HomeMy WebLinkAboutWall Section Pulte Homes of Indiana
Roof Shingles Per Spec.
7/16" OSB WI"H"Clips
IInsultaion baffle 2"min.clear
2-2x4 Top Plate
R-38 Insulation iv- OMNI Soffit WNents 4'O.C.
1x6
li
;I1;
� Outside Air Film (R .17)
1/2"GYP. BD Al HOR Siding Per Spec. (R .16)
R-.45
Inside air film _
2x4 Stud 16" O.C.
SIDING SECTION
R= Fiberglass Batt I '
1/2"TYP.BD 0.45 R-13 Insulation
R-13 Insulation 13.00 2X4 Bottom Plate
Inside Air Film 0.68
Outside Air Film 0.17 1X12 Rim Joist ��, 3/4"T&G Subfloor(glue&nail)
i
Siding per Spec. 0.16 Per O.J. Spec ilk On O.J. Floor Joist at 19.2"o.c.
R-5 Rigid Insulation 5.00 O.J.Joist at 19.2"o.c .% —R-13 Fiberglass Batt Insulation
Total 19.46 ��d'
BRICK SECTION 1/2" GYP. BD 2X4 Brick Ladder on 1X4
1/2"GYP. BD 0.45 R-.45 ,'
R-13 Insulation 13.00 Inside Air Film A R-5 Rigid Insulation Sheathing
Inside Air Film 0.68 R.68 I, 1" Min. Siding Overlap
R-5 Rigid Insulation 5.00 R-13 Insulation 4101
Outside Air Film 0.17
Brick to Grade 0.68 / _ Outside Air Film (R.17)
Total 19.98 2X4 Bottom Plate
3/4"T&G Subfloor(glue&nial)
On O.J. Floor Joist at 19.2"o.c.
iii .,. 7
# 6 grade 60 re-bar placed Iii 2X4 P.T. Sill Plate W/AB's Per
vertically @ 24" O.C., 2 ° I Spec Locate Plate Squarely on
from inside of basement �: Top of Wall as Shown
wall, 6" from soil side of wall ,.i Brick to Grade-Field Verify
Re-bar 3" from top -t F Brick Ledge(R.68)
Grade Level Weepholes Max Spacing
i r_
33"O.C. @ 3/8" Diameter
i
Wall Flashing Under Brick
P 1,
E1-
8"Concrete Wall Field Verify
Pour Height
mii
Bitouminous Waterproofing Per
4" Sec. on Cementitious Par in
Poured Conc. • , p Parging
pn 4"Min. Sand Fill P.7 �: ,._ 4" Perforated Drain Tile
6 mil.vapor barrier Sched 3034
between granular
(III and concrete 8"X18"Cont. Poured
Concrete Wall
TYPICAL WALL SECTION