HomeMy WebLinkAboutNEWARK 36A - NEW036A (AS DESIGNED)IECC 2909 Performance Compliance
Property
132 SHOSHONE DR
CARMEL, IN 46033
Model: FRANKLIN
Community: NEWARK 36A
NEW036A (AS DESIGNED)
NEWARK 36A
Organization
TSI Energy Solutions
Devin Sielschott
Builder
SIGMA BUILDERS, LLC
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$2,058
$323
$221
$2,602
$1,430
$0
$4,032
Requirements
C4405.3 Performance -based compliance passes by 3.5%
R402.4.12 Air Leakage Testing
C4402.5 Area -weighted average fenestration SHGC
402.5 Area -weighted average fenestration U-Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4D52 Duct Insulation
C-M,
Energy Solutions
As Designed
$2,003
$287
$221
$2,511
$1,398
$0
$3,909
Air sealing is 3.00 ACH at 54 Pa. It must not exceed 7.00 ACH at 5D Pa.
design exceeds requirements for IECC 2009 Performance compliance by 3.5%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date: 9/24119 at 12:56 PM
Ekotrope RATER - Version 3.1.1.2258
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
132 SHOSHONE DR
I TJr-MPi
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls R-5
Framed Floor R-38
CARM EL, IN 46033
Builder: SIGMA BUILDERS, LLC
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 3 ACH50
Window U-Value: 0.3, SHGC: 0.25
Building Features
Duct Supply R-9.0, Return R-9.0
Duct Leakage to Outside 68 CFM25 (2 / 100 s.f.)
Total Duct Leakage 176 CFM25 (Post -Construction)
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Natural Gas • 0.64 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Devin Slelschott
Organization: TSI Energy Solutions
Signature:
Date:
9/24/19 at 12:50 PM
Ekotrope RATER - Version 3.1.1.2258
2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
Energy Code Inspection Checklist
Property Organization
132 SHOSHONE DR TSI Energy Solutions
CARMEL, IN 46033 Devin Sielschott
Model: FRANKLIN
Community: NEWARK 36A Builder
SIGMA BUILDERS, LLC
NEW036A (AS DESIGNED)
NEWARK 36A
General Building Information
Conditioned Area (sq ft) 5,681
Conditioned Volume (cubicft) 57,126
Insulated Shell Area (sq ft) 12,198
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
] Name: BSMT(1,727 s.f., 202 ft. exterior perimeter)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
El Name: GARAGE (890 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
El Name: OVER AMB (37 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Foundation Wall
] Name: UNFIN (Exterior Perimeter [ft]: 202, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 8)
R: 5.00
Feet from top of wall to top of insulation: 0.8, Feet from top of wall to bottom of insulation: 0
Above Grade Wall
El Name: CGNDIAMB (2,454 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
El Name: CGNDIAMB 2X6 (1,921 s.f.)
R-0 continuous insulation, R-19 cavity insulation
Insulation Grade: I
Energy Code Inspection Checklist
Property Organization
132 SHOSHONE DR TSI Energy Solutions
CARMEL, IN 46033 Devin Sielschott
Model: FRANKLIN
Community: NEWARK 36A Builder
SIGMA BUILDERS, LLC
NEW036A (AS DESIGNED)
NEWARK 36A
Name: CONDIGAR (210 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Rim Joist
El Name: CON ❑!AM B (466 s.f.)
R: 11.691
Roof
Name: CDNDIGAR (21 s.f.)
R: 11.691
Name: MAIN (2,654 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
El Name: GARAGE (24 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
E] Name: FRONT (36 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH
E] Name: FRONT 2X6 (236 s.f.), U: 0.300, SHGC: 0.25, Orientation: NORTH
E] Name: BACK (58 s.f.), U: 0.300, SHGC: 0.25, Orientation: SOUTH
El Name: BACK 2X6 (336 s.f.), U: 0.300, SHGC: 0.25, Orientation: SOUTH
El Name: BACK SLIDER 2X6 (78 s.f.), U: 0.300, SHGC: 0.25, Orientation: SOUTH
El Name: LEFT SIDE (88 s.f.), U: 0.300, SHGC: 0.25, Orientation: EAST
C-M,
Energy Solutions
2
Energy Code Inspection Checklist
TSI Energy Solutions
Property Organization Inspection Status
132 SHOSHONE DR TSI Energy Solutions Results are projected
CARMEL, IN 46033 Devin Sielschott
Model: FRANKLIN
Community: NEWARK 36A Builder
SIGMA BUILDERS, LLC
NEW036A (AS DESIGNED)
NEWARK 36A
E] Name: LEFT BSMT (16 s.f.), U: 0.300, SHGC: 0.25, Orientation: EAST
E] Name: LEFT GD (24 s.f.), U: 0.300, SHGC: 0.25, Orientation: EAST
El Name: LEFT 2X6 (54 s.f.), U: 0.300, SHGC: 0.25, Orientation: EAST
El Name: RIGHT (108 s.f.), U: 0.300, SHGC: 0.25, Orientation: WEST
El Name: RIGHT BSMT (16 s.f.), U: 0.300, SHGC: 0.25, Orientation: WEST
El Name: RIGHT 2X6 (18 s.f.), U: 0.300, SHGC: 0.25, Orientation: WEST
Skylight
None Present
Mechanical Ventilation
ElMechanical ventilation system rated for, and capable of, providing continuous ventilation.
System shall include automatic timing controls.
System type: Exhaust Only, 24 hrslday, 9 Watts.
Mechanical Equipment
E] SYSTEM 1 HEATING - Natural Gas • 60% Heating Load @ 92.1 AFUE
E] SYSTEM 2 HEATING - Natural Gas • 40% Heating Load @ 92.1 AFUE
E] SYSTEM 1 COOLING • Electric • 60% Cooling Load @ 13 SEER
E] SYSTEM 2 COOLING • Electric • 40% Cooling Load @ 13 SEER
El Water Heating • Natural Gas • 100% Hot Water Load @ 0.64 Energy Factor
Air Leakage Control 3
Energy Code Inspection Checklist
Property Organization inspection Status
132 SHOSHONE DR TSI Energy Solutions Results are projected
CARMEL, IN 46033 Devin Sielschott
Model: FRANKLIN
Community: NEWARK 36A Builder
SIGMA BUILDERS, LLC
NEW036A (AS DESIGNED)
NEWARK 36A
ElTest Status: Blower -door tested
House is air -sealed as to achieve 2,856 CFM50 (3.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Leakage to Outside specified as: 68 CFM25 (2 / 100 s.f.)
Total Leakage specified as: 176 CFM25 (Post -Construction)
Duct System 2
NOT entirely within conditioned space, testing required
Leakage to Outside specified as: 88 CFM25 (3.87 / 100 s.f.)
Total Leakage specified as: 176 CFM25 (Post -Construction)
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage a= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM251 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage a= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
4
Project Notes
Building Summary
Property
132 SHOSHONE DR
CARMEL, IN 46033
Model: FRANKLIN
Community: NEWARK 36A
NEW036A(AS DESIGNED)
NEWARK 36A
General Building Information
Organization
TSI Energy Solutions
Devin Sielschott
Builder
SIGMA BUILDERS, LLC
Inspection status
Results are projected
Number Of Bedrooms
5
Number Of Floors
2
Conditioned Floor Area [sq. ft.]
5,681
Unconditioned; attached garage?
Yes
Conditioned Volume [cu. ft.]
57,126
Total Units in Building
1
Residence Type
Single family detached
Floor Number
Model
FRANKLIN
Community
NEWARK 36A
Climate Zone
5A
Foundation Wall
Name Library type Height Above Grade Depth Below Grade Perimeter
C-M,
Energy Solutions
Location Enclosing
UNFIN R-5 Ext GRADE
1
8
202 Exposed Exterior
Conditioned Space
Foundation Wall Library List
Name Feet From Wall Top To Feet From Wall
Top To Is Fully
Insulated
Continuous R-value
Cavity
R-value Effective
Insulation R-
Continucus Insulation Continuous Insulation
value
Top Bottom
R-5 Ext GRADE 0.8
0
No
NIA
N/A
5.00
Slamw
44W
Name Library Type Perimeter
Floor Grade
Carpet R
Exposed
Surface Area
Location
Enclosing
Masonry Area
BSMT Uninsulated 202
Below Grade
1.2°
0
1,727.0 ft'
Exposed Exterior
Conditioned
Space
Slab Library List
Name Wall Constructian Slab Completely
Underslab
Perimeter
Perimeter
Thermal Break
Effective R-value
Type Insulated44
Insulation Width [ft]
Insulation
Depth [ft] Insulation RValue
Uninsulated Wood Frame i Other No
0
0
0
No
0.00
1
Building Summary
Property Organization
132 SHOSHONE DR TSI Energy Solutions
CARMEL, IN 46033 Devin Sielschott
Model: FRANKLIN
Community: NEWARK 36A Builder
SIGMA BUILDERS. LLC
NEW036A(AS DESIGNED)
NEWARK 36A
amed Floor
Name Library type Car
GARAGE R-38, GR1
OVER AMB R-38, GR1
Framed Floor Library List
Name Effective R-value
"-SS. G "" 12 825
Rim Joist
Name Library type
CONDIAMB G1 R-15. OSB
CONDIGAR G1 R-15. OSB
Rim Joist Library List
Name Effective Insulation R-value
G1 R-15, OS6 11.691
Inspection Status
Results are projected
C-M,
Energy Solutions
123 Above Grade 890.0 ft, Unconditioned, attached
garage
123 Above Grade 37.0 ft' Exposed Exterior
466.0 T Exposed Exterior
21.0 T Unconditioned, attached garage
Ir
Name
Library Type
Surface Color
Surface Area
Location
CONDIAMB
Exposed Exterior
G1 R-15 BATT, OSB
Medium
2.454.0 ft'
CONDIAMB 2X6
Exposed Exterior
G1 R-19. OSB 2x6
Medium
1.921.0 ft2
CONDIGAR
Unconditioned, attached garage
G1 R-15 Gar Walls
Medium
210.0 ft'
2
Building Summary
Property
Organization
Inspection
Status
Energy
C-M
Solutions
132 SHOSHONE DR
TSI Energy Solutions
Results are projected
CARMEL, IN 46033
Devin Sielschott
Model: FRANKLIN
Community: NEWARK 36A
Builder
SIGMA BUILDERS. LLC
NEW036A(AS DESIGNED)
NEWARK 36A
Wall Library Lis#
Name
Effective R-value
G1 R-15 BATT. OSB
13.423
G1 R-15 Gar Walls
11.972
G1 R-1 % OSB 2X6
17.591
Glazing
Name Library Type
Wall Assignment Foundation Wall
Overhang Depth
Overhang Ft To
Overhang Ft To
Orientation
Surface Area
Assignment
Top
Bottom
BACK U-.30. SHGG25
CONDIAMB
0
0
0
South
58.0 ft'
BACK 2X6 U-.30. SHGC-25
CONDIAMB 2X6
0
0
0
South
336.0 tt2
BACKSLIDER2X6 U-.30. SHGC-25
CONDIAMB 2X6
0
0
0
South
78.0 tt2
FRONT U-.30, SHGG25
CONDIAMB
0
0
0
North
36.0 ft'
FRONT 2X6 U-.30, SHGG25
CONDIAMB 2X6
0
0
❑
North
236.0 tt2
LEFT 2X6 U-.30, SHGG25
CONDIAMB 2X6
0
0
❑
East
54.0 tt2
LEFT BSMT U-.30. SHGG25
UNFIN
0
0
D
East
16.0 tt2
LEFT GD U-.30, SHGG25
CONDIAMB
0
0
D
East
24.0 f['
LEFT SI DE U-.30, SHGC-25
CONDIAMB
0
0
0
East
88.0 ttF
RIGHT U-.30, SHGG25
CONDIAMB
0
0
❑
West
108.0 tt2
RIGHT 2X6 U-.30. SHGG25
CONDIAMB 2X6
0
0
0
West
18.0 tt2
RIGHT BSMT U-.30, SHGG25
UNFIN
0
0
❑
West
16.0 tt2
Glazing Library Li
Name
U-.30. SHGC-.25
Shgc
U-facto r
025 0.300
9
Building Summary
Property
132 SHOSHONE DR
CARMEL, IN 46033
Model: FRANKLIN
Community: NEWARK 36A
NEW036A(AS DESIGNED)
NEWARK 36A
Skylight
Skylight Library List
Organization
TSI Energy Solutions
Devin Sielschott
Builder
SIGMA BUILDERS, LLC
Inspection Status
Results are projected
C-M,
Energy Solutions
Opaque ❑oorFM 0
Name Llibrary 'TV pe Wall Assignment FoundatianWaII Emittance Solar Surface Color Surface Area Location
Assignment Absorpta n ce
GARAGE FiberglasslSteel CONDIGAR 0.9 0.75 Medium 24.0 PI2 Exposed Exterior
Door
Opaque Door Library List A
Name Effective U-factor
Fiberglass?Steel Doc- 0.182
Roof Insulation
Name Library type Attic Exterior Area [s.f.] Clay or Concrete Roof
Tiles
klAIN R-38 Blown, GR1 2,654 No
Surface Color Surface Area Location
Roof Insulation Library List
Name Has Radiant Barrier Effective R-value
R-8 Blown, GR1 No 38.268
Medium 2,654.0 TF Attic
4
Building Summary
Property
Organization
Inspection Status
Energy Solutions
C-M
132 SHOSHONE DR
TSI Energy Solutions
Results are projected
CARMEL, IN 46033
Devin Sielschott
Model: FRANKLIN
Community: NEWARK 36A
Builder
SIGMA BUILDERS, LLC
NEW036A(AS DESIGNED)
NEWARK 36A
Whole House Infiltration
Infiltration
Measurement
type
Shelter Class
3ACH at 50 Pa
Blower -door tested
4
Mechanical Ventilation
Ventilation Type Ventilation Rate
"" I
Operational hours per day
Fan Watts
Runs once every three Energy Recovery Percent
Minute]
hours
Exhaust Only
20
24
9
Yes 0
Lighting
-
% Interior Fluorescent % Interior LED Lighting
°% Exterior Fluorescent
% Exterior LED Lighting
% Garage Fluorescent % Garage LED Lighting
Lighting
Lighting
Lighting
10
0
10
0
10 0
Gnsite Generation
None Present
Onsite Generation Library List
None Present
Solar Generation WOW
None Present
Solar Generation Library List
None Present
Building Summary
Property Organization Inspection Status
Energy Solutions
C-M
132 SHOSHONE DR TSI Energy Solutions Results are projected
CARMEL, IN 46033 Devin Sielschott
Model: FRANKLIN
Community: NEWARK 36A Builder
SIGMA BUILDERS. LLC
NEW036A(AS DESIGNED)
NEWARK 36A
Conditioning Equipment
Name Library Type Heating Percent Load Cooling Percent Load
Hot Water Percent Load Location
SYSTEM 1 COOLING CA13NA036 0% 60%
0% Conditioned Space
SYSTEM 1 HEATING 59SC2A060S14 60% 0%
0% Conditioned Space
SYSTEM 2 COOLING CA13NA036 0% 40%
0% Conditioned Space
SYSTEM 2 HEATING 59SC2A060S14 40% 0%
0% Conditioned Space
Water Heating RG1PV50S'N 0% 0%
100% Conditioned Space
Equipment Type: 59SUAOBOS14
Fuel Type Natural Gas
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Heating Efficiency 92.1 AFUE
Heating Capacity [kBtulh] 56
Use default EAE No
EAE [kWh] 507
Type: CA13NA036
e Electric
rquipment
on Type Forced Air
pe PSG (Single Speed)
Efficiency 13 SEER
Capacity [kBtulh] 34.2
quipment Type: RG1PV54S*N
Fuel Type Natural Gas
Distribution Type Hydronic Delivery
Hot Water Efficiency 0.64 Energy Factor
Tank Capacity (gal.) 50
Hot Water Capacity [kBtulh] 40
Recovery Efficiency 0.80
6
Building Summary
Property
132 SHOSHONE DR
CARMEL, IN 46033
Model: FRANKLIN
Community: NEWARK 36A
NEW036A(AS DESIGNED)
NEWARK 36A
Distribution System
Distribution Type
Heating Equipment
Cooling Equipment
Sq. Feet Served
# Return Grilles
Supply Duct R Value
Return Dud R Value
Supply Duct Area [ftJ
Return Dud Area [ftq
Leakage to Outdoors
Total Leakage
Total Leakage Duct Test Conditions
Use Default Flow Rate
Duct 1
Duct Location
Percent Supply Area
Percent Return Area
Duct 2
Duct Location
Percent Supply Area
Percent Return Area
Duct 3
Duct Location
Percent Supply Area
Percent Return Area
Duct 4
Duct Location
Percent Supply Area
Percent Return Area
Duct 5
Duct Location
Percent Supply Area
Percent Return Area
Duct 6
Duct Location
Percent Supply Area
Percent Return Area
Organization
TSI Energy Solutions
Devin Sielschott
Builder
SIGMA BUILDERS. LLC
Forced Air
SYSTEM 1 HEATING
SYSTEM 1 COOLING
3408
3
9
9
6❑5.88
336.6
68 CFM25 (21 100 s.f.)
176 CFM25
Post -Construction
Yes
Conditioned Space
75
75
Attic (well vented; under insulation)
25
25
Conditioned Space
0
0
Conditioned Space
Conditioned Space
Conditioned Space
Inspection Status
Results are projected
C-M,
Energy Solutions
7
Building Summary
Property
Energy Solutions
Organization Inspection Status C-M
132 SHOSHONE DR
TSI Energy Solutions Results are projected
CARMEL, IN 46033
Devin Sielschott
Model: FRANKLIN
Community: NEWARK 36A
Builder
SIGMA BUILDERS. LLC
NEW036A(AS DESIGNED)
NEWARK 36A
Distribution System
Distribution Type
Forced Air
Heating Equipment
SYSTEM 2 HEATING
Cooling Equipment
SYSTEM 2 COOLING
Sq. Feet Served
2273
# Return Grilles
3
Supply Duct R Value
9
Return Dud R Value
9
Supply Duct Area [ftJ
605.88
Return Dud Area [ftq
336.6
Leakage to Outdoors
88 CFM25 (3.87 f 100 s.f.)
Total Leakage
176 CFM25
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
75
Percent Return Area
75
Duct 2
Duct Location
Attic (well vented; under insulation)
Percent Supply Area
25
Percent Return Area
25
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
0
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
❑
Ceiling Fan
-
Has Ceiling Fan
No
Cfm Per Watt
101
rA
Building Summary
Property
132 SHOSHONE DR
CARMEL, IN 46033
Model: FRANKLIN
Community: NEWARK 36A
NEW036A(AS DESIGNED)
NEWARK 36A
Water Distribution
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field Utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I mef
ppliances and Controls
Programmabie thermostat?
Dishwasher Size
Dishwasher Efficiency
RangefOven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
Organization Inspection Status
TSI Energy Solutions Results are projected
Devin Sielschott
Builder
SIGMA BUILDERS. LLC
Standard
No
50
No
No
20
No
Electric
Timer Controls
704 kWh[Year
$0.081kWh
$23.00
$0.581Therm
2.874
❑.331
Yes
Standard
270 kWh
Natural Gas
No
No
715 kWh[Year
C-M,
Energy Solutions
A