HomeMy WebLinkAboutA111 ARCH -ELEC - DOOR SCHEDULEDOOR SCHEDULE # DIMENSIONS DOOR FRAME HARDWARE REM, 01 EXISTING TYPE MATERIAL FINISH - ITYPEIMATERIALI - -- FINISH -- - R1 - -- 11 3'-G'x7'-0"x13/4" D1 SOLID CORE BIRCH VNR. STAIN TO MATCH EXIST. F3 TIMELY MATCH EXIST. CR, ES, SL. CL R2 12 RELOCATED - - - - -- -- OL R2 13 3'-G'x7'-O'X13/4" D1 SOLID CORE BIRCH VNR. STAIN To MATCH EXIST. F4 TIMELY EXIST. OL R2 16 3'-0"x7'-0"x1 Yy' D1 SOLID CORE BIRCH VNR. STAIN TO MATCH EXIST. F2 TIMELY MATCH EXIST. OL R2 DOOR/FRAME TYPES I FLUSH BEAD STAINED TO MATCH DOOR N TJ 0 0 FO D1 F1 t o-t tl• .2,_9' 2. 2�_8, t S i F3 REMARKS Y y�TEYPERED CLASS F2 F4 HARDWARE LEGEND RE DESIGN INTENT IS FOR EXISTING DOOR TO BE REUSED AND CL CLOSER MODIFIED TO MATCH DOOR TYPE "DI". CH COAT HOOK OR CARD READER BY TENANT (N.I.C.) IRS. DESIGN INTENT IS FOR WINDOW AND OR DOOR FILM TO MATCH DB DMMY Li TENANT'S EXISTING FILM STANDARD. COORDINATE WITH TENANT DL DUUMMY LEVER ON EXACT FILM LOCATIONS. EL ELECTROMAGNETIC LOCK )PER IBC 2012) DOOR/FRAME NOTES H5 ELECTRIC ENRIKE BYTENANT ,N.LG.' KP KICK PLATE KS KICK STOP I. REUSE DOORS FROM DECONSTRUCTION WHERE POSSIBLE; TOUCH UP OL OFFICE LOCKSEF EXISTING DOOR STAIN AS REQUIRED. PROVIDE NEW BUILDING STANDARD PH PANIC HARDWARE DOORS MATCHING EXISTING VENEER AS REQUIRED. STAIN NEW DOORS PL PRIVACY LOCKSET TO MATCH EXISTING. PRE -MACHINE NEW DOORS FOR CYLINDRICAL PP PUSH/PULL LOCKSETS, PS PASSAGE LATCHSET PV PIVOT HINGE 2. PROVIDE NEW HARDWARE TO MATCH EXISTING ON NEW DOORS. REUSE RL ROLLER LATCHES EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE. FOR NEW SL STOREROOM LOCKSET DOOR HARDWARE, PROVIDE GRADE 2 MINIMUM BUILDING STANDARD, TS TOP STRIKES PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND LATCHSETS. 3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED, REUSE EXISTING FROM DEMOLITION WHERE POSSIBLE. IF FRAMES ARE NOT BEING REPAINTED, TOUCH UP EXISTING FRAMES TO BE REUSED. 4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL CORNERS UNLESS OTHERWISE NOTED ON PLAN, 5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND LOCKSETS. 6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION, PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES. ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS. 7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS: • 7'0" HT. TO HAVE 3 HINGES • GREATER THAN 7' 0" IN Hi, TO HAVE 4 HINGES • FINISH TO MATCH HARDWARE SET 8. PROVIDE (I) SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE NOTED. 9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL STOP. RELEASED FOR CONSTRUCTION Subject to compliance with all regulation of State and Local Codes City Df Centel (� �NI��V'�0*4:YtAMI_ DATE: \ 10/14/19 ELECTRICAL LEGEND NEW CONSTRUCTION EXISTING TO REMAIN :al POWER OUTLET, DUPLEX POWER OUTLET, DUPLEX DATA/COMMUNICATION 14 OUTLET )PROVIDE BOX b DATA/COMMUNICATION ND APULL STRING ONLY) OUTLET DIED DEDICATED CIRCUIT GFCI GROUND FAUL1 CIRCUIT INTERRUPT OUTLET +42" HEIGHT OF ELECTRICAL OR DATA DEVICE ELECTRICAL PLAN NOTES E01 PROVIDE POWER AS REQU I RED FOR ELECTRIC STRIKE AT DOOR FOR CARD READER (CARD READER BY TENANT). COORDINATE WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE FOR MORE DETAILS. E02 EXISTING ELECTRICAL IN THIS LOCATION TO REMAIN. COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE E03 DEDICATED RECEPTACLE AS REQUIRED. E04 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN, COORDINATE EXACT LOCATION WITH TENANT. ARCHITECTURAL LEGEND NEW CONSTRUCTION EXISTING TO REMAIN mr WALL WALL PARTIAL HEIGHT WALL ® PARTIAL HEIGHTWALL II w WINDOW/SIDELIGHT ate¢ WINDOW/SIDELIGHT ® DOORAND FRAME )SEE DOORSCHEDULE) DOOR AND FRAME NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. WALL TYPES NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE W1 UNLESS OTHERWISE NOTED. PROVIDE MOISTURE R ITANT/ GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. F STANDARD WALL 31/8" METAL STUDS AT 16" O.C.; ONE LAYER OF 6X TYPE"X'GYPSUM BOARD EACH SIDE: EXTEND WALL TO UNDERSIDE OF CEILING 35/8" METAL STUDS AT 16 INSULATION 2 WALL WITH IN 6"O.C.: ONE LAYER OF S/'TYPE "X'GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING I�DEMISING WALL TO DECK WITH INSULATION 36%' METAL STUDS AT 16" O.C.: ONE LAYER OF S/g"TYPE'X" GYPSUM BOARD GENERAL NOTES I. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. 2. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 3. ALL OUTLETS ARE TO INSTALLED 18" MIN, A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL NEW DEVICES AND FACE PLATES TO MATCH EXISTING. 4. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI, 5. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. METAL STUD EXISTING WIN MULLION ARCHITECTURAL PLAN NOTES A01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. A02 RELOCATE EXISTING WINDOWS AND FRAMES FROM DECONSTRUCTION AT THIS LOCATION. A03 NEW BRUSHED ALUMINUM FIRE EXTINGUISHER RECESSED CABINET TO BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE PROVIDED BY TENANT AND INSTALLED ACCORDING TO NFPA 10. A04 CONTRACTOR TO CONFIRM EXISTING FIRE EXTINGUISHER IS IN PROPER WORKING ORDER AND INSTALLED ACCORDING TO NFPA 10. A06 NOTUSED. . A06 CONFIRM THAT EXISTING WALLMATCHES WALLTYPE"W2". IF NOT, ALTER EXISTING WALLAS REQUIRED TO MATCH "W2'. WALL THICCKKNEESS PRE -FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT %A/A 11 A9P AAI II I1�AI M1 9PA IL LE ® AREA NOT IN CONTRACT ARCHITECTURAL He ELECTRICAL PLAN ❑ AREA OF WORK 0 2' 4' 8' 16' N C THIS DRAWING. AND TiE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOTTO BE USED OR REPRODUCED IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. O O N W W IV � 111111� N N Zoe J m �O O J z Q Z J O I -I-' ZQ OW �U mommomm IV Z O � O Ln L0 ISSUE DATE DESCRIPTION 08.28.19 REVIEW SET 09.03.19 PERMITSET REVISIONS MARK RIPTION PROJECT NUMBER 2019.330 DRAWN BY CRB 2ND FLOOR ARCH. PLAN/ ELECTRICAL PLAN/ DOOR SCHEDULE Al I I