HomeMy WebLinkAboutA100 FLOOR PLANFLOOR PLAN
1 /8" = 1'-0"
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Cannel
LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
7 WALL
Joi�DOORAND
FRAME
(SEE DOOR
SCHEDULE)
O WALL
II DOOR AND
Ifl// IIIIIILI FRAME
NOTE: IF IN GOOD CONDITION, EXISTING DOORS
SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR
NEW DOORS.
■ AREA NOT IN CONTRACT
❑ AREAOFWORK
WALL TYPES
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL
WALLS ARE TO BE [W 1] UNLESS OTHERWISE NOTED. NOT ALL WALL TYPES
LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO
REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
GENERAL NOTES
1. UNLESS OTHERWISE NOTED OR KEYED ON FLOOR PLAN, ALL NEW
WALLS TO BE TYPE W 1.
2. CLEAN EXISTING EXTERIOR WINDOW BLINDS. REPAIR DAMAGED
BLINDS WITH NEW TO MATCH BUILDING STANDARD.
3. PROVIDE BRACING AND FIRE -TREATED BLOCKING AS REQUIRED IN
WALLS SUPPORTING CASEWORK, TACKBOARDS/MARKERBOARDS,
RESTROOM ACCESSORIES, EQUIPMENT, OR ANY OTHER MISC. ITEM
REQUIRING ADDITIONAL SUPPORT.
4. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO
NFPA 10. COORDINATE WITH O W NERJLANDLORD ON
EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE
OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
5. WHERE PLAN INDICATES EXPOSED DECKAT EXTERIOR WALLS,
CONTRACTOR TO INCLUDE PROVIDING, INSTALLING, AND
FINISHING THE DRYWALL ABOVE THE WINDOW HEADER AT THE
EXTERIOR PERIMETER WALLS AS REQUIRED.
6. PROVIDE BLOCKING AS NEEDED FOR WHITE BOARDS. ALL WHITE
BOARDS TO BE INSTALLED AT 60" AFF TO CENTER UNLESS NOTED
OTHERWISE. CONFIRM LOCATIONS/ INSTALL HEIGHT WITH TENANT
PRIO R TO INSTALLATION.
STANDARD INSULATED ----
KEYED NOTES
OWALL
W1
3-5/8"METAL STUDS AT 16"
O.C.; ONE LAYER OF 5/8"
TYPE "X"GYPSUM BOARD
1
FIXED WALL MOUNTED TELEVISION SUPPLIED BYOWNER.
EACH SIDE; EXTEND WALL
CONTRACTOR INSTALLED. COORDINATE EXACT LOCATION WITH
TO UNDERSIDE OF CEILING.
TENANT.
PROVIDE BATT SOUND
2
ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
INSULATION INSIDE WALL
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW
AND TI SOUND
WALLSARE IN LINE W ITH EXISTING WALLS.
INSULATION EACH SIDE OF
3
PROVIDE NEW WALL HUNG FIRE EXTINGUISHER CABINETS.
WALL ABOVE CEILING.
PLACEMENT IS FOR GENERAL REFERENCE. ALL EXTINGUISHERS
SHALL BE PLACED IN ACCORDANCE W ITH NFPA 10.
PARTIAL HEIGHT WALL _ _ _
_ _ 4
EXISTING FIRE EXTINGUISHER CABINET TO REMAIN.
W2
35/8"METAL STUDSAT
EL
5
PROVIDESINGLE BOWL STAINLESSSTEEL UNDERMOUNT SINKAND
16" O.C.; ONE LAVER OF
FAUCET. PROVIDE GARBAGE DISPOSAL, LIGHT COMMERCIAL
5/8" TYPE 'I GYPSUM
MODEL. PROVIDE PUSH BUTTON ON/OFF AT SINK/COUNTER FOR
BOARD EACH SIDE;
GARBAGE DISPOSAL IN LIEU OF SWITCH. SINK- ELKAY,
EXTEND WALL TO 3'-411;
CROSSTOWN OECTRU24179R(STAINLESS STEEL) FAUCET- DELTA,
PROVIDE 1"STEEL PIPE
MATEO SINGLE -HANDLE PULL DOWN #9183-AR-DST (ARCTIC
ANCHORS INTO
STAINLESS FINISH) A100
CONCRETE FLOOR FOR
6
PROVIDEWATER LINE FOR COFFEEAND REFRIGERATOR. CONFIRM
SUPPORTAS REQUIRED.
LOCATION WITH TENANT,
PROVIDE SSi CAP AND
T
PANTRYACCESS DOORSTO MATCH ADJACENT CASEWORK. REFER
PLi ATALL EXPOSED DRY
TO INTERIOR ELEVATIONS ON A500 FOR FURTHER INFORMATION.
WALL SIDES. REFER TO
8
CASEWORK OR COUNTERTOP. REFERTO SEEA500.
DETAIL 101
9
VERTICAL WOOD LOOK BEAMSTO TRANSITION TO CEILING. REFER
TO A500 AND REFLECTED CEILING PLAN FOR FURTHER
PARTIAL HEIGHT WALL
INFORMATION.
W3
35/8"METAL STUDSAT
10
14'LX2'WX1'I WOOD PLANTER BOX. PROVIDE WATERPROOF
16" O.C.; ONE LAYER OF
PLANTER LINERAS REQUIRED.
5/8"TYPE 'I GYPSUM
11
DISHWASHER SUPPLIED BY TENANT, CONTRACTOR
BOARD EACH SIDE;
INSTALLED.000RDINATE ANY PLUMBING LINES NEEDED WITH
EXTEND WALL TO 611
TENANT.
PROVIDE 1"STEEL PIPE
ANCHORS INTO
CONCRETE FLOOR FOR
SUPPORTAS REQUIRED.
PROVIDE SSi CAP AND
PLi ATALL EXPOSED DRY
WALL SIDES. REFER TO
DETAIL 10/A500
STANDARD INSULATED--
TO DECK
OWALL
W4
3-5/8"METAL STUDS AT 16"
O.C.; ONE LAVER OF 5/8"
TYPE "X"GYPSUM BOARD
EACH SIDE; EXTEND WALL
TO UNDERSIDE OF DECK.
PROVIDE BATTSOUND
INSULATION INSIDE WALL
AND TI SOUND
INSULATION EACH SIDE OF
WALL ABOVE CEILING.
PLUMBING RISER DIAGRAM
TYPICALL ALL SINGLE LOCATIONS NOT TO SCALE
2" VENT TO
`S MAIN BLDG. VENT
it
N
SINK
C.O.
rkj
a E
7
a
K < �
v
z n
N 9
p m<3
rnry
c
id
J < q
ju. V
`w o
a b^
a c n
L Im ca
F
z
u
�a
z S
rn egg t�.
w 82
i8d
m�1=
O
�
a
w
a
U
m
¢
w
0
�
Q
p
ry
a
w M toCn
57
�N
III9
m
m
z
�
uIII
r�'N
o
3�'
w�
un
¢ In
COw
°ry
O
O
"
a
Q
O
1j 0
W/ W
i (lS rq
L!]
L Y Z
Z
r
ra
d LIT
� (1
O CL
rt
> C
COy f0 O
C
C
�
V) a
c
G. o
N
`\\`\\oannnNmnuoi
�t�V�Tsr,
v4Y'os
= 19600042 '.
_
ST TE OF =
I.
ny un
FLOOR PLAN
A100
DATE: 10/14/19