HomeMy WebLinkAboutA121 Electrical - Reflected CeilingELECTRICAL LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
POWER OUTLET, DUPLEX
POWER OUTLET, DUPLEX
.N,
^R'
POWER OUTLET,
POWER OUTLET,
QUADRUPLEX
QUADRUPLEX
J
JUNCTION BOX
J
JUNCTION BOX
OCEILING
MOUNTED
CEILING MOUNTED
JUNCTION BOX
JUNCTION BOX
®
BOX, BLANK COVER PLATE
®
BOX, BLANK COVER PLATE
BOX, OPEN
QO
BOX, OPEN
P
PROVIDE JUNCTION BOX
P
POWER AND DATA POLE
D
ABOVE CEILING FOR
O
POWER POLE
CONNECTION. POWER
POLE BY OTHERS.
FLOOR BOX WITH POWER
FLOOR BOX WITH POWER
5I4
AND DATA, FLUSH
&K7
AND DATA, FLUSH
MOUNTED
MOUNTED
FLOOR BOX WITH
FLOOR BOX WITH
J I I
JUNCTION BOX AND
J b
JUNCTION BOX AND
DATA, FLUSH MOUNTED
DATA, FLUSH MOUNTED
DATA/COMMUNICATION
10
OUTLET (PROVIDE BOX
4
DATA/COMMUNICATION
AND PULL STRING ONLY)
OUTLET
DED
DEDICATED CIRCUIT
GFCI
GROUND FAULT CIRCUIT
INTERRUPT OUTLET
+42"
HEIGHT OF ELECTRICAL
OR DATA DEVICE
I . r
�P I QMQ
r3nK
GENERAL ELEC. NOTES
I. TENANT'S FURNITURE VENDOR IS RESPONSIBLE FOR INSTALLATION OF
FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS.
2. ALL OUTLETS ARE TO BE INSTALLED 18" MIN. A.F.F. TO THE CENTER OF
THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE, ALL
NEW DEVICES AND FACE PLATES TO MATCH EXISTING.
3. REFER TO DOOR SCHEDULE AND COORDINATE WITH
TENANT/OWNER REGARDING POWER LOCATIONS TO
ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR
MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE
TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI.
4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK DOES NOT
EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN
THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY
APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT
ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL
APPLICABLE CODES,
ELECTRICAL PLAN NOTES
E01 NEW OUTLETS MAY BE GFCI IN THIS ROOM DEPENDING ON FINAL
LOCATION OF NEW SINKS. COORDINATE WITH TENANT.
OPROVIDE OUTLET FOR TENANT PROVIDED SPEAKER, COORDINATE
E02 EXACT LOCATION WITH TENANT.
RCP LEGEND
NEW OR RELOCATED
LIGHT FIXTURE, 2'x4
D
E
LIGHT FIXTURE, Tx2'
LED
LIGHT FIXTURE,
TRACK
In
NIGHT FIXTURE,
PENDANT
NL
NIGHT NIGHT
EXISTING TO REMAIN
®
EXIT LIGHT FIXTURE: LED
®
EXIT LIGHT FIXTURE
EDGE LIT
EMERGENCY LIGHT FIXTURE
EMERGENCY LIGHT HXTURE
$N
NIGHT SWITCH
$
NIGHT SWITCH
$NG
SWITCH, GARBAGE
$G
SWITCH, GARBAGE
DISPOSAL (ABOVE
DISPOSAL
COUNTERTOP)
$NE
SWITCH, EXHAUST FAN
$E
SWITCH, EXHAUST FAN
$N3
LIGHT SWITCH,&WAY
$3
LIGHT SWITCH,&WAY
' f7U CEILING GRID,
N� SUSPENDED, 2'x2'
New QM _C.'zti�t
CO I
ap DS✓kluew
luf( pw.e) ❑ EXPOSED TO DECK
2aIta�'tesl
y�9v14
1
c.j. FT I j EXrYnA
�.�x I
3r EC
Ec-sjru� Y°f ✓�' (fuJ,n¢E TNWI4 H"%✓C
New(u)i�xN Ei�l4
1/ EC ,
�r-MICE h'Sc'P
>�t
n ELECTRICAL RISER DIAGRAM
AI21 o TYPICAL ALL SINGLE LOCATIONS, NOT TO SCALE
MAIN TRY f Ln ` Iy\
���KX�..c� ���lI�GGE�
�^c �,lT SST �,11 SST
�A �A
i
t
t
BAR
® E02 0000
Coon
Fnnn�
PRIVATE ROOM
rm
® AREA NOT IN CONTRACT
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City of Camel
jaMG ,A
DATE: 10/15/19
UTILITIES
mn
STORAGE /
® a
�LL
ELECTRICAL PLAN
0 2' 4' 8' 16'
RELOCATED DIFFUSER,
DIFFUSER,
LAY 2'x2'
®
LAY IN, 2'X2
RELOCATED DIFFUSER,
DIFFUSER,
LAY -IN, I
®
LAY IN, I'x4'
RELOCATED DIFFUSER,
DIFFUSER,
®
LAY -IN, 4"x4'
m
LAY IN, 4W
7
EXHAUST FAN, 2'x2
EXHAUST FAN, 2'x2
NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILING TILES
SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW
HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET.
GENERAL NOTES
I. PROVIDE EMERGENCY LIGHTING IN TENANTSPACEAS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN
SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI
OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT
IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
2. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS.
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT
INSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1,
CONTRACTOR MUST NOTIFY SDI. OVER 50%OF THE LIGHTING WILL
BE REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL
NEED TO BE MET.
3. ALL NEW SWITCHES TO BE OCCUPANCY SENSORS; PROVIDE COMBO
UNIT WITH BOTH ULTRASONIC AND INFRARED TECHNOLOGY WITH A
ONE BUTTON OVERRIDE. OCCUPANCY SENSORS ARE TO BE
LOCATED SUCH THAT OCCUPANCY WITHIN ANY PORTION OF
INCLUDED AREA IS DETECTED. PROVIDE CEILING MOUNTED
OCCUPANCY SENSORS IN OPEN AREAS AS REQUIRED.
4. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE
POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE
MULTI-S W ITCH PLATE WHEN SWITCHES ARE SHOWN ADJACENT ON
PLAN.
5. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO
ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND
LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING
ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS
TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED
SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH
ALL APPLICABLE CODES.
® aN3✓
0
G
MECHANICAL NOTES
I. MECHANICAL WORK IS LIMITED TO A DESIGN- BUILD SCOPE AND IS
OUTLINED IN THESE DRAWINGS. NO NEW MAIN MECHANICAL
APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL
MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND
FLEX DUCT PER NEW WALL LAYOUT. NO NEW HARD DUCTWORK OR
EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO
NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO
THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE
INDIANA MECHANICAL CODE AND ALL OTHER APPLICABLE CODES.
2. HVAC LAYOUT TO BE APPROVED PRIOR TO WORK BEING COMPLETED.
ALL THERMOSTATS MUST BE CALIBRATED AND AIR BALANCED.
PROVIDE REPORT TO OWNER.
RCP PLAN NOTES
R01 IN AREA TO BE EXPOSED TO DECK, PROVIDE NEW RIGID SPIRAL
DUCT AND RECTANGULAR SUPPLY DIFFUSERS AS REQUIRED.
R02 EXPOSED CEILING TO BE CLEANED AND PAINTED PT_.
OPROVIDE NEW 2'X2'9/16" CEILING GRID AND ARMSTRONG
R03 KITCH EN ZONE LAY -IN CEI LI NG TI LE AT 10-0" A FF, CENTERED IN
ROOMASSHOWN.
R04 S PRAY EXPOSED CEI LI FIG K 13 ACCUSE C SPRAY.
IN AREA TO BE EXPOSED TO DECK, AS AN ALTERNATE PRICE,
ROS PROVI DE NEW RIGI D S PI RA L D UCT AN D RECTA NGU LA R S U PPLY
DIFFUSERS AS REQUIRED. SPRAY EXPOSED CEILING K13 ACOUSTIC
SPRAY.
FnRO2
G N
R01 R05
R02
m
R
IF
�1� ■ __��
1■■_■■■■_■■
1■■■■r■■■1
e
0
� N
O
O
r Z
^'
L �
o O ri
P O
o
O
w O M
N
� O Q
Qa
C
THIS DRAWING. AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOTTO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
N
CM
O
■�
V
Z
W
W
Woe
r
Q
+
uJ
U
ZNW
W
Z
I-
W
C
J
W
�t
REVISIONS
MARX DATE I DB (DESCRIPTION
No.
AR10700017
STATE OF
PROJECT NUMBER
2019.308
PROJ.MGR DRAWN BY
AS NP
1ST FLOOR
ELECTRICAL PLAN/
REFLECTED
CEILING PLAN
A121