Loading...
HomeMy WebLinkAboutS101.0GENERAL NOTES: STEEL NOTES: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BRACING DURING CONSTRUCTION. PROVIDE ADEQUATE SHORING OR BRACING DURING CONSTRUCTION TO RESIST ALL REQUIRED FORCES SUCH AS (BUT NOT LIMITED TO) DEAD LOADS, LIVE LOADS, SOIL PRESSURES, CONSTRUCTION LOADS, WIND AND UNBALANCED LOADING. PROVIDE TEMPORARY SAFETY ENCLOSURES AS NECESSARY TO PROTECT ALL PERSONNEL INVOLVED WITH THIS PROJECT. 2. DETAILS NOT SHOWN SHALL BE ACCORDING TO: AMERICAN INST. of STEEL CONSTR. A.I.S.C. SPECS FOR STRUCTURAL STEEL AMERICAN CONCRETE INSTITUTE A.C.I. SPECS FOR CONCRETE AMERICAN WELDING SOCIETY A.W.S. SPECS FOR WELDING NATIONAL CONCRETE MASONRY ASSOCIATION N.C.MA SPECS FOR CONCRETE MASONRY STEEL JOIST INSTITUTE S.J.I. SPECS. FOR STEEL JOISTS AMERICAN IRON & STEEL INSTITUTE A.I.S.I. SPECS FOR COLD FORMED STEEL 3. CONTRACTOR SHALL REVIEW SHOP DRAWINGS AND VERIFY ALL DIMENSIONS PRIOR TO SUBMITTING SAME TO ARCHITECT AND/OR ENGINEER FOR REVIEW. ARCHITECT AND ENGINEER'S REVIEW OF SHOP DRAWINGS TO BE FOR CONFORMANCE WITH THE DESIGN CONCEPT AND GENERAL COMPLIANCE WITH THE CONTRACT DOCUMENTS. 4. CONTRACTOR SHALL VERIFY LOCATION OF ALL ROOF OPENINGS. ROOF OPENINGS GREATER THAN 12" DIAMETER SHALL BE FRAMED WITH L3x3x1/4" (MINIMUM). 5. ALL SHOP DRAWINGS SHALL BE PREPARED UNDER THE DIRECT SUPERVISION OF A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF INDIANA. COMPLETE SHOP DRAWINGS FOR CONSTRUCTION SHALL BE SEALED AND SIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF INDIANA AND SHALL BE AVAILABLE AT THE JOB SITE DURING THE TIMES OF INSPECTION. SHOP DRAWING SUBMITTALS SHALL BE SUBMITTED VIA E-MAILED ELECTRONIC FILES THAT ARE IN PDF FORMAT OR CAN BE EASILY CONVERTED INTO PDF FORMAT. PLEASE CONTACT ENGINEER IF SHOP DRAWINGS WILL BE SUBMITTED AS "HARD COPIES." 6. SPECIAL INSPECTION REPORTS AND A FINAL BUILDING REPORT SHALL BE AVAILABLE AT THE TIME THE BUILDING IS APPROVED FOR OCCUPANCY 7. ANY EXISTING STEEL MEMBERS INSTALLED OR EXISTING MEMBERS THAT REQUIRE RETROFIT SHALL BE PAINTED TO MATCH THE EXISTING STEEL MEMBERS. BUILDING CODE REQUIREMENTS AND DESIGNLOADS: ( 1. THE 2014 INDIANA BUILDING 2012 IBC w/ INDIANA STATE AMENDMENTS) 2. DESIGN LOADS CUBICLE POSTS: 200 LBS. APPLIED IN ANY DIRECTION 50 LB./FT. APPLIED IN ANY DIRECTION FROM ATTACHED CUBICLE FRAMING HUNG PARTITION: - 5 P.S.F. (MAX.) ROOF DEAD LOAD - 20 P.S.F. (PER EXISTING DRAWINGS) ROOF LIVE LOAD - 20 P.S.F. (REDUCIBLE) WIND LOAD WIND VELOCITY (ULTIMATE) - 115 MPH EXPOSURE - C RISK CATEGORY - II INTERIOR WIND PRESSURE: - 5 P.S.F. SNOW LOAD GROUND SNOW LOAD - 20 P.S.F. FLAT ROOF SNOW LOAD - 20 P.S.F. (Pm = Pgels) SNOW IMPORTANCE FACTOR - 1.0 yaNT1110 OCCUPANCY CATEGORY CATEGORY II SEISMIC IMPORTANCE FACTOR 1.00 MAPPED SPECTRAL RESPONSE ACCELERATIONS: Ss 0.148 Si 0.082 SITE SOIL CLASS D (ASSUMED) SPECTRAL RESPONSE COEFFICIENTS: SDS 0.157 SDI 0.131 SEISMIC DESIGN CATEGORY B SEISMIC COEFFICIENTS FOR ARCHITECTURAL COMPONENTS INTERIOR NONSTRUCTURAL WALLS AND PARTITIONS op= 1.0 RIP =2.5 SEISMIC COEFFICIENTS FOR MECHANICAL AND ELECTRICAL COMPONENTS OTHER MECHANICAL OR ELECTRICAL COMPONENTS ap BE 1.0 Rip BE 1.5 CONCRETE NOTES: 1. ALL CONCRETE SHALL HAVE A MAXIMUM SLUMP OF 3" TO 5" AND A MINIMUM 28 DAY COMPRESSIVE STRENGTH AS FOLLOWS: SLAB ON GRADE 4000 P.S.I. 2. NO AIR ENTRAINING AGENTS SHALL BE USED IN CONCRETE ON INTERIOR SLABS ON GRADE. (3% MAX. TOTAL AIR) 3. C.J. ON PLANS INDICATES CONSTRUCTION JOINTS OR CONTROL JOINTS. IF NOT SHOWN OTHERWISE; MAINTAIN A MAXIMUM AREA BOUNDED BY THE SLAB CONTROL JOINTS AS FOLLOWS: 6" SLAB 225 SQUARE FEET (i.e. 15' xl5') THE MAXIMUM SIDE RATIO OF WHICH SHALL BE 1.5:1, AND JOINTS AT REENTRANT SLAB CORNERS. 4. ALL STEEL BAR REINFORCEMENT SHALL BE A.S.T.M. A-615, GRADE 60. TIES AND STIRRUPS MAY BE GRADE 40 AT CONTRACTOR'S OPTION. ALL BARS USED IN WELDED CAPACITIES SHALL BE A.S.T.M. A-706. 5. MAINTAIN MINIMUM CONCRETE COVERAGE FOR REINFORCING STEEL AS INDICATED UNLESS OTHERWISE NOTED IN THE DRAWINGS. A. 3" CLEAR WHERE CONCRETE IS DEPOSITED DIRECTLY AGAINST EARTH. B. 2" CLEAR WHERE CONCRETE IS EXPOSED TO EARTH OR WEATHER BUT CAST AGAINST FORMS FOR BARS #6 OR LARGER. C. 11/2" CLEAR WHERE CONCRETE IS EXPOSED TO EARTH OR WEATHER BUT CAST AGAINST FORMS FOR BARS #5 OR SMALLER. D. 3/4" CLEAR FOR SLABS AND WALLS FORMED ABOVE GRADE AND NOT EXPOSED TO WEATHER. E. 11/p" CLEAR FOR BEAMS AND COLUMNS FORMED ABOVE GRADE AND NOT EXPOSED TO WEATHER. 6. WELDED WIRE FABRIC (W.W.F.) SHALL CONFORM TO THE REQUIREMENTS OF THE STANDARD SPECIFICATIONS FOR COLD -DRAWN STEEL WIRE FOR CONCRETE REINFORCEMENT A.S.T.M. A-185. ALL WELDED WIRE FABRIC SHALL BE CLEAN AND FREE OF EXCESSIVE RUST. 7. FLY ASH MAY BE USED AS A DIRECT SUBSTITUTE FOR PORTLAND CEMENT. FLY ASH MUST CONFORM TO ALL ASPECTS OF ASTM C618, STANDARD SPECIFICATION FOR FLY ASH. CLASS F OR CLASS C FLY ASH MAY BE USED, HOWEVER, TOTAL LOSS ON IGNITION OF FLY ASH MUST BE 3% OR LESS. FLY ASH MAY BE SUBSTITUTED ON A 1:1 RATIO BY WEIGHT AND ONLY UP TO A 25% REDUCTION IN THE ORIGINAL CEMENT CONTENT. CONCRETE PROPORTIONS SHALL BE SELECTED ON THE BASIS OF TRIAL MIXES CONFORMING TO A.C.I. 211.1. 8. DESIGN OF CONCRETE STRUCTURAL ELEMENTS IS IN ACCORDANCE WITH ACI 318 9. CONCRETE TEST RESULTS SHALL BE AVAILABLE AT JOB SITE. 10. CONCRETE SUPPLIER TO PROVIDE MIX DATA IN COMPLIANCE WITH ACI 318 it. CONTRACTOR SHALL SUBMIT CONCRETE MIX DESIGNS FOR REVIEW WELL IN ADVANCE OF CONCRETE PLACEMENT. CONCRETE MIX DESIGN SHALL INCLUDE ALL STRENGTH DATA NECESSARY TO SHOW COMPLIANCE WITH THE PROJECT SPECS BY EITHER THE TRIAL BATCH OR FIELD EXPERIENCE METHOD AND SHALL BE CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER. 12. SEE ARCHITECTURAL DRAWINGS/SPECIFICATIONS FOR CONCRETE FLOOR FINISH REQUIREMENTS. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Carmel �VTI�\Dw�1DA.6L DATE: 10/14/19 1. ALL STRUCTURAL STEEL SHALL BE PROVIDED AS FOLLOWS: RECTANGULAR/SQUARE HSS SHAPES (ASTM A500 Dr. B) 46 K.S.I. YIELD ROUND HISS SHAPES (ASTM A500 Dr. B) 42 K.S.I. YIELD STEEL PIPES (ASTM A53 Gr. B) 35 K.S.I. YIELD W SHAPES (ASTM A992) 50 K.S.I. YIELD STRUCTURAL STEEL U.N.O. (ASTM A36) 36 K.S.I. YIELD 2. ALL STRUCTURAL STEEL FASTENERS SHALL BE PROVIDED AS FOLLOWS: BOLTED CONNECTIONS IN STEEL FRAMEWORK U.N.O. (ASTM A325-N) CARBON AND ALLOY NUTS (ASTM A563) HARDENED STEEL WASHERS (ASTM F-436) COMPRESSABLE-WASHER-TYPE DIRECT TENSION INDICATORS (ASTM F-959) THREADED RODS (ASTM A36) ANCHOR RODS U.N.O. (ASTM F1554 Gr. 36) 3. UNLESS NOTED OTHERWISE IN THE DRAWINGS, ALL FILLET WELDS SHALL BE 3/16 ALL WELDS SHALL BE MADE WITH E-70 ELECTRODES. MIN. LENGTH OF INTERMITTENT WELDS SHALL BE 11/p" 4. PROOF OF WELDER CERTIFICATION SHALL BE AVAILABLE AT THE JOB SITE DURING TIMES OF INSPECTION. 5. GRIND EXPOSED WELDS SMOOTH AND FLUSH, TO MATCH AND BLEND WITH ADJOINING SURFACES WHERE DEEMED NECESSARY FOR AESTHETIC PURPOSE BY ARCHITECT. 6. OBTAIN ALL FIELD MEASUREMENTS REQUIRED FOR PROPER FABRICATION AND INSTALLATION PRIOR TO DETAILING. PRECISE MEASUREMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR. 7. THE FABRICATOR SHALL BE RESPONSIBLE FOR ALL ERRORS OF DETAILING ON THE SHOP DRAWINGS, ERRORS IN FABRICATION, AND CORRECT FTTTING OF STRUCTURAL STEEL MEMBERS. 8. NO LOADS ARE ALLOWED TO BE HUNG FROM ROOF DECK. 9. BOLTED CONNECTIONS SHALL BE ASSEMBLED AND INSPECTED ACCORDING TO "SPECIFICATIONS FOR STRUCTURAL JOINTING USING ASTM A325 OR ASTM A490 BOLTS." WELDED CONNECTIONS SHALL CONFORM TO THE PROVISIONS OF AWS D1.1, STRUCTURAL WELDING CODE BY AMERICAN WELDING SOCIETY (SECTION 2207). 10. FOR COLD -FORMED METAL FRAMING (STRUCTURAL): MEMBERS SHALL POSSESS MIN. SECTION AND MATERIAL PROPERTIES PER AISI COLD -FORM STEEL SPECIFICATIONS AND THE STEEL STUD MANUFACTURERS ASSOCIATION. MATERIALS AND ERECTION SHALL BE PER MANUFACTURER'S SPECIFICATIONS. ALL SIZES SHOWN ON CD'S ARE MINIMUM SIZES AND SHOULD BE DESIGNED PER SPECIFICATION SECTION 05400 AND LOADING ON THIS SHEET 11. GROUT SHALL BE NON -SHRINK WITH A MINIMUM 7 DAY COMPRESSIVE STRENGTH OF 3000 P.S.I. EXPOSED GROUT SHALL BE NON -STAINING. COLD -FORMED LIGHT GAUGE METAL STUD FRAMING NOTES: 1. SEE ARCH. DRAWINGS FOR ALL PARTITION LOCATIONS AND HEIGHTS. 2. METAL STUDS SHALL BE LATERALLY BRACED AT 48" O.C. MAX. 3. WHERE COLD FORMED METAL FRAMING IS FIELD WELDED, ALL WELDS AND SURROUNDING AREAS SHALL BE FIELD PAINTED w/ A ZINC RICH PAINT. 4. PROVIDE BUILT UP SECTIONS WHERE REQUIRED AT OPENING JAMB, HEADS AND SILLS. LAP SPLICE SCHEDULE BAR SIZE LAP SPLICE DIMENSION (IN) Vc = 4000 psi OTHER TOP BARS #3 19" 25" #4 25" 32" #5 31" 40" #6 38" 49" #7 55" 71" #8 63" Bill #9 70" 91" r v T/FTG L- HOOKED BAR SCHEDULE BAR SIZE X Idh Y #3 0'-6" 0'-6" LAP SPLICE #4 0'-8" 0'-8" LAP SPLICE #5 0'-10" 0'-10" LAP SPLICE #6 1'-0" 1'-0" LAP SPLICE #7j V-2" V-2" LAP SPLICE #8 V-4" V-4" LAP SPLICE METAL ROOF DECK. PROVIDE (2) #10-16 SCREWS SEE PLAN. AT 48" O.C. MAX. PROVIDE (2)-0.15710 HILTI X-U FASTENERS (OR EQUIV.) METAL ROOF DECK. AT EACH JOIST. SEE PLAN. L 3 N N I .�I T < a c� - SEE PLAN SEE PLAN N FOR JOIST. FOR JOIST. N PERPENDICULAR TO JOISTS 20GA DEEP LEG SLIP TRACK. O LNO ATTACHMENT OF TRACK TO TRACK. 20GA DEEP LEG O CAPPING TRACK. (1)-#10-16 SCREW AT EACH FLANGE. SLAB ON GRADE. E PLANS. INTERIOR METAL) STUDS. SEE ARCH. PARALLEL TO JOISTS INTERIOR MI STUD WALL. SEE ARCH. MIN. 18 GA RUNNER TRACK SOLID BLOCKING AT 10'-0" O.C. MAX. VERTICAL (U.N.O.) SEE PLAN MAKE RUNNER TRACK 8" LONGER FOR JOIST. THAN STUD INSIDE SPACING. CUP FLANGES OF TRACK 4" FROM EACH END. BEND TRACK AT CLIPPED FLANGES. BLOCKING AT 5'-4" O.C. MAX. HORIZONTAL (EVERY 4TH STUD SPACING) 1-1/4" x 20 GA. STRAPPING, SCREW TO EACH STUD FLANGE 10SCREW. (STRAPPINGNG TOTO START ART & END ON SOLID BLOCKING) MTL STUDS. SCREW ATTACH BOTH PARTS OF CUT FLANGE TO STUD ON EACH SIDE WITH (2)#10-16 SCREWS. USE (6) #10-16 SCREWS ON EACH SIDE OF BLOCKING. WEAK AXIS STUD BRACING USE 18GA RUNNERS ALONG BOT/STUD WALLS. NO SCALE NOTE: INSIDE DIMENSION OF OUTER TRACK AT CONCRETE BASE SHOOT RUNNER TO CONCRETE TO BE �" MORE THAN STUD DEPTH. USING (2)-0.157"0 HILTI X-U FASTENERS AT 16" O.C. SEE ARCHITECTURAL DRAWINGS FOR PLAN AND LOCATIONS OF DETAILS ON THIS SHEET, TYP. O END/WALL 362S137-33 VERT. METAL STUDS AT 16" O.C. MAX. SCREW FLANGES CONT. 3621125-43 TOP AND BOT. AT STEEL BASE SHOOT RUNNER TO STEEL USING (2)-0.157"0 HILTI X-U FASTENERS EVERY 16" O.C. SCREW VERT. STUDS TO RUNNER USING (2) #10-16 SCREWS TYPICAL INTERIOR METAL STUD WALL DETAILS FYNAIM2111F•: HSS32x3zx} CUBICLE END POST. ATTACH TO SLAB AS SHOWN, SEE ARCH. FOR ADD'L CUBICLE INFO. J" THICK x 31" WIDE x 8" LONG BASE R. ATTACH TO SLAB USING (4)-x¢" DIA. SIMPSON STRONG -TIE TITEN-HD ANCHORS EMBEDED 2j" INTO SLAB OR EQUIVALENT. G.C. NOTE: - MAXIMUM POST SPACING SHALL BE 5'-0" O.C. - IN ADDITION TO SPACED POSTS, PROVIDE POSTS AT CUBICLE ENDS 1 CUBICLE POST ATTACHMENT 1 "0 SCALE: N.T.S. EXISTING SLAB GRADE 1. POST -INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLING POST -INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST -IN -PLACE ANCHORS. THE PRODUCTS SHOWN ON CONSTRUCTION DOCUMENTS ARE THE DESIGN BASIS FOR THIS PROJECT. PRODUCT DIAMETER AND EMBEDMENT SHALL BE AS SHOWN IN THE DETAILS. INSTALL PRODUCTS IN ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS (MPII). CONTRACTOR SHALL CONTACT MANUFACTURER'S REPRESENTATIVE FOR PRODUCT INSTALLATION TRAINING AND A LETTER SHALL BE SUBMITTED TO THE ENGINEER -OF -RECORD (EOR) INDICATING TRAINING HAS TAKEN PLACE. REFER TO THE PROJECT BUILDING CODE AND/OR EVALUATION REPORT FOR SPECIAL INSPECTIONS AND PROOF LOAD REQUIREMENTS. SUBSTITUTION REQUESTS FOR PRODUCTS OTHER THAN THOSE SHOWN MAY BE SUBMITTED BY THE CONTRACTOR TO THE ENGINEER -OF -RECORD (EOR) FOR REVIEW. SUBSTITUTIONS WILL ONLY BE CONSIDERED FOR PRODUCTS HAVING A CODE REPORT RECOGNIZING THE PRODUCT FOR THE APPROPRIATE APPLICATION UNDER THE PROJECT BUILDING CODE. SUBSTITUTION REQUESTS SHALL INCLUDE CALCULATIONS THAT DEMONSTRATE THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE EQUIVALENT PERFORMANCE VALUES OF THE DESIGN BASIS PRODUCT. NEW SLAB TO MATCH EXISTING SLAB AFTER NEW UTILITIES HAVE BEEN INSTALLED. USE CONCRETE W/ MIN. 4000 PSI 28 DAY COMPRESSIVE STRENGTH. #57 STONE GRAVEL SUBBASE AROUND NEW UTILITY. - PROVIDE 15 MIL. STEGO WRAP PLACED OVER MINIMUM 6" GRAVEL SUBASE UNDER ALL NEW SLAB AREAS THAT WERE PREVIOUSLY DEMO'D. TRENCHED IN UTILITY LESS THAN V-0" WIDE SCALE: N.T.S. #4 BARS CONT. PER SCHEDULE AT MID DEPTH OF SLAB. MIN. LAP LENGTH = 2'-1" EXISTING SLAB ON--\ GRADE df" DIA. x 12" LONG SMOOTH - BAR DOWELS AT 12" O.C. EMBED 6" INTO EXISTING SLAB USING SIMPSON SET-XP EPDXY ADHESIVE. GREASE END OF DOWEL AT NEW SLAB. WIDTH NO. #4 BARS 24" 2 24<W536" 3 36<WS54" 4 54<W<72" 5 SAWCUT SLAB TO MATCH EXISTING JOINT SPACING `M vi = "w" NEW SLAB TO MATCH EXISTING SLAB AFTER NEW UTILITIES HAVE BEEN INSTALLED. USE CONCRETE W/ MIN. 4000 PSI 28 DAY COMPRESSIVE STRENGTH. #57 STONE GRAVEL SUBBASE AROUND EXISTING UTILITY FULLY COMPACTED. G.C. NOTES: - TYPICAL REBAR MAY NOT BE USED TO SUBSTITUTE THE PLAIN SMOOTH BAR DOWELS SHOWN. THE PURPOSE OF THE PLAIN SMOOTH BAR DOWELS IS TO ALLOW THE CONCRETE TO SHRINK DURING CURING WITHOUT THE CONCRETE BONDING TO THE SMOOTH BARS. PROVIDE 15 MIL. STEGO WRAP PLACED OVER MINIMUM 6" GRAVEL SUBASE UNDER ALL NEW SLAB AREAS THAT WERE PREVIOUSLY DEMO'D. TRENCHED IN UTILITY GREATER THAN 1'-0'e WIDE SCALE: N.T.S. 1 }" x 1 }", 16 GA. CLIP ANGLE FASTENED W/ (4) #10-16 SCREW SHOWN. ANGLE LENGTH SHALL NOT LESS THAN STUD DEPTH, MINUS 16 GA. U-CHANNEL '.IDGING SPACED AT 48" O.C. STUD, SIZE AND REQUIRED BRIDGING DETAIL - STUD WALL LATERAL BRACING SCALE: N.T.S. HANEs GIPSON & Assoc1ATES CIVIL " STRUCTURAL CONSULTING ENGINEERS 1550 NORTH BROWN ROAD SUITE 100 LAWRENCEVILLE. GEORGIA 30043 PHONE: (770) 491-7550 FAX (770) 491-7750 NOTE; These drawings are NOT TO BE REPRODUCED for the purpose of generating shop drawings without the WRITTEN APPROVAL of the STRUCTURAL ENGINEER. ASSOCIATES AND IS NOT TO BE REPRODUCED IN WHOLE OF IN PART IT IS NOT TU BE USED ON Ary IT"' RIGHT AS DATED HAINES. GIPSON I ASSOCIATED NOT VALID OILESS SERED MID SEALED. RELEASED FOR CONSTRUCTION W Z a CYJ LL 0 0 LV 6L! 1. >111 O 2 > Z OLL ZT0 W �3� LU n $ J 0 r%C1 Is I-u OZ0 7 LU Z Z a =°D Ir a 4 W EE F FE r Z I- Z 1!J M1.9 Z 20-19033 z:ee 12 JULY 2019 STRUCTURAL NOTES AND DETAILS S 1 111