIREMENTS OF THE
DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL
CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A
PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S
CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION
REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES
OF THE WORK AND TO REVIEW THE AUTHORITY OF THE
DEPARTMENT AS IT RELATES TO WORK AND TO REVIEW THE
AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN
THE EXISTING AND PROPOSED RIGHT-OF-WAY.
KEYNOTES
ASPHALT PAVEMENT - SEE DETAIL A ON SHEET G6.1
ASPHALT TO ASPHALT INTERFACE - SEE DETAIL D ON SHEET G6.1
SAWCUT EXISTING EDGE OF ASPHALT
MONOLITHIC CURB & WALK - SEE DETAIL G ON SHEET G6.1
CONCRETE CURB - SEE DETAIL J ON SHEET G6.1
EXPANSION JOINT w/SEALANT- SEE DETAIL E ON SHEET G6.1 (TYP.)
CONTROL JOINT - SEE DETAIL C & I ON SHEET G6.1 (TYP.)
HVAC UNIT PAD - SEE DETAIL H ON SHEET G6.1
TRANSFORMER PAD - SEE DETAIL H ON SHEET G6.1
LANDSCAPE AREA - SEE LANDSCAPE PLAN
DETENTION POND - SEE GRADING PLAN
DUMPSTER ENCLOSURE - SEE ARCHITECTURAL PLANS
LIGHT POLE - SEE ELECTRICAL PLANS
ASPHALT PATH - SEE DETAIL A ON SHEET G6.1
CONCRETE STOOP - SEE DETAIL F ON SHEET G6.1
CONCRETE BOLLARD - SEE DETAIL B ON SHEET G6.2
4" WIDE WHITE LINE (TYPICAL)
4" WIDE BLUE LINE (TYPICAL)
4" WIDE BLUE LINES @ 2'-0" O.C. DIAGONALLY - SEE DETAIL P ON SHEET
G6.1
PAINTED ADA SYMBOL - SEE DETAIL O ON SHEET G6.1 (TYP.)
ADA PARKING SIGN (TYPICAL AT EACH ADA PARKING SPACE) -
SEE DETAIL N ON SHEET G6.1
PRECAST PARKING BUMPER - SEE DETAIL L ON SHEET G6.1
TAPER CURB - SEE DETAIL K ON SHEET G6.1
ADA RAMP - SEE DETAIL Q ON SHEET G6.1
BICYCLE RACK - SEE DETAIL H ON SHEET L1.3
10' WIDE MULTIUSE PATH. SEE DETAIL R ON SHEET G6.1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY
ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR
WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR
EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES
SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND
WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE
OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY
ALL CONSTRUCTION.
THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES
EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES,
SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND
CAUTION !!
Know what's below.
before you dig.Call
R
Call 811 or 1-800-382-5544 Before You Begin Any Digging Project.
Call 48 hours or 2 working days before you dig.
It's Fast, It's Easy and It's the Law in the state of Indiana!
LEGEND
NEW BUILDING
NEW ASPHALT PAVEMENT
NEW CONCRETE SIDEWALK
PARKING SUMMARY - PROJECT AREA
STANDARD PARKING SPACES 330
ADA PARKING SPACES
EXISTING
0
PROPOSED TOTAL
PARKING SPACES
TOTAL
118
5 5
448
SURFACE AREA SUMMARY
IMPERVIOUS AREA ADDED
IMPERVIOUS AREAS 1.53 ACRE
TOTAL AREA
PERVIOUS AREAS
EXISTING
PERCENTAGE IMPERVIOUS AREA
DEVELOPED
(BUILDINGS, PAVEMENT, SIDEWALK)
(LAWN, LANDSCAPE, STONE, PLAYGROUND)
6.02 ACRE
11.74 ACRE 5.02 ACRE
13.27 ACRE
4.49 ACRE
11.5%54.5%
11.04 ACRE
NEW BUILDING
152,240 SFT.
MATCH LINE - SEE SHEET G2.2
BUILD LIMIT LINE - EDGE OF TREELINE AND SLOPE PLANNORTHN
WS ECOPYRIGHT 2019 BY FANNING/HOWEY ASSOCIATES, INC.
WWW.FHAI.COM
ARCHITECT
CONSULTANT
6/13/2019 3:21:38 PM\\data1\citrixprofiles$\amiller\My Documents\218052.00_ARCH_amiller.rvtPROJECT NUMBER: 2019199.00
INDOOR FACILITY
AT BADGER
FIELDS
CLAY TOWNSHIP
5459 E MAIN STREET
CARMEL, INDIANA
PROJECT ISSUE DATE: August 23, 2019
DRAWN BY: MTP
REV.
NO.DESCRIPTION DATE
11300453
SOI
STATE OF
ORPF
E
S NEER N LA E N GIANAINIDER DAHC I
IG S
No.
TERE
D
A
CNIK.N
DTAC COMMENTS 09/06/20191
SITE LAYOUT PLAN
G2.1
SITE LAYOUT PLAN
SCALE: 1"= 40'N
40 12004080