L100 LIFE SAFETY
CODE SUMMARY 1 SCOPE OF WORK OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE 2 PREVIOUS USE OF SPACE B(USINESS) 3 OCCUPANCY CLASSIFICATION B(USINESS) 4 CHANGE OF OCCUPANCY CLASS? NO 5 TOTAL BUILDING AREA 35,178 SF/FLOOR X 1 3STORIES = 105,534 SF 6 TOTAL PROJECT AREA 1,090 SF 7 OCCUPANCYCALCULATIONS SPACETYPE AREA SFPER OCCUPANT OCCUPLOAD 6 NUMBER OF EXITS 9 SPRINKLER SYSTEM (YES/NO) 10 TOTAL AREA OF ACCESSORY USES 11 TOTAL AREA ON THE FLOOR 12 ACCESSORY AREA EXCEEDS 10% 13 FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) 14 ASHRAE 90.1 SUMMARY 15 BUILT B EFORE 1978? 16 BUILDING CONSTRUCTION TYPE LEGEND TOTAL OCCUPANTS IN PROJECT AREA REQUIRED:I PROVIDED:2 YES - EXISTING TO REMAIN 0 SF 35,178 SF NO N/A EXEMPT (SEE REFLECTED CEILING NO II-B EP EXISTING ELECTRICAL PANEL LOCATION EX EXISTING EXIT. BUILDING STAIR LOCATION fE FIRE EXTINGUISHER ® EXITSIGN-LED EDGE LIT EMERGENCY LIGHT - - - TRAVEL DISTANCE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Carmel (� �VT�SJ'�D*tiYWML DATE: \ 10/14/19 r AREA NOTIN CONTRACT AREA OF WORK OFFICE OFFICE ml \I�I lasx14In I©-IP OP ®FICE n InI I I I I _I -----------� TRAVEL DISTANCE = 138' OFFICE LIFE SAFETY NOTES I. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBESI, EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEI R EXPENSE. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES. 4. FIRE PROTECTION WORK 5 TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING —1 JURISDICTION OVER THE PROJECT. IS TRAVEL DISTANCE = 165' I GENERAL NOTES LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. L2. EXISTING EXITSIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET ALL LOCAL AND STATE CODES. LIFE SAFETY PLAN 0 4' 8' 16' THIS DRAWING. AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. 0 0 WN W N N Zoe 0 J �0 m OJZ Q Z J O '-'-I ZU) Inv WQ O=U IV z O � 0 LO ISSUE DATE DESCRIPTION 08.28.19 REVIEW SET 09.03.19 PERMITSET REVISIONS MARK DATE DEIOESCRIP110N IN 0. AR10700017 STATE OF PROJECT NUMBER 2019.330 PROJ.MGR DRAWN BY I BW CRB 2ND FLOOR LIFE SAFETY IN L 100