HomeMy WebLinkAboutCLAY CORNER 53 - CC053 (AS DESIGNED)IECC 2009 Performance Compliance Property 1508 MAIRN AVE CARMEL, IN 46032 Model: PENNINGTON (C) Community: CLAY CORNER 53 CC053 (AS DESIGNED) CLAY CORNER 53 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance 51,702 $264 $380 $2,346 $909 $0 $3,254 Requirements C-M, Energy Solutions As Designed S1,730 S228 S380 $2,337 S909 S0 $3,246 C4405.3 Performance -based compliance passes by 0.4% R402.4.12 Air Leakage Testing Air sealing is S.DD ACH at 5D Pa. It must not exceed 7.DD ACH at 50 Pa. C4402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration U-Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation Design exceeds requirements for IECC 2009 Performance compliance by 0.4%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC orwill be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 9f 11119 at 7: 28 AM Ekotrope RATER - Version 3.1.0.2249 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 1508 MAIRN AVE CARMEL, IN 46032 Builder: LENNAR HOMES �J PTO Pi Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls R-11 Framed Floor N/A Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U-Value: 0.33, SHGC: 0.28 Building Features Duct Supply R-10.0, Return R-10.0 Duct Leakage to Outside 260 CFM25 (4.991100 s.f.) Total Duct Leakage 416 CFM25 (Post -Construction) Heating Furnace • Natural Gas • 95.5 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. It rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications. and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the I ECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 9111119 at 7:28 AM Ekotrope RATER - Version 3.1.0.2249 20091ECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESIN ETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information sh own on this report. Energy Code Inspection Checklist Property Organization 1508 MAIRN AVE TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON (C) Community: CLAY CORNER 53 Builder LENNAR HOMES CC053 (AS DESIGNED) CLAY CORNER 53 General Building Information Conditioned Area (sq ft) 5,213 Conditioned Volume (cubic ft) 45,982 Insulated Shell Area (sq ft) 9,580 inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab [ Name: BSMT(2,139 s.f., 217 ft. exterior perimeter) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall [ Name: CONDIAMB (Exterior Perimeter [ft]: 197, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 E[ Name: CONDIGAR (Exterior Perimeter [ft]: 20, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8) R: 11.00 Feet from top of wall to top of insulation: 0, Feet from top of wall to bottom of insulation: 4 Above Grade Wall El Name: CONDIAMB 2X4 (2,413 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I [ Name: CONDIGAR (180 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Energy Code Inspection Checklist Property organization 1508 MAIRN AVE TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON (C) Community: CLAY CORNER 53 Builder LENNAR HOMES CC053 (AS DESIGNED) CLAY CORNER 53 Name: CONDIATTIC (408 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist El Name: RIM CONDIAMB (197 s.f.) R: 13.575 Name: BAND CONDIAMB (67 s.f.) R: 13.575 El Name: CONDIGAR (20 s.f.) R: 10.876 Name: CONDIATTIC (64 s.f.) R: 13.575 Roof El Name: SECOND (2,139 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door El Name: FRONT (24 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected El Name: FRONT (120 s.f.), U: 0.330, SHGC: 0.28, Orientation: SOUTH El Name: BACK(90 s.f.), U: 0.330, SHGC: 0.28, Orientation: NORTH C", Energy Solutions 2 Energy Cade Inspection Checklist C-M Energy Solutions Property Organization Inspection Status 1508 MAIRN AVE TSI Energy Solutions Results are projected CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON (C) Community: CLAY CORNER 53 Builder LENNAR HOMES CC053 (AS DESIGNED) CLAY CORNER 53 E] Name: LEFT SIDE (93 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST El Name: LEFT SIDE GD (20 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST El Name: BSMT (32 s.f.), U: 0.330, SHGC: 0.28, Orientation: WEST El Name: RIGHT SIDE (73 s.f.), U: 0.330, SHGC: 0.28, Orientation: EAST El Name: BSMT (16 s.f.), U: 0.330, SHGC: 0.28, Orientation: EAST Skylight None Present Mechanical Ventilation None Present Mechanical Equipment M Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5 AFUE El Air conditioner • Electric • 100% Cooling Load @ 13 SEER E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 3,832 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. 3 Energy Code Inspection Checklist Property 1508 MAI RN AVE CARMEL, IN 46032 Model: PENNINGTON (C) Community: CLAY CORNER 53 CC053 (AS DESIGNED) CLAY CORNER 53 Duct Leakage Duct System 1 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected NOT entirely within conditioned space, testing required Leakage to Outside specified as: 260 CFM25 (4.99 / 100 s.f.) Total Leakage specified as: 416 CFM25 (Post -Construction) Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage t= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 5N5 4 Building Summary Property Organization Inspection Status 1508 MAIRN AVE TSI Energy Solutions Results are projected CARMEL- IN 46032 Matthew Timmons Model: PENNINGTON (C) Community: CLAY CORNER 53 Builder LENNAR HOMES CC053 [AS DESIGNED] CLAY CORNER 53 Genera?Building Information Number Of Bedrooms 4 Number Of Floors 2 Conditioned Floor Area [sq_ ft.] 5;213 Unconditioned, attached garage? Yes Conditioned Volume [Cu. ft.] 45;982 Total Units in Building 1 Residence Type Single family detached Floor Number Model PENNINGTON (C) Community CLAY CORNER 53 Climate Zone 5A C-M, Energy Solutions Foundation Wall Name Library Type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Draped, 4Pt 1 8 197 Exposed Exterior Conditioned Space CONDIGAR R-11 Draped, 4Pt 1 8 20 Exposed Exterior Conditioned Space Foundation Wall Library List Name Feet From Wall Top To Feet From Wall Top To Is Fully Insulated Continuous R-value Cavity R-value Effective Insulation R- Continuous Insulation Continuous Insulation value Top Bottom R-11 Draped_ Oft 0 4 No N?A NIA 11.00 Slab Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Masonry Area Area Location Enclosing BSMT Uninsulated 217 Below Grade 0 0 2:139.0 11:2 Exposed Exterior Conditioned Space Slab Library Lis Name Wall Construction Slab Completel Underslab Perimeter Perimeter Thermal Break Effective R-value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value Uninsulated Wood Frame / Other No 0 0 0 No D.00 1 Building Summary Property 1508 MAIRN AVE CARMEL- IN 46032 Model: PENNINGTON [C] Community: CLAY CORNER 53 CC053 [AS DESIGNED] CLAY CORNER 53 Framed Floor Framed Floor Library List Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected C-M, Energy Solutions Rim Joist i Name Library Type Surface Area Location BAND CONDIAMB G1 R-13, R-3.0 67.0 fF Exposed Exterior CONDIATTIC G1 R-13, R-3.0 64.0 fF Attic CONDIGAR G1 R-13, OSB 20.0 W Exposed Exterior RIM CONDIAMB G1 R-13, R-3.0 1970.fC` Exposed Exterior Rim Joist Library List Name Effective Insulation R-value G1 R-13, OSB 10.876 G1 R-13, R-3.0 13.575 Name Library Type Surface Color Surface Area Location CONDIAMB 2X4 G1 R-13 BATT, R-3.0 Medium 2.413.0 ft' Exposed Exterior CONDIATTIC G1 R-13 BATT, R-3.0 Medium 408.0 ft' Attic CONDIGAR G1 R-13 Gar Walls Medium 180.0 ft' Llnoonddioned, attached garage 2 Building Summary Property Organization Inspection Status Energy C-M Solutions 1508 MAIRN AVE TSI Energy Solutions Results are projected CARIAEL- IN 46032 Matthew Timmons Model: PENNINGTON [C] Community: CLAY CORNER 53 Builder LENNAR HOMES CC053 [AS DESIGNED] CLAY CORNER 53 Wall Library List Name Effective R-value G1 R-13 BATT, R-3.0 15.12 G1 R-13 Gar Walls 11.141 Glazing Name Library Type 0 Wall Assignment Foundation Wall Overhang Assignment Depth Overhang Ft Top To Overhang Ft To Bottom Orientation M Surface Area BACK U-.33, SHGG28 CONDIAMB 2X4 0 0 0 North 90.0 fF BSMT U-.33, SHGG28 CONDIAMB 0 0 0 West 32.0 fF BSMT 11-.33, SHGG28 CONDIAMB 2X4 0 0 ❑ East 16.0 fF FRONT 11-.33, SHGC-28 CONDIAMB 2X4 0 0 ❑ South 1200.fts LEFT SIDE 11-.33, SHGG28 CONDIAMB 2X4 0 0 ❑ West 93.0 ft LEFT SIDE GD 11-33, SHGG28 CONDIAMB 2X4 0 0 ❑ West 20.0 ft RIGHT SIDE 11-33, SHGG28 CONDIAMB 2X4 0 0 ❑ East 73.0 f' Glazing Library List Name Shgc U #actor I1-33, SHGC-28 0.28 0.330 Skylight Skylight Library List 3 Building Summary Property Organization 1508 MAIRN AVE TSI Energy Solutions CARMEL- IN 46032 Matthew Timmons Model: PENNINGTON [C] Community: CLAY CORNER 53 Builder LENNAR HOMES CC053 [AS DESIGNED] CLAY CORNER 53 Opaque Door Name Library Type Wall Assignmen FRONT Fiberglass Door CONDIAMB 2X4 IGARAGE Fiberglass Door CONDIGA.R Opaque Door Library List i Name IFiberglass Door ndatPon Wall Assignment 0.182 Inspection Status Results are projected Solar Absorptance C-M, Energy Solutions PF M r Surface Area Location 0.9 0.75 Medium 24.0 fr Exposed Exterior 0.9 0.75 Medium 18.0 fr Exposed Exterior Roof Insulation i Name Library Type Attic Exterior Area Clay or Concrete Roof Surface Color Surface Area P.f.] Tiles Location SECOND R-38 Blown, GR1 2,139 No Medium 2,139.0 ff Attic Roof Insulation Library List Name Has Radiant Barrier Effective R-value ?•8 3 :a l No 38268 Whole House Infiltratic Infiltration I5 ACH at 50 Pa Mechanical Ventilation Blower -door tested 4 M Building Summary Property Organization Inspection Status C-MEnergy Solutions 1508 MAIRN AVE TSI Energy Solutions Results are projected CARIAEL- IN 46032 Matthew Timmons Model: PENNINGTON [C] Community: CLAY CORNER 53 Builder LENNAR HOMES CC053 [AS DESIGNED] CLAY CORNER 53 Lighting % Interior Fluorescent °% Interior LED Ughting % Exterior Fluorescent % Exterior LED Lighting % Garage FI uorescent % Garage LED Ughting Lighting Lighting Lighting 100 0 100 C 10C Gnsite GenerationMEN&MM � None Present Gnsite Generation Library List None Present Solar Generation I None Present Solar Generation Library List None Present Conditioning Equipment I Name Library Type Heating Percent Load Cooling Percent Load Hot Water Percent Load Location Airconditioner 4AC'42P 0% 100% ❑% Conditioned Space Fuel -fired air 915SA4206OS17 100% 0% ❑ % Conditioned Space distribution Water Heating RE350` 0% 0% 100 % Conditioned Space A Building Summary Property 1508 MAIRN AVE CARMEL- IN 46032 Model: PENNINGTON [C] Community: CLAY CORNER 53 CC053 [AS DESIGNED] CLAY CORNER 53 L Equipment Type: 4AC*42P Fuel Type Distribution Type Motor Type Cooling Efficiency Cooling Capacity [kBtulh] Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Electric Forced Air PSG (Single Speed) 13 SEER 40 ■ ' Equipment Type: 915SA42060517 Fuel Type Distribution Type Motor Type Heating Efficiency Heating Capacity [kBtulh] Use default EAE EAE [kWh] Equipment Type: RE350* Fuel Type Distribution Type Hot Water Efficiency Tank Capacity (gal.) Hot Water Capacity [kBtulh] Recovery Efficiency Natural Gas Forced Air PSG (Single Speed) 95.5 AFUE 58 No 636 Electric Hydronic Delivery 0.93 Energy Factor 50 15.4 0.98 C-M, Energy Solutions Building Summary Property Energy Solutions Organization Inspection Status C-M 1508 MAIRN AVE TSI Energy Solutions Results are projected CARIAEL- IN 46032 Matthew Timmons Model: PENNINGTON [C] Community: CLAY CORNER 53 Builder LENNAR HOMES CC053 [AS DESIGNED] CLAY CORNER 53 Distribution System Distribution Type Forced Air Heating Equipment Fuel -fired air distribution Cooling Equipment Air conditioner Sq. Feet Served 5213 # Return Grilles 5 Supply Duct R Value 10 Return Duct R Value 10 Supply Duct Area r] 1407.51 Return Duct Area [ft2] 1303.25 Leakage to Outdoors 260 CFM25 (4.991 100 s.f.) Total Leakage 416 CFM25 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct t Duct Location Conditioned Space Percent Supply Area 50 Percent Return Area 50 Duct 2 Duct Location Attic (well vented; under insulation) Percent Supply Area 50 Percent Return Area 50 Duct 3 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area 0 Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 5 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area ❑ rCeiling Fan W Has Ceiling Fan No Cfm Per Watt 101 7 Building Summary Property 1508 MAIRN AVE CARMEL- IN 46032 Model: PENNINGTON [C] Community: CLAY CORNER 53 CC053 [AS DESIGNED] CLAY CORNER 53 Water Distribution MM Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I met Appliances and Controls Programmable thermostat? Dishwasher Size Dishwasher Efficiency Range/Oven Fuel Convection Oven? Induction Range? Refrigerator Consumption r5N5 Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Standard No 65 No No 30 No Electric Timer Controls ff"W 704 kWh/Year $0.081kWh $23.00 $0.581Therm 2.874 ❑.33053 Yes Standard 270 kWh Natural Gas No No 709 kWh/Year C-M, Energy Solutions ,�