Loading...
HomeMy WebLinkAboutA300 POWER & DATAPOWER AND DATA PLAN 1 /8" - 1 _N„ RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel DATE: 10/14/19 GENERAL NOTES 1. ALL OUTLETS AND COVERS AND SWITCHES AND SWITCHPLATE COVERS TO MATCH EXISTING WHITE. 2. AT EACH PHONE/DATA JACK, PROVIDE PULL STRING FROM ABOVE CEILING TO BOX. TENANTS DATA CONTRACTOR IS RESPONSIBLE FOR PU LLING CONDUCTORS AND PROVIDING APPROPRIATE TEMINAL AT FACE PLATE. 3. ALL ELECTRICAL OUTLETS WITHIN 5'-0" OF WATER ARE TO BE GFI. 4. OWNER TO SUPPLY, INSTALL AND PAY FOR SECUTIRY SYSTEMS (I.E. MAIN SECURITY CONTROL PANEL & MOTION DETECTORS.) MAIN SECURITY CONTROL PANEL TO BE LOCATED IN THE ELECTRICAL ROOM. 5. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. ARE TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTE OTHERSW ISE. 6. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING JUNCTION BOX LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES AND CARD READERS. ELECTRIC STRIKES AND CARD READERS ARE TYPICALLY INSTALLED BY THE TENANTS SECURITY CONTRACTOR AND ARE TYPICALLY NOT SPECIFIED BY PARALLEL DESIGN GROUP. T. ALL OUTLETSARE TO INSTALLED 1811 MIN.A.F.F.TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. 8. REFERTO DOOR SCHEDULEAND COORDINATE WITH TENANT/OWNER REGARDING JUNCTION BOX LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES AND CARD READERS. ELECTRIC STRIKES AND CARD READERS ARE TYPICALLY INSTALLED BY THE TENANTS SECURITY CONTRACTOR AND ARE TYPICALLY NOT SPECIFIED BY PARALLEL DESIGN GROUP. LEGEND cx= POWER OUTLET, DUPLEX OCE POWER OUTLET, QUADRUPLEX O JUNCTION BOX CEILING MOUNTED JUNCTION BOX 0 BOX, BLANK COVER PLATE QO BOX,OPEN P ❑ POWER AND DATA POLE FLOOR BOX W ITH JUNCTION BOX AND DATA, FLUSH MOUNTED d FLOOR BOX WITH POWER AND DATA, FLUSH MOUNTED DATA/COMMUNICATION OUTLET (PROVIDE BOX AND PULL STRING ONLY) N NEW E EXISTING TO REMAIN DED DEDICATED CIRCUIT GFI GROUND FAULT CIRCUIT INTERRUPT OUTLET +44" HEIGHT OF ELECTRICAL OR DATA DEVICE HE DATA HD HDMI KEY NOTES 1 PROVIDEJUNCTION BOX ABOVE CEILING FOR PENDANT LIGHT. COORDINATE LOCATION WITH DESIGNER IN FIELD. 2 APPROXIMATE LOCATION OF WALL MOUNTED TELEVISION SUPPLIED BYTENANT, CONTRACTOR INSTALLED. COORDINATE EXACT LOCATION WITH TENANT. ■ AREA NOT IN CONTRACT ❑ AREA OF WORK s z d b m o mg3 J C I REM J MrT u 'b^ Lai 0) c a F 9 z a Yai z S -0 t . Wins F°PC w_So c:§s 38x O_ a w ut uDO t ¢ o0 DO wTOO to Q) I i m so z E N o 3 U o Q w u0 00 ° u a r,4 0) O C 0 r— N(En 00 to i 3 � Y Z a. viB 0 ro ro c m> a to � c aJ a On g I U I I I I l l I pYY `\\`\\\`11 r S' �At��V isBE Ee v4YNo = 19600042 '. _ ST TE OF = q1 IA P.� I. Y ny un POWER AND DATA A300