Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Construction Plans 06-26-19
COVERSHEETCS 0.1ARCHITECTURALA2.0A2.1A3.0A1.2Exterior ElevationsExterior ElevationsBuilding & Stair SectionRoof Plan & Wall SectionSHEET INDEXGENERALCS1.0COVER SHEETLOCATION MAPA1.1Upper Level PlanA1.0Lower Level PlanBrowning's GarageConstruction DrawingsCarmel, IN 4603212650 Clay Center RdGENERAL NOTES1.DO NOT SCALE THE DRAWINGS. ALL DIMENSIONS ARE TAKEN TO FACE OF STUD,FACE OF CONCRETE, FACE OF MASONRY, UNLESS NOTED AS CLEAR (CLR.). CLEARDIMENSIONS INDICATE FINISH SURFACE TO FINISH SURFACE SPANS BETWEEN WALLS.2.PRELIMINARY SIZES OF STRUCTURAL ITEMS ARE REPRESENTED ONLY FOR THE SOLEPURPOSE OF PROVIDING A GENERAL IDEA FOR THE SCOPE OF WORK. FINAL SIZES OFSTRUCTURAL ITEMS TO BE PROVIDED BY OTHERS.3.THE DESIGNER ASSUMES NO RESPONSIBILITY FOR ANY DAMAGES, INCLUDINGSTRUCTURAL FAILURES DUE TO DEFICIENCIES, OMISSIONS, OR ERRORS IN THEDESIGN CONSTRUCTION DOCUMENTS.4.THE COORDINATION OF ALL CIVIL, LANDSCAPE, MECHANICAL, ELECTRICAL ANDPLUMBING TO BE PROVIDED BY OTHERS.5.THE CONTRACTOR SHALL NOTIFY THE OWNER OR ARCHITECT OF ANY CONDITIONSTHAT ARE IN CONFLICT WITH THE PROPOSED WORK OR ARE IN VARIANCE WITH THECONSTRUCTION DOCUMENTS, INCLUDING, CONFLICTS, DISCREPANCIES, ANDOMISSIONS PRIOR TO COMMENCEMENT OF WORK.6.CONTRACTOR TO COORDINATE WITH GOVERNING AUTHORITIES, CONSTRUCTIONTRAFFIC ACCESS TO THE SITE AND DESIGNATE CONSTRUCTION ACCESSTHROUGHOUT THE BUILDING.7.THESE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OFARCHITECTURAL DESIGN CONCEPT, THE DIMENSIONS OF THE BUILDING, AND THEMAJOR ARCHITECTURAL ELEMENTS. AS GRAPHIC DOCUMENTS. THE DRAWINGS DONOT INDICATE OR DESCRIBE THE WORK REQUIRED FOR THE FULL PERFORMANCEAND COMPLETION OF THE CONTRACT DOCUMENTS. ON THE BASIS OF THE GENERALSCOPE INDICATED OR DESCRIBED. THE CONTRACTORS SHALL STUDY THE DRAWINGSAND THEIR GENERAL INFERENCE TO FURNISH THE ITEMS REQUIRED FOR THEPROPER EXECUTION AND COMPLETION OF THE WORK.OPENING SCHEDULE1.ALL EXTERIOR DOORS TO BE INSULATED W/ INSULATEDGLAZING.2.PROVIDE SAFETY GLAZING AS REQ. BY CODE.3.ALL EGRESS WINDOWS TO MEET INTERNATIONALRESIDENTIAL CODE EGRESS REQUIREMENTS.GENERAL OPENING NOTES:AREASLOWER FLOOR NET AREASROOM NAMEAREAGARAGE2531STORAGE /MECH108UPPER FLOOR NET AREASROOM NAMEAREAFINISHED AREA2498TYPESIZECOUNTSWING - PR 2-6 X 6-8 1SWING - PR 3-0 X 6-8 1OVERHEAD - 8-0 X 10-0 3SWING - 3-0 X 6-8 2.OWER .EVE. DOORSGENERAL NOTESBrowning's Garage12650 Clay Center Rd.,Carmel, IN 46032Scale:Issue Date:Drawn:Project:1905JUNE 26, 2019AS NOTEDJEF1.SEE COVER SHEET CS1.0 FORGENERAL NOTES.Construction DrawingsOVERHEAD -10-0 X 7-0 17PPER .EVE. DOORS7PPER .EVE. WINDOWSCASEMENT - 2834 6CASEMENT- 2830 5A3.1Wall SectionFIXED - 3954 1 10'-0"15'-0"7'-4"9'-8"49'-8"UP2 CAR GARAGE12' GYP. CLG.EPOXY FLR.WASH BAY12' CLG.EPOXY FLR.OFFICE12' GYP CLG.EPOXYSLOPE1/8:12SLOPE1/8:12SLOPE 1/16:1210/0 x 8/010/0 x 8/010/0 x 8/03/0HWSFP R 3 / 0 50'-10" 4'-10" SLOPE 1/16:12 FURNWDUTILITY12' CLG.CONC.P R 2 / 6 45'-9 1/2"50'-7 1/2"4" MIN. REINF. CONC. SLAB W/ 6X6WWF, OVER VAPOR RETARDER ON4" COMPACTED STONE, OVERUNDISTURBED SOIL BASEFIRST FLOOR FRAMING FIRST FLOORFRAMING FIRST FLOOR FRAMING 8"30'-5" 3 1/2" 18'-5 1/2"1'-0"8"7'-0"EQEQEQEQ 2'-6 1/2" 3 1/2" 3'-8 1/2"3'-4"20'-10"8'-0" 3 1/2" 6'-0"4'-2"12'-10"14 TR @ 11" EA.10'-10 3/4"3'-4 3/4" 3 1/2"1'-0"5'-10"3 1/2"ENGINEERED REINF. CONCBUTTRESS AS REQ. FOR BACKFILLSUPPORT4" MIN. REINF. CONC. SLAB W/ 6X6WWF, OVER VAPOR RETARDER ON4" COMPACTED STONE, OVERUNDISTURBED SOIL BASE4'-0" CLR 8"6'-3"3 1/2"4'-0"3 1/2"5'-10"3'-3"3'-3 1/2"UTILITY SINKUTILITY SINK8" CMUSTONE FACADETYP. @ FF2X W/ 1-1/2" RIGIDINSULATION BRD. BETWEEN3/0COUNTER W/ UPPER& BASE CABINETSCOUNTER W/ UPPER& BASE CABINETSSTEP LEDGE W/ GRADE. MIN.2'-0" HORZ. IN LENGTH.PROVIDE BEAM POCKET ORPOST AT BEAM LOCATIONSMOISTURE RESISTANTFINISH, WALLS & CLNG.TRENCHDRAINTRENCHDRAIN51'-4" OA 51'-5" OASTEEL BEAMABOVESTEEL BEAMABOVEHOSE BIBBPLAN1Lower LevelA1.01/4" = 1'-0"LOWER LEVELPLANA1.0GENERAL NOTESBrowning's Garage12650 Clay Center Rd.,Carmel, IN 46032Scale:Issue Date:Drawn:Project:1905JUNE 26, 2019AS NOTEDJEF1.SEE COVER SHEET CS1.0 FORGENERAL NOTES.Construction Drawings2A3.01A3.01A3.1 10'-9"15'-0"15'-0"10'-9"51'-6"DN13'-7 3/4"5'-8"6'-8"5'-8"13'-1 3/4"1'-6"13'-7 3/4"12'-4"12'-4"13'-1 3/4"10'-9"15'-0"15'-0"10'-9"2834 C2834 C2834 C2830 C 2830 C 2830 C 2834 C2834 C2830 C2830 C 51'-5 1/2"2834 C6'-8"STORAGESLOPED GYP.CLG.WOOD FLR.SLOPE CLNG 3:12 SLOPE CLNG 3:12 10/0 x 7/0 5'-6" 6 TR @ 11" EA.4'-0"CLR5 1/2" TYP 4'-0" 5 1/2" 5'-0 1/2"5 1/2"7'-11 1/2"5 1/2"9 1/2"9 1/2"CANTILEVERED DORMER3954 F (ABOVE)HOSE BIBBLINE OFROOF ABOVEPLAN1Upper LevelA1.11/4" = 1'-0"UPPER LEVELPLANA1.1GENERAL NOTESBrowning's Garage12650 Clay Center Rd.,Carmel, IN 46032Scale:Issue Date:Drawn:Project:1905JUNE 26, 2019AS NOTEDJEF1.SEE COVER SHEET CS1.0 FORGENERAL NOTES.Construction Drawings2A3.01A3.01A3.1 SLOPE 6:12 SLOPE 6:12RIDGE WALL BELOW2X WOOD SCISSORTRUSS, TYP.2X LOOKOUTSASPHALT SHINGLES OVER 30#FELT AND ICE & WATER SHIELDON 5/8" ROOF SHEATHING W/CLIPS.CANTILEVERED DORMERCONT. VENTED RIDGE2'-0"2'-0"6'-0"3'-4"4'-0"2'-0"2'-0"6'-6"ELEV = 113'-4 3/4"T.O. UPPER FLR.ELEV = 100'-0"T.O. LOWER FLR.5'-11 1/2"1'-6"9'-6"7'-1"PLAN1Roof LevelA1.21/8" = 1'-0"ROOF LEVEL PLAN& WALL SECTIONA1.2GENERAL NOTESBrowning's Garage12650 Clay Center Rd.,Carmel, IN 46032Scale:Issue Date:Drawn:Project:1905JUNE 26, 2019AS NOTEDJEF1.SEE COVER SHEET CS1.0 FORGENERAL NOTES.Construction DrawingsSECTION2LoftA1.21/2" = 1'-0" ELEV = 113'-4 3/4"T.O. UPPER FLR.ELEV = 100'-0"T.O. LOWER FLR.9'-6" PLATE HEIGHTDIMENSIONAL SHINGLE5/4 X 10 FASCIA BOARDPREFINISHED GUTTER &DOWNSPOUTSBOARD & BATTEN SIDINGSTONE MASONRYBRICK ARCH1X4 TRIMOVERHEAD SECTIONALDOOR5/4 X 6 W/ BEVELED TOPEDGE1 X 4 WINDOW TRIMLINE OF GABLE DORMER9'-6" PLATE HEIGHTELEV = 113'-4 3/4"T.O. UPPER FLR.ELEV = 100'-0"T.O. LOWER FLR.1265/4 X 10 FASCIA BOARDPREFINISHED GUTTER &DOWNSPOUTSBOARD & BATTEN SIDINGSTONE MASONRY1X4 WINDOW TRIMOVERHEAD SECTIONALDOOR5/4 X 6 W/ BEVELED TOPEDGEGABLE END DORMER5/4 X 10 DOORTRIM1X8 TRIM BOARD1X6 TRIM BOARDDECORATIVE WOODBRACKETDECORATIVE SHUTTERS9'-6"13'-4 3/4"ELEVATION1NORTHA2.03/16" = 1'-0"EXTERIORELEVATIONSA2.0GENERAL NOTESBrowning's Garage12650 Clay Center Rd.,Carmel, IN 46032Scale:Issue Date:Drawn:Project:1905JUNE 26, 2019AS NOTEDJEF1.SEE COVER SHEET CS1.0 FORGENERAL NOTES.Construction DrawingsELEVATION2WESTA2.03/16" = 1'-0"9'-6"13'-4 3/4" 6'-10" 1'-2" + / - 6'-10"1A3.01A3.0 ELEV = 113'-4 3/4"T.O. UPPER FLR.ELEV = 100'-0"T.O. LOWER FLR.9'-6" PLATE HEIGHTDIMENSIONAL SHINGLE5/4 X 10 FASCIA BOARDPREFINISHED GUTTER &DOWNSPOUTSBOARD & BATTEN SIDINGSTONE MASONRY5/4 X 6 W/ BEVELED TOPEDGELINE OF GABLE DORMER9'-6" PLATE HEIGHTELEV = 113'-4 3/4"T.O. UPPER FLR.ELEV = 100'-0"T.O. LOWER FLR.1265/4 X 10 FASCIA BOARDPREFINISHED GUTTER &DOWNSPOUTSBOARD & BATTEN SIDINGSTONE MASONRY1X4 WINDOW TRIM5/4 X 6 W/ BEVELED TOPEDGEELEVATION1SOUTHA2.13/16" = 1'-0"EXTERIORELEVATIONSA2.1GENERAL NOTESBrowning's Garage12650 Clay Center Rd.,Carmel, IN 46032Scale:Issue Date:Drawn:Project:1905JUNE 26, 2019AS NOTEDJEF1.SEE COVER SHEET CS1.0 FORGENERAL NOTES.Construction DrawingsELEVATION2EASTA2.13/16" = 1'-0"9'-6"13'-4 3/4" 13'-4 3/4"9'-6" 6'-10" 6'-10" ELEV = 113'-4 3/4"T.O. UPPER FLR.ELEV = 100'-0"T.O. LOWER FLR.12'-0" 1'-4" 9'-6"1261239'-1 5/8" (15) EQ. R 3'-0" 4'-3 1/8" (7) EQ. R 13'-4 3/4" 3'-0"11" TYPADHERED 3/4" T&GPLYWOOD ON WOOD 'I'JOIST2X4 WOOD FRAMEDGUARDRAIL W/ 1X6 WOODCAPWOOD 'I' JOIST HEADER1 1/2" DIA. HANDRAIL2X12 STRINGERSWALL BEYOND262626262626262626242424242428" CMUGYPSUM BOARDWOOD FURRING8" CMU46" CMUOVERHEAD DOORASSEMBLY1X8 TRIMOVERHEAD DOORASSEMBLY1X TRIM1X TRIMR-19 BATT INSULATIONFLUID APPLIED MOISTURE &AIR BARRIERMOISTURE & AIR BARRIERWRAP12" EXTERIOR SHEATHINGSTONE FACADECONT. SEALANT &BACKER ROD4"GYPSUM BOARDSection1Building SectionA3.03/16" = 1'-0"BUILDING & STAIRSECTIONA3.0GENERAL NOTESBrowning's Garage12650 Clay Center Rd.,Carmel, IN 46032Scale:Issue Date:Drawn:Project:1905JUNE 26, 2019AS NOTEDJEF1.SEE COVER SHEET CS1.0 FORGENERAL NOTES.Construction DrawingsSection2StairA3.01/4" = 1'-0"JAMB DETAIL3OVERHEAD DOORA3.01 1/2" = 1'-0" 4" REINF. CONC. SLAB W/ CONT. 6 MIL.VAPOR BARRIER OVER COMPACTEDAGGREGATE BASE2X4 TREATED WOOD SOLE PLATETREATED 2X8 SILL PLATE W/ THERMALSILL SEALERENGINEERED WOOD FLR. JOIST SYSTEM12" GYP.BRD. CEILING OVER FLOOR JOIST(OPTIONAL 1X4 WOOD SLATS)1/2" EXPANSION MATERIAL4" PERIMETER DRAIN, INTERIOR &EXTERIOR. TIE TO SUMPREINF. CONC. FTG.FILTER FABRIC4" PERIMETER DRAIN 112" RIGID BRD. INSUL. BETWEENFURRING2x6 WOOD FRAMING @ 16" O.C.R-19 BATT INSUL.ELEV = 113'-4 3/4"T.O. FIRST FLR.ELEV = 100'-0"T.O. BASEMENT FLR.12" GYP. BRD.BOARD & BATTEN SIDING1/2" EXTERIOR SHEATHING12" GYPSUM BOARDMIN. 3'-0" BELOW GRADE 2" RIGID INSUL. BRD. W/DRAINAGE GROOVESCONT. DAMP PROOFING4"REINF. CONCRETE WALL8"STONE BASE54 X 6 TRIM BRD. W/SLOPED TOP EDGE2X4 WOOD TOP PLATEADHERED 3/4" T&G PLYWOODCONT. VAPOR BARRIERAIR BARRIER WRAPWEEPSFLEXIBLE FLASHINGR-38 BATT INSUL. 112" TREATED WOOD FURRING2'-0"5/8" OSB EXT. ROOF SHEATHING W/ CLIPSASPHALT SHINGLES OVER 30# FELTICE & WATER SHIELDMETAL DRIP EDGE1x10 FASCIA BRD.CONT. SOFFIT VENT1x6 FRIEZE BOARD2X WOOD SUB FASCIARAFTER BAFFLER-49 MIN. BATT OREQUIVALENT BLOWN-IN INSUL.SCISSOR TRUSS12" GYPSUM BOARD1x3 TRIM BRD.1x3 TRIM BRD.PREFINISHED GUTTER &DOWNSPOUT ASSEMBLYWALL SECTIONA3.1SECTION1WalA3.13/4" = 1'-0"GENERAL NOTESBrowning's Garage12650 Clay Center Rd.,Carmel, IN 46032Scale:Issue Date:Drawn:Project:1905JUNE 26, 2019AS NOTEDJEF1.SEE COVER SHEET CS1.0 FORGENERAL NOTES.Construction Drawings