HomeMy WebLinkAboutGN010.0- ENERGY CERTIFICATEIECC 2009 Performance Compliance
Property
11789 WEST RD
ZIONSVILLE, IN 46077
Model: HERON
Community: WATERFRONT AT WE:
WWC42 (AS DESIGNED)
WATERFRONT AT WEST CLAY 42
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PAULSHOOPMAN
HOME BUILDING
GROUP
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
S1,579
S287
S196
$2,063
S1,153
SO
$3,216
Requirements
C4405.3
Performance -based compliance passes by 0.9%
R402.4.12
Air Leakage Testing
C4402.5
Area -weighted average fenestration SHGC
402.5
Area -weighted average fenestration U-Factor
40322
Duct Testing
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052
Duct Insulation
C-M,
Energy Solutions
As Designed
$1,653
$195
$197
$2,044
$1,153
$0
$3,197
Air sealing is S.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa.
Design exceeds requirements for IECC 2009 Performance compliance by 0.9%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party.
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date: 7115119 at 7:09 AM
Ekotrope RATER -Version 3.1.0.2213
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
11789 WEST RD
ZIONSVI LLE, IN 46077
Builder: PAUL SHOOPMAN HOME BUILDING GROUP
�JFM[al
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls R-10
Framed Floor N/A
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 5 ACH50
Window U-Value: 0.3, SHGC: 0.25
Building Features
Duct Supply R-10.0, Return R-10.0
Duct Leakage to Outside 168 CFM @ 25Pa (3.951100 s.f.)
Total Duct Leakage 336.0 CFM @ 25Pa
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Natural Gas • 0.64 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Dlevin Sielschott
Organization: TSI Energy Solutions
Signature:
Date: 7/15119 at 7:09 AM
Ekotrope RATER - Version 3.1.0.2213
20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information sh own on this report.
Energy Code Inspection Checklist
Property
Organization
11789 WEST RD
TSI Energy Solutions
ZIONSVILLE, IN 46077
Devin Sielschott
Model: HERON
Community: WATERFRONT AT WE:
Builder
PAUL SHOOPMAN
WWC42 (AS DESIGNED)
HOME BUILDING
WATERFRONT AT WEST CLAY 42
GROUP
General Building Information
Conditioned Area (sq ft) 4,254
Conditioned Volume (cubic ft) 46,095
Insulated Shell Area (sq ft) 10,636
inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
[ Name: BSMT(1,069 s.f., 57 ft. exterior perimeter)
R-0 perimeter insulation, R-0 under slab insulation.
[ Name: CRAWL(2,116 s.f., 211 ft. exterior perimeter)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
E[ Name: CONDIAMB FIN (Exterior Perimeter [ft]: 35, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 9.696
Fully insulated (top to bottom)
E[ Name: CONDIGAR (Exterior Perimeter [ft]: 22, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R-0 continuous insulation, R-0 cavity insulation
Insulation Grade: I
Fully insulated (top to bottom)
El Name: CRAWLIAMB (Exterior Perimeter [ft]: 172, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 2)
R: 10.00
Fully insulated (top to bottom)
El Name: CRAWL/GARAGE (Exterior Perimeter [ft]: 39, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 2) 1
R: 10.00
Fully insulated (top to bottom)
Energy Code Inspection Checklist
Property
11789 WEST RD
ZIONSVILLE, IN 46077
Model: HERON
Community: WATERFRONT AT WE:
WWC42 (AS DESIGNED)
WATERFRONT AT WEST CLAY 42
Above Grade Wall
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PAULSHOOPMAN
HOME BUILDING
GROUP
El Name: CONDIAMB (2,079 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CONDIGAR (468 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CONDIATTIC (278 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
El Name: CONDIAMB (217 s.f.)
R: 13.575
El Name: CONDIGAR (52 s.f.)
R: 13.575
Roof
Name: MAIN (3,085 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Name: VAULT (126 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (24 s.f.)
U: 0.476
Name: GARAGE (24 s.f.)
U: 0.182
Inspection Status
Results are projected
C-M,
Energy Solutions
2
Energy Code Inspection Checklist
Property
11789 WEST RD
ZIONSVILLE, IN 46077
Model: HERON
Community: WATERFRONT AT WE:
WWC42 (AS DESIGNED)
WATERFRONT AT WEST CLAY 42
Name: GARAGE (24 s.f.)
U: 0.182
Glazing
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PAULSHOOPMAN
HOME BUILDING
GROUP
Inspection Status
Results are projected
El Name: FRONT (74 s.f.), U: 0.300, SHGC: 0.25, Orientation: SOUTH
11 Name: BACK (126 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH
11 Name: SLIDER (96 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH
11 Name: CURTAIN WALL (160 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH
E] Name: BACK BSMT (30 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH
E] Name: LEFT (62 s.f.), U: 0.300, SHGC: 0.25, Orientation: WEST
E] Name: RIGHT (54 s.f.), U: 0.300, SHGC: 0.25, Orientation: EAST
Skylight
None Present
Mechanical Ventilation
None Present
Mechanical Equipment
El HEATING • Natural Gas • 100% Heating Load @ 92.1 AFUE
El CODLING -Electric- 100% Cooling Load @ 13 SEER
Water Heating • Natural Gas • 100% Hot Water Load @ 0.64 Energy Factor
Air Leakage Control
C-M,
Energy Solutions
3
Energy Code Inspection Checklist
Property
Organization Inspection Status
11789 WEST RD
TSI Energy Solutions Results are projected
ZIONSVILLE, IN 46077
Devin Sielschott
Model: HERON
Community: WATERFRONT AT WE:
Builder
PAUL SHOOPMAN
WWC42 (AS DESIGNED)
HOME BUILDING
WATERFRONT AT WEST CLAY 42
GROUP
ElTest Status: Blower -door tested
House is air -sealed as to achieve 3,841 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC. Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Leakage to Outside specified as: 168 CFM @ 25Pa (3.95 / 100 s.f.)
Total Duct Leakage specified as 336.0 CFM @ 25Pa (Post -Construction)
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
Building Summary
Property
C-MEnergy Solutions
Organization Inspection Status
11789 WEST RD
TSI Energy Solutions Results are projected
ZIONSVILLE, IN 46077
Devin Sielschott
Model: HERON
Community: WATERFRONT AT WEST CLAY 42
Builder
PA U L S HOO PMAN HOME
WWC42 [AS DESIGNED]
BUILDING GROUP
WATERFRONT AT WEST CLAY 42
Genera?Building Information
Number Of Bedrooms
4
Number Of Floors
1
Conditioned Floor Area [sq_ ft.]
4;254
Unconditioned, attached garage?
Yes
Conditioned Volume [cu. ft.]
46,095
Total Units in Building
1
Residence Type
Single family detached
Floor Number
Model
HERON
Community
WATERFRONT AT WEST CLAY 42
Climate Zone
5A
Foundation Wall
Name Library Type
Height Above Grade Depth Below Grade Perimeter
Location Enclosing
CONDIAMB FIN R-11 Finished, G1
1
8
35
Exposed Exterior Conditioned Space
CONDIGAR Uninsulated
1
8
22
Exposed Exterior Conditioned Space
CRAWLIAMB R-10 Draped, Full
1
2
172
Exposed Exterior Conditioned Crawlspace
CRAWLIGARAGE R-10 Draped, Full
1
2
39
Exposed Exterior Conditioned Crawlspace
Foundation Wall Library List
Name Feet From Wall Top To
Feet From Wall Top 7b
Is Fully Insulated Continuous R-value
Cavity R-value Effective Insulation R-
Continuouslnsulation
Continuous Insulation
value
Top
Bottom
R-10 Draped, Full NIA
NIA
Yes
WA
NIA 10.00
R-11 Finished, G1 NIA
NIA
Yes
WA
NIA 9.696
Uninsulated NIA
NIA
Yes
0.00
NIA NIA
lSlab���"
qqw ql�
Name Library Type
Perimeter Floor Grade
Carpet R Exposed
Surface Area Location Enclosing
Masonry Area
BSMT Uninsulated
57 Below Grade
123 0
1:069.0 f[' Exposed Exterior Conditioned
Space
CRAWL Uninsulated
211 Below Grade
123 0
2:116.0 tC Exposed Exterior Conditioned
Crawlspace
1
Building Summary
C-M
Energy Solutions
Property Organization Inspection Status
11789 WEST RD TSI Energy Solutions Results are projected
ZIONSVILLE, IN 46077 Devin Sielschoft
Model: HERON
Community: WATERFRONT AT WEST CLAY 42 Builder
PAUL S HOOPMAN HOME
WWC42 [AS DESIGNED] BUILDING GROUP
WATERFRONT AT WEST CLAY 42
Slab Library List MEMMUM
Name Wall Construction Slab Completely Underslab Perimeter Perimeter Thermal Break Effective R-value
Type Insulated. Insulation Width Iffy Insulation Depth [ft] Insulation R Value
Uninsulated Woad Frame / Other No ❑ ❑ ❑ No D.00
Framed Floor
None Present
Framed Floor Library List
None Present
Rim Joist
Name
CONDIAMB
C O N DIGAR
Library Type
Surface Area
Location
G1 R-13, R-3.0 217.0 f` Exposed Exterior
G1 R-13, R-3.0
Rim Joist Library List
Name Effective Insulation R-value
G1 R-13, R-3.0 13.575
al=
Name
CONDIAMB
CONDIATTIC
52.0 f` Unconditioned, attached garage
n
G1 R-13 BATT, R-3-0 Medium 2.079.0 ft' Exposed Exterior
G1 R-13 BATT, R-3.0 Medium 27B.0 ft' Attic
Building Summary
Property
11789 WEST RD
ZIONSVILLE, IN 46077
Model: HERON
Community: WATERFRONT AT WEST CLAY 42
WWC42 [AS DESIGNED]
WATERFRONT AT WEST CLAY 42
Name
Organization
TSI Energy Solutions
Devin Sielschott
Builder
PA U L S HOO PMAN HOME
BUILDING GROUP
Library Type
Inspection Status
Results are projected
Surface Color
Surface Area
Energy Solutions
C-M
Location
CONDIGAR G1 R-13 Gar Walls
Medium
46B.0 fts
Unconditioned, attached garage
Wall Library List
Name
Effective R-value
G1 R-13 BATT, R-3.0
15.12
G1 R-13 Gar Walls
11.141
Glazing
Name Library Type Wall Assignment Foundation Wall Overhang Depth
Overhang Ft To
Overhang Ft To
Orientation
Surface Area
Assignment
Top
Bottom
BACK U-.30, SHGG25
CONDIAMB
0
0
0
North
126.0 fts
BACK BSMT U-.30, SHGG25
CONDIAMB FIN
0
0
0
North
30.0 fF
CURTAIN WALL U-.30, SHGG.25
CONDIAMB
0
0
0
North
160.0 R2
FRONT U-.30, SHGG25
CONDIAMB
0
0
❑
South
74.0 fF
LEFT U-.30, SHGG25
CONDIAMB
0
0
❑
West
62.0 ft
RIGHT U-.30, SHGG25
CONDIAMB
0
0
❑
East
54.0 ft
SLIDER U-.30, SHGG25
CONDIAMB
0
0
❑
North
96.0 f'
Glazing Library List
Name
Shg c
U factor
U-.30, SHGC-25
025
0.300
Skylight
3
Building Summary
Property
Organization
11789 WEST RD
TSI Energy Solutions
ZIONSVILLE, IN 46077
Devin Sielschott
Model: HERON
Community: WATERFRONT AT WEST CLAY 42
Builder
PAUL S HOOPMAN HOME
WWC42 [AS DESIGNED]
BUILDING GROUP
WATERFRONT AT WEST CLAY 42
Skylight Library
Inspection Status
Results are projected
C-M,
Energy Solutions
Opaque Door
Name Library Type Wall Assignment
Foundation Wall
Assign ment
Emittance
Solar Surface Color Surface Area
Ab sorpta n ce
Location
FRONT Woad Door CONDIAMB
0.9
0.75
Medium 24.0 fts
Exposed Exterior
GARAGE Fiberglass/Steel CONDIGAR
0.9
0.75
Medium 24.0 It'
Exposed Exterior
Door
GARAGE Fiberglass/Steel CONDIGAR
0.9
0.75
Medium 24.0 fC
Exposed Exterior
Door
WF
Opaque Door Library List
Name Effective U-factor
IFiberglass/Steel Door
0.182
Wood Door
0.476
Roof Insulation
Name Library Type Attic Exterior Area Clay or Concrete Roof
Surface Color
Surface Area
Location
1.11
Tiles
MAIN R-38 Blown, GR1
3,085
No
Medium
3,085.0 f[s
Attic
VAULT R-38 Vaulted, GR1
126
No
Medium
126.0 fts
Vaulted Roof
Roof Insulation Library List
Name Has Radiant Barrier
Effective R-value
R-38 Blown, GR1
No
38268
R-38 Vaulted, GR1
No
32263
4
Building Summary
Property
11789 WEST RD
ZIONSVILLE, IN 46077
Model: HERON
Community: WATERFRONT AT WEST CLAY 42
WWC42 [AS DESIGNED]
WATERFRONT AT WEST CLAY 42
Whole House Infiltration
Infiltration
5 ACH at 50 Pa
Mechanical Ventilation
Lighting ,
°I Interior Fitiorescent
Lighting
Gnsite Generation
Organization Inspection Status
TSI Energy Solutions Results are projected
Devin Sielschott
Builder
PA U L S HOO PMAN HOME
BUILDING GROUP
Blower -door tested 4
None Present
Gnsite Generation Library List
None Present
Solar Generation
Solar Generation Library List
a riuorescens
Lighting
0
C-M,
Energy Solutions
Lighting
0
Building Summary
Property Organization
11789 WEST RD TSI Energy Solutions
ZIONSVILLE, IN 46077 Devin Sielschott
Model: HERON
Community: WATERFRONT AT WEST CLAY 42 Builder
PAUL S HOOPMAN HOME
WWC42 [AS DESIGNED] BUILDING GROUP
WATERFRONT AT WEST CLAY 42
Conditioning Equipment
Name Library Type Pleating Percent L
COOLING CA13NA048
HEATING 9125A48100S21 100%
Water Heatina RG1 PV50S'N
Equipment Type: 912SA4810OS21
0%
C-M
Energy Solutions
Inspection Status
Results are projected
100 %
0%
0% 0%
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
92.1 AFUE
Heating Capacity [kBtulh]
93
Use default EAE
No
EAE [kWh]
756
Equipment Type: CA13NA048am
Fuel Type
Electric
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Cooling Efficiency
13 SEER
Cooling Capacity [kBtulh]
45.5
7
Equipment Type: RG1 PVWS*N
Fuel Type
Natural Gas
Distribution Type
Hydronic Delivery
Hot Water Efficiency
0.64 Energy Factor
Tank Capacity (gal.)
50
Hot Water Capacity [kBtulh]
40
Recovery Efficiency
0.80
r Percent Load Location
0% Conditioned Space
❑ % Conditioned Space
100 % Conditioned Space
Al
Building Summary
Property
Energy Solutions
Organization Inspection Status C-M
11789 WEST RD
TSI Energy Solutions Results are projected
ZIONSVILLE, IN 46077
Devin Sielschott
Model: HERON
Community: WATERFRONT AT WEST CLAY 42
Builder
PA U L S HOO PMAN HOME
WWC42 [AS DESIGNED]
BUILDING GROUP
WATERFRONT AT WEST CLAY 42
Distribution System
Distribution Type
Forced Air
Heating Equipment
HEATING
Cooling Equipment
COOLING
Sq. Feet Served
4254
# Return Grilles
4
Supply Duct R Value
10
Return Duct R Value
10
Supply Duct Area r]
1148.58
Return Duct Area [ft2]
850.8
Leakage to Outdoors
168 CFM @ 25Pa (3.951 100 s.f.)
Total Leakage
336
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct t
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
50
Percent Return Area
50
Duct 2
Duct Location
Conditioned Space
Percent Supply Area
50
Percent Return Area
50
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
rCeiling Fan
Has Ceiling Fan No
Cfm Per Watt 101
7
Building Summary
Property
11789 WEST RD
ZIONSVILLE, IN 46077
Model: HERON
Community: WATERFRONT AT WEST CLAY 42
WWC42 [AS DESIGNED]
WATERFRONT AT WEST CLAY 42
Water Distribution
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I met
Appliances and Controls
Programmable thermostat?
Dishwasher Size
Dishwasher Efficiency
Range/Oven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Organization Inspection Status
TSI Energy Solutions Results are projected
Devin Sielschott
Builder
PAUL S HOOPMAN HOME
BUILDING GROUP
Standard
No
45
No
No
10
No
Electric
Timer Controls
ff"W
704 kWh/Year
$0.081kWh
$23.00
$0.581Therm
2.874
❑.33053
Yes
Standard
270 kWh
Electric
No
No
709 kWh/Year
"M �
C-M,
Energy Solutions
,�