Loading...
HomeMy WebLinkAboutA001 LIFE SAFETYLEGEND EP EXISTING ELECTRICAL PANEL LOCATION EX EXISTING EXIT- BUILDING EXIT LOCATION FE FIRE EXTINGUISHER 0 EXITSIGNAGE EMERGENCY LIGHTING NIL NIGHT LIGHT/EMERGENCY LIGHTING, REFRENCE A200 FOR LOCATION. ■ AREA NOT IN CONTRACT ❑ AREAOFWORK RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel CODE SUMMARY SCOPE OF WORK: OFFICE SPACE BUILD -OUT REMODEL TO PREVIOUSLY BUILT -OUT OFFICE. OCCUPANCY CLASSIFICATION: B(USINESS) CHANGE OF OCCUPANCYCLASS: NO TOTAL BUILDING AREA: 33,01 SF/FLOOR 4 STORIES = 135,296 GROSS SF TOTAL AREA ON FLOOR: 33,590 SQ.FT. TOTAL PROJECT AREA: 14,382 SOFT. OCCUPANCY CALCULATIONS SPACE TYPE AREA SF PER OCCUPANT OCCUPLOAD GENERAL OFFICE 14,382 100 141 TOTAL OCCUPANTS IN PROJECT AREA:93 NUMBER OF REQUIRED EXITS: 2 SPRINKLER SYSTEM (YES/NO): YES -EXISTING TO REMAIN FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED) N/A APPLICABLE CODES: ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING BUILDING CODE 2014 INDIANA BUILDING CODE (2012 IBC WITH STATE AMENDMENTS) STRUCTURAL CODE 2008 INDIANA BUILDING (20061BC, ASCE-7-2005) PLUMBING CODE 2012 INDIANA PLUMBING CODE MECHANICAL CODE 2014 INDIANA MECHANICAL CODE (2012 IMC WITH STATE AMENDMENTS) ELECTRICAL CODE 2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMENDMENTS) FIRE/LIFE SAFETYCODE 2014 INDIANA FIRE CODE (2012 IFC WITH STATE AMENDMENTS) ACCESSIBILITY CODE 2014 INDIANA BUILDING CODE, CHI I -ACCESSIBILITY, ANSI A-117.1 STANC ADA ACCESSIBILITY GUIDELINES - 2009 EDITION ENERGYCODE 2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007) WITH INDIANA AMMENDMENTS GENERAL ADMINISTRATIVE RULES 2ND EDITION. GENERAL NOTES 1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBES), EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA). 3. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP, IS NOT RESPONSIBLE FORTHE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 4. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. 5. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 6. REFER TO SHEET Al 00 FOR WALL TYPE AND CONSTRUCTION DETAILS 7. EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCESTO REMAIN. a E 7 a K y � z n v p m0 J c,p m J G<m Z m uCA I�Im ca F z a �a z @ n Lis t. w82R 38d m11 O � a w m s � ut m ¢ p vi n a w DO 0) Nm o u� o N 3 Ue u0 ¢ U in 30 0 ° u u a N V• O 0 r— 0 ^= DO VW rq i 1D L 3 � Y Z d Vl O 0 rt ro OMMEN i M U1 f0 v ' a C G 0 v4Y'e'" 19600042 '. sT TE of = I. ny un LIFE SAFETY A001 Vlq�,o+AC11b1N� DATE: 10/14/19