HomeMy WebLinkAboutApplicationPage 1 of 12 Filename: development standards variance application & instructions 2019 Revised 01/10/19
CARMEL BOARD OF ZONING APPEALS
DEVELOPMENT STANDARDS VARIANCE APPLICATION
FILING FEES: Single Family (Primary Residence) $350.00 for the first variance, plus $105.00 for each additional
section of the ordinance being varied. All Other $1,394.00 for the first variance, plus $657.00 for each
additional section of the ordinance being varied. (Or see Hearing Officer option & Fees.)
DOCKET NO. ________________________________ DATE RECEIVED:_______________________________
1)Applicant: _____________________________________________________________________________
Address: _____________________________________________________________________________
2)Project Name: __________________________________________ Phone: ________________________
Engineer/Architect:______________________________________ Phone: _________________________
Attorney:_______________________________________________ Phone: ________________________
Contact Person:__________________________________________Phone:________________________
Email:_______________________________________________________________________________
3)Applicant's Status: (Check the appropriate response)
______ (a) The applicant's name is on the deed to the property _____(b)The applicant is the contract
purchaser of the property. (c) Other: ______________________________
4)If Item 3) (c) is checked, please complete the following:
Owner of the property involved: __________________________________________________________
Owner's address: __________________________________________ Phone:_____________________
5)Record of Ownership: Deed Book No./Instrument No.___________________________________________
Page: ______________________ Purchase date: _____________________________________________
6)Common address of the property involved: ___________________________________________________
Legal Description: ______________________________________________________________________
Tax Parcel ID No.:__________________________________________________________________
7)Explanation of requested Development Standards Variance: (State what you want to do and cite the
section number(s) of the Unified Development Ordinance that applies and/or creates the need for this
request.)
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
8)Reasons supporting why the BZA should grant the Development Standards Variance: (Additionally,
complete the attached question sheet entitled "Findings of Fact-Development Standards Variance").
_____________________________________________________________________________________
_____________________________________________________________________________________
Office Use Only
Install masonry based ground sign, to include name of business, 10' from the City right of way .
Requesting development standards variance due to Article 5 Section 5.39 D-3 "Off premise signs
prohibited."
Linda Thompson
4301 West William Cannon Dr., STE B150 #300
Caliber Collision- Carmel, IN 512-203-9289
Linda Thompson 512-203-9289
linda.thompson@creeindustrialarts.com
Stephen Rice
505 W Carmel Drive Carmel, IN 46032 (317) 846-1201
503 W Carmel Drive Carmel, IN 46032
Acreage 1.99, Section 36, Township 18, Range 3
Represantive for Owner/Tenant
29-09-36-000-047-001-018
en Rice
The I1 zoning intent is to provide for a wide variety of industrial, commercial use without producing serious adverse effects and
preserving the land. Due to the location of the business in relation to parking lot entrance, and public view the proposed ground
sign would allow for the community to be aware of business location and services offered, without obstructing line of sight at
right of way. The proposed ground sign would meet all compliance standards, including size, masonry base, and landscaping.
Page 2 of 12 Filename: development standards variance application & instructions 2019 Revised 01/10/19
9)Zoning district classification of property: _________________________________________________
9a) Overlay Zone of property (if applicable):___________________________________________________
10)Size of lot/parcel in question: ____________________________________________________acres/sq.ft.
11)Present use of property: ______________________________________________________________
12)Describe proposed use of property: __________________________________________________
_____________________________________________________________________________________
13)Is the property: Owner occupied __________ Renter occupied _________ Other ___________________
14)Are there any restrictions, laws, covenants, variances, special uses, or appeals filed in connection with this
property that would relate or affect its use for the specific purpose of this application? If yes, give date and
docket number, instrument no., decision rendered and pertinent explanation. ________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
15)Has work for which this application is being filed already started? If answer is yes, give details:
Building Permit Number: _________________________________________________________________
Builder: ______________________________________________________________________________
16)If proposed appeal is granted, when will the work commence?
_____________________________________________________________________________________
17)If the proposed variance is granted, who will operate and/or use the proposed improvement for which this
application has been filed?
_____________________________________________________________________________________
NOTE: Three modes of public notice are required.
LEGAL NOTICE shall be published in the NEWSPAPER according to the Chart on page 5
MANDATORY 20 days prior to the public hearing date. The certified "Proof of Publication" affidavit for the
newspaper must be available for inspection by the night of the hearing.
LEGAL NOTICE to all adjoining and abutting property owners is also MANDATORY; two methods of notice
are recommended:
1)FIRST CLASS MAIL with CERTIFICATE OF MAILING sent to adjoining property owners. (The white
receipt should be stamped by the Post Office at least 20 days prior to the public hearing date), OR
2)HAND DELIVERED to adjoining and abutting property owners (A receipt signed by the adjoining and
abutting property owner acknowledging the 20 day prior notice should be kept for verification that the notice was
completed)
LEGAL NOTICE via a Notice of Public Hearing SIGN posted on the property is also required; see page 8.
THE BURDEN OF PROOF FOR ALL NOTICES IS THE RESPONSIBILITY OF THE APPLICANT.
The applicant understands that docket numbers will not be assigned until all supporting information has been
submitted to the Department of Community Services.
Applicant Signature: ____________________________________________________ Date: _______________
The applicant certifies by signing this application that he/she has been advised that all representations of
the Department of Community Services are advisory only and that the applicant should rely on
appropriate Unified Development Ordinance and/or the legal advice of his/her attorney.
Warehouse
Commercial Warehouses
1.99/86684
Collision Center
Auto body repair shop
ASAP
Caliber Collision
October 14, 2019
I ; I1
Page 11 of 12 Filename: development standards variance application & instructions 2019 Revised 01/10/19
FINDINGS OF FACT SHEET - DEVELOPMENT STANDARDS VARIANCE
CARMEL ADVISORY BOARD OF ZONING APPEALS
(Petitioner fills out 1-3 and first 2 blanks)
Docket No.: _______________________________________________
Petitioner: _______________________________________________
1.The approval of this variance will not be injurious to the public health, safety, morals and general welfare of
the community because:
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
2.The use and value of the area adjacent to the property included in the variance will not be affected in a
substantially adverse manner because:
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
3.The strict application of the terms of the Unified Development Ordinance to the property will result in
practical difficulties in the use of the property because:
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
DECISION
It is therefore the decision of the Carmel Board of Zoning Appeals that Development Standards Variance Docket
No. ___________________________ is granted, subject to any conditions stated in the minutes of this Board,
which are incorporated herein by reference and made a part hereof.
Adopted this _______________ day of __________________________________, 20 _______.
_____________________________________________ _____________________________________________
CHAIRPERSON, Carmel Board of Zoning Appeals
_____________________________________________ _____________________________________________
SECRETARY, Carmel Board of Zoning Appeals
Conditions of approval of the Board, if any, are listed on the Letter of Grant.
The proposed ground sign will be Unified Development Ordinance compliant and will not hinder line of vision due to
size and set back spacing from city right of way. Multiple adjacent property owners in same zoning area with similar
warehouse placement, including previous tenant of said property at which variance is being requested, have been
granted compliant, off premise signage.
The proposed ground sign will not block or hinder access to any adjacent properties or business signs due to size
and set back spacing from right of way. In addition, proposed sign would not be in direct competition or placement
to previously approved on or off premise signage.
Without placement of proposed sign, potential customers could be unable to locate business or might become confused
with actual business entrance. Customer confusion and difficulty accessing business could potentially harm business
finances if unable to provide services to community.
CALIBER COLLISION/ CHANNEL LETTERS/ CARMEL
LISTED
MEMBER
INTERNATIONAL SIGN ASSOCIATION
Account Rep: Robert
Project Manager: Brandon
Quantity: ONE (1)
Total Sq.Ft: 23 ft
Returns: 5” Black
Trimcap: 1” Black
Face: 7328 White Plex
First-surface translucent vinyl:
• Digital Print for rainbow strip
Illumination: White LED’s
NOTES:
• Individually Mounted Letters
• White interiors for increased illumination
• All paint two-stage automotive acrylic MOUNTING OPTIONSB MONUMENT SIGN
3/4” = 1’-0”
B MONUMENT SIGN
1/2” = 1’-0”
3"
N.T.S.1/4" DRAIN HOLES
LED
.080" ALUMINUM
CHANNEL LETTER - TYPICAL SECTION - REVERSE-LIT
.063" ALUMINUM3" RETURN PRIMARY ELECTRICAL(NEC 600-5) SEE ELEC. NOTES
FASTENERS ASREQ'D. BY LOCALJURISDICTION
ALUMINUMENCLOSURE
ELECTRICAL NOTES
LED POWER SUPPLYLISTED BUSHING
.19" CLEAR LEXAN™
SPACER
• Fabricate and install one (1) D/S illuimated cabinet
• Flagstone base to match architects’s drawints
• Brick veneer / Hanson Century Plus V224 Velour
• All structural systems are based on provided
engineering and are to be implemented as such
Date: Aug 22 2019
Drawn by: Zach
Drawing #: 30149bv2s1_cc_carmel_in_
wstcarmel_dr
Job #: 30149
Project/ Location:
503 West Carmel Dr.,
Carmel, IN 46032
8'-8 1/8"
1'-1 1/4"
11'-6 1/2"
5'-5 1/2"
5'-9 3/4"
2'-4"
2'-7 1/2"
Electrical Supply
Conrete Footer
Stone to match buidling
Brick
2'-6"
2'-7 1/2"
4'-11 1/2"
Conrete Footer
Electrical Supply
Access Door
1'-6"
1'-2 1/2"
3'-4"
6'-10 3/4"
B MONUMENT SIGN
1/2” = 1’-0”
B MONUMENT SIGN
1/2” = 1’-0”
10'-6"
2"2"2"2"2"2"
2'-6"
CALIBER COLLISION/ CHANNEL LETTERS/ CARMEL
LISTED
MEMBER
INTERNATIONAL SIGN ASSOCIATION
Account Rep: Robert
Project Manager: BrandonDate: Aug 22 2019
Drawn by: Zach
Drawing #: 30149bv2s2_cc_carmel_in_
wstcarmel_dr
Job #: 30149
Project/ Location:
503 West Carmel Dr.,
Carmel, IN 46032
3"
1/4" DRAIN HOLES
LED
.080" ALUMINUM
.063" ALUMINUM
3" RETURN
PRIMARY ELECTRICAL
(NEC 600-5) SEE ELEC. NOTES
FASTENERS AS
REQ'D. BY LOCAL
JURISDICTION
ALUMINUM
ENCLOSURE
LED POWER SUPPLY
LISTED BUSHING
.19" CLEAR LEXAN™
SPACER
1'-11 1/2"2'-2"2'-2"1'-11 1/2"
2'-7 1/2"
11'-6 5/8"
8"
11'-8 3/4"
1'-2 5/8"
1'-6"
2'-6"
2'-7 1/2"
10"
2'-4"
Frame Detail
10'-6"
4'-11 5/8"
Brick
Natural
Stone 2” x 2” Steel
Square tubing
framing
1/2 HardieBacker
Cement Board
4” x 2” Steel
Rectangular
Tubing
1” x 1” Aluminium
Tubing skined with
.090 Aluminium
Concrete Footer
See sheet:
20415cv1s2_cc_jacksonville_
CALIBER COLLISION/ CHANNEL LETTERS/ CARMEL
Steel Support Pipe
5.563” Dia. - .258”
Steel Support Pipe
Saddle
2” x 2” x 3/16
Steel Angle
Welded to Pipe
5” SLAB W/ #4 REBAR @ 12” O.C.
FINAL GRADE
7’-6”7’-0”UNDISTURBED
SOIL
2500 PSI CONCRETE (MIN.)
2’-0”
SCALE: 1/2” = 1’-0”5”TYPICAL OF ONE PIER
6” OF CONCRETE OR
CRUSHED CINDER BLOCKSPLACED IN BOTTOM OF
FOUNDATION PRIOR TO
MAIN POUR
SLAB PLAN VIEW2’-0”SCALE: NTS
#4 REBAR @ 12” O.C.
T & B, EACH WAY
12’-0”
ELECTRICAL REQUIRMENTS
2.7 AMPS TOTAL @ 120V
3 Power Supplies
(1) 20 AMP CIRCUIT REQUIRED
Steel Angle Framing
Bolted to Steel Square
Tubing with 5/8” Bolts
ELEVATION SCALE: NTS
FINAL GRADE
END VIEW
5.563” Dia. - .258”
LISTED
MEMBER
INTERNATIONAL SIGN ASSOCIATION
Account Rep: Robert
Project Manager: Brandon
B MONUMENT SIGN
3/8” = 1’-0”
Grade A36 Steel Shapes
Grade A53 B Steel Pipe
Grade A307 Fastener Bolts
l
Date: Aug 22 2019
Drawn by: Zach
Drawing #: 30149bv2s3_cc_carmel_in_
wstcarmel_dr
Job #: 30149
Project/ Location:
503 West Carmel Dr.,
Carmel, IN 46032
B MONUMENT SIGN - TOP VIEW
1/2” = 1’-0”
CALIBER COLLISION/ MONUMENT SIGN LANDSCAPING/ CARMEL
LISTED
MEMBER
INTERNATIONAL SIGN ASSOCIATION
Account Rep: Robert
Project Manager: Brandon
Plant List:
• 38 Small Plant (max height of 1’-6”)
• 6 Medium Plants (2-4 feet high)
Date: Aug 22 2019
Drawn by: Zach
Drawing #: 30149bv2s4_cc_carmel_in_
wstcarmel_dr
Job #: 30149
Project/ Location:
503 West Carmel Dr.,
Carmel, IN 46032
11'-6 1/2"
1'-2"
17'-6 1/2"
7'-2"
Square Footage of Monument Sign: 14 sf
Square Footage of Landscaping: 126 sf
Medium Plants
Medium Plants
Small Plants
Small Plants
WOR K S C OPE
C O D E A L L O W A N C E
S I T E P L A N
Wall signs:
—
Monument signs:
—
1” = 125’-0”
b.v1
a.v1
Monument Signb.v1
CALIBER COLLISION/ SITE PLAN/ CARMEL
Date: June 15 2019
Drawn by: Zach
Drawing #: 30149sp_cc_carmel_in_
wstcarmel_dr
Job #: 30149
LISTED
MEMBER
INTERNATIONAL SIGN ASSOCIATION
Account Rep: Robert
Project Manager: Brandon 503 West Carmel Dr.,
Carmel, IN 46032
ROW
W CARMEL DR
102'-10"
148'-11 1/4"
264'-9 3/4"
245'-7 3/4"
New Masonry Monument