HomeMy WebLinkAboutA02.01. INTERIOR DIMENSIONS ARE FROM FINISHED FACE
10. ALL SURFACE MOUNTED ELECTRICAL WALL
OF EXISTING PARTITION TO FACE OF NEW
BOXES AND CONDUIT SHALL BE RECESSED IN
2. PROVIDE BRACING AT ALL METAL STUD
WALL.
PARTITIONS THAT DO NOT EXTEND TO DECK.
11. REPLACE ALL RECEPTACLE COVERS WITH
3. ALL DOOR FRAMES IN METAL STUD WALLS SHALL
STAINLESS STEEL COVERS. ALL RECEPTACLES TO
BE SET 4" FROM PERPENDICULAR WALLS
BE GRAY
ADJACENT TO DOOR HINGE SIDE, U.N.O.
12. THE CENTER -LINES OF WALL MOUNTED
4. ALL DOOR FRAMES IN CMU WALLS SHALL BE SET
ELECTRICAL OUTLETS, SWITCHES, DEVICES, J-
8" FROM PERPENDICULAR WALLS ADJACENT TO
BOXES, HORWSTROBE DEVICES, MECHANICAL
DOOR HINGE SIDE, U.N.O.
SENSORS, RESETSWITCHES, ETC. SHALLALIGN
5. ALL BLINDS SHALL BE REMOVED AND REPLACED.
VERTICALLY, U.N.O. THE CENTER -LINES OF
REFER TO FINISH PLAN FOR LOCATIONS.
OUTLETS, DEVICES, ETC, OF VARYING SIZE THAT
6. CORNER GUARDS TO BE LOCATED ON ALL
OCCUR AT THE SAME ELEVATION SHALL ALIGN
OUTSIDE CORNERS, TYPICAL.
HORIZONTALLY.
7. ALL OUTSIDE EXPOSED CORNERS OF COUNTERS
13. ALL ABANDONED BOXES SHALL BE DELETED
AND SHELVING $HALL HAVE A6" RADIUS U.N.O.
AND/OR PATCHED; NO BLANKCOVER PLATES WILL
B. PROVIDE WOOD BLOCKING IN STUD WALLS FOR
BE ACCEPTED.
ALL WALL MOUNTED ACCESSORIES, FIXTURES,
14. LOCATE GROMMETS PER TYPICAL WORKSTATION
FURNITURE AND SYSTEMS; SEE FIXTURE PLAN.
ELEVATION UNLESS OTHERWISE NOTED. CONFIRM
9. G.C. TO PROVIDE 310SOUND ATTENUATION
FINAL LOCATIONS WITH OWNER PRIOR TO
BATTS IN WALL$ AND CEILINGS AT LGM, PM,
INSTALLATION.
SERVICE MANAGER, CHAT CONFERENCE AND
15. GC TO PROVIDE FRT PLYWOOD BETWEEN METAL
SALES MANAGER.
STUDS TO MATCH OVERALL HEIGHT AND WIDTH OF
WALL MOUNTED MONITORS AND TVs, U.N.O; GC TO
COORDINATE FINAL SIZE AND LOCATION WITH
OWNER. SEE DETAIL 7/A7.4
0 EXISTING TO REMAIN PARTITION
NEW PARTITION
® NEW LOW PARTITION
2 SALES
MGR
2
4
7 A7.1 6
PARTITIONALIGN 5
WITH FACE OF
SOFFIT ABOVE
-
CG CG
'-8" 5'-0" 13'-6"
G4E G4E 2
FUTURE
OFFICE
731 f-6"
4�GN 37'-7"
1 RELOCATED FIRE
1 - STEEL
FENER, 0 EXTINGUISHER m
A7.4 AIA STIFFENER, SEE CABINET, SEE G1.2 p
SIM 21A7.4 AND STRUCT
DWGS, TYR
Gfi
■
�t
■
DOT INDICATES 00
EXISTING FLOOR BOX
LOCATION
ALIGN
2'-83/4"
A7.0 3
7 SHOWROOM
5 AI-0 m
� i e
SALES OWNER PROVIDED LIGHTED
L= ENTRANCE DISPLAY CENTERED ON
6 ENTRANCE; SEE INTERIOR
L A7 q ELEVATION AND ELECT DWGS
2 LINE OF EXISTING
SOFFIT TO REMAIN
- - - - - - - \
WALL SCHEDULE
ISLA 1/2" GWB ON ONE SIDE OF I-5181", 20 GA MTL FURRING@ 16" OC TO
SOFFITABOVE
G43 1/2" GWB ON ONE SIDE OF 3-51811,20 GA MTL STUDS @16"OC TO
SOFFIT/ 6" ABOVE CEILING
G4C ALLINTERIORWALLS (UND): 1/2" GWB ON BOTH SIDES OF3-518", 20 GA
MTL STUDS @ 16" OC T06" ABOVE CEILING, EXTEND AND SEAL TO
DECK WHERE CEILING IS EXPOSED
G4E 1/2" GWB BD ON BOTH SIDES OF 35181120 GA MTL STUDS @161 O.C. TO
4'-0"AFF U.N.O., SEE ELEVATIONS AND DETAILS
56A 1/2" GWB ON ONE SIDE OF 6", 18 GA MIEL STUDS @16"OC GWB TO
TERMINATE 6" BELOW DECK; PROVIDE HORIZONTAL BRIDGING
VERTICALLY SPACED AT 48" O.C.
G6C 1/2" GWB ON BOTH SIDES OF T, 20 GA MR STUDS @16"OC TO T ABV
CEILING, EXTEND AND SEAL TO DECK WHERE CEILING IS EXPOSED
G6E 1/2" GWB BD ON BOTH SIDES OF T20 GA MTL STUDS @16"O.C. TO 42"
AFF U.N.O., SEE ELEVATIONS AND DETAILS
G6K 2 STAGGERED LAYERS 1/4" GWB ON ONE SIDE OF 6", 18 GA MTL STUDS
@ 16" OC TO DECK, GWB SHALL TERMINATE 6" BELOW DECK; PROVIDE
HORIZONTAL BRIDGING VERTICALLY SPACED AT 48" OC
G6L 2 STAGGERED LAYERS 1/4" GWB ON PHOTOBOOTH SIDE, 112" GWB ON
ONE SIDE OF 6", 18 GA MTL STUDS @ 16" OC TO DECK; GW8 SHALL
TERMINATE 6" BELOW DECK; PROVIDE HORIZONTAL BRIDGING
VERTICALLY SPACED AT 48" OC
G6M 2 STAGGERED LAYERS 114" GWB ON PHOTOBOOTH SIDE, 51&' IMPACT
RESISTANT GWB ON SERVICE 51DE OF 6", 18 GA MTL STUDS @ 16" OC
TO DECK GWB SHALL TERMINATE 6" BELOW DECK PROVIDE
HORIZONTAL BRIDGING VERTICALLY SPACED AT 48" OC
G6N 1/2" GWB ON ONE SIDE OF 64'18 GA MTL STUDS@ 16" O.C. TO SOFFIT
ABOVE
6 7 8 9 10
MIENS WOMENS 1
25 26 A2.3
- 1
NOTE: PROVIDE BLOCKING II
FOR OWNER PROVIDED COAT I
RACK. COORDINATE I L
SEE GENERAL NOTE #8
LOCATION WITH OWNER
CG AND ELEVATION FOR [ED;
PARTITION BLOCKING 21 I -
BREAKROOM
F ® 22 A7.1 0 L
DIMENSION FROM CENTER OF ELQCBIEQPf?✓[tlKJjLG _ _ _ _ _ LEI
CG m COLUMNTOCENTEROF 1 FOUNTAINS, SEE 10/A2.38 E8 /
IGACCORDION PARTITION IPLUMB DWGS
aA m ALIGN 2
0 2.5.1
CG
/ - CG G JANITOR ELECTRICAL PBX
< 24 23 22 I
1IYNEWCOLUMNAT
ACCORDION PARTITION, TY 6 CG
FURRING TO ENCLOSE BASE 0 L
TRAINING PLATE; SEE STRUCT DWGS FUTURE (0) (0) (0)
_ROOM _ _ _i 21 L - -OFFICES_ _
0 1s qz1 n F o CHAT oF 20
Re 21 1 EQ OPERATIONS
K
1e MGR
ALIGN
O O 29
LAND
ERAL NOTE#8
VATION FOR CHAT
IO CGN BLOCKING? CG O > STEELTUBE A7.1 13
/ \ 19 aW] m STIFFENER, TYP. CG
w
GI G CG _ 1, 6, RELOCATED FIRE �'� CG ig 1 SIM 12 2 SERVICE I
Az4 4E Az4 - ■ MGR
HOLD m EXTINGUISHER 1'-6" i ¢ --
'G' CG "' CABINET, SEE G12 '- HOLD CG CG - 4E 28
n - - - - Z CI CHAT- - - -
;Gi / CG I I 18 0 ;o Az4 11' SIR
]II IDF nM'-8Bt PM 1s W 5-aE 9-7 i ■ WRITERS
0
r 8� _y PRESENTATION
oe \ 24 Az1 27 30
j
ALIGN 1� 1 A7.3 •II• A7.1 n SEE GENERAL NOTE#8
14
1 1 EQ 1 E� FUTURE -Ir _ AND ELEVATION FOR 2 A7.2 1
BUYERS A71 15 __ OFFICES m A7.1 9 JL i PARTITION BLOCKING .27
17 0 A7.1
■
N a
�' 18"MIN 16 12'.0" 11'.0" -- qE ALIGN COUNTER
^ I I I I TRANSITION W/
- L- CG - - _ WINDOW OPENING -
°' < BUSINESS 2'-0^
wy-g 4 cG CG CASH A71 OFFICE ■ --------------------------------
4'-10" SEE GENERAL NOTE O OFFICES E-is 9 CG 8 1
S -
#8 AND ELEVATION A70 15
FOR PARTITION
BLOCKING
(j I �
q SIZE FURRING TO CG _ 1
p ACCOMODATE SERVICE 1 -27
lt A74 ELECTRICAL CONDUIT LOUNGE q7,3 6
��I I
AIA I
LINE OF EXISTING
2 SOFFIT TO REMAIN
I
I I
I I
I
RELOCATED FIRE NEW SOFFITTO
EXTINGUISHER MATCH EXISTIN\11i
CABINET, SEE 31.2 CIE ENTRANCE G
cG
- R - - -
11
L /L ll
II I I
- - - - - -
I
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations 4 5
of State and Local Codes
City of Cannel
'LAN -SALES
DATE: 10/14/19
6C (36111 11 2 14 L. all
CG (°) (°) (°)
G 3 �'i qzi SEE GENERAL NOTE#8
5'-4" 10" 4'-3" AND ELEVATION FOR
A7.4 PARTITION BLOCKING E-ia
SIM 3 CG CG
NEW RECESSED
CG FIRE EXTINGUISHER
SEE GENERAL NOTE #8 CABINET, SEE 3/I
Oof 12 AND ELEVATION FOR O CG o PARTITION BLOCKING w
w w l 0'A7.1 1
LGM CHAT CONFERENCE( STORAGE O
MN-10)
I I I
I
I I I I
I I I I
MTL. STUDS
O.C.
WOOD PANELING
1l2" EXTERIOR
E PLYWOOD
ENLARGED PLAN DETAIL - SALES ENTRY PILA:
1 172" = 1'-0"
I
I
I
Iw
W
I�
.¢z
al<�o
z z`¢
/\ EKEIMI_z
I �wz
12.2 13
2 0
� 1 smc2
1
E-39 41
11 1 PHOTOBOOTH A71 I I
2 OPERATOR II I I A2.1
1 39 23 / A7 1
27
I
1 'aaa
II I
PHOTOBOOTH
I 38 I I
I I I
I �
11 I 1
2
38AI
1 LJ �• I
I I
1 L J I
1 EXISTING
RELOCATED
1 STAGING FIRE
(0) 1 37 EXTINGUISHER
-
- --- CORRIDOR - - - - - -J
E-50 50
m ,n
I
LbEXISTING FIRE 1 WOMEN,-�� �
FIRE
(0)
MEN
35
PARTS
34
I I
I I
I
I PARTS
RECEIVING
I 31
I
II
EXISTING FIRE
EXTINGUISHER
LAI
1�RRY
L
flIRR
A R C H I T E C T
IN ASSOCIATION WITH
PIEPER O'BRIEN HERR ARCHITECTS
HERR
ARCHITECT AND IS NET TO HE REPRODUCED IN RHODE OR
IN ROJECT
AND BE RETURNED D..rnreea.. HEuE aireD19 NOT TO BE USED ON ANY �P.°mDNr.aNET VALID UNLESS SIGNED AND RULED
RELEASED FOR CONSTRUCTION
LATEST DAIPC
DRAWN BY: •-
CHECKED BY:
PRODUCTION
MGR PROVIDE NEW I
40 MILLWORKTO
MATCH EXISTING
I
I
I 1
I
I
I
I 1 Z Q pip
1 ' I S SEE
O
I F
a I 0 6 > Q Z
Ir I 'ofIT
(LZqI(Dy)
MEN
�E--32& I p a {w n x J
la 1 N ° a' • F CL
F- ja Z 0
w
7` j as �WZZ
ELECTRICAL W O N a
32 I ass Z MENN Z
MEN
VALVE I
EXISTING FIRE ROOM
EXTINGUISHER 33 I • . , 20-19033
12JULY2019
-32 _ E-33 M
I
1 FLOOR PLAN - SALES
00
I '0_
z 1 �'�
<ZB
�w�
¢x0
m 0
�A2.0