Loading...
HomeMy WebLinkAboutA200 REFLECTED CEILING PLANRELOCATE DIFFUSERS AND EXISTING VAV BOXESOR PUMP AND MAIN SUPPLY DUCTSTOREMAIN MECHANICAL DIFFUSER RELOCATION NOT TO SCALE *REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION REFLECTED CEILING PLAN 1/8 if = 11_011 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and focal Codes City of Carmel LEGEND GENERAL NOTES 4174 EMERGENCYLIGHT 1. REUSE EXISTING CEILING GRID UNLESS OTHERWISE NOTED. FIXTURE EXISTING GRID IS 2'x4'AT 9'1 REPAIR ANY DAMAGED GRID AND PAINT GRID WHITE AS REQUIRED. EXIT LIGHT FIXTURE 2. REPLACE ALL DAMAGED OR DIRTY CEILING TILESWITH NEW TO MATCH EXISTING. PROVIDE LIKE TILES IN INDIVIDUAL ROOMS TO ® EXHUSTFAN CREATE UNIFORM LOOK. 3. WHERE MULTIPLE SWITCHESARE SHOWN, PROVIDE(1) GANG BOX ® LIGHT FIXTURE, 2k2', LED WITH A SINGLE COVERPLATE. MFG: COOPER LIGHTING STYLE: 2X4 METALUX LED 4. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED MODEL: PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED ® PI LIGHT FIXTURE, DRUM PENDANT IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN INSTALL AT X'-X" ARE TO ON PLAN ARE FOR REFERENCE ONLY. BOTTOM OF FIXTURE ALLOWANCE:$9501 5. LIGHTING PLACEMENT AND QUANTITIES ARE FOR REFERENCE ONLY AND ARE TO BE PROVIDED BY LIGHTING CONSULTANT AND ® P2 LIGHT FIXTURE, DRUM PENDANT ELECTRICIAN. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR INSTALL AT X'-X" ARE TO VERIFYING THAT LAY -OUT AND TOTAL WATTAGE MEETS ASHRAE BOTTOM OF FIXTURE 90.1 STANDARDS AND LIGHT LEVELS ARE APPROPRIATE FOR THE ALLOWANCE: $950/EA USE OF EACH SPACE. OVER 50% OF THE LIGHTING WILL BE ® P3 LIGHT FIXTURE, DRUM PENDANT REPLACED WITH NEW, SOASHRAE WATTAGE REQUIREMENTS WILL INSTALL AT %'-%" AFF TO NEED TO BE MET. BOTTOM OF FIXTURE ALLOWANCE:$950/EA 6. UNLESS NOTED OTHERWISEALL NEW SWITCHES MUST BE AN OCCUPANCY SENSOR COMBO UNIT W ITH BOTH ULTRASONIC AND ® P4 LIGHT FIXTURE, PENDANT INFRARED TECHNOLOGYWITH A ONE BUTTON OVERRIDE. EUREKA LIGHTING - LILY, BLACK OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT INSTALL ATVARYING HEIGHTS OCCUPANCY WITHIN ANY PORTION OF INCLUDEDAREA IS DETECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS 0 CI RECESSED LIGHT FIXTURE IN OPEN AREAS AS REQUIRED. MFG: HALO LIGHTING STYLE: 6 LED DOWNLIGHT T. CAN LIGHT FIXTU RES TO BE SWITCHED SEPARATELY AND HAVE MODEL: ML5612835 DIMMERS. UCI LED UNDER CABINET LIGHT 8. ALL EXPOSED ACOUSTICAL CEILING TILE EDGES TO BE FINISHED HALO HU10 24" WITH 4" WHITE AXIOM TRIM UNLESS NOTED OTHERWISE. LIGHTCIRCUIT 9. ALL DEVICESAND COVERS TO BE WHITE. b 10. ALL DRYWALL CEILINGS TO BE PAINTED PTI UNLESS NOTED LIGHTSWITCH OTHERWISE. $3 LIGHTSWITCH, 3-WAY 11. ALL BULKHEADS TO BE CONSTRUCTED USING METAL STUDS, NOT CEILING GRID AND WIRE SUPPORTS. b. LIGHTSWITCH, 4-WAY $b LIGHTSWITCH, DIMMER R REUSE AND RELOCATE MECHANICAL NOTES EXISTING LIGHT 1. SCOPE INTENT IS FOR EXISTNG MECHANICAL SYSTEMS TO REMAIN. EXISTING CEILING GRID, EXISTING FLEX DUCTAND DIFFUSERS BEING RELOCATED AS �F SUSPENDED, TI NECESSARY PER WALL LAYOUT. NO MAIN DUCTWORK BEING RELOCATED. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR — NEW WOOD CEILING NOTIFYING APPLICABLE PARTIES IF ADDITIONAL WORK IS BEAMS WRAPPED IN REQUIRED. PLASTIC LAMINATE OR REWORK HVAC SYSTEM FOR NEW LAYOUT, TEST AND BALANCE SYSTEM. CEILING TYPE X CEILING HEIGHT X'-X" 2. DIFFUSER LOCATIONSARE SHOWN ON PLAN FOR REFERENCE ONLY, CONTRACTOR IS TO PLACE LOCATION OF DIFFUSERS AND RETURN AIR GRILLES AS REQUIRED BY CODE. 3. FIRE STOPANY EXISTING DECK PENETRATIONS AS REQUIRED. DIFFUSER, LAY -IN, TI 4. LOCATE THERMOSTATS WHERE APPROPRIATE PER MECHANICAL DESIGN. ALL THERMOSTATS TO HAVE LED DISPLAY WITH LOCKOUT CAPABILITY AND LOCK BOX. VERIFY LOCATIONS WITH TENANT DIFFUSER, LAY -IN, I'x4' BEFORE INSTALLING. ® DIFFUSER, LAY-IN,4"1 5. WHERE EXPOSED DECK IS SHOWN, VERIFYWITH DESIGNERAND TENANT IF DUCTWORK SHOULD BE SPIRAL DUCT. NOTE: IF IN GOOD CONDITION, EXISTING H.VA.C. DEVICES AND CEILING TILES SALVAGED FROM DEMOLITION CAN BE KEYED NOTES SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET. I EXISTING CEILING TO REMAIN. PROVIDE NEW LIGHTING AS SHOWN. ■ AREA NOT IN CONTRACT 2 NEW PLASTIC LAMINATE 4.5"X 4.5" BEAMS TO BE INSTALLED AT 9'-I"A.F.F 3 PATCH CEILING/GRID AS REQUIRED WHERE DEMO HAS OCCURED. ❑AREA OF WORK 4 PROVIDEALTERNATE TO REPLACE EXISTING CAN LIGHTS WITH NEW CAN LIGHTS IN THIS LOCATION. ❑AREA OF WORK IN CONTRACT, 5 NEW EXHAUST FAN IN THIS LOCATION TO RUN IOCFM EXISTING CEILING TO REMAIN CONTINUOUSLY. nk a 0 7 O 2 yt VIGfiTOGHT v o mg3 rnry 5�w L m ca F z PH NN z op � w eC urgg t�. wf SRI, R 3$d O P: DID ut U 0 Q O NO DID OR a p 16 ry a w Do 0) LID � C m m 0 u o N ¢ OLD u^ OLD m OO 5 0 O ° u a p O ^' V) O V/ 00 ko L 3 � Y Z Co d N c3 p rt ro > C M TO ' ) a C G o uT \"„000mllN,,,uo, Tsr S'�RE v4YRe'" = 19600042 '. _ ST TE OF = I. ny un REFLECTED CEILING PLAN A200 IN COACH OR REM USENTED) UP T15E DROINEGARE USED OF OR DISCLOSED TO QN1 FORD) FIT" OR GERD FEW ANN THUS N ITATEFFIRM WITHOUT THEW RITTEN CONSENT OF COUPLET DESIGN GROUP INC MUST IS NOTIFIED OF My DIFOREFEENGERS OR VERSIONS FROM THE DIM ON THE POUR DATE: 10/14/19