HomeMy WebLinkAboutT111 COVER SHEET & GENERAL NOTESGENERAL PROJECT NOTES MECHANICAL 8& ELECTRI ].BUILDING CODE COMPLIANCE: ALL WORKS HALL COMPLY WITH THE REQUIREMENTS OF THE EXISTING BUILDING CONSTRUCTION TYPE AS DEFIN ED BY SECTION 601 OF THE INDIANA BUILDING CODE. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL BUILDING CODES. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE CURRENT APPLICABLE BUILDING CODES) FOR THEIR RESPECTIVE SCOPE OF WORK. ENSURE THAT ALL MATERIALS AN D LABOR ARE IN ACCORDANCE WITH THE BEST QUALITY STANDARDS OF EACH RESPECTIVE TRADE WHETHER SPECIFIED OR NOT. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK IS IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL BUILDING CODES, AND STANDARDS FOR GENERAL, MECHANICAL, AND ELECTRICAL CONSTRUCTION. 2. CONTRACTOR SITE VISITS: CONTRACTORS) SHALL VISIT THE WORK SITE PRIOR TO COMMENCEMENT, THE DRAWINGS CONTAINED HEREIN MAY NOT BE ALL INCLUSIVE OF EXISTING CONDITIONS OR NEW WORK REQUIREMENTS. CONTRACTORS) SHALL MAKE THEMSELVES FAMILIAR WITH THE WORK SITE IN THE FIELD IN ORDER TO BE FULLY AWARE OF THE REQUIREMENTS OF THE SCOPE OF WORK. 3. CONTRACTOR FIELD VERIFICATION: FIELD VERIFY ALL DIMENSIONS AND MEASUREMENTS. INFORM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY CONSTRUCTION IF EXISTING CONDITIONS PREVENT OBTAINING RESULTS AS SHOWN OR SPECIFIED. DO NOT SCALE DRAWINGS, NOTED DIMENSIONS TAKE PRECEDENCE, VERIFY EXISTING CONDITIONS INDICATED ON THE DRAWINGS AND REPORT ANY DISCREPANCY THROUGH THE GEN ERAL CONTRACTOR TO SCHOTT DESIGN, INC. 4. GENERAL CONTRACTOR COORDINATION WITH OWNER: THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING ALL ON -SITE ACTIVITIES; SUCH A5, BUT NOT LIMITED TO, WORK SCHEDULE, MATERIALS STORAGE AND HANDLING, DELIVERIES, ACCESS TO THE WORK SITE, TRAFFIC CONTROL, AND BUILDING/PUBLIC SAFETY PROCEDURES DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO COORDINATE WORK BY OTHERS" WITH HIS/HER OWN ACTIVITIES AS NECESSARY TO EXECUTE THE OVERALL PROJECT SCOPE. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, DAILY WORKING HOURS, WEEKEND HOURS AND HOURS THAT MAY BE WORKED PRIOR TO AND DURI NO HOLIDAYS. LANDLORD RESERVES THE RIGHT TO RESTRICT CONSTRUCTION TO NIGHTS AND WEEKENDS WHEN THAT CONSTRUCTION 15 DEEMED TO INTERFERE WITH THE OPERATIONS OF ADJACENT TENANTS. 5. PROJECT MATERIAL LEAD TIMES: FOR THOSE ITEMS TO BE ORDERED REQUIRING LEAD TIME, THE CONTRACTOR SHALL COORDINATE THE PROJECT SCHEDULE ACCORDINGLY AND COMMUNICATE TO THE OWNER, TENANT, AND SCHOTT DESIGN WHEN DECISIONS MUST BE RENDERED IN ORDER FOR THE CONTRACTOR TO MEET THE PROJECT SCHEDULE, THE OWNER, TENANT, OR DESIGNER/ARCHITECT IS NOT RESPONSIBLE FOR DELAYS RESULTING FROM THE CONTRACTOR'S FAILURE TO COMMUNICATE MATERIAL LEAD TIMES. 6. MATERIAL SUBSTITUTIONS: SUBSTITUTIONS FOR SPECIFICALLY NAMED PRODUCTS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL FROM THE DESIGNER. SUBMIT REQUESTS FOR SUBSTITUTIONS WITH APPROPRIATE SUPPORT INFORMATION TO THE DESIGNER. ALLOW REASONABLY SUFFICIENT TIME FOR THE DESIGNER TO REVIEW THE REQUEST AND RENDER A DECISION. 7. SAFE WORK AREA: SCHOTT DESIGN, INC., SHALL NOT HAVE CONTROL OVER, OR BE IN CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR A CONTRACTOR'S CONSTRUCTION MEANS, METHODS, SCHEDULES, SEQUENCES, OR SAFETY. THE CONTRACTORS SHALL BE RESPONSIBLE FOR MAINTAINING A SAFE ENVIRONMENT FOR WORKERS AN D THE PUBLIC AT ALL TIMES. B. GENERAL CONTRACTOR CLEANUP PROCEDURES: THE GENERAL CONTRACTOR SHALL ESTABLISH WITH THE LANDLORD CLEANUP PROCEDURES AND GUIDELINES TO BE FOLLOWED ON A DAILY BASIS IN ORDER TO CONDUCT BUSINESS IN ASAFE AND CLEAN ENVIRONMENT. 9. STAGING/ PARKING/ DUMPSTERS/ RESTROOMS: THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE LANDLORD, AN AREA FOR STAGING OF CONSTRUCTION MATERIALS, EQUIPMENT, DUMPSTER AND PARKING CONSTRUCTION AND DELIVERY VEHICLES. THE USE OF EXISTING REST ROOM FACILITIES SHALL BE APPROVED BY THE LANDLORD. ONLY THOSE DESIGNATED AREAS SHALL BE USED BY CONSTRUCTION CREWS. 10. DUST CONTROL: THE GENERAL CONTRACTOR SHALL USE DUST PARTITIONS TO MINIMIZE DISTURBANCES OF DAILY TENANT OPERATIONS DURING DEMOLITION AND CONSTRUCTION WORK. DUST PARTITIONS SHALL BE CONSTRUCTED OF 2X4 WOOD STUDS ® 24"O.C., INSULATION AND 6 MIL VAPOR BARRIER ON EACH SIDE, 11. PROJECT INSTALLATION CONFLICTS: CONTACTTHE DESIGNER IMMEDIATELY IF, IN THE FIELD, CONFLICTS ARE DISCOVERED BETWEEN COMPONENTS OF DIFFERENT SYSTEMS THAT PREVENT THE INSTALLATION OF THOSE COMPONENTS AS INDICATED ON THE DRAWINGS. (I.E. WHERE EXISTING MECHANICAL DUCTWORK MAY PREVENT THE NSTALLATION OF LIGHTING FIXTURES AS INDICATED ON THE CEILING PLAN). 12. SCHOTT DESIGN HAZARDOUS MATERIALS WAIVER: SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE IDENTIFICATION, DISCOVERY, PRESENCE, HANDLING, REMOVAL, DISPOSAL OF, OR EXPOSURE TO ANY PERSONS, THAT OF HAZARDOUS MATERIALS IN ANY FORM ON THE PROJECT SITE. 13. WOOD BLOCKING IN WALLS: PROVIDE FIRE -TREATED WOOD BLOCKING IN WALLS FOR ALL WALL HUNG ITEMS INCLUDING MILLWORK, WALL STOPS, CABINETRY. ETC, 14. SHOP DRAWINGS: SHOP DRAWINGS OR CATALOG CUTS MUST BE SUBMITTED TO SCHOTT DESIGN, INC. FOR APPROVAL ON ALL MATERIALS OR ITEMS WHERE THE CONTRACTOR CHOOSES TO DEVIATE FROM WHAT IS SHOWN ON THE DRAWINGS, OR IF THE DRAWINGS DO NOT INDICATE A SPECIFIC MANUFACTURER OR MODEL NUMBER. EXPEDITE PREPARATION AND SUBMITTAL OF ALL SHOP DRAWINGS TO ALLOW SUFFICIENT TIME FOR CHECKING, APPROVAL, ORDERING, FABRICATION, AND DELIVERY OF MATERIALS AND EQUIPMENT. 15. PROJECT APPROVALS: ALL DETAILS, MATERIALS, AND INSTALLATIONS ARE SUBJECT TO FIRST APPROVAL BY SCHOTT DESIGN, INC., AND FINAL APPROVAL BY THE OWNER. 16. CHANGE ORDERS: REVIEW AND COORDINATE ALL NEW WORK AND EXISTING CONDITIONS WITH ALL OTHER TRADES, FIELD WORK ORDERS & CHANGE ORDERS WILL NOT BE APPROVED FOR ANY CONDITIONS OR CONFLICTS THAT COULD HAVE BEEN ACCOUNTED FOR BY THE BIDDER DURING PRE -BID FIELD INSPECTION AND AFTER AWARD OF CONTRACT, RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Carmel (� �VT�U'�D*tiYWML DATE: \ 10/14/19 17. FURNITURE AND EQUIPMENT EXCLUSIONS: FURNITURE, OFFICE EQUIPMENT OFFICE PARTITION SYSTEMS, REFRIGERATORS, VENDING MACHINES, AND OTHER SIMILAR ITEMS SHOWN DASHED ON THIS DRAWING AND NOT ATTACHED TO THE BUILDING ARE FOR REFERENCE ON LV AND ARE NOT TO BE PROVIDED AS PART OF THE WORK UNLESS SPECIFICALLY STATED TO BE PROVIDED, 18. WALL PATCHING: PATCH ALL GYPSUM WALLBOARD AT AREAS OF ELECTRICAL, DATA AND SWITCH DEVICES BEING REMOVED. PATCH HOLE WITH DRYWALL, TAPE, SPACKLE AND PREPARE FOR FINISH. 19. CONSTRUCTION CLEANING: EXECUTE A THOROUGH FINAL CLEAN AND NSPECTION OF THE SPACE UPON COMPLETION OF THE PROJECT. ALL SURFACES FIXTURES AND EQUIPMENT SHALL BE CLEAN AND THE SPACE SHALL BE TURNED OVER TO THE OWNER IN A CONDITION THAT REPRESENTS THE HIGHEST LEVEL OF CARE AND PROFESSIONALISM. ENSURE ALL GENERAL CONTRACTOR INSTALLED APPLIANCES WORK & DO NOT LEAK. 20, O&MMATERIALS: PROVIDE TO THE OWNER ALL OPERATION AND/OR MAINTENANCE MANUALS, OR INSTRUCTIONS FOR ALL EQUIPMENT AND SYSTEMS AT THE COMPLETION OF THE PROJECT. 21. PLAN DIMENSIONS: ALL PLAN DIMENSIONS ARE FROM FACE OF EXISTING FINISH TO FACE OF NEW GYPSUM BOARD WALL, OR FACE TO FACE OF NEW GYPSUM BOARD WALL. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. 22. WINDOW BLINDS: CONTRACTOR TO PROVIDE AN ALLOWANCE FOR CLEANING EXISTING WINDOW BLINDS. REPLACE ANY DAMAGED OR MISSING WINDOW BLINDS WITH NEW TO MATCH BUILDING STANDARD. 23, PERMITTING: THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE REQUIREMENTS REGARDING LOCAL PLAN REVIEW, PERMITS, NSPECTIONS, AND FEES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL REQUIRED DRAWINGS AND SUPPORTING DOCUMENTS TO THE LOCAL BUILDING OFFICIAL AND/OR PERMIT DEPARTMENT. ALL REQUIRED LOCAL PERMIT FEES SHALL BE PAID BY THE GENERAL CONTRACTOR UNLESS STIPULATED OTHERWISE IN THE OWNER/CONTRACTOR AGREEMENT. 24, FIRE SEALING: FIRE SEAL ALL PENETRATIONS THROUGH RATED WALLS, FLOORS, AND CEILINGS WITH APPROVED FIRE -RATED CAULK AS DIRECTED BY LOCAL JURISDICTIONS. CONTRACTOR TO BE AWARE THAT EXISTING CONDITIONS ARE NOT NECESSARILY AN INDICATOR OF BUILDING TYPE, BUILDING TYPE LISTED ON LI00 IS BASED UPON AVAILABLE INFORMATION AND FIELD VERIFICATION. 25. WALL PENETRATIONS: WHERE STRUCTURAL BEAMS DUCTWORK, ETC. PENETRATE SOUND OR FIRE RATED PARTITIONS, GYPSUM WALLBOARD WALL TO BE SCRIBED TO FIT TIGHT, CAULKED AND FIRE DAMPERED IF REQUIRED. 26. FLOOR LEVELING: CONTRACTOR TO ALLOW FOR UNLEVEL FLOOR CONDITIONS. ALL EXISTING FLOOR AND WALL SUBSTRATES SHALL BE LEVELED AND PATCHED AS REQUIRED TO RECEIVE NEW CONSTRUCTION AND FINISHES. ADJUST DOORS AND FRAMES AS REQUIRED. 27, REPAIR GYPSUM WALLBOARD: WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS, 28. EQUIPMENT INSTALLATION: ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS. FINISH NOTES 1. STATE BUILDING COMPLIANCE FOR FINISHES: ALL FINISHES SHALL COMPLY WITH CHAPTER (INTERIOR FINISHES) OF THE INDIANA BUILDING CODE FOR CLASS A FIRE RATINGS. 2. GYPSUM ASSOCIATION CONFORMITY: FOR ALL NEW DRYWALL INSTALLATIONS, INSTALL AS RECOMMENDED BY THE GYPSUM ASSOCIATION. (SUCH AS, CONTROL JOINTS, FINISH LEVELS, FASTENERS, TAPING DETAILS, CORNER BEADS, ETC.) PROVIDE NEW CEMENT BACKER BOARD AS A SUBSTRATE FOR NEW WALL TILE PER MANUFACTURER'S RECOMMENDATIONS. 3. COVER PLATES: REFERENCE REFLECTED CEILING PLAN AND ELECTRICAL PLAN FOR COLOR OF ELECTRICAL AND DATA DEVICES AND PLATES. REMOVE ALL PLATES BEFORE PAINTING AND REATTACHED AFTERWARDS. CONTRACTOR TO CONFIRM DESIRED COLOR PRIOR TO PURCHASING NEW. 4. PAINTING: ALL AREAS RECEIVING PAINT ARE TO RECEIVE PRIMER COAT AN D TWO (2) FINISH COATS. 5. FLOORING TRANSITION STRIPS: FOR CHANGE IN FLOOR FINISH MATERIAL, PROVIDE TRANSITION STRIP AT DOOR OPENINGS AS NOTED ON FINISH PLAN UNLESS NOTED OTHERWISE (I.E. WHERE VCT MEETS CARPET). 6. DELIVERY OF COMPREHENSIVE WORK PRODUCT: WHERE LIMITS OF WORK ARE SHOWN, OTHER INCIDENTAL WORK LIKE PAINTING WHERE NEW OUTLETS HAVE BEEN INSTALLED, IS CONSIDERED PART OF THE SCOPE OF WORK. PROVIDE A COMPLETE AND FINISHED PRODUCT READY FOR TENANT AND BUILDING OWNER. 7. WALL DEMOLITION: REFINISH SURFACES TO MATCH EXISTING WHERE DEMOLITION HAS OCCURRED. REPAIR GYPSUM WALLBOARD WHERE DEMOLITION HAS OCCURRED AT REMAINING WALLS. REPAIR ANY GYPSUM BOARD DAMAGED BY DEMOLITION. PROVIDE EXPANSION JOINTS IN DRYWALL WHERE NEW WALLS MEET OR ADJOIN TO EXISTING CORE WALLS. 8. TELEPHONE BOARDS: WHERE PHONE BOARD IS PROVIDED, PAINT BOARD WITH FIRE RETARDANT PAINT TO MATCH ADJACENT WALL FINISH. 9. MILLWORK SAMPLES: SUBMIT FINISH SAMPLE OF MILLWORK (STAINED OR PAINTED AS SPECIFIED) TO SCHOTT DESIGN FOR REVIEW AND APPROVAL PRIOR TO THE FINISHING PROCESS OF ALL MILLWORK. 10. INTERIOR ELEVATION DETAILS: REFERENCE INTERIOR ELEVATION & SECTIONS WHERE PROVIDED FOR ADDITIONAL FINISH INFORMATION. 11. PAINT & ADHESIVE VOC'S: ALL PAINTS AND ADHESIVES/SEALANTS SHALL HAVE ZERO VOC CONTENT, 12. ADHESIVE MANUFACTURER RECOMMENDATIONS: ALL ADHESIVES/SEALANTS TO BE USED AS RECOMMENDED BY PRODUCT MANUFACTURER. I. DEIGN/BUILD MEP: THE MECHANICAL, ELECTRICAL AND PILL SCOPES OF WORK ARE LIMITED TO BASIC DESIGN -BUILD ALTERA WHICH ARE OUTLINED IN THESE PLANS. THE DESIGN -BUILD CON FOR EACH TRADE MUST NOTI FV THE ARCHITECT IF THEY FI ND THP SCOPE OF WORK EXCEEDS THE LEVEL OF MECHANICAL, ELECTF PLUMBING WORK INDICATED ON THESE DRAWINGS SO THAT AP NECESSARY ENGINEERING CAN OCCUR AND ADDITIONAL PLAI FILED, OR IF ADDITIONAL INFORMATION IS NEEDED IN ORDER iC WORK IN THE FIELD. THE MECHANICAL, ELECTRICAL AND PLUM DESIGN -BUILD CONTRACTORS SHALL COMPLY WITH ALL APPLIC STATE AND LOCAL BUILDING CODES. FIRE SUPPRESSION AND FIRE ALARM SYSTEMS SHALL BE INSTALLE APPROPRIATE DESIGN -BUILD CONTRACTOR AND MUST COMPL' APPLICABLE STATE AND LOCAL BUILDING CODES. FIRE SUPPREI AND FIRE ALARM DESIGN -BUILD CONTRACTORS ARE RESPONSU COMPLETING AND FILING THEIR PLANS AND OBTAINING THEIR F 2. DESIGN/BUILD HVAC: MECHANICAL WORK IS LIMITED TO DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. NI MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEI PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATIO DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. NO NEW H. DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAI REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUS Y WITH THE INDIANA MECHANICAL CODE AND ALL OTHER APPLI( CODES, 3. HVAC HEAT LOADS: VERIFY HEAT LOADS OF ANY SPECIAL EG 'MENT N THE TENANT SPACE, AND PROVIDE ADDITIONAL AIR FLOW IF WRED CONFIRM WITH OWNER PRIOR TO ANY PURCHASE OF NEW EQL RENT. REVISE ZONING IF REQUIRED. DO NOT DESIGN ANY SINGLE OFF SPACE TO BE ON A SPLIT ZONE UNLESS APPROVED BY BUILDING OWNER/LANDLORD. CONTRACTOR TO ENSURE THAT ALL HVAC )NES ARE LOCATED APPROPRIATELY SUCH THAT NO SPLIT ZONES ARE OFFICES OR CONFERENCE ROOMS. 4. HVAC DIFFUSER LOCATIONS: RELOCATE AIRSUPPLYDIFFUSEF ND RETURN -AIR GRILLES AS REQUIRED, PROVIDE PROPER AIR SUPPL DIFFUSERS AND RETURN AIR FROM RETURN AIR GRILLES. CONTR TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES A REQUIRED DE. QU BY CO 5. HVAC THERMOSTAT LOCATIONS: POSITION LOCATION OF ALIF THERMOSTATS WHERE APPROPRIATE PER MECHANICAL DESIGN COORDINATE WITH TENANT AND BUILDING OWNER FOR FURNIT o PANEL OR OTHER CONFLICTS. 6. DESIGN/BUILD ELECTRICAL: ELECTRICAL WORK IS LIMITED TO DESIGN -BUILD SCOPE AND 15 OUTLINED IN THESE DRAWINGS. AI ELECTRICAL WORK 15 LIMITED TO ADDITIONS OR RELOCATIONS ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXC ) THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDIN ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS C I BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 7. ELECTRICAL CODE COMPLIANCE: COMPLY WITH THE INDIAN. ELECTRICAL AND MECHANICAL CODE AND ALL OTHER APPLIC. .E CODES. I''''''""" 8. ELECTRICAL CIRCUITING: SIZE AND CIRCUIT ELECTRICAL POW PROVIDE OR REUSE ELECTRICAL POWER AND DATA OUTLETS AS REQUIRED. 9. GFI OUTLETS: ALL ELECTRICAL OUTLETS WITHIN 60 OF WATER !E TO BE G.F.C.I. 10. PHONE AND DATA ACCOMMODATIONS: AT EACH PHONE A DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO BOX.TI \NTS DATA CONTRACTOR 15 RESPONSIBLE FOR PULLING CONDUCTO AND PROVIDING APPROPRIATE TERMINALS AT FACE PLATE. 11. ELECTRICAL SWITCH PLATES: PROVIDE COLORED FACEPLATI :OR ELECTRICAL OUTLETS &SWITCH PLATES TO MATCH EXISTING, UP SS OTHERWISE NOTED. ELECTRICIAN TO FIELD VERIFY PRIOR TOPU HASE. 12. WORKSTATION POWER: PROVIDE JUNCTION BOXES OR PO\ 2 POLES AT WORKSTATIONS WHERE SHOWN. REFER TO THE PLAN FOR TH APPROPRIATE DESIGNATIONS. DATA WILL BE RUN BY THE TENAP VENDOR. ELECTRICIAN TO MAKE FINAL CONNECTION FROM WORKSTATION WHIP TO JUNCTION BOX. THE FURNITURE VENDOR IS TO BE RESPONSIBLE FOR WIRING THE BASE PANELS OF THE WORKSTATIONS. CONTRACTOR TO COORDINATE WITH TENANT ON WORKSTATION FURNITURE SPECIFICATIONS TO OBTAIN CIRCUITRY REQUIREMENTS PRIOR TO RUNNING ELECTRICAL CONDUITS TO JUNCTION BOXES. 13. LIGHTING CIRCUITS: VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW CIRCUITS AS REQUIRED. PROVIDE NEW OR REVISE EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT FIXTURES. 14. ELECTRICAL OUTLETS: ENSURE THAT ALL MOUNTING HEIGHTS OF ELECTRICAL DEVICES MEETA.D.A. REQUIREMENTS. 15. LIGHTING SWITCH PLATES: WHERE MULTIPLE SWITCHES ARE SHOWN PROVIDE (1) GANG BOX WITH A SINGLE COVERPLATE. 16. LIGHT FIXTURE PLACEMENT: CENTER CEILING ELEMENTS IN CEILING TILES, INCLUDING RECESSED DOWNLIGHTS, SMOKE DETECTORS, SPRINKLER HEADS, AND EXIi51GNS UNLESS OTHERWISE NOTED, 17. EMERGENCY LIGHTING: PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 18, FIRE ALARM SYSTEM: PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBESI. EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM Sr DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT I N CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE, CONSTRUCTION OCCURS 24. SUPPLEMENTAL HVAC/ELECTRICAL: IN THE EVENT THAT ANY SUPPLEMENTAL HVAC EQUIPMENT OR ABOVE BUILDING STANDARD ELECTRICAL POWER FACILITIES ARE INSTALLED (SUCH AS IN AN IT SERVER ROOM) CONTRACTOR SHOULD FURNISH AND INSTALL ADDITIONAL ELECTRICAL AND BTU SUB -METERING SO AS TO ENABLE OWNER TO MONITOR TENANTS UTILITY CONSUMPTION (IN RELATION TO THE SUBJECT EQUIPMENT) GOING FOR WARD. THE MAKE AND MODEL OF CONTRACTOR'S PROPOSED METERS SHOULD BE REVIEWED AND APPROVED BY OWNER PRIOR TO CONTRACTOR INSTALLATION. 21, ENGINEERED MEP DRAWINGS: WHEN REQUIRED BY STATE BUILDING CODE THE CONTRACTORS) SHALL PROVIDE DESIGN BUILD DRAWINGS FOR MECHANICAL, PLUMBING, ELECTRICAL, OR EFIRE NGINEER AND SUB DRAWINGS SHALL BE CERTIFIED BY A LICENSED ENGINEER AND SUBMITTED BY THE CONTRACTOR FOR STATE DESIGN REVIEW. 21, EQUIPMENT INSTALLATIONS: ALL EQUIPMENT AND/OR FIXTURES SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR INSTRUCTIONS. 27. BUILDING DIRECTORY: THE BUILDING AUTOMATION SYSTEM GRAPHIC AND PROGRAMMING TO BE UPDATED WITH NEW TENANT'S INFORMATION FOR FUTURE USE. 28. ELECTRICAL PANELS: ALL ELECTRICAL PANELS TO GET UPDATED CIRCUIT SCHEDULES. FIRE PROTECTION NOTES I. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. IY:IiA]1[�]TI��EeP�[�]Yt`T77\Y�PJ\7�J07FiY��EeEi77�J8Eq 7q 77_�yl11YIS# 2. DESIGN BUILD FIRE PROTECTION SYSTEM: FIRE PROTECTION WORK 15 TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 3. FIRE PROTECTION SYSTEM CODE COMPLIANCE: THE DESIGN/BUILD CONTRACTOR SHALL COMPLY WITH THE INDIANA BUILDING CODE, THE INDIANA FIRE CODE, AN D ALL OTHER APPLICABLE LAWS, CODES, RULES AND REGULATIONS THAT APPLY TO DESIGN AND INSTALLATION OF FIRE SPRINKLER/FIRE SUPPRESSION SYSTEMS. 4. FIRE PROTECTION DESIGN DRAWINGS: THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL PI F M(YgP nRAWINnc ANn RE ATEn nnrl INAP NTc WITH THE CTATE A NIT) 5. SPRINKLER HEADS: PROVIDE NEW OR RELOCATE EXISTING SPRINKII HEADS AS REQUIRED. PROVIDE MISSING COVER/ESCUTCHEON PLATES FOR SPRINKLER HEADS WHERE APPLICABLE. FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE START OF WORK EFFECTIVE CODES - GENERAL ADMINISTRATIVE RULES (675 AD 12) - INDIANA BUILDING CODE, 2014 EDITION (IBC, 2012 EDITION, 675 AC 13-2.6) - HANDICAPPED ACCESSIBILITY CODE: 2014 INDIANA BUILDING CODE CHAPTER 11, ANSI AI I7.1-2009, 6751AC 13-2.6-12) - INDIANA FIRE CODE, 2014 EDITION (IFC 2012 EDITION, 675 IAC 22-2.5) - INDIANA PLUMBING CODE, 2006 EDITION (675 IAC 16-1.4) - INDIANA ELECTRICAL CODE, 2009 EDITION (2008 NFPA 70, 675 IAC 17-1.8) - INDIANA MECHANICAL CODE, 2014 EDITION Thi 2012 EDITION, 675 IAC 18-1.6) - ENERGY CONSERVATION CODE, 2010 (ASHREA SO. 1, 2007 EDITION, 675 IAC 19.3) DOCUMENT APPROVAL 4. EQUIPMENT, FIXTURE, FINISH REUSE: WHERE EQUIPMENT, FIXTURES, OR FINISHES ARE MOVED FROM ANY OTHER PART OF THE BUILDING TO BE REUSED IN THE PROJECT AREA, THE CONTRACTOR SHALL INCLUDE IN THEIR SCOPE OF WORK ANY NECESSARY PATCHING OR REPAIRING OF THE REMAINING AREAS FROM WHERE THE ITEMS WERE RELOCATED, UNLESS OTHERWISE DIRECTED BY OWNER. 5. DECONSTRUCTION PLANS: REMOVE ALL EXISTING WALLS AND DOORS WHERE INDICATED BY NOTE, SYMBOL, OR DASHED LINES. NOTE THAT SOME ITEMS HAVE NOT BEEN SHOWN ON DECONSTRUCTION PLAN. VISIT AREA OF WORK TO ASSURE EXTENT OF DECONSTRUCTION. 6. FIELD VERIFICATION OF EXISTING CONDITIONS: REMOVE ALL CARPET, VINYL BASE, VCi, WALL FABRIC, AND ANY OTHER FINISHES AS REQUIRED FOR NEW CONSTRUCTION. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS. REFER TO FINISH PLAN/SCHEDULE FOR CLARIFICATION OF EXISTING FINISHES TO REMAIN. 7. PROTECTION OF BUILDING ELEMENTS TO REMAIN: USE CARE TO PROTECT EXISTING BUILDING ELEMENTS INDICATED ON THE DRAWINGS TO REMAIN SUCH A5, BUT NOT LIMITED TO, EXISTING CEILING GRID, TILES, FIRE SUPPRESSION EQUIPMENT, DIFFUSERS, LIGHT FIXTURES, EQUIPMENT, CASEWORK, AND FINISHES. THE CONTRACTOR SHALL REPLACE AND/OR REPAIR, AT THE CONTRACTOR'S COST, ANY SUCH ELEMENTS DAMAGED DURING CONSTRUCTION THAT COULD HAVE OTHERWISE BEEN REASONABLY PROTECTED AND MAINTAINED IN GOOD CONDITION FOR THE OWNER'S USE IN THE PROJECT. 8. REMOVAL OF ABANDONED CABLING& WIRING: PER THE INDIANA ELECTRICAL CODE (SPREAD OF FIRE OR PRODUCTS OF COMBUSTION) REMOVE ALL ACCESSIBLE PORTIONS OF ABANDONED CABLES AND WIRING INCLUDING BUT NOT LIMITED TO: DATA WIRING, COMMUNICATIONS WIRING, FIRE ALARM CABLES, AUDIO CABLES, COAXIAL CABLES, FIBER OPTIC CABLES RACEWAYS, AND PLTC CABLES REFER i0 SECTION . ANY SUCH CABLE OR WIRING SHOULD BE PULLED AND REMOVEDVED BBACK i0 THEIR MAIN SOURCES ON THE FLOOR (I.E. ELECTRICAL PANELS, PHONE BOARDS, ETC.) 9. PROTECTION OF ABANDONED/TERMINATED BUILDING SYSTEM ELEMENTS: WHERE FIXTURES OR EQ UI FIVE NT A RE REMOVED FROM ANY ELECTRICAL, PLUMBING, MECHANICAL, OR VOICE/DATA SYSTEMS, ALL REMAINING TERMINATIONS SHALL BE CLOSED AND PROTECTED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND GOVERNING SAFETY REGULATIONS OR PROCEDURES. MARK, LABEL, OR FLAG ALL TERMINATED SYSTEMS FOR FUTURE REFERENCE, CONTRACTOR TO PROVIDE AN "AS -BUILT' SET INDICATING THE LOCATION OF ALL PERMANENTLY ABANDONED SYSTEMS. 10. HAZARDOUS MATERIALS: GENERAL CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING ANY AN D ALL ITEMS THAT MAY CONTAIN HAZARDOUS OR HARMFUL MATERIALS. ALL IDENTIFIED ITEMS MUST BE PROPERLY DISPOSED OF PER EPA AND INDIANA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT RULES AND REGULATIONS, TENANT/CLIENT, UPON SIGNATURE, APPROVES ALL ASPECTS OF THE SCOPE OF WORK CONTAINED IN THESE DOCUMENTS. TENANT/CLIENT COMPANY NAME DATE TENANT REPRESENTATIVE SIGNATURE TENANT REPRESENTATIVE PRINTED NAME ALL COSTS INCURRED DUE TO ANY CHANGES REQUESTED AFTER SIGN -OFF OF THESE DOCUMENTS SHALL BE THE FULL RESPONSIBILITY OF THE TENANT/CLIENT. THESE DRAWINGS, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOTT DESIGN. LLV HE WITH JDARDS o O N SN V !_ ALL ii-n m n Z -'- D O ED 10 LL N w O M U cD 33 Qa 43 WO V 3 ALTE -V MINATE, NINGS B.T;Zi1Re791:13s�J781CKRPaIY:BG]Ei]G 6. MILLWORK REQUIREMENTS: REFER TO MILLWORK SECTION ELEVATIONS. UN LESS OTHERWISE SHOWN, PLASTIC LAMINAT ;LAD, COUNTERTOPS WITH 4" BACKSPLASHES WHERE INDICATED. BACKSPLASHES TO BE FIELD APPLIED. REFER TO MILLWORK SI IONS & ELEVATIONS FOR CABINETRY SPECIFICATIONS (CUSTOM PLF C LAMINATE OR PRE -MANUFACTURED STOCK CABINETRY). ED 5OF PLASTIC LAMINATE COUNTERTOPS, CABINETS AND DRAWER: ERE PLASTIC LAMINATE AND NOT PVC OR OTHER STOCK PLASTIC )GING UNLESS NOTED OTHERWISE. 7. MILLWORK WALL BLOCKING: TO PROVIDE BLOCKING IN N LS FOR ALL MILLWORK WALL STOPS HARDWARE AND CABINETRY' ERE SPECIFIED. ALL WOOD BLOCKING TO BE FIRE RATED. it I IR[,t lvmelV YA .. THIS DRAWING. AND ME IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT ME WRITTEN CONSENT OF SCHOII DESIGN. VICIP'.Y MAP NOT TO SCALE KEY PLAN - 2ND FLOOR N NOT TO SCALE C INDEX OF DRAWINGS TIII COVER SHEET AND GENERAL PROJECTNOTES LI00 LIFE SAFETY PLAN DI I I DECONSTRUCTION PLAN AIII ARCHITECTURAL PLAN/ELECTRICAL PLAN/DOOR SCHEDULE A121 REFLECTED CEILING PLAN A131 FINISH PLAN N W ui IV Ra•aR� y N Z1• ocy, 300 J m �O O JZ 44 In Z J ZN� OLU< aaaaaa� IV Z �O UmU 0 Li ISSUE DATE DESCRIPTION 08.28.19 REVIEW SET 09.03.19 PERMIT SET REVISIONS MARK DATE I DB DESCRIPTION IN 0. AR10700017 STATE OF PROJECT NUMBER 2019.330 PROD. MGR DRAWN BY I BW CRIB 2ND FLOOR COVER SHEET AND GENERAL NOTES T111