HomeMy WebLinkAboutE101.1GENERAL POWER NOTES 11 12 1 13
I. ALL MOUNTING HEIGHTS REFERENCED SHALL BE TO GETTER OF BOX REFER TO ARCHITECTURAL
ELEVATIONS FOR EXACT
2. IDENTIFY ALL "CLEAN" CIRCUITS FROM PANEL 'LCP' WTN ORANGE TAPE TO ASSURE THAT "ORANGE° LOCATION OF DEVICES.
RECEPTACLES ARE CIROUTED WITH CLEMU POWER
,,/�� 3. ELECTRICAL CONTRACTOR SHALL INSTALL CUTLETS IN FIRE RATED WALLS WITH MINIMIM OF 24• SEPARATION
2 q PER NFPA. OUTLETS WALL NOT BE INSTALLED BACK TO BACK AND ALL OPENINGS SHALL BE SEALED PER — FNOT�@OOnI PB•l,9
L(..• ) s APPROVED UL METHOD. PROVIDE HUBBELL • 11584
SALES Q Q 4. VERIFY ALL FLOOR BOX LOCATICN6 WITH FINAL FURNITURE LAYOUT PRIOR TO STARTING WORD '"—"�E 4 PORT USE RECEPTACLE
LAOR I HENS YIIOMENS I 5. CONTRACTOR SHALL PROVIDE SHALLOW BOXES AS REWIRED M AREAS WITH PJR2IN5 ON CMU WALLS. SECONDCONTROL I
PE' I PB-35
i 2 I 3 11 FM ICE
GF 6. CONTRACTOR SHALL VERIFT ALL RECEPTACLES A� WOWIt4G PROPERLY PRIOR TO FINAL PUNCH. NEW PANEL PIS �D A i/� T TL ,{O 1T T T ^ D
LCPA-26 BR�AKER ( �. PROVIDE EQUIPMENT GEOUNDING CONDUCTOR IN ALL CONDUITS. '""' U0�11 26" iLf-11U L. 1`/1 L1V j-Lj �,
—B.—TSAR JOB COMPLETION ELECTRICAL CONTRACTOR SHALL VERFr ALL RECEPTACLES AND LIGHTING P R O F E $ $ O N A L
PROVIDE • DEMOLITEI BACK TO THEIR ORIGINAL CIRCUIT. B SURFACE MONIED
GFLJ. ..:_• ._...._ �. .. :
FUTURE BR=AKER _ RA•518961 1 6• kBOVE 9. PROVIDE M0 A1G FOR 120 AID 208V CIRCIJIT5 WITH HOMERWS OVER I00' LONG. DISCONNECT SWITCER
BAdCSPCASH PN� SEE DETAIL 2/EU
LCPA-35}l 45 OFFICE `- -_ RA 10. PROVIDE re AUKa FOR p0 AND 200v CIROl1T8 WITH HOMERIN.S OVER 200' LONG. 33
ED
T -64 RA-62
LCPA 25 3 RA-13 WATER HEATEI
2Tty, 6mA/IP .441092E CRABAPPLE RD.
DlsccNNEa w0 rIME NOTE TO CONTRACTOR: 1
F_3 P°4 ALL JUNCTION BOXES, CONDUIT, ETC. FOR OWNER INSTALLED 2
EQUIPMENT SHALL BE COMPEt£LY INSTALLED BY i i/ 9 •
`\ GERTI /
FICATE OF OCCUPANCY MINUS 60 DAYS. ��. p ; eosweu,cA3ao75
F� F ••• / 3 p F NOTE: / j�, ,' , REMOVE ELECTRICAL
/ COUNECTI TO LIFT.
d0 O �A 4 T E E EXPOSED CONDUIT ON WALLS SHALL BE ALLOWED IN THE FOLLOWING ! \ ! RELOCATE O LOCATION
10� Ik RA-51 RA-49 MONITOR 4 4 4 �. _ E 1 AREAS ONLY: / REPRESENT TINE
XISTNG PANELS * t NN. DIRECTED Y CARMAX (770) 992-5077 / (FAX) (770) 992-7593
A-10,12 LCPA-21 I2 RA-29 RA-31 RA-86
-- LCP-3R �'�__ sREiaKER DATA/ 23 ELECTRICAL s t -•• �� ., • 19
TYPO � I LCPaS ANITOR P� ❑J ❑J G UIT TH AREAS SHALLG A S NOTED
Im { p LCPA-Ij OTHErdllISE.
4 �® E I EXPOSED CONDUIT (WHERE PERh11TTED) $HALL EXTEND FROM DEVICE - CAROUSEL MOTOR
1 12 tJ O k ACROCALLY TO SS WALLS JOISTS. CONDUIT SHALL hIOT EXTEND HORIZONTALLY STA ING SEE DETAIL 3/Eu
CPA-22 ! NINO - - .- -- -- -_—_._
LOP-1 LCPA-T J _ .[� _ _--_ OFFICES E E l E 101 ] — —. _—_ -- I --,
_—r--_ I ---I I _—__ _ -- ---_ —_— —_—_—_—_—.—___
p i l -.. jb C E ® LD-53 ) _r.'R SUBMISSION
1 FUTURE I 1 10
R� CO R
-- _
a---- - ��
ER`�� II. E MGM --�
12
'a SHOWROOM
LOP-1
(TYPICAL)
LCPA-I6
!N
NEW FLOOR MTD 1:III A� . RA
LCPA-23
NOTE:
UNLESS NOTED OTHERWISE OUTLETS INSTALLED BENEATH COUNTERS
SHALL BE GROUPED PER DETAIL BELOW. ALL OUTLETS SHALL BE
LOCATED BETWEEN COUNTER SUPPORTS AS SHOWN ON PLANS.
ELECTRICAL CONTRACTOR SHALL COORDINATE SUPPORT LOCATIONS
WITH GENERAL CONTRACTOR PRIOR TO ROUGH -IN. PROVIDE OFFSET
BRACKETS AS REQUIRED. SIMPLY MOUNTING BOX DIRECTLY TO
NEAREST STUD IS NOT ACCEPTABLE
8'
REGULAR 4 IS
RECEPTACLEE
III SUPPORT
WITH GC
NOTE:'
CONTRACTOR SHALL PROVIDE SEPARATE NEUTRAL CONDUCTOR FOR
EACH 120V OR 211V UNGROUNDED CONDUCTOR EACH NEUTRAL
CONDUCTOR SHALL HAVE A COLOR STRIPE MATCHING THE
RESPECTIVE UNGROUNDED CONDUCTOR COLOR NO SHARED
NEUTRALS ALLOWED. PROVIDE EQUIPMENT GROUNDING CONDUCTOR IN
ALL CONDUITS.
Fa
IN
t
RA-PJ4
im
i
•E
POLO -
POLE -
_
28
NEI
OR NEI
FOR
�E
SERVICE
WRITERS
I
I
EIJ
TIC I CV I-V Pc INl.", I CJ (APPLY TO THIS SHEET ONLY(
OI REPLACE EXISTNG FLOOR OUTLET WITH NEW FLOOR OUTLET DESCRIBED IN SYMBOL LEGEND E01 RE-U5E
EXISTING RACEWAYS SERVING THIS LOCATION
OPROVIDE A SEPARATE HCMER)N CONDUIT TO PAELBOARD FOR EACH SECTION OF WIREMOLD UNLESS
NOTED OTHERUISE, OV,I R TOR SHALL 8171.8 CONDUIT INTO BOTTOM OF UREMOLO AND INSTALL
CQmUIT IN SLAB (SEE DETAIL 10/E20).
153 INSTALL DUPLEX RECEPTACLE BEHIND MONITOR
4 GANG DUPLEX RECEPTACLES UNDER COMMON COVERPLATE,
REMOVE 4 REINSTALL DEVICES AS REWIRED IN BUSINESS OFFICE TO ACCOMMODATE NEW MILLWORK
COORDINATE SCOPE WTH ARCHITECTURAL DRAWINGS AND MILLWORC CONTRACTOR
6 NOT USED.
M CONTRACTOR SHALL REUSE EMSTNG CIRMITS WHERE AVAILABLE.
8 UUREMOLO WITH DEVICES INSTALLED WHERE SHOWN (INSTALL PER DETAIL I MZ)..
9 NOT USED.
10 RELOCATE R'IU 7HERIO5TAT$ AS DIRECTED BY MECHANICAL DRAWINGS,
II CONTRACTOR SHALL SURVEY COLUMN LOCATIONS TO DETERMINE WIREMOLD LENGTHS.
11 REFER TO ARCHITECTURAL ELEVATIONS FOR SPECIAL MOUNTING HEIGHT.
OPROVIDE NEMA L5-20R IG RECEPTACLES. CONNECT TO A NEW 2O MP BREAKER IN EXISTING PANEL
LCP. MOUNT ADJACENT TO EXISTING TWIST LOCK RECEPTACLE
14 PROVIDE NEMA L14-3OR RECEPTACLES. CONNECT EACH TO A NEW 30A/2P BREAKER N EXISTING
PANEL LCP. e3` 10 4 I 00 G- IR'C, REQUIRES NEUTRAL) MOUNT ADJACENT TO EXISTING TWIST LOOC
RECEPTACLES.
15 NOT USED.
IS SORE DEVICES ARE M084TED A 3V HORIZONTALLY. REFER TO AROHITECTURAL ELEVATION FOR DEVICE
LOCATIONS IN BUYERS.
M REFER TO STRUCTURAL DRAWMG3 FOR TRENCHING R=W IREMENTS AND LIMITATIONS FOR FLOOR OUTLETS
AND ASSOCIATED RACEWAYS.
IB CAROUSEL CONTROLLER WITH DISOONECT SWITCH. COORDINATE WITH EQUIPMENT VENDOR FOR EXACT
LOCATION AND REQUIREMENTS PRIOR TO ROUS4.11N.
OCOORDINATE EXACT REQUIREMENTS FOR ROLL -UP DOOR AND CONTROLS PRIOR To ROUGH-M. DOOR
CONTROLS SHALL BE WIRED 'ONE TOUCH° OPERATION IN LIEU OF "HOLD AND RELEASE" CONTROL,
SEE DETAIL 5/E20.
® REMOVE ELECTRICAL SERVICE TO REMOVED EXHAUST FANS IN THIS AREA COORDINATE WITH DIVISION 8.
21 NOT USED.
22 ALL DEVICES AND COVERPLATES IN PHOTO BOOTH AREA SHALL BE WHITE.
3 PROVIDE CONNECTION BETWEEN UPS N PBX OUTLETS M IDF CLOSET. REFER TO DETAIL 2/E30 GE1
QEXHAUST FAN - PROVIDE RELAY AID WIRING SUCH THAT FAN IS CONTROLLED BY ONE (1) ROW OF PHOTO
STATION LIGHTS.
0
l oil iol
208V POWER CONDUCTOR BY
2n 9
DISC
LLPO DDD
3 PHASE MOTOR
CONDUCTOR
BY CONTRACTOR
WIRE
MANAGEMENT
VFD
PLC
TERMINAL BLOCK
ROTARYCON
nwTw
EXISTING
RECEIVING
31 -]
13
CONTRAOTC
MOTOR POWER
CONNECTION BOX
♦ 5
I.ECTRICALHo
I L
32
HB
HA VALVE
SLE R�
BY CAROUSEL
�}+r'✓I 117— CONDULETS
PVC RIGID
R�IG71�D STEEL CONWIT
4• ABOVE PIT FLOOR
3 CAROUSEL MOTORFIT
EI-I 5CALE: NTS
THISDRAWING ISTHE PROPERry OF CRNO L MOWN P.E.
AND IS NOT TO BE REPRODUCED IN WHOLE OR PPa
WHOLM OR IN PART, R IS NOT TO BE USED ON ANY OTHI
PROJECT AND SHAY- BE RETURNED UPON REQUEST. COF
FLIGHT AS DATED CRAIQ L MOLNAR P.E. NOT VALID UNLESS
RELEASED FOR CONSTRUCTION
'�
O
ON
`
FINF
Q
�
a
z
z
BE
�7
cc
'
Na
�
~=J
f
w
O
an
Q
BEWZZ
W
€g
WINN
p�a
A3
Z
w
OL
z
PIIROJECT N0.�20-19033
DATE�UJULY2019
CEEMMEt
BUILDINGSALES
POWER
PLAAL
RELEASED FOR CONSTRUCTION
Subject to compliance with all n:gulations
of State and meal Codes
City of Cannel
�Nq�I�IanglaWL
DATE: 10/14/19
SHEET NO.