HomeMy WebLinkAboutA111 ARCH -ELEC - DOOR SCHEDULEDOOR SCHEDULE
# DIMENSIONS DOOR FRAME HARDWARE REM,
01
EXISTING
TYPE
MATERIAL
FINISH
-
ITYPEIMATERIALI
-
--
FINISH
--
-
R1
-
--
11
3'-G'x7'-0"x13/4"
D1
SOLID CORE
BIRCH VNR.
STAIN TO
MATCH EXIST.
F3
TIMELY
MATCH
EXIST.
CR, ES, SL. CL
R2
12
RELOCATED
-
-
-
-
--
--
OL
R2
13
3'-G'x7'-O'X13/4"
D1
SOLID CORE
BIRCH VNR.
STAIN To
MATCH EXIST.
F4
TIMELY
EXIST.
OL
R2
16
3'-0"x7'-0"x1 Yy'
D1
SOLID CORE
BIRCH VNR.
STAIN TO
MATCH EXIST.
F2
TIMELY
MATCH
EXIST.
OL
R2
DOOR/FRAME TYPES
I
FLUSH BEAD
STAINED TO
MATCH DOOR
N
TJ
0
0
FO
D1 F1
t o-t tl•
.2,_9' 2. 2�_8,
t
S
i
F3
REMARKS
Y
y�TEYPERED
CLASS
F2
F4
HARDWARE LEGEND
RE DESIGN INTENT IS FOR EXISTING DOOR TO BE REUSED AND
CL
CLOSER
MODIFIED TO MATCH DOOR TYPE "DI".
CH
COAT HOOK
OR
CARD READER BY TENANT (N.I.C.)
IRS. DESIGN INTENT IS FOR WINDOW AND OR DOOR FILM TO MATCH
DB
DMMY Li
TENANT'S EXISTING FILM STANDARD. COORDINATE WITH TENANT
DL
DUUMMY LEVER
ON EXACT FILM LOCATIONS.
EL
ELECTROMAGNETIC LOCK )PER IBC 2012)
DOOR/FRAME NOTES
H5
ELECTRIC ENRIKE BYTENANT ,N.LG.'
KP
KICK PLATE
KS
KICK STOP
I. REUSE DOORS FROM DECONSTRUCTION WHERE POSSIBLE; TOUCH UP
OL
OFFICE LOCKSEF
EXISTING DOOR STAIN AS REQUIRED. PROVIDE NEW BUILDING STANDARD
PH
PANIC HARDWARE
DOORS MATCHING EXISTING VENEER AS REQUIRED. STAIN NEW DOORS
PL
PRIVACY LOCKSET
TO MATCH EXISTING. PRE -MACHINE NEW DOORS FOR CYLINDRICAL
PP
PUSH/PULL
LOCKSETS,
PS
PASSAGE LATCHSET
PV
PIVOT HINGE
2. PROVIDE NEW HARDWARE TO MATCH EXISTING ON NEW DOORS. REUSE
RL
ROLLER LATCHES
EXISTING HARDWARE ON EXISTING DOORS WHERE POSSIBLE. FOR NEW
SL
STOREROOM LOCKSET
DOOR HARDWARE, PROVIDE GRADE 2 MINIMUM BUILDING STANDARD,
TS
TOP STRIKES
PROVIDE A.D.A. ACCESSIBLE LEVER HANDLES ON NEW LOCK AND
LATCHSETS.
3. PROVIDE NEW BUILDING STANDARD FRAMES AS REQUIRED, REUSE
EXISTING FROM DEMOLITION WHERE POSSIBLE. IF FRAMES ARE NOT BEING
REPAINTED, TOUCH UP EXISTING FRAMES TO BE REUSED.
4. FRAME ALL DOOR ROUGH OPENINGS 4" FROM ADJACENT WALL
CORNERS UNLESS OTHERWISE NOTED ON PLAN,
5. REFER TO TENANT AND LANDLORD FOR KEYING REQUIREMENTS AND
LOCKSETS.
6. TENANT'S SECURITY VENDOR IS RESPONSIBLE FOR THE SPECIFICATION,
PURCHASE, AND INSTALLATION OF ALL ACCESS CONTROLLED
ELECTRONIC AND/OR MAGNETIC HARDWARE AND ASSOCIATED DEVICES.
ALL SPECIFICATIONS AND INSTALLATIONS MUST COMPLY WITH THE
INDIANA BUILDING CODE, CHAPTER 10, MEANS OF EGRESS.
7. PROVIDE BUTT HINGES ON ALL DOORS AS FOLLOWS:
• 7'0" HT. TO HAVE 3 HINGES
• GREATER THAN 7' 0" IN Hi, TO HAVE 4 HINGES
• FINISH TO MATCH HARDWARE SET
8. PROVIDE (I) SET OF SILENCERS ON ALL DOOR FRAMES UNLESS OTHERWISE
NOTED.
9. PROVIDE WALL STOP (FLOOR STOP WHERE APPLICABLE) AT EACH DOOR
UNLESS OTHERWISE NOTED. PROVIDE WOOD BLOCKING BEHIND WALL
STOP.
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulation
of State and Local Codes
City Df Centel (�
�NI��V'�0*4:YtAMI_
DATE: \ 10/14/19
ELECTRICAL LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
:al POWER OUTLET, DUPLEX POWER OUTLET, DUPLEX
DATA/COMMUNICATION
14 OUTLET )PROVIDE BOX b DATA/COMMUNICATION
ND APULL STRING ONLY) OUTLET
DIED
DEDICATED CIRCUIT
GFCI
GROUND FAUL1 CIRCUIT
INTERRUPT OUTLET
+42"
HEIGHT OF ELECTRICAL
OR DATA DEVICE
ELECTRICAL PLAN NOTES
E01 PROVIDE POWER AS REQU I RED FOR ELECTRIC STRIKE AT DOOR
FOR CARD READER (CARD READER BY TENANT). COORDINATE
WITH TENANT'S SECURITY CONTRACTOR. SEE DOOR SCHEDULE
FOR MORE DETAILS.
E02 EXISTING ELECTRICAL IN THIS LOCATION TO REMAIN.
COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE
E03 DEDICATED RECEPTACLE AS REQUIRED.
E04 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED
TELEVISION AT HEIGHT NOTED ON PLAN, COORDINATE EXACT
LOCATION WITH TENANT.
ARCHITECTURAL LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
mr
WALL
WALL
PARTIAL HEIGHT WALL
®
PARTIAL HEIGHTWALL
II
w
WINDOW/SIDELIGHT
ate¢
WINDOW/SIDELIGHT
®
DOORAND FRAME
)SEE DOORSCHEDULE)
DOOR AND FRAME
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
WALL TYPES
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE W1 UNLESS OTHERWISE NOTED.
PROVIDE MOISTURE R ITANT/ GREEN BOARD AS REQUIRED IN
RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
F STANDARD WALL
31/8" METAL STUDS AT 16" O.C.;
ONE LAYER OF 6X TYPE"X'GYPSUM BOARD
EACH SIDE:
EXTEND WALL TO UNDERSIDE OF CEILING
35/8" METAL STUDS AT 16
INSULATION
2 WALL WITH IN 6"O.C.:
ONE LAYER OF S/'TYPE "X'GYPSUM BOARD EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
I�DEMISING WALL TO DECK
WITH INSULATION
36%' METAL STUDS AT 16" O.C.:
ONE LAYER OF S/g"TYPE'X" GYPSUM BOARD
GENERAL NOTES
I. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR
WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL
FINISH. REFER TO MANUFACTURER RECOMMENDATIONS.
2. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION
OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL
DIMENSIONS.
3. ALL OUTLETS ARE TO INSTALLED 18" MIN, A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL
NEW DEVICES AND FACE PLATES TO MATCH EXISTING.
4. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI,
5. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED
TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES
AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE
EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL
CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL
WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED
AND MUST COMPLY WITH ALL APPLICABLE CODES.
METAL STUD
EXISTING WIN
MULLION
ARCHITECTURAL PLAN NOTES
A01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS
EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE
WITH EXISTING WALLS.
A02
RELOCATE EXISTING WINDOWS AND FRAMES FROM
DECONSTRUCTION AT THIS LOCATION.
A03 NEW BRUSHED ALUMINUM FIRE EXTINGUISHER RECESSED CABINET TO
BE PROVIDED AND INSTALLED BY CONTRACTOR. ALL FIRE
EXTINGUISHERS ARE TO BE PROVIDED BY TENANT AND INSTALLED
ACCORDING TO NFPA 10.
A04 CONTRACTOR TO CONFIRM EXISTING FIRE EXTINGUISHER IS IN PROPER
WORKING ORDER AND INSTALLED ACCORDING TO NFPA 10.
A06 NOTUSED. .
A06 CONFIRM THAT EXISTING WALLMATCHES WALLTYPE"W2". IF NOT,
ALTER EXISTING WALLAS REQUIRED TO MATCH "W2'.
WALL
THICCKKNEESS
PRE -FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
%A/A 11 A9P AAI II I1�AI M1 9PA IL
LE
® AREA NOT IN CONTRACT ARCHITECTURAL He ELECTRICAL PLAN
❑ AREA OF WORK 0 2' 4' 8' 16' N C
THIS DRAWING. AND TiE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOTTO BE
USED OR REPRODUCED IN WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
O
O
N
W
W
IV
�
111111�
N
N
Zoe
J
m
�O
O
J
z
Q
Z
J
O
I -I-'
ZQ
OW
�U
mommomm
IV
Z
O
�
O
Ln
L0
ISSUE
DATE DESCRIPTION
08.28.19 REVIEW SET
09.03.19 PERMITSET
REVISIONS
MARK RIPTION
PROJECT NUMBER
2019.330
DRAWN BY
CRB
2ND FLOOR
ARCH. PLAN/
ELECTRICAL PLAN/
DOOR SCHEDULE
Al I I