HomeMy WebLinkAboutM100.0U P
C
3
3
R
R R
R
3
3
R
3
R
R
R
3
R R
R R
R R
RR
C5E
R
DW
O
M
3
GFCI
SD
SD
11
22
44
33
44
44
55 66
77
88
99
1 010
1 010 1 111
1 212
1 313
1 313
1 414
1 515
1 616
1 616 1 717
44 44
44 Erickson ResidenceMain Level Remodel1540 White Ash DriveCarmel, IN 46033Date:Revision
:
4
SHEET OF 7
SIGNATURE /
SEAL DESIGNER: ALLISON COPELANDE:allison@customlivingusa.comC: 317.417.4292Client Initials:
Date:
The plans, including all text, drawings, concepts and ideas,
forming a part of the plans, and the selection and arrangement
thereof Copright 2018 by Custom Living, Inc., Indianapolis IN.
ALL RIGHTS RESERVED. The plans shall remain the property of
Custom Living Inc. Any use of the plans, or their content, without
the prior written permission of Custom Living. Inc is strictly
prohibited.
PROPOSED M.E.P PLAN
SCALE: 1/4" = 1'
REV #1 07.23.19CUSTOM LIVING5335 Winthrop AveIndianapolis IN 4622010/9/2019
DATE:
GENERAL M.E.P NOTES
HVAC Contractor is responsible for engineering
calculation necessary for correct sizing of new
equipment and ducwork being
supplied,fabricated and installed for the project.
HVAC ductwork being installed in unconditioned
areas to be insulated and sealed per current
Building Code Standards.
HVAC contractor to start up, test and balance
new equipment and ductwork to assure proper
operation of new systems.
Final plumbing materials selected may have an
affect on the final Plumbing Material and
Installation Budgets.
Owners understand that if additonal plumbing,
electrical or ductwork is foun in walls being
deleted that is not included on the plans there
will be a Change Order during construction to
relocate as necessary.
Owners understand that during mechanical
rough-ins there will be times when the water
service will be shut of to areas in the home.
Plumbing and Lighting fixtures supplied by
Owner will not be Warrantied by Custom Living
Plumbing and Lighting fixtures supplied by
Owner must be selected and onsite prior to start
of Mechanical Rough-In's
HVAC PLAN NOTES
HVAC permit will not be required for this project
See Existing/Demo Plan for any necessary
disconnects.
No exhaust fan in bathroom
See Interior Selections Document for register
material specification
PLUMBING PLAN NOTES\
Plumbing permit will be required for this project
See Existing/Demo Plan for any necessary
disconnects.
Install drain and supply lines as necessary for
fixtures as shown on the M.E.P Plan.
Install plumbing fixtures as shown on the M.E.P
Plan.
See Interior Selections Document for plumbing
fixture material(s).
See Interior Selections Document for Appliance
Model No.(s).
Plumbing Contractor to pressurize system prior
to drywall installation
ELECTRICAL PLAN NOTES
Electrical Permit will be required for this project.
See Existing/Demo Plan for any necessary
disconnects.
Existing panel sizing has been verified for project
shown in Electrical Plan
Install switches/outlets per Electrical Plan.
Install lighting per Electrical Plan.
Install dedicated circuits per Electrical Plan.
Install updated smoke detectors per Electrical
Plan, (4) on the Second Level, (2) on the Main
Level, and (1) in the Basement.
See Interior Selections Document for lighting
material(s).
See Interior Selections Document for switch/
outlet device material(s).
See Interior Selections Document for Appliance
Model No.(s).
LOW VOLTAGE PLAN NOTES
See note 12 for details. Install new LED tape light
with (1) switch
NEW OUTLET DEVICE STYLE
NEW SWITCH DEVICE STYLE
ALL NEW
WALL
OUTLETS
DIMMER
SWITCHES
WHERE
NOTED
ALL NEW
SINGLE
POLE AND 3
WAY
SWITCHES
RECESSED CAN LIGHTS
4" 3000K
MODEL NO.
JUN O-4RLD-
930-6-WWH
DECORATIVE SCONCES
PROVIDED BY
HOMEOWNERS
UNDERCABINET LIGHTING
NONE IN SCOPE
OF WORK
** PRINTS TO SCALE IF PRINTED ON 24" X 36" **
ELECTRICAL CALL-OUT NOTES
1. Install Telephone and CAT5 jack in office
2. Install 4" LED recessed lights
3. Install new switch
4. Keep Existing outlets
5. Install (4) 4" LED recessed lights and dimmer
switch
6. Install (3) 4" LED recessed lights and 3-way dimmer
switch
7. Install (4) 4" LED recessed lights and 3-way dimmer
switch
8. Install new outlet in island
9. Install (1) 4" LED recessed light and dimmer switch
10. Move Switch
11. Install (2) 4" LED recessed lights on dimmer switch
12. Install new LED tape light with dimmer switch
13. Existing light to remain
14. Install new vanity light fixture with switch
15. Install outlet in wall cabinet
16. Install outlets horizontal in backsplash. VIF with
trades
17. Cabinet maker to provide charging station
accessory. Electrical to install power for the
accessory.
REV #2 09.09.19
REV #3 09.16.19
REV #4 10.7.19
10/10/19
Mike Sheeks