HomeMy WebLinkAboutP103.0CAULK AND SEA
SPACE BETWEEN
NOTE: WHERE PIPING IS EXPOSED AT FNISHED WALLS, FLASH
MOUNT SLEEVE AND FROADE EWITC14ECN PLATE.
INT RIO
3
PIPE
SLEEVE
DETAIL
P3.0
SCALE: NOT
TO SCALE
HANGER ROD SUPPORT DISTANCE
MATERIALS
TYPE OF JOINTS
HORIZONTAL
VERTICAL
5 FEET EXCEPT MAY BE 10 FEET UHEIE
BASE AND EACH FLOOR NOT TO
CAST IRON HUB
LEAD AND OAKUM
10 FOOT LENGTHS ARE INSTALLED L I. a
EXCEED 15 FEET
AND SPIGOT
EVERY OTHER JOINT, UNLESS OVER 4 FEET
BASE AND EACH FLOOR NOT TO
COMPRESSION GASKET
THEN SUPPORT EACH JOINT L 2.3
EXCEED 15 FEET
OAST IRON HUB-
SHIELDED COUPLING
EVERY OTHER JOINT, UNLESS OVER 4 FEET
BABE AND EACH FLOOR NOT TO
LEBO
THEN SUPPORT EACH JOINT L 2, 3, 4
EXCEED 15 FEET
COPPER TUBE
SOLDERED, BRAZED OR
H W" AND SMALLER 6 FEET
EACH FLOOR NOT TO EXCEED
AID PIPE
WELDED
2" *0 LARGER 10 FEET
I0 FEET a
L SUPPORT ADJACENT TO JOINT, NOT TO EXCEED 18"
2. BRACE AT NOT MORE THAN 40' INTERVALS TO PREVENT HORIZONTAL MOVEMENT
3. SUPPORT AT EACH HORIZONTAL BRANCH CONNECTION
4. HANGERS SHALL NOT BE PLACED ON THE COUPLING
5. VERTICAL WATER LINES MAY BE SUPPORTED N ACCORDANCE WITH RECOGNIZED ENGINEERING PRINCIPLES WITH REGARD TO
EXPANSION AND CONTRACTION, WHEN FIRST APPROVED BY THE ADMINISTRATIVE AUTHORITY
iim
PLUMBINGFIXTURE SCHEDULE
SM SPECIFICATIONS SECTION 8450
MARL
FIXTURE TYPE
DESCRIPTION
WASTE
VENT
HID
CID.
MANUFACTURER
FIXTURE: AMERICA14 STANDARD 345100E MADERA B'H HET
P-1
WATER CLOSET (GENERAL USE)
U OFF. WHITE KID FESISTING VITREOUS CHINA WITH EVERCLEAL FLOOR MOUNTED,
4'
2"
P
VALVE: AMERCAA 6041.11E
FLOOR OUTLET, ELONGATED BOUL, TOP SFUC, AND CHROME FINISH FLUSH VALVE
SEATFLUI
BEAT: AI'ffRCNI STANDARD 5901100 OPEN FRONT LE88 COVER
D SWUM
P-N
WATER CLOSET (ADA)
U GPF. UNITE KID RESISTING VITREOUS CHINA WITH EVERCLEAN, FLOOR MOUNTED,
4.
2"
-
1.
FIXTURE: AMERICA N STANDARD 3461MI MADERA 165" H HET
FLOOR OUTLET, ELONGATED BOLL, TOP SPUD, AND GWROME FNISH FLUSH VALVE
FLUSH VALVE: AMIERICAN STANDARD 6041.111
SEAT: AMERCAN STANDARD 5WI100 OPEN FRONT LESS COVER
P-2
URINAL
125 GPF. WHITE KID RESISTING VITREOUS CHINA WITH EVERCLEAL ULALL AM, 3/4' TOP SPUD,
2.
24
-
3/4'
FIXTURE: AMERICAN STANDARD 65WOVIEC
WASHOUT TO -FLOOR FIXTURE SUPPORT AND FLASH VALVE. INSTALL
FLUSH VALVE: SLOAN 060125
P-214
URINAL (ADA)
ADA LIP w 11" AFF, OTHERS a 24" AFF
FIXTURE SUPPORT: J. R. SMITH OR EQUAL
METERING3 FAUCET, I-V4' GRID DRAIN, WITH I -VI' OD. TAILPIECE, CHROME
FIXTURE: MOLDED SIMILE PIECE W/COUNIER SEE ARCH.
P-3
LAVATORY - COUNTERTOP (ADA)
PLATED BRASS 1-1/2" 'P' TRAP WITH CO. AND CHROME PLATED WHEEL STOPS. WITH
11/24
1-1/2"
IR'
IR"
FAUCET: CHICAGO FAUCET 3600-E2805AB METERING, SELF -CLOSE
FLEXIBLE RISERS. (05 GPM FLOW)
TEMPERATURE ADJUST, 25 GAL/CYCLE MAX, ADA, PRESSURE
COMPENSATING, INSULATION KIT: TRUEBRO-LAV GUARD
FUR NI5H WITH POU.ERB LFG480-00 THERMAL MIXING VALVE. TEMPERATURE SET 1057
U SECOND CYCLE
TYPE 302 STAINLESS STEEL, MIN 18 GAUGE, SOUND DEADENED, SELF -RIMMING, FOUR HOLE
FIXTURE: ELKAY GLRAD-3319-60 (6" DEEP)
15-4
1110 COMPARTMENT SINK
FAUCET DRILLING, HI -ARC FAUCET, GIP STRAINER WITH 1-112" OD. TAILPIECE,
I-1/2'
2' on
N'
FAUCET: DELTA 21SWF WITH HAND HELD SPRAY, 1.0 GPM AERATOR
CHROME PLATED BRASS 1-1/2" 'P' TRAP WITH CO. AND WHEEL STOPS
ADA FLAT SPEC FOR FAUGEi
WITH FLEXIBLE RISERS. PROVIDE GARBAGE DISPOSAL.
NOTE: - ALL PLUMBING FIXTURES, EQUIPMENT, TRIM, AND FITTINGS SHALL COMPLY WITH LOCAL,STATE, AND FEDERAL REGULATIONS AND CODES, INCLUDING BUT NOT LIMITED TO, WATER
AND ENERGY CONSERVATION CODES. THE SCHEDULED AND/OR SPECIFIED PLUMBING FIXTURES AND EQUIPMENT REPRESENT THE MINIMUM CRITERIA AND SHALL BE THE BASIS FOR THE
CONTRACTOR'S BASE BID. IF THE SCHEDULED OR SPECIFIED FIXTURES OR EQUIPMENT CONDIT COMPLY WITH GOVERNING CODES OR REGULATIONS IN ALL RESPECTS, THE CONTRACTOR
844ALL PROVIDE AN ALTERNATE BID FOR COMPLYING FIXTURES, EQUIPMENT, TRIM, OR FITTING6. THE ABSENCE OF AN ALTERNATE BID SHALL BE CONSTRUED i0 MEAN THAT THE CONTRACTOR'S
BID INCLUDES ALL COSTS NECESSARY TO MEET ALL REGULATIONS AND CODES.
i ONE ANGLE ON EACH
MOO 4200 OR 255 JOIST CLAMP SIDE O WEB MEMBERS
REST ON TOP OR NETT NIT HANGER ROD
WITH SET SCREW OR EQUAL BOTTOM CHORDS STEEL
TOP CHORD HAVER NUT rL JOISTS BETWIM4 PANEL
O' STEEL JOIST I I r-/ POINTS, SIZE FOR LOAD CONCRETE INSERT
OF STEEL JOIST
HEAVY DUTY CONCRETE
STEEL INSERT WITH
ELONGATED STRAP
ELECTRIC WATER HEATER SCHEDULE
MARK TYPE MANUFACTURER MODEL NO. STORAGE RECOVERY KW TEMP. ELECTRICAL AREA SERvED
GALLONS
UH-I ELECTRIC CHR NIOMITE SR-30 - 51F RSE a US GFM 83 - 211A BI:EAKROOM
3/8"HW SUPPLY
TO FAUCET
PLUMBING FD(TUF'E
- 3/8" CUU SUPPLY
TO FAUCET
STOP VALVE
WEB MEMBERS
CONCRETE JOIST ELECTRIC 114-1
WHERE SHUN INSTANTANEOUS
WATER HEATER
WALL MOUNTED p_7RAp
HMYaER NUL / WITH GO- PLUCs
I I FINISHED FLOOR
BENT STRAP 1-1/2" X
3/11 OVER VERT
LEGS OF ANGLES
STEEL JOIST
HANGER ROD SCHEDULE
FIFE SIZE
ROD SIZE
I/1" TO 4"
3/8" CIA
5' TO 8'
V2" CIA
I& TO 12"
5/84 DIA
HANGER F
SUPPORT
IffAVY DUTY
CLEVIS HANG
PIPE
CLEVIS HANGER
SINGLE HORIZONTAL RUNS
NO VAPOR 5ARRIER INSUL
HEAVY DUTY CONC
JOIST CLAMP
HANGER ROD
HMYaER ROD
CONCRETE JOIST
LOCKING NUT
SUPPORT NUT
HEAVY DUTY
CLEVIS HANGER
STRUCTURAL STEEL
BEAM (SEE PROJECT
VAPOR BARRIER
PLANS FOR SIZE
INSULATION
HEAVY DUTY
BEAM CLAMP
16 GA ZINC COATED
SHEET STEEL SADDLE
EYE SOCKET
AT LEAST 8" LOG
HANGER ROD
CLEVIS HANGER STEEL BEAM
SINGLE HORIZONTAL RUNS
WITH VAPOR BARRIER INSUL
4 PIPE HANGING DETAIL
P3.0 NOT TO SCALE
P3.0 ELECT, WATER HEATER
NOT TO
PLUMBING LEGEND
— —
EXISTING COD WATER
—
COLD WATER
— — — E5 — —
EXISTINS SANITARY
8
SANITARY
EY
EXISTING VENT
VENT
HOT WATER
EXISTING HOT WATER
BALL VALVE
DUAL CHECK
N
PLUMBING NOTES
L Field verlib location of existing water and waste I ver t pipe
2. Forman appropriate adaptors for connection of dissenter piping notarial.
3. peter pipe shall be type L capper with soldered Fittlrcjs.
4. Waste, and vent pipe above the slab shall be hlbless rest Iron or OW copper.
Mew and Vert pipe below the slab shall be Schedule 40 ASTM 2665 PVC
with solvers weld fitNgs.
S. Domestic hot and cold water pipe shall be Insulated with
W' thick fiberglass pipe Im Ration with all aarvicie Jackal.
6. New vents thau roof to be held a mineeun of lo rest Rom ary RTU Wtetde
air Intake.
ICE MAKER BOX GUY GRAY BIM 015
WITH 42"%IA' CO'IFRESSION AYGLE VALN
N"CO•IBNATION
MPT BRASS SWEAT
CONNECTION
VI"PIPE OR
COPPER TUBING
IBM AFF.
1 ICE MAKER BOX DETAIL
P3.0 NOT TO SCALE
AM CERRA JR. PE
1827 POWERS FERRY RD.
BLDG. # 18, SUTE #100
ATLANTA, GA 30339
PH OTO)980-0581
21956.01
7/12/19
THIS DRAWING IS THE PROPERTY OF A M. CERRA JR.
P.E. AND IS NOT TO BE REPRODUCED IN WHOLE
CA IN PART, IS NOT TO BE USED ON ANY OTHER PROJECT
AND SHRL BE RETURNED UPON REQUEST. COPYRIGHT AS
DATED A.M. CERRA JR. P.E. IS NOT VALID UNLESS
SIGNATURE AND SEAL ARE PRESENT.
SUBMISSION
RELEASED FOR CONSTRUCTION
LAIb2S1 UAIP6
DRAWN BY:
CHECKED BY:
V
z
aDO
�W
to
INN
��
>
a
s =
Z
fA
=3D~FLU
N
�
0
7
W
z
Z
Z
OC
Q
LU
W
zeH0Ln
H
�H
Z
Ises
0)
Z
0)
20-19033
12JULY2019
SCHEDULES, NOTES,&
DETAILS - PLUMBING
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City of Carmel
�N;T�vJIBw�,ORS�
DATE: 10/14/19
SHEET N0.